SteelCentral Product Family Specifications

Similar documents
SteelCentral Product Family Specifications

DataCore Virtualization Appliance

Dell Networking W-7200 Series mobility controllers

FLEXIBILITY FOR THE HIGH-END DATA CENTER. Copyright 2013 EMC Corporation. All rights reserved.

Copyright 2012 EMC Corporation. All rights reserved.

UNCLASSIFIED. Revised: 8/21/15 UNCLASSIFIED Page 1 of 6

Technical Specifications

LSI SAS e HBA Temperature and Airflow

Remanufactured Product Price List Publish Date 13-JUL-2017

System configurator and order-information guide Oct Top-of-Rack Ethernet Switch - PSWITCH 2048T S26361-F3986-L405

Series xx60, xx55, xx50, xx30 Rack Installation Guide

Dell EMC SCv ,000 Mailbox Exchange 2016 Resiliency Storage Solution using 10K drives

E-Series and EF-Series Systems

Closing Sale Prices. AmigoBot Pioneer 3-DX Pioneer 3-AT Pioneer LX Pioneer Manipulator PeopleBot PowerBot Seekur Jr

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Smart-UPS On-Line Lithium-ion UPS 230V

Features and Benefits. Certifications

Liebert PowerSure PSI UPS

Hardware Withdrawal: IBM TotalStorage Enterprise Storage Server selected features and feature conversions

POWERCOMMAND CLOUD REMOTE MONITORING SYSTEM

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Liebert. PSI & PSI-XR 750VA - 3kVA & 1kVA-3kVA High Performance Power Protection for Servers and Networking Equipment

5 5 Supervisor Engine GE (Active) VS S720 10G SAL1313MAFM

Dell Storage Compatibility Matrix

WHITE PAPER. Informatica PowerCenter 8 on HP Integrity Servers: Doubling Performance with Linear Scalability for 64-bit Enterprise Data Integration

OPTICAL TRANSCEIVER SPECIFICATIONS GUIDE. Optics DACs Cables Cable Management Media Converters

Agilent N5470A Series Oscilloscope Rack Mount Kit

ATC Series QSFP CP Active Transceiver Cooler

Uninterruptible Power Supplies

PRODUCT DESCRIPTIONS AND METRICS

The Forecast: Global EV Charging Stations will rise by 2020

HDS Gen3: 4.0. HDS Gen2 Touch: 6.0

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

System Level Design Review

Flex Amplifiers Installation Instructions

Digital/Analog Amplifiers Installation Instructions

BLUECAT ENTERPRISE DNS

QSFP Copper Module Direct Attach Cable Assembly &Cage

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

2400W APS INT Series 24VDC 230V Inverter/Charger with Auto-Transfer Switching, Hardwired

PQube 3 Modbus Interface

Cisco Nexus 7700 Switches Environment

SPARC T4-4 Server with. Oracle Database 11g Release 2

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Remote Monitoring System

PRODUCT PORTFOLIO. Electric Vehicle Infrastructure ABB Ability Connected Services

Smart-UPS: legendary uninterruptible power. Intelligent, reliable protection for servers and networks

Audio Operator Interface Installation Instructions

Master MPS kva kva 3:1 3:3 VFI TYPE

UKSM: Swift Memory Deduplication via Hierarchical and Adaptive Memory Region Distilling

Global EV Charging Stations will rise by 2020

Up to 98% efficient under full load Similar runtimes to the previous 3u model

Smart-UPS: legendary uninterruptible power. Intelligent, reliable protection for servers and networks

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

CHEMICALS AND REFINING. ABB in chemicals and refining A proven approach for transforming your challenges into opportunities

Differential Pressure and Flow meters Accessories for the Media Series

Smart-UPS with APC SmartConnect Maintain business certainty with intelligent network power protection

Chassis Profiles and Templates

Unleash the Power of Enterprise DNS

Price List Flexible Engine

Uninterruptible Power Supplies

PRELIMINARY COMPEX SYSTEMS

Security. Hardware Specifications. Editor: Stephen Satchell. Version Security Hardware Specification version i Copyright 2012 INE, Inc.

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

RS485 MODBUS Card. User Manual. Before you start to install this card, please read this User Manual carefully

Direct Communication Module

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

UPS Multi Power 1-28 x 42 kw up to 1MW

3000W APS X Series 24VDC 230V Inverter/Charger with Pure Sine-Wave Output, Hardwired

Uninterruptible Power Systems

1. Definitions. 2. Purpose of the document. 3. Price grids

40G QSFP+ (MPO) to 4x10G SFP+ (8xLC) Assembly

SFP Fiber Optic Transceivers

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

Note: If anything is damaged or missing, contact your customer representative immediately.

