introduction function electrical connection signal describtion parameter adjustment commissioning, mounting, safety items error codes

Similar documents
UWT Lot. Table of contents. Continuous level measuring system SLS 3000 Technical information / Instruction manual. Page

Continuous level measuring system NB 4000 Selection list

Level MONITORING. Continuous Level Measurement ILS

Continuous level measuring system NB 3000 Selection list

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/

Continuous level measuring system NB 3000 Selection list. Overview

Kondunivo Table of contents

Continuous Level Measuring System. LevelMax. Instruction Manual

Continuous level measuring system. LevelMax. Selection Guide. Overview 2

Nivobob 1. Table of contents. Continuous level measuring system NB 4000 Technical information / Instruction manual. Page

Capanivo Series CN 4000

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D

Operating Instructions. Angle Seat Control Valve. Type 7020

EPS/ELA-Series User Manual EPS/ELA 250W

Level limit switch Series RF 3000 Selection list

Compact System NRGS 11-2 NRGS Original Installation Instructions English

GP Rev a ( ) DCN0533

Level Limit Switch soliphant FTM 930/931/932/ Z


Rotary blade level indicators Level limit switches for bulk goods. Accessories

OPERATING INSTRUCTIONS. LEISTER Varimat V Hot Air Automatic Welding Machine

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4


DIAMOND POINT VIBRATING PROBES

Product information MBA200. A Level Indicator with Rotating Paddle for Bulk Material TYPE MAIHAK MADE IN GERMANY

FF03. Rotary Blade Level Switch for bulk goods. Level Measurement and Monitoring

Metal tube variable area flowmeter for gases, liquids and steam

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

35 35A 50 50A 1 Single phase. Solid state power controller

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

INSTALLATION GUIDE Ultrasonic Sensors Series UX micro

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description

7 Lighting Technology

Documentation. RM-BV4 Micro DP. Filter control

Operating instructions Binary level sensor LMT /00 06/2011

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Level Sensors and Switches Guided Radar (TDR) Radar Wave Level Sensors Ultrasonic Level Sensors Rotating Paddle Level Switches Vibrating Fork Level

TOWA SEIDEN INDUSTRIAL CO., LTD.

PKP Prozessmesstechnik GmbH Borsigstraße 24 D Wiesbaden-Nordenstadt Tel.: ++49-(0) Fax: ++49-(0)

Digital ph transmitter

CVR-625. Compact Vibrating Rod Instruction Manual

Positive displacement batch controller

Pressure chlorine changeover unit C 7520

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

ST Wiring diagram. Product description. Temperature controller. Order number

Electronic Ballast EVG 2000-T

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Level limit switch Series RN 4000 Selection list. Overview / Specification / Applications

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

VTZ variable speed Reciprocating compressors

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Thermal Overcurrent Circuit Breaker 3120-F...

GP50 Vibrating Fork Level Switch. Vibrating level switch for powders and granular solids K-TEK Products

POWER REGULATOR LD -40PSU

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

EXKOP MINI + QV II Quench Valve. Explosion Isolation System

Nominal sizes: DN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 Pressure rating: PN 16. Product No. Nominal size Body connection

Operating Instructions Pedestrian Turnstile Type MPT 33

Operating Instructions Type MPT 53

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

QS20.241, QS C1

1.0 Features and Description

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

CONA -control Monitoring system for steam traps

Electromagnetic Flow Monitor magphant

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

V5422L / V5422E ACTUATED BUTTERFLY VALVES. FEATURES With factory-mounted electric actuator

Temperature controller- and limiters

OPTISWITCH 4000/5000. Vibration level switches for liquids

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

V5422L / V5422E ACTUATED BUTTERFLY VALVES. FEATURES With factory-mounted electric actuator. SPECIFICATIONS Valves

