FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System

Similar documents
FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System

Fuel Transfer Pumps DC Aluminum Gear Fuel Pump with Auto Nozzle

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.

ABOVEGROUND STORAGE TANK PRODUCTS CATALOG

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products 8 5 (VR-402-B) Single Wall Tank with Top Fill. 26 Alarm. Pressure Vacuum Vent

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products (VR-402-D) Single Wall Tank with Top Fill. 12 or 34. Pressure Vacuum Vent

RELIANCE G6200 MECHANICAL FLEET DISPENSER

LUBRICATION & FLUID HANDLING ACCESSORIES. Heavy duty knurled steel barrel with large threads for easy loading.

Model 1210C Battery Powered Pump Shown

NOW UL LISTED. Patented

Overfill Prevention Valve

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed.

1618 Mechanical Gauge Installation, Operation, and Maintenance Instructions

Fuel Dispensing & Accessory Packages

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

General information about underground storage tank (UST) fueling systems in every day language.

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Bottom Load Adaptors. API Adaptors 891 Series. API Bottom Loading Adaptor L

LD Series Electronic Meters

Tank Filling Systems for Petroleum Products

INSTALLATION INSTRUCTIONS

Clay & Bailey Mfg. Co.

Clay & Bailey Mfg. Co.

Emergency Shear Valves

SERVICE QUALITY PRODUCTS INNOV ATION CUST OM ASSEMBL Y ADVANCED PRODUCT TECHNOLOGY CATALOG

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

Portable Fuel Dispensing Equipment

Emco Logo on Scuff INSTALLATION INSTRUCTIONS

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

Model Model 815

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

12 Volt DC Diaphragm Pumps Series 400

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

AC 700 SERIES FUEL PUMPS Item code: FILLRITE-AC700

Operating instructions Form no safety definitions

Instructions Parts List

Stay-put scuff guard helps to protect the dispensers from scratches and the breakaway during a drive-off event

92021 Automatic Tank Gauge. Features. Automatic Tank Gauge. 1/16 Accuracy. 90 Foot gauging range. Simple installation. Ground or roof reading

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO

FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps

Fluid Dispensing Systems

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

OPW 400 and 500 Series Multi-Port Spill Containment Manholes. Model Descriptions. Features. Listings and Certifications

CAUTION: NOT INTENDED FOR STREET USE HOW TO USE THIS CATALOG WE LOVE RACING


Model Model Model 3650 Model 3614

Duplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, with Steel Cover

1/2" AIR DRIVEN DIAPHRAGM PUMP

funnels, measures, gravity cocks, jerry cans and oil suction pumps...

TECHNICAL DATA CAUTION

M-3025CB-AV Fuel Pump

Owner's Operation & Safety Manual SERIES 800C METER. For models 806C, 807C OUTSTANDING FEATURES

Reliance G6200 Mechanical Fleet Dispenser

Dual wall sub-base diesel fuel tanks -

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment.

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE

Informational Handbook

SELECT TM SERIES ELECTRONIC FLEET FUEL DISPENSERS

Control Valves/Meters Grease

12V DC FUEL PUMPS Item code: FILLRITE-12V

FR600G Series AC Transfer Pumps

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

Model 5000 Level Controller

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Farm & Residential Tanks Angle skids

IST INTELLIGENT SUBMERSIBLE TURBINE

Airless Sprayer. TriTech is PRECISION BUILT

Instructions for Installation, Operation, Care and Maintenance

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

Pro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203

HIGH PRESSURE SPRAYERS

Control Valves/Meters Grease

3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.

Congratulations PRE-OPERATION SETUP

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

Conventional Fueling 11A 11B. 1A Automatic Nozzle

SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

Polypropylene Piston Drum Pumps

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

Industrial Generator Set Accessories

Page 6-6. Page 6-3. Page 6-3. Page 6-5. Self- Educting Foam. Foam Compatible. Location

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

HIGH PRESSURE SPRAY GUNS &ACCESSORIES

Oil & Light Fluid Pumps

FUELTEC MODEL CF4.0. CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters)

CONTENTS. Foreword...iii. 1. Introduction...1

Instructions for Installation, Operation Care and Maintenance

Wet pipe low flow foam/water manifold system

Transcription:

FUEL DISPENSING SYSTEMS Component Details SE-47 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System 120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet 3-Wheel Mechanical Meter in Cabinet 1 Automatic Nozzle, Swivel & Hose 40 GPM Particulate Filter - 30 Micron 2 - Emergency Vents - MNPT - 16 oz Pop-up Leak Gauge Swing-arm or Clock Level Gauge Overfill Prevention Valve Atmospheric Vent with Pipe Drop Tube - Pump Suction Pipe - 3 Lift Spill Bowl or Remote Fill Minimum tank diameter 64 Proudly made in America

120V AC Electric Pump - 1-1/4" Inlet - 1" Outlet This Heavy Duty, positive displacement pump delivers up to 18 GPM (114 LPM) and is designed with Fill Rite's exclusive anti siphon safety feature. The motor is explosion proof UL/cUL listed and has sealed bearings, a heavy duty switch and thermal overload protection. The system is UL/cUL listed as well. For flexible and convenient applications, combine above ground pumps with Series 902 cabinet meters. Features & Benefits 20 GPM (76 LPM) 1/3 HP motor UL/cUL listed pump and motor Heavy duty cast iron construction Diesel, gasoline,. kerosene, E15, biodiesel up to B20 2 year warranty 2 in. threaded base for tank mounting

4-Wheel Mechanical Meter in Cabinet Fill Rite's FR902C model meter cabinets are constructed from heavy duty 15 guage steel and are powder coated to stand up to the harshest environments. Hood removal is quick and simple; remove three screws and the reset knob and you have access. The cabinet is pulser ready and all external wiring connections are placed in easy access locations. Features & Benefits 6 40 gpm 1 inlet / 1 outlet 4 digit mechanical gallon meter UL / cul certification For use with remote pumps Can be used with submersible pumps Replaces model FR902RU

1" Automatic Nozzle, Swivel & Hose, Gas & Diesel Fill a 200 gallon tank in less than 7 minutes. That's real time saved...every time you fill the tank. Industry leading flow isn't the only reward you will reap. The patent pending UL listed Ultra Hi Flow nozzle takes fuel transfer to a new level. For transfer of gasoline, diesel, or kerosene to large fuel capacity farm, fleet, or construction equipment, there is simply no better choice. Fueling has never been easier...or quicker. Don't let your nozzle slow up your work when it is most Features & Benefits UL listed for gasoline, diesel and kerosene 1 in NPT F inlet, 1 1/8 in OD spout Three position latch for automatic flow at 30, 24 and 8 GPM Angled outlet to minimize hose wear 50 PSI working pressure Heavy duty hanging hook compatible with all Fill Rite products Automatic shut off Convenient one finger hold open clip to set flow rate Rated to 20 Fahrenheit operation Insulated hand grip to minimize hot and cold handling Minimal spray pattern to reduce foaming and false shut offs Large spout spring to hold nozzle in place Viton seals and o rings for smooth valve operation Patent pending Made in USA

1" Swivel & Hose Model: S100H1315 Multi Plane, Full 360 spherical rotation for easy movement of the nozzle. Features & Benefits Double O ring Seals at each Swivel Provide Long Life at Low Temps ( 40 F/C) Compatible with Unleaded Gasoline, Diesel & Ethanol Blends through E10 Dispense Diesel Fuel, Gasoline, Grease Kerosene and Petroleum Oils. The Fill Rite hose is a blend of Nitrile and PVC external materials provides rugged protection against cuts, abrasions, snags. Puncture Resistant. Features & Benefits Dispense diesel fuel, gasoline, kerosene, and petroleum oils Neoprene exterior Designed for use with all electric pumps High quality Nitrile inner tube

40 GPM Particulate Filter - 30 Micron & Filter Head Particulate Fuel Dispenser Filter is designed with resin impregnated cellulose media for the removal of dirt, rust and microbes. Features & Benefits 30 Micron Filter 50 psi 40 gpm 1 1/2 16 Compatible with gasoline, diesel, ethanol blends up to 15% and ultra low sulfur diesel