JMS Performance Comparison Performance Comparison for Publish Subscribe Messaging

ATC Series XFP CP Active Transceiver Cooler

Cisco Power Calculator -Power Results

3 Uninterruptible Power Systems

MAPNET II Transceiver Installation Instructions

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

PowerChute TM Network Shutdown v3.1. User Guide. VMware

Network Installation. July 2008 CONTENTS

Videosystem CAR-READER

Sola/Hevi-Duty S3K Series Mini-Tower UPS

PRODUCT DESCRIPTIONS AND METRICS

APM30 System Description

INVERTER/CHARGERS Off-Grid Power Solutions

MODEL NUMBER: APS750. Highlights. Package Includes. Description

MiniLab EL Series for High Performance Engine Development and Maintenance

DOPPLER PARKING SYSTEMS

MIMO Zen Series. Dual Band 2x2 MIMO ac/b/g/n Enterprise Indoor Access Point 560MHz CPU / 2.4GHz at 300Mbps / 5GHz at 867Mbps

MODEL NUMBER: APS2424

825-P Modular Protection System for motors Specification Guide

MODEL NUMBER: APS2012

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Transcription:

Specification Sheet SteelCentral Product Family Specifications Riverbed SteelCentral NetProfiler Solutions Product Specifications SteelCentral NetProfiler 7, 8, 9 SCNP-04270 Series Model SCNP-02270 Series 6 SCNP-04270 Series 7, 8, 9 Expansion Configuration F1 F2 F3 F4 F5 SCNP-04270-UI SCNP-04270-DB SCNP-04270-AN SCNP-04270-EX SCNP-04270-DP Deduplicated Flow Capacity 200,000 400,000 600,000 800,000 1,000,000 N / A N / A 1,000,000 1,000,000 N / A (flows per minute) 1 Raw Flow Capacity (flows per minute) 10 2,000,000 4,000,000 6,000,000 8,000,000 10,000,000 N / A N / A 10,000,000 10,000,000 N / A Disk Capacity 2 24TB 960GB 960GB 48TB 48TB 2TB Optional Fiber Channel SAN - - - Support 3 RAID RAID 1 / RAID 10 RAID 1 RAID 1 RAID 1 / RAID 10 RAID 1 / RAID 10 RAID 1 Front-Swappable Disks 4 12 2 2 12 12 2 RAM 64GB 64GB 64GB 64GB Serial Port (RJ-45 connector) Primary SteelCentral Management Port (10/100/1000 RJ45) Flow as Data Source 5 Requires SteelCentral Flow Gateway 1. Flow Capacity can be expanded up to the amount listed. 2. Raw Disk Capacity does not not take into account disk formatting, RAID overhead, software installation, or OS usage. 3. With purchase of NIC-1-HBA-2FC. 4. Hot swappable disks. 5. Accepts NetFlow (V1, V5, V7 and V9), Enhanced NetFlow, IPFIX, cflow, Cisco NBAR and NBAR2, Cisco MediaNet,Cisco ASA NSEL, Citrix AppFlow, sflow V2 and V5, J-Flow, Packeteer FDR, Palo Alto Networks, and SteelFlow from SteelHead, NetShark, AppResponse, and SteelConnect appliances. 6. Each Flow Gateway model can report to up to two NetProfilers and forward flow to two third-party flow collectors. 7. SCNP-4270-AN/EX equipped with RAID 1 / RAID 10 (48TB); SCNP-4270-UI/DB equipped with RAID 1 (960GB SSDs). 8. CNP-4270-AN/EX equipped with 12 front-swappable; SCNP-4270-UI/DB equipped with two front-swappable disks. 9. SCNP-4270 system includes-scnp-4270-ui, SCNP-4270-DB, and SCNP-4270-AN. Up to 19 SCNP-4270-EX expansion modules may be added to each SCNP-4270 system. Each additional SCNP-4270-EX adds 1M de-duplicated FPM. Maximum of 20M de-duplicated flows/min supported with version 10.11. SCNP-4270-DP is required with addition of fifth SCNP-4270-EX. 10. A flow reported by a single network interface is a raw flow. NetProfiler will de-duplicate up to 10 individual interfaces reporting the same flow into 1 de-duplicated flow.