Automatic Swing Door Operator DFA 127 IN (Inverse) Operating instructions E

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

UP Series Miniature Pilot Lights

Digital ph transmitter

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

- Quicktemp TP62/TW39...T500 -

WATERFLUX 3070 Quick Start

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

ECONOMISER SERIES E2T USER MANUAL

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH

better measurement Simply a question of

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

Mounting & Maintenance Instructions OMT1 & OMT2 Motors

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

PROCAP Capacitance Level Sensors

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

7 Lighting Technology

Transcription:

list of contents page introduction G1 function G1 technical data G2 - G3 electrical connection G4 signal describtion G5 parameter adjustment G6 - G7 commissioning, mounting, safety items G8 error codes G9 maintenance, service interval G10 rope change G11 tape change G12 pricelist P0 - P5 Subject to technical change and price change. All dimesions in mm. Of course there are other unit variations than specified possible. Please speak with our consulting technicians. All units of this pricelist are -certificated. page G0 G12

UWT-Lot introduction - function introduction The UWT-LOT SLS 3000 is an electro-mechanic level measuring instrument for the coninuous measuring of level heights or level volumes in hoppers, silos or tanks. It is used for monitoring the level in applications like - powders - small grain bulk goods - coarse grain bulk goods Features - appropriate for nearly all kinds of bulk goods - absolute insensitive to: - dielectricity and conductivity of the bulk good - dust in the silo - changes in moisture of the bulk good - products, that incline to stick - no mechanical forces on the silo roof, the sensor touches the bulk good only at the surface - very simple installation and commissioning - high tech measurement, easy to understand - very accurate measurement - output 0/4-20mA - range of measurement rope version 30m (on request up to 70m possible) tape version 23m, over-all-heigh of the silo 25m - approval for use in hazardous areas zone 10 (dust-explosion of burnable dusts) - micro processor controlled measurement with intelligent supervision - internal tape cleaner for extreme difficult products (tape version) - different s, suitable to every application - robust diecast housing with protection class IP65 UWT - LOT level measurement systems have stood the test in several applications over a long period of years such as - chemical industry -foodstuff industry - building material industry - plastic industry function The UWT - LOT SLS 3000 is mounted on the top of the silo. A sensor weight is moving down into the silo. The is mounted at the end of a measuring rope-/tape, which is wrapped on a motor driven rope roller. Upon impact on the bulk good, the returns and is drawn back to its upper stop position. The unit is devided into two independent chambers (rope chamber and electronic chamber), which are sealed to each other. Only the rope chamber is in contact to the inside of the silo during the measurement. If the is in the upper stop position, it seales the opening between the unit and the silo. Pulses are generated during downward movement and the number of pulses can be processed directly in a PLC (programable logic controller) or a counter (see chapter transmit /display /evaluation ). 0/4-20mA output: The pulses are internal converted into an analoge current signal. The current signal can be adjusted specifically. So it is possible to get a volume-specific signal, fitting to the geometry of the silo. The current signal is renewed, when the touches the bulk good. The measurement starts with an external start signal (remote-control) with an external make contact or an external 24V DC signal To start automaticly at a predetermined period, an internal timer is standard. The measurement is controlled by a microprocessor. A comparison between the distance the weight moves downwards, and the distance the weight moves upwards, is done. In case of a deviation a signal output is activated. This guarantees, that the is almost in the upper stop position. page G1

technical data technical data dimensions For detailed dimensions of UWT - Lot SLS 3000 see pricelist (page P0 - P3). flange dimensions DN100 PN16 Prevent the to move into the socket! The socket-pipe avoids a collision during the upwards movement between the sensor weight and the socket-edge. Lifetime of the rope is longer due to strong shorttime-loads of the rope are avoided. dimensions silo flange min socket- pipe socket sensor weight folding cover If the is used for measuring of very light and loose bulk material, the risk, that it sinks in the filling material, is given. This can be prevented by using the folding cover which has a large surface. The folding cover can be folded, so that it fits through the mounting socket DN100. pin for The can be equipped with a pin (Ø10mm), which prevents the sensor weight from slipping on the bulk material. page G2 G12

