OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Similar documents
OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

Self-Priming Centrifugal Pumps

OWNER S MANUAL CP, CB SERIES CENTRIFUGAL PUMP

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

Vertical Jet Pumps. SSJ Series. Call OWNER S MANUAL

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

Model B1-1/2XQBS-11. Model B1-1/2XQBS-18. Model B1-1/2XQBS-26

MS Series. Call Multi-Stage Deep Well Jet Pumps. For further operating, installation, or maintenance assistance:

SUBMERSIBLE SWIMMING POOL DRAINER

SAE Engine Mount. Selection For Pumping Application. Matching Pump End To Engine. Type B Centrifugal Pumps Close coupled pump ends.

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

6 and 8 HAIR AND LINT STRAINERS

Submersible Solids Handling Pumps

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

SN Series / Série SN / Serie SN HN Series / Série HN / Serie HN

Heater Manifold REPLACEMENT INSTRUCTIONS. Sta-Rite Pool/Spa Group. 293 Wright Street, Delavan, WI 53115

ESE Series Cast Iron Sewage Pumps

Series FP4100. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

Models 3305P, 3307P, 3310P

HALLMARK INDUSTRIES INC

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Call DS3 Series. Installation/Operation/Parts For further operating, installation, or maintenance assistance:

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

SP40 Submersible Sewage Ejector Pump

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

SHEF30 Submersible Sump/ Effluent Pump

Submersible Sewage Ejector Pump

D SERIES CENTRIFUGAL PUMPS WITH TRAP FOR SWIMMING POOL USE

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

SHALLOW WELL JET PUMP

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

Self-Priming Horizontal Three and Four Stage Pumps

Flotec Pumps FP Click here for Pricing/Ordering for Pumps and Parts MOD. FP5230. Installation/Fonctionnement/Pièces

6TSP Series Radial Flow

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

OWNER s MANUAL Signature 2000 High Pressure Booster Pump 60 Hz. 1/2 through 3 HP

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS

STAR STOP SHALLOW WELL JET PUMP

INSTALLATION AND SERVICE MANUAL MSKV50 Submersible Sewage Ejector Pump

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY

5PNP15H. Call Installation/Operation/Parts For further operating, installation, or maintenance assistance:

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

NECO Pumping Systems

Installation Manual DIAPHRAGM WELL TANK

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

AUTOMATIC SUBMERSIBLE UTILITY PUMP

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG BUNN-O-MATIC CORPORATION

Installation & Operating Manual

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

HN series. cast iron shallow well jet pumps. 1/2 thru 1 HP

Artesian Owners Manual

Pump Installation and Service Manual HRS Hydromatic Retractable System

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

SPC-PANEL Simplex, Single Phase Pump Control Panel

TPHK Series Immersible Pump

SUBMERSIBLE SUMP PUMPS

SUNC3000 / Item #40885

Owner s Manual GLASSLINED PUMP TANK

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

StormPro BA Series Sump Pump

INSTALLATION AND OPERATION MANUAL. In-Line Centrifugal Pumps - Series: GB

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

OPERATOR S MANUAL. MODEL ORDER # MODEL HD 2.0/10 Ed HE D HD 1.8/14 Ed HE D

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

Operating Instructions and Parts Manual AHR-50 Auto Rewind Hose Reel

Posi Clear TM Cartridge Filters Models PXC75, PXC95, PXC125 and PXC150

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

Extension Hopper Installation & Operator s Instruction Manual for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Matala. VersiFlow Series. Instruction and Maintenance Manual

SUBMERSIBLE SUMP PUMPS

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Colt Series C400, C500

IMPORTANT SAFETY INSTRUCTIONS

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

SUPER PUMP OUT SYSTEM

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Above Ground Cartridge Filters Models PRC50, 5PRC50, PRC75 and 5PRC75

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

OWNER S MANUAL CONVERTIBLE JET PUMP

MODEL G300 Brake Bleeder

TPAK Series COOLANT PUMP

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose:

OWNER S MANUAL Submersible Sewage Ejector Pumps

MetroPrime 22MPC Self-Priming Centrifugal Pump

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Transcription:

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST Horizontal Multi-Stage Jet Pumps HMS-1FL Series MODELS 3/4 HP 1 HP 1-1/2 HP HMSD-1FL HMSE-1FL HMSF-1FL STA-RITE INDUSTRIES 293 Wright St., Delavan, WI 53115 2005 S1002 (Rev. 3/4/09)