SteelCentral NetProfiler Solutions Product Specifications SteelCentral Flow Gateway 11, 12 Model SCFG-02270 Series Configuration F1 F2 F3 F4 F5 F6 F7 12 Flow Capacity (flows per minute) 1 200,000 400,000 600,000 800,000 1,000,000 2,000,000 3,000,000 Raw Flow Capacity 2,000,000 4,000,000 6,000,000 8,000,000 10,000,000 20,000,000 30,000,000 Disk Capacity 2 2TB Optional Fiber Channel SAN Support 3 - RAID RAID 1 Front-Swappable Disks 4 2 RAM Serial Port (RJ-45 connector) Primary SteelCentral Management Port (10/100/1000 RJ45) Flow as Data Source 5 SteelCentral NetProfiler Model SCNP-02270 Series 6 SCNP-04270 Series 7, 8, 9 SCNP-04270 Series 7, 8, 9 Expansion Configuration F1 F2 F3 F4 F5 SCNP-04270-UI SCNP-04270- DB SCNP-04270- AN SCNP-04270-EX SCNP-04270-DP Dual Power Supplies (redundant) 14 Power [Watts] (typical) 305W 128W 308W 308W 128W BTU 1039 435 1049 1049 435 Temperature 15 Relative Humidity (shipping) Operating Acoustic Noise (typical) 10-35 C (50-95 F) 50-90%, non-condensing with a maximum wet bulb of 28 C (at temperatures from 25-35 C) 7.0 BA (operating condition in typical office ambient temperature: 23 +/- 2 C) Rack Size 2U 1U 1U 2U 2U 1U System Dimension (L x W x H) 16 707.8 mm (L) x 438 mm (W) x 87.6 mm (H) 27.87 (L) x 17.24 (W) x 3.45 (H) 640.43 mm (L) x 438 mm (W) x 43.2 mm (H) 25.21 (L) x 17.24 (W) x 1.7 (H) 707.8 mm (L) x 438 mm (W) x 87.6 mm (H) 27.87 (L) x 17.24 (W) x 3.45 (H) 640.43 mm (L) x 438 mm (W) x 43.2 mm (H) 25.21 (L) x 17.24 (W) x 1.7 (H) Packaging Dimensions 914.4 mm (L) x 609.6 mm (W) x 355.6 mm (H) 36 (L) x 24 (W) x 14 (H)) 914.4 mm (L) x 609.6 mm (W) x 330.2 mm (H) 914.4 mm (L) x 609.6 mm (W) x 330.2 mm (H) 914.4 mm (L) x 609.6 mm (W) x 330.2 mm (H) Weight (without packaging) 54 lbs 24 lbs 24 lbs 54 lbs 54 lbs 27 lbs Rail Information Mounting rail kit included Orderable spare part numbers: RMK-1-VRAIL, RMK-1-PRAIL RoHS Compliant 11. Requires compatible SFPs. 12. Flow rates shown are available with Flow Gateway 10.0.5 and later releases. Earlier versions had flow limits of 100,000, 200,000, 500,000, 800,000 and 1,400,000 respectively. 13. Requires version 10.9 or higher. 14. 1U models PS are rated for 450W, 2U models PS are rated for 750W. 15. Operating altitude up to 10,000 feet. 16. Length is without bezel, rack ears, cables. The availability, export or re-export of these products or specific features are subject to the export laws and regulations of the U.S. and the laws and regulations of any applicable foreign agency or authority. SteelCentral Product Family 2

SteelCentral NetProfiler Solutions SteelCentral Flow Gateway Model SCFG-02270 Series Configuration F1 F2 F3 F4 F5 F6 F7 Dual Power Supplies (redundant) 13 Power [Watts] (typical) 117W BTU 398 Temperature 14 Relative Humidity (shipping) Operating Acoustic Noise (typical) Rack Size System Dimension (L x W x H) 15 Packaging Dimensions Weight (without packaging) Rail Information RoHS Compliant 10-35 C (50-95 F) 50-90%, non-condensing with a maximum wet bulb of 28 C (at temperatures from 25-35 C) 7.0 BA (operating condition in typical office ambient temperature: 23 +/- 2 C) 1U 640.43 mm (L) x 438 mm (W) x 43.2 mm (H) 25.21 (L) x 17.24 (W) x 1.7 (H) 914.4 mm (L) x 609.6 mm (W) x 330.2 mm (H) 26 lbs Mounting rail kit included Orderable spare part numbers: RMK-1-VRAIL, RMK-1-PRAIL SteelCentral Product Family 3