Emergency Vents - MNPT - 16 oz UL Listed Emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire. Emergency vents must be used in conjunction with a normal vent. Correct application of this vent requires proper vent size and selection for the tank system in order to meet the specific venting capacity. Code Compliance: API 2000 International Fire Code National Fire Code of Canada NFPA 1, 30, 30A, 31, 37, 110 PEI RP200 & PEI RP800 Underwriters Laboratories Inc. - UL-142, UL-2085 & UL- 2244 Underwriters Laboratories of Canada - CAN/ULC S601-07, CAN/ULC S602-07 & CAN/ULC S652-08 California Air Resource Board (CARB) Phase 1 Enhanced Vapor Recovery (EVR) AST Certified Products (VR-402-B) Fig. 244OM WARNING: DO NOT FILL OR UNLOAD FUEL FROM A STORAGE TANK UNLESS IT IS CERTAIN THAT THE TANK VENTS WILL OPERATE PROPERLY. Emergency vents are designed only for use on shop fabricated atmospheric tanks which have been built and tested in accordance with UL 142, NFPA 30 & 30A, and API 650 and in accordance with all applicable local, state, and federal laws. In normal operation, dust and debris can accumulate in vent openings and block air passages. Certain atmospheric conditions such as a sudden drop in temperature, below freezing temperatures, and freezing rain can cause moisture to enter the vent and freeze which can restrict internal movement of vent mechanisms and block air passages. All storage tank vent air passages must be completely free of restriction and all vent mechanisms must have free movement in order to insure proper operation. Any restriction of airfl ow can cause excessive pressure or vacuum to build up in the storage tank, which can result in structural damage to the tank, fuel spillage, property damage, fire, injury, and death. Monthly inspection, and immediate inspection during freezing conditions, by someone familiar with the proper operation of storage tank vents, is required to insure venting devices are functioning properly before filling or unloading a tank.

Leak Gauge - Pop-Up for tanks 96" diameter and smaller Top mounted liquid leak gauge that can measure from 6" to 170" in depth. Gauges are custom made in house to fit your tank. This gauge is designed to monitor either the interstitial space of a double wall containment system, or it can mount into an external monitoring pipe. Calibration: Consists of 3 pieces. Outer plastic piece, inner plastic piece, and a piece of paper in between. Red Lock Nut: HDPE Plastic. This gauge is a simple visual tool. If the red indicator rises into the viewing window, it is indicating that there is a leak occurring in the double wall containment system. Bushing: Aluminum bushing, can be 2 or 1.5. Once installed, simply view the calibration to monitor the interstitial space. The indicator is not calibrated. It simply indicates leak or no leak. Internal Rods: Standard construction is aluminum rods. Additional Options Leak Union: Compression union Audible Alarm Accessory: This feature can turn the mechanical gauge into an audible Hi or Lo level alarm. Gauge Guard: A cover that protects the exposed plastic components on top of the gauge. Environmental Protection The Leak gauge is officially approved for use in double wall containment systems by several state environmental protection agencies. Float: HDPE Plastic

Leak Gauge - Electronic for 120" diameter tanks Engineering Bulletin

Level Gauge - Swing Arm for tanks 64" diameter and smaller Top mounted liquid level gauge that can measure from 6" to 170 in depth. This gauge is a simple volume reading tool. The top of the red indicator is an indication of approximate fuel level in the tank. Once installed, simply view the calibration to monitor tank level. Indicator is calibrated in eighths of a tank on one side, and quarters of a tank on the other. Calibration: Consists of 3 pieces. Outer plastic piece, inner plastic piece, and a piece of paper in between. Red Lock Nut: HDPE Plastic. Bushing: Aluminum bushing, can be 2 or 1.5. Gauges are custom made in house to fit your tank. Can also accommodate for double walls and pipe risers. HDPE Float: High Density Polyethylene Plastic. Additional Options Audible Alarm Accessory: This feature can turn the mechanical gauge into an audible Hi or Lo level alarm. LED At-A-Glance Accessory: This feature can give mechanical gauge remote reading capability. Gauge Guard: A cover that protects the exposed plastic components on top of the gauge. Internal Rods: Standard construction is galvanized steel rods with brass rivets. These replacement parts are available. Red HDPE Plastic Nut Duro Nitrile Gasket Plastic cellulose acetate inner and outer calibration Aluminum Lock Nut Glass inner calibration