Deep Well Installation Under certain conditions, horizontal multistage pumps can develop extremely high pressure. Install a pressure relief valve capable of passing entire pump flow at 75 PSI. Do not allow pump, pressure tank, piping, or any other system component containing water to freeze. Freezing may damage system, leading to injury or flooding. Allowing pump or system components to freeze will void warranty. NOTICE: Support pump base to avoid strain on casing adapter or pump. Lack of support can damage adapter or pump. Figure 2 shows casing adapter bolted directly to pump body. 278 1093 Pipe fittings not furnished Regulator 1" Close nipple & 90 Elbow To Service Drain Plug Priming Regulator Adjusting Priming Plug Plastic Pipe Adapter (2) Hose Clamp (2) Plastic Hose (2) Drive Line Suction Line Shallow Well Installation NOTICE: If no foot valve is used, install 1 check valve in horizontal line. Priming the Deep Well Pump To prime pump, completely close the priming valve located just below the suction opening by turning screw clockwise. This valve will be left closed during operation in a deep well installation. See Figure 1. Close regulator adjusting valve, located on end of regulator, by turning stem clockwise. See Figure 1. Remove priming plug from top of regulator valve, see Figure 1, and fill with clean water. Replace plug. Start pump and run a few moments. If pressure does not build up, remove priming plug and refill with more water. All of the trapped air in pump body was not removed. Restart pump. When pump is completely primed and builds up pressure, slowly open the regulator valve, (turn counter-clockwise), and observe the pressure reading on the pressure gauge. When the pump reaches a point where it will lose prime, cavitation noise can be heard. The best, or correct, pressure gauge setting is approximately 3 pounds higher than the pressure gauge reading was when the pump started to lose prime. If pump loses prime, repeat the priming procedure above and this time open regulator valve only until the correct pressure reading is reached. If a vacuum gauge is available, screw it into the 1/8 AVC tapping on front of tank body. Adjust regulator until 20 of vacuum is registered on the gauge. Tighten locknut on regulator. This method will give maximum performance of the unit. Figure 1 Deep Well Installation Priming Plug Regulator Priming Plug & 1/2" Street Elbow To Service To Service 1" Pipe Plug Plastic Pipe Adapter Hose Clamp Plastic Hose 279 1093 240 1093 Priming From Well Pipe fittings not furnished Figure 2 Well Casing Adapter bolted directly to pump Figure 3 Shallow Well Installation 2

HMSC pumps come equipped with pressure switch set to operate within a 20-40 PSI range. HMSD, HMSE, and HMSF pumps have 30-50 PSI pressure switches. When pump is used with precharged tank in system, set tank pre-charge at 18 PSI with a 20-40 PSI switch; set tank pre-charge at 28 PSI with a 30-50 PSI switch. Check tank pre-charge annually with an ordinary tire gauge. Pre-charge is set with no water pressure on system. Priming the Shallow Well Pump Never run pump dry. Running pump without water may cause pump to overheat, damaging seal and possibly causing burns to persons handling pump. Fill pump with water before starting. Service Draining for Winter Do not touch an operating motor. Modern motors are designed to operate at high temperatures. To avoid burns when servicing pump, allow it to cool for 20 minutes after shut-down before handling. When the pump is to be disconnected from service, or is in danger of freezing, it should be drained. The pump has a drain plug which must be removed. Remove the priming plug to vent the pump. If pump and motor are damaged due to freezing, the Warranty is void. Never run pump against closed discharge. To do so can boil water inside pump, causing hazardous pressure in unit, risk of explosion and possibly scalding persons handling pump. To prime the pump, completely open the priming valve located just below the suction opening on the tank body by turning the valve stem counter-clockwise all the way until it stops. This valve may be left open during operation as a shallow well pump with no jet. See Figure 3 and NOTICE below. Remove priming plug from top of elbow (see Figure 3), and fill with clean water. Replace plug. Start pump and between 45-60 seconds. If water is not being pumped, turn off pump and repeat priming process. NOTICE: If a bolt-on jet is being used, after pump is primed, close the priming valve during operation as a shallow well pump. TABLE I Recommended Fusing and Wiring Data 60 Cycle Motors DISTANCE IN FEET FROM MOTOR TO METER BRANCH 0 101 201 301 401 MAX. FUSE* to to to to to MOTOR LOAD RATING 100 200 300 400 500 HP VOLTS AMPERES AMPS WIRE SIZE 3/4 115 14.8 20 12 8 6 6 4 3/4 230 7.4 15 14 14 14 12 10 1 115 19.2 25 10 8 6 4 4 1 230 9.6 15 14 14 12 10 10 1-1/2 115 24.0 30 10 6 6 4 3 1-1/2 230 12.0 15 14 14 12 10 10 *Fusetrons are recommended instead of fuses on all motor circuits. 3