SteelCentral NetShark and SteelCentral AppResponse 11 Solutions Model Specifications SteelCentral NetShark and SteelCentral AppResponse 11 Model 2170 4170 6170 8170 Storage Units (for Model 6170 only) 48TB Storage Unit 72TB Storage Unit Product SKU SCAN-02170 SCAN-04170 SCAN-06170 SCAN-08170 SCAN-SU-48TB SCAN-SU-72TB Storage 8TB 32TB None (requires attached SCAN-SU-48TB or SCAN-SU-72TB storage unit) None (requires at least two SCAN-SU-48TB or one SCAN-SU-72TB storage unit) 48TB 72TB Supported Storage Units N / A N / A Up to 8 1 Up to 16 1 N / A N / A Maximum Storage Capacity 8TB 32TB 576TB 1152TB 48TB 72TB Capture Disk Capacity 2 2 x 4TB 8 x 4TB N / A N / A 12 x 4TB 12 x 6TB Capture Disk Redundancy SW RAID level 0 HW RAID level 0 (default), 5, 6 N / A N / A HW RAID level HW RAID level 0 (default), 5, 6 5 0 (default), 5, 6 Operating System Disk Capacity 3 2 x 2TB 4 x 2TB 4 x 2TB 4 x 2TB N / A Operating System Disk Redundancy N / A Operating System customized Linux-based OS N / A RAM (GB) 32 64 128 N / A Available Network Interface Card Slots 1 2 2 N / A Available Capture Ports (max) 4 4 x 1GbE (copper or fiber) or 2 x 10GbE (fiber) 8 x 1GbE (copper or fiber) or 8 x 10GbE ports (fiber) or 4 x 1GbE (copper or fiber) + 4 x 10GbE (fiber) 8 x 1GbE (copper or fibre) or 8 x 10GbE ports (fibre) or 4 x1gbe + 4 x 10GbE (fibre) or 2 x 40GbE (fibre) N / A Management Port (10/100/1000 RJ45) 2 2 N / A 1. All Storage Units on an individual model 6170 or 8170 must be of the same capacity. 2. Raw Disk Capacity. 1TB = 10^12 Bytes. It does not not take into account disk formatting or RAID overhead. 3. Raw Disk Capacity. 1TB = 10^12 Bytes. It does not not take into account disk formatting or OS usage. 4. Supported NICs- 1GbE-quad port copper; 1GbE-quad port fibre; 10GbE-dual port fibre, 10GbE-quad port fibre, 40GbE-dual port fibre. 40G fibre ports are available with SR4 and LR4 QSFP inserts. 10G fibre ports are available with SR and LR SFP+ inserts (LC connectors). 1G fibre ports are available with SX and LX SFP inserts (LC connectors). 5. RAID 6 is not an option for the model 8170 when metrics priority storage mode is selected. SteelCentral Product Family 4