UWT-Lot technical data mechanical data housing enclosure aluminium RAL 5010 gentian blue flange: black IP 65 to EN 60529 measuring interval accuraty of measurement 10cm/pulse (option: 1cm/pulse) : 1 pulse (version with 10cm/pulse) 3 pulses (version with 1cm/pulse) current output: 1% process connection flange DN100 PN16 DIN 2633 aluminium measuring pulse count: 0.13s ON; 0.13.. 0.3s OFF; reset: 0.6s overall weight approx. 17kg connection diagram inside the device, datasheet measuring rope stainless steel, Ø1mm protection class I measuring tape measuring range measuring speed material sensor -weight deviation of vertical mounting pressure connection electrical data mains voltage installed load connection terminal screwed cable gland signal output page G3 stainless steel, 12x0.2mm max. 30m rope version max. 23m tape version (for max. overall heigh of silo 25m) approx. 0.23m/s (average) (upward- and downward movement) 1kg rope version 1.8 kg tape version PVC or PA or 1.4301 folding cover made of canvas max. 2 out of vertical mounting quick couppling including opposite part, for hose diameter 9mm; max. operating pressure: 0.2 bar 230V 50-60Hz 115V 50-60Hz both voltages +10% / -15% max. 40VA with heating (option) additional 80W max. 2.5mm² 3x M25x1,5 (for cable diameter 9-14mm) "" and "" floating relais contact max. 250V AC, 2A, 500VA floating current output 0/4-20mA, ±0.1mA max. load 500Ω heating (optional) signal output (option) operating conditions silo pressure temperature in silo ambient temperature rope-/tape operating time approvals DMT/BVS (option) CE thermostat controlled 230V, 80W; for temperatures downto -35 C or in case of condensation of water inside the housing "upper stop position" / "malfunction" floating relais contact max. 250V AC, 2A, 500VA max. 0.3bar lower temperature: 0 C without heating -35 C with heating -20 C for zone 10/11 with heating upper temperatur: +80 C +220 C (option) lower temperature: 0 C without heating -35 C with heating -20 C for zone 10/11 with heating upper temperatur: +60 C For temperature below 0 C and in case of condensation of water inside the housing it is strongly recommended to use the heating. see page G10 zone10: zone 11: inside the container outside the container EMC EN 50081-1 EN 50082-2 electr. security EN 61010-1

electrical connection electrical connection digital malfunction (opens in case of malfunction) upper stop position (closes, if the sensor weight is at the top) internal connection heating mains voltage alternative current output 0/4-20mA floating activ start of measurement and measurement interruption in case of filling internal connection motor max 250V 2A 500VA max 250V 2A 500VA max 6A max 500Ω connection factoryprovided timing of start 230V 50-60Hz start contact pulse 0,7..5sec alternative start +24V pulse 0,7..5sec measurement inter-ruption in case of filling (e.g. contact at the filing coupling) remove factory-provided connection at terminal 24 and 26 output version 1cm pulse electr. connection version zone 10 For application in areas zone 10, the pertinent rules and regulations (VDE 0165) must be observed. electronic switch relais contact ext. fuse max. 1A timing of start external terminal PE max 40V 0,3A DC or AC page G4 G12