Electrical Disconnect power before working on pump, motor, pressure switch, or wiring. MOTOR SWITCH SETTINGS Your motor terminal board (located under the motor end cover) should look like one of those below. If the motor can operate at either 115 or 230 volts, it is set at the factory to 230 volts. Do not change motor wiring if line voltage is 230 volts, or if you have a single voltage motor. Never wire a 115 volt motor to a 230 volt line. Plug Type Voltage Selector Dial Type Voltage Selector Power Supply Connections Power Connections Voltage Change Plug Voltage Change Dial Pressure Switch Ground Wire Connection Pressure Switch Ground Wire Connection Figure 4: Voltage set to 230 volts, Plug Type Figure 6: Voltage set to 230 volts, Dial Type Voltage is factory set to 230 volts. To change to 115 volts: 1. Make sure power is off. 2. Pull the voltage change plug off of the tabs. 3. Move the voltage change plug to the 115 volt position. The plug will now cover 2 metal tabs and the arrow on the plug will line up with the 115V arrow on the label (see Figure 5). Voltage is factory set to 230 volts. To change to 115 volts: 1. Make sure power is off. 2. Turn the dial counter-clockwise until 115 shows in the dial window as shown in Figure 7. Figure 7: Voltage set to 115 volts, Dial Type 3. Attach the incoming power leads to the two outer screws on the pressure switch as shown in Figure 6. 4. Attach the ground wire to the grounding connections as shown in Figure 6. 5. If there are other wires, they should be capped. 6. Reinstall the Motor end cover. Figure 5: Voltage set to 115 volts, Plug Type 4. Attach the incoming power leads to the two outer screws on the pressure switch as shown in Figure 4. 5. Attach the ground wire to one of the grounding connections, shown in Figure 4. 6. If there are other wires, they should be capped. 7. Reinstall the Motor end cover. 4

Hazardous voltage. Can shock, burn, or kill. Connect ground wire before connecting power supply wires. Use the wire size (including the ground wire) specified in the wiring chart. If possible, connect the pump to a separate branch circuit with no other appliances on it. supply line. WIRING CONNECTIONS Explosion hazard. Do not ground to a gas Fire hazard. Incorrect voltage can cause a fire or seriously damage the motor and voids the warranty. The supply voltage must be within ±10% of the motor nameplate voltage. NOTICE: Dual-voltage motors are factory wired for 230 volts. If necessary, reconnect the motor for 115 volts, as shown. Do not alter the wiring in single voltage motors. Install, ground, wire, and maintain your pump in compliance with the National Electrical Code (NEC) or the Canadian Electrical Code (CEC), as applicable, and with all local codes and ordinances that apply. Consult your local building inspector for code information. Connection Procedure: 1. Connect the ground wire first as shown in Figure 4. The ground wire must be a solid copper wire at least as large as the power supply wires. 2. There must be a solid metal connection between the pressure switch and the motor for motor grounding protection. If the pressure switch is not connected to the motor, connect the green ground screw in the switch to the green ground screw under the motor end cover. Use a solid copper wire at least as large as the power supply wires. 3. Connect the ground wire to a grounded lead in a service panel, to a metal underground water pipe, to a metal well casing at least ten feet (3M) long, or to a ground electrode provided by the power company or the hydro authority. 4. Connect the power supply wires to the pressure switch as shown in Figure 4. LIMITED WARRANTY STA-RITE warrants to the original consumer purchaser ( Purchaser or You ) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period Water Systems Products jet pumps, small centrifugal pumps, submersible pumps and related accessories Signature 2000 Fibrewound Tanks Pro-Source Plus TM Fibrewound Tanks Pro-Source TM Steel Pressure Tanks Pro-Source TM Epoxy-Lined Tanks Sump/Sewage/Effluent Products 5 whichever occurs first: 12 months from date of original installation, or 18 months from date of manufacture 5 years from date of original installation 5 years from date of original installation 5 years from date of original installation 3 years from date of original installation 12 months from date of original installation, or 18 months from date of manufacture Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void. Your only remedy, and STA-RITE s only duty, is that STA-RITE repair or replace defective products (at STA-RITE s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable. STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WAR- RANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state. This warranty supersedes and replaces all previous warranty publications. STA-RITE INDUSTRIES 293 Wright St., Delavan, WI 53115

EXPLODED VIEW 8 24 25 12A 23 26 11 12B 22 27 21 12 20 3 13 14 15 1 2 19 16 17 18A 4 18 6 5 7 8 9 10A 10 225 0993 10B 6

REPAIR PARTS KEY PART NO. HMSD-1FL HMSE-1FL HMSF-1FL NO. DESCRIPTION W/KIT USED 3/4 HP 1 HP 1-1/2 HP 1 Motor, 60 Hz, 115/230V - Single Phase 1 A700DH A700EH A700FH 1A Key - Shaft OH 2 U65-15SS U65-15SS U65-15SS 2 Water Slinger 1 17351-0009 17351-0009 17351-0009 3 Capscrew - 3/8 x 16 x 1 Hex Head 4 U30-74ZP U30-74ZP U30-74ZP 4 Seal Plate 1 L3-26 L3-26 L3-26 5 Gasket - Seal Plate OH/SG 1 L20-43 L20-43 L20-43 6 Shaft Seal OH/SG 1 U109-267 U109-267 U109-267 7 Spring Holder Washer OH/SG 1 J24-11 J24-11 J24-11 8 Impeller OH 2 L105-2PC L105-2PB L105-2P 9 Spacer - Impeller 1 J43-23 J43-23 J43-23 10 Diffuser Assembly w/wear Rings 1 L101-45 L101-45 L101-45 10A Wear Ring OH (1) L23-9 L23-9 L23-9 10B Wear Ring OH (1) P23-19 P23-19 P23-19 11 Stop Nut - Shaft OH 1 U36-175SSW U36-175SSW U36-175SSW 12 Diffuser Cover w/wear Ring 1 L103-27 L103-27 L103-27 12A Wear Ring (1) L23-9 L23-9 L23-9 12B Capscrew - 1/4-20 x 3 Lg. 3 U30-528SS U30-528SS U30-528SS 13 Diffuser Ring OH/SG 1 L21-1 L21-1 L21-1 14 Pipe Plug - 1/2 NPT 1 U78-59ZPS U78-59ZPS U78-59ZPS 15 Pressure Gauge 1 U239-8 U239-8 U239-8 16 Pump Body 1 L76-36 L76-36 L76-36 17 Pipe Plug - 1/8 NPT 1 U78-56ZPS U78-56ZPS U78-56ZPS 18 Assembly 1 01322 01322 01322 18A Gasket 1 L20-39 L20-39 L20-39 19 Plug - 1/4 NPT 1 U78-941ZPV U78-941ZPV U78-941ZPV 20 Base 1 U4-5 U4-5 U4-5 20A Lockwasher - 3/8 2 U43-12ZP U43-12ZP U43-12ZP 20B Capscrew - 3/8-16 x 5/8 Lg. 2 U30-71ZP U30-71ZP U30-71ZP 21 Capscrew - 3/8-16 x 7/8 Hex Head 8 U30-73ZP U30-73ZP U30-73ZP 22 Connector 1 L43-5C L43-5C L43-5C 23 Locknut - 1/2 1 U36-112ZP U36-112ZP U36-112ZP 24 Pressure Switch 1 U217-1216 U217-1216 U217-1217 25 Compression Fitting - Elbow - 1/4 1 U111-212T U111-212T U111-212T 26 Tube - Pressure Switch 1 U37-677P U37-677P U37-677P 27 Compression Fitting - Straight - 1/4 1 U111-100T U111-100T U111-100T Not shown. SERVICE KITS Seal and Gasket Kit 1 PP1625 PP1625 PP1625 Overhaul Kit 1 PP1631 PP1632 PP1633 NOTE: SG Included in Seal and Gasket Kit. OH Included in Overhaul Kit. 7

J212-24H Regulator EXPLODED VIEW 5 8 7 3 4 6 9 2F 2E 2G 2C 2D 2B 2 1A 2A 229 1093 1 REPAIR PARTS KEY PART PART NO. DESCRIPTION QTY. NUMBER Pressure Regulator Complete 1 Pkg. 107 1 Regulator Body w/seat 1 J112-14 1A Seat 1 J66-16 2 Diaphragm Assembly w/guide (Incl. 2A, 2B) 1 J220-16B 2A Guide 1 J42-5 2B Diaphragm Assembly (Incl. 2C, 2D, 2E, 2F, 2G) 1 J120-16 2C Stem 1 J62-9 2D Diaphragm 1 J20-16 2E Spring Follower 1 J43-31 2F Lockwasher 1 J43-23ZP 2G Nut 1/4-20 1 U36-36ZP 3 Spring 1 J24-13 4 Spring Guide 1 J61-5 5 Bonnet 1 J52-9 6 Capscrew 5/16-18 4 U30-60ZP 7 Hex Nut 5/16-18 1 U36-37ZP 8 Adjusting Screw 5/16-18 1 U30-665ZP 9 Pipe Plug 1/2 NPT 1 U78-59ZPS Compression Fitting 1/4 90 EL 1 U111-86T Tubing - Pressure Switch 1 U37-625P Not shown 8