SteelCentral NetShark and SteelCentral AppResponse 11 Solutions SteelCentral NetShark and SteelCentral AppResponse 11 Solutions Model 2170 4170 6170 8170 Storage Units (for Model 6170 only) 48TB Storage Unit 72TB Storage Unit Product SKU SCAN-02170 SCAN-04170 SCAN-06170 SCAN-08170 SCAN-SU-48TB SCAN-SU-72TB Dual Power Supplies (redundant) Power [Watts] (typical) 135W 318W 259W 420W 217W 254W BTU 458 1082 881 1432 737 865 Line Power Requirements Operating Temperature 6 Humidity (shipping) 90-132V and 180-264V 47-63Hz 10-35 C (50-95 F) 50-90%, non-condensing with a maximum wet bulb of 28 C (at temperatures from 25-35 C) Rack Size 1U 2U 2U 2U 2U 2U System Dimensions (L x W x H) 7 640.43 mm (L) x 438 mm (W) x 43.2 mm (H) 25.21 (L) x 17.24 (W) x 1.7 (H) 707.8 mm (L) x 438 mm (W) x 87.6 mm (H) 27.87 (L) x 17.24 (W) x 3.45 (H) 640.3 mm (L) x 438 mm (W) x 87.6 mm (H) 25.21 (L) x 17.24 (W) x 3.45 (H) Packaging Dimensions (L x W x H) 8 914.4 mm (L) x 609.6 mm (W) x 330.2 mm (H) 914.4 mm (L) x 609.6 mm (W) x 355.6 mm (H) 36 (L) x 24 (W) x 14 (H) Max Weight (without packaging) 29 lbs 53 lbs 42.5 lbs 43.5 lbs 46 lbs Rail Information 9 RoHS Compliant Mounting rail kit included Orderable spare part numbers: RMK-1-VRAIL, RMK-1-PRAIL SteelCentral NetShark Virtual Edition Model VSK-00050 VSK-00200 VSK-00400 Product Storage Up to 50GB Up to 1TB Up to 2TB Hypervisor VMware ESXi 5.0, 5.1, 5.5, and Microsoft Hyper-V Server 2012 R2 vcpu 2 Memory 2GB 30GB Capture Ports Up to 4 Management Ports 2 6. Operating altitude up to 10,000 feet. 8. Packaging dimensions do not include the pallet on which the unit might be shipped. 7. Length is without bezel or cables. 9. The included rails fit square hole and un-threaded round hole racks. The availability, export or re-export of these products or specific features are subject to the export laws and regulations of the U.S. and the laws and regulations of any applicable foreign agency or authority. SteelCentral AppResponse 11 Virtual Model Specifications Model VSCAN-00100 VSCAN-00500 VSCAN-02000 VSCAN-FLOW Secondary Storage Up to 100GB Up to 2TB Up to 8TB Up to 100GB Hypervisor VMware ESXi 5.5 and 6.0 vcpu 4 Memory 8GB 100GB Capture Ports Up to 8 Management Ports 2 SteelCentral Product Family 5

SteelCentral NetShark Solutions SteelCentral NetShark on SteelHead EX Model LIC-RPM-560 LIC-RPM-760 LIC-RPM-1160 LIC-RPM-1260 LIC-RPM-1360 SteelHead EX Model 560 760 1160 1260 1360 SteelHead EX Release SteelHead EX 3.1 or later vcpu 2 Memory Capture Ports 2GB 30GB Up to 2 (AUX, Primary) SteelCentral NetShark Virtual on SteelFusion Edge Model SCAN-SFED-0020 SCAN-SFED-0030 SCAN-SFED-0040 SteelFusion Edge Model 2100 and 2200 3100 3200 and 5100 SteelFusion Release SteelFusion 4.0 vcpu 2 Memory Capture Ports 2GB 30GB Up to 2 (AUX, Primary) SteelCentral NetExpress Model Specifications SteelCentral NetExpress Model SCNE-00470 Configuration F1 F2 F3 F4 F5 Flow Capacity (flows per minute) 1 15,000 30,000 60,000 90,000 120,000 Raw Flow Capacity 8 150,000 300,000 600,000 900,000 1,200,000 System Disk Capacity 2 Capture Disk Capacity 3 8TB 4TB RAID RAID 1 / RAID 0 Front-Swappable Disks 3 4 RAM Serial Port (RJ-45 connector) Available Traffic Monitoring/Packet Capture Ports Primary SteelCentral Management Port 4 (10/100/1000 RJ45) Flow as Data Source 7 4-port 1GbE copper or 4-port 1GbE fiber SFP or 2-port 10GbE fiber SFP+ 6 1. Flow capacity can be expanded up to the amount listed. 2. Raw Disk Capacity does not not take into account disk formatting, RAID overhead, software installation, or OS usage. 3. Hot swappable disks. 4. 1000/Full connection required in some configurations. 5. Packet Analyzer is to access packet data captured by the NetExpress appliance and one concurrent license is included with the appliance for this purpose. 6. Requires compatible SFP (SX, LX)/SFP+(SR, LR) inserts. 7. Accepts NetFlow (V1, V5, V7, and V9), Enhanced NetFlow, IPFIX, cflow, Cisco NBAR and NBAR2, Cisco MediaNet, Cisco ASA NSEL, Citrix AppFlow, sflow V2 and V5, J-Flow, Packeteer FDR, Palo Alto Networks, and SteelCentral Flow from SteelHead appliances. 8. A flow reported by a single network interface is a raw flow. NetProfiler will de-duplicate up to 10 individual interfaces reporting the same flow into 1 de-duplicated flow. SteelCentral Product Family 6