UWT-Lot electrical connection terminal connections The following supply lines are required: mains supply: start of measurement: measurement interruption in case of filling 3 x 1.5qmm ( 2.5qmm max) for N, L and PE provide preceding fuse (max. 6A) 2 x 1.5qmm (2.5qmm max.) 2 x 1.5qmm (2.5qmm max.) evaluation current signal 0/4-20mA relais output 'upper stop position' and 'malfunction' (optional) 2x 1.5mm² (max. 2.5mm²) max. 2.5mm² evaluation counting and : start measuring measurement interruption in case of filling 3 x 1.5qmm (2.5qmm max.) signal describtion terminal 24 and 25 via floating make contact. or terminal 25 and 27 via 24 V DC voltage (current consumption approx. 5mA, observe the polarity) duration of starting signal: 0.7 to 5s terminal 24 and 26 via floating opening contact. In case of opening the terminals 24 and 26, the moves upwards immediatly. Connect here the contact ot the filling coupling of the silo. This prevents the to be buried during the filling process. terminal 5 and 6 The communicates the measured value to the evalu-ation device that is connected. During the downward movement of the, this pulse will be generated every 10cm (option 1cm). terminal 6 and 7 After start of measurement, a will be given for about 0.6s. It resets the connected evaluationdevice (counter/ PLC,...). current signal output upper stop position (option) malfunction (option) terminal 22 (+) and 23 (-) The current signal is a measure for the level (specific adjustable). The current signal is renewed, when the touches the bulk good. It is always actuated. terminal 17 and 18 This signal allows the user to determine whether the measure-ment has come to its end. In this case the is in its upper stop position, terminals 17 and 18 are linked. terminal 15 and 16 In case of a recognized failure (or missing mains voltage) the contact will be opened. Describtion of the error reports see page G9. By evaluation of the signal 'malfunction' a that might have been torn off can be prevented from getting into the unloader of the silo. When the signal 'malfunction' is given, the device must always be checked at the spot. page G5

parameter adjustment parameter adjustment button jumps to the next adjustment item operation / malfunction upper stop position DISPLAY RUN button - jumps to measurement display during parameter adjustment - starts measurement - cancels an error code at the display LED s (not activated in case of malfunction) buttons RUN + - + button increases the value to be adjusted - button decreases the value to be adjusted air distance A cone height C measurement value: 0,00m 1> max. move distance M: 0..30m (1m)* 0..23m** 2> silo height S: 0..30m (0m)* 0..25m** 3> air distance A: 0..30m (0m)* 0..25m** 4> cone height C: 0..30m (0m)* 0..25m** 100% RUN max. move distance M silo height S 0% measurement starts; display shows actual move distance *factory-provided measure/ mm version ropetape PVC 330 650 PVC zone10 700 700 PA 370 710 PA zone10 700 700 folding cover 400 740 folding cover zone10 730 730 stainless steel 250 450 spiderstainless steel 280 460 Take care, that the can move down at least 20cm. **values at tape version The max. move distance M prevents the downward movement of the sensor weight in case of empty silo. note: If the maximum move distance M is adjusted smaller that the silo height S, the measure value is always more than 0%. In case of use of the digital pulse output (terminal 5/6/7, see page G4) the parameters silo heigh S, air distance A and cone heigh C have no influence on the measuring value. Adjustment of the conical height C: C =0 current signal output refer to the material level C>0 current signal output refer to the material volume store changes? yes / no* page G6 G12

UWT-Lot parameter adjustment advanced parameter adjustment (only necessary in case of need) Following parameters can be adjusted in case of need. 100% adjustment current output at level 0% 100% measurement value: 0,00m RUN push "+" and "-" button together 1sec measurement starts; display shows actual move distance 0% 4-20 ma 4mA 20mA 0-20 ma 0mA 20mA 20-4 ma 20mA 4mA 20-0 ma 20mA 0mA A> software version B> current output C> current at error 0mA* 4mA 20mA remain D> timer 0.1h..99.9h off* F> manual control 4-20 ma* 0-20 ma 20-4 ma 20-0 ma E> running mode normal* short upwards downwards In case of malfunction the current jumps to the adjusted value. timer Automatic start of measurement with timer function. Timing intervall between two measurements can be adjusted. The timer will be started: - if the is in the upper stop position after a measurement. - after external measurement start at terminal 24/25/27 - after linking of the terminals 24/26 (measurement interrupt in case of filling) Position "off" causes no automatic measurement start. To get automatic measurement starts at a predetermined time of day, an external start unit at the terminals 24/25/27 is necessary. To avoid needless wear, the unit should not be started more than necessary. running mode adjustment "normal" The moves back to the upper stop position after every measurement. adjustment "short" (only possible in case of use of the 0/4-20mA output) The stops, after it has touched the material, one meter over the material level. This reduces the wear and the measurement time. Every 20 measurements the moves back to the upper stop position to adjust the measurement value. Then it moves back to the position it was before. store changes? *factory-provided yes / no* ATTENTION at runnig mode "short" To avoid the burying of the during the filling of the silo, the function "measurement interrupt in case of filling" (terminals 24/26, see page G4) must be used. Before the filling starts, the must be in the upper stop position. manual control push "+" button: The motor moves the upwards as long as the button is pushed. push "-" button: The motor moves the downnwards as long as the button is pushed. Caution: Avoid, that the reaches the outlet position of the silo. page G7

safety items - mounting commissioning safety items Warning: In the case of inexpert handling or handling malpractice, the safety of the device cannot be guaranteed. 1. Connect the unit with mains voltage, evaluation units and starting units (see page G4). 2. Compare mains voltage and frequency with the specifications on the type plate. 3. Connect the unit to the mains voltage. The must now move in the position upper stop position (if not already happened). 4. Adjust the parameters (see page G6 and G7). 5. The unit is now ready for work. Measurements can be started. All parts with dangerous electric tension are protected, after the lid has been opened. Switch off mains voltage, before any parts of the unit are removed. Mains voltage circuit must be protected with a fuse (max. 6A). In the case of a defect, the distribution voltage must auto-matically be cut off by a FI protective switch, so as to pro-tect the user of the device from indirect contact with dangerous electric tensions. For terminal connection of the device, the local regulations or VDE 0100 (Regulations of German electrotechnical Engineers) must be observed. For application in areas zone 10, the pertinent rules and regulations (VDE 0165) must be observed. In the case of inexpert handling or handling malpractice, the electric safety of the device cannot be guaranteed. Isolating mains voltage to signal output: 3kV~ mounting The unit is mounted vertically with the flange on the silo. Avoid the to graze the socket (this causes wear of the rope). The mounting position must be choosen carefully: Provide protection for relay contacts to protect the device against spikes with inductive loads. There must be at least 20cm space for the to move down in case of a full silo. Pay attention to the lower cutting edge of the in case of upper stop position (measure see page G7). - cornices that might fall down may damage the sensor weight or the rope. Observe proper distance from silo wall - filling of the silo might cover the with material (prevent measuring during filling or observe proper distance to infeed) socket - upward and downward movement of the must not be obstructed, even if the weight oscillates; observe proper distance to stanchions and built-in fittings The electrical connections are made in accorcance with the connection diagram. Make sure, that the cable in the screwed cable gland is seated tightly without fail. cornices distance distance Close both lids of the housing, to prevent entrance of water into the housing. When the unit is used in the open, we recommend to use the weatherprotection-cover. It protects the unit against moisture, heat and cold. In case of temperatures lower than 0 C or expecting condense water inside the housing, a heating (option) is strongly recommended. page G8 G12

UWT-Lot error codes Switch off the mains voltage and take care, that it is not switched on again, before you start any repair at the device. error code possible reason behaviour of the device remedy error code 2 Internal pulse sensors are not identified from the software. The motor stops. When the pulse sensors can be identified again, the moves to the upper stop position. Connect the internal plug for the pulse sensors. error code 3 Rope/ tape break. Motor blocked or defect. The motor stops. This code is displayed in the following case: error code 4 happens; the motor tries to move the senor weight upwards; after 4 minutes the upper stop position is not reached; Repair the rope-/tape break (see page G11/G12). Look for the reason of motor blocking. error code 4 No pulses come from the return pulley. Return pulley moves too heavy. The motor moves the upwards, until it reaches the upper stop position. Repair the heavy movement of the return pulley. error code 6 Sensor weight buried or jammed. The motor moves 2 seconds upwards, then it waits for 10 seconds. After that the motor moves shortly downwards and then upwards again. If the sensor weight is still jammed, this cycle repeats 5 times. After that the delay time will be increased to one hour. Release the. Take care, that the might move without obstacle. error code 7 Mains voltage too low. Take care for the right mains voltage. error code 8 Sensor weight blocked in upper stop position or move distance <20cm. The