Level Gauge - Clock-style for 72" and larger diameter tanks Features Gallon Ga Easy to install on a 2" female threaded tank opening Vapor tight up to 5 PSI Swivel base rotates 360 for optimum viewing angle Measures liquid levels up to 12' (3.6 meters) Proven anti-fog design High level indicated by red zone indicator Stainless steel fl oat and cable Drop tube float and drop tube available for tanks with higher-than-normal turbulence Compatible with ethanol blends up to 85% Compatible with biodiesel blends up to 100% Intrinsically safe alarm is battery powered Liter reading gauges available Includes field adjustable 90 decibel high level audible alarm Standard oat

Overfill Prevention Valve The overfill prevention valve is installed at the fill port of a storage tank. Used in a pressurized tight fill application, the valve helps prevent tank overfills by closing when the liquid level reaches a pre-set warning level (90-95% full). The valve is installed through a 4" or 6" threaded opening and has a built-in bleed hole that allows the fill hose pressure to be relieved after the valve closes. This bleed hole also provides anti-siphon protection for the valve. When installed to manufacturer requirements, the overfill prevention valve can eliminate hazardous liquid spills. The valve can be used in conjunction with AST spill containers or remote fill boxes for added spill protection. All models are supplied with an adaptor to mount an aluminum drop tube. A test mechanism is also sold separately if needed. The test mechanism allows a technician to pull on the test line at any time during the filling process to actuate the float and stop the filling process. This allows a technician to verify the valve is working properly. Features The 3" valve can be used with 6" Sch. 40 or 80 pipe. The 2" valves can only be used with 4" Sch. 40 pipe. Construction Details Anodized aluminum body Brass/stainless steel internal components Stainless steel linkage Failure to follow any or all of the warnings listed below may render the valve non-functional and could result in an accidental product spill, property damage, fire, explosion, injury or death. Warnings and Cautions 5 PSI & 5 GPM is the minimum flow requirement for valve operation. Valve will NOT function in gravity fill applications. Maximum viscosities (in centistokes): 2" Valve-150, 3" Valve-60. Flow rate of the 2" valve is 350 GPM maximum flow (183 GPM @ 10 PSI pressure drop). The 3" valve is 800 GPM maximum flow rate (566 GPM @ 10 PSI pressure drop). Once closed the valve will allow fl ow of less than 2% of max fl ow rate to relieve fill line pressure. A tight fill is required for the valve to operate. Do not substitute any other fill adaptors for the special adaptor supplied. The valve must be used with clean product. Debris from products such as contaminated used oil may cause the valve to function improperly. These valves are rated for a maximum pressure of 100 PSI. Not suitable for motor oil or other heavy oils. Consult Morrison Bros. Co. for product compatibility with the valve. Code Compliance ULC, NFPA 30, 30A, UFC, IFC and PEI /RP200, PEI /RP600, Florida DEP EQ356, CARB VR 402A

Drop Tube & Normal (Mushroom) Vent with Pipe The drop tube directs product flow to liquid level when filling a storage tank. The drop tube prevents free fill and reduces agitation of liquid when filling. The flanges fits between tight fill adaptor riser pipe. The tube extends to near bottom for submerged fill. All drop tubes are extruded aluminum. The 2 and 3 drop tubes can also be attached to the AST Overfill Prevention Valve. Drop tube length determined by tank diameter. Mushroom style free flow vent Stainless-steel mesh screen. Domed vent top prevents tank contamination from entering vent lines. NPT threads Cast iron, zinc plated 2" diameter galvanized steel vent pipe Length determined by tank volume/size

Remote Fill Port Spill capacity 10 gallons 14 gauge Stainless-steel construction Inlet and outlet available in 2" or 3" size Includes: Dust plug Quick disconnect - female Check valve Hand transfer pump Transfer hose with check valve and ball valve assembly Ball valve Outlet Mounting Brackets as needed 1" Drain fitting Hinged door wiht locking handle VR 4" aluminum adapter X 3" NPT VR 4" aluminum cam lever cap. 3" Stainless-steel full coupling 3" Stainless-steel nipple