SteelCentral NetExpress Model SCNE-00470 5 Due Power Supplies [redundant, 450 Watts] Power [Watts] (typical) 135W BTU 458 Temperature 9 Relative Humidity (shipping) Operating Acoustic noise (typical) Rack Size System Dimensions (L x W x H) 10 Packaging Dimensions Max Weight (without packaging) Rail Information Flow as Data Source 7 10-35 C (50-95 F) 50-90%, non-condensing with a maximum wet bulb of 28 C (at temperatures from 25-35 C) 7.0 BA (operating condition in typical office ambient temperature: 23 +/- 2 C) 1U 640.43 mm (L) x 438 mm (W) x 43.2 mm (H) 25.21 (L) x 17.24 (W) x 1.7 (H) 914.4 mm (L) x 609.6 mm (W) x 330.2 mm (H) 29 lbs Mounting rail kit included Orderable spare part numbers: RMK-1-VRAIL, RMK-1-PRAIL SteelCentral NetProfiler Virtual Edition System Requirements SteelCentral NetProfiler Virtual Edition Configuration F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 Flow Capacity 15,000 30,000 60,000 90,000 200,000 400,000 600,000 800,000 1,000,000 2,000,000 3,000,000 Raw Flow Capacity 150,000 300,000 600,000 900,000 2,000,000 4,000,000 6,000,000 8,000,000 10,000,000 20,000,000 30,000,000 Hypervisor vcpu 4 CPUs minimum 4 CPUs 8 CPUs 8 CPUs 8 CPUs 12 CPUs 12 CPUs 16 CPUs 2.6GHz 2.6GHz 2.6GHz RAM 8GB 12GB 12GB 16GB 16GB 48GB 48GB 64GB 64GB 96GB 250GB 250GB 250GB Flow Storage Space 250GB 50TB maximum 150 Flow Storage IOPS 11 500+ 500 2,000+ 1,000 4,000+ 2,000 6,000+ 2,500 7,500+ 3,000 9,000+ Management Ports 2 2 2 2 2 9. Operating altitude up to 10,000 feet. 10. Length is without bezel, rack ears, cables. 11. IOPS is defined as random read input/output operations per second. The availability, export or re-export of these products or specific features are subject to the export laws and regulations of the U.S. and the laws and regulations of any applicable foreign agency or authority. SteelCentral Product Family 7

SteelCentral Flow Gateway Virtual Edition, and SteelCentral NetExpress Virtual Edition System Requirements SteelCentral Flow Gateway Virtual Edition Configuration F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 Flow Capacity 15,000 30,000 60,000 90,000 200,000 400,000 600,000 800,000 1,000,000 2,000,000 3,000,000 Raw Flow Capacity 150,000 300,000 600,000 900,000 2,000,000 4,000,000 6,000,000 8,000,000 10,000,000 20,000,000 30,000,000 Hypervisor vcpu 2 CPUs minimum 2 CPUs 4 CPUs 4 CPUs 4 CPUs 8 CPUs 6 CPUs 8 CPUs 2.6GHz 2.6GHz 2.6GHz RAM 2GB 4GB 4GB 8GB 8GB 16GB 16GB 24GB 24GB 48GB 50GB Flow Storage 50GB Management Ports 2 2 2 2 2 SteelCentral NetExpress Virtual Edition Configuration F1 F2 F3 F4 F5 Flow Capacity 15,000 30,000 60,000 90,000 120,000 Raw Flow Capacity 150,000 300,000 600,000 900,000 1,200,000 Hypervisor vcpu 4 CPUs 8 CPUs 2.6GHz RAM 8GB 16GB 16GB Flow Storage Packet Storage Space 350GB 250GB 4TB maximum 250GB 4TB maximum Management Ports 2 About Riverbed Riverbed Technology, Inc. enables organizations to modernize their networks and applications with industry-leading SD-WAN, application acceleration, and visibility solutions. Riverbed s platform allows enterprises to transform application and cloud performance into a competitive advantage by maximizing employee productivity and leveraging IT to create new forms of operational agility. At more than $1 billion in annual revenue, Riverbed s 28,000+ customers include 97% of the Fortune 100 and 98% of the Forbes Global 100. Learn more at riverbed.com. 2018 Riverbed Technology, Inc. All rights reserved. Riverbed and any Riverbed product or service name or logo used herein are trademarks of Riverbed Technology. All other trademarks used herein belong to their respective owners. The trademarks and logos displayed herein may not be used without the prior written consent of Riverbed Technology or their respective owners. MS-117_SC_SS_US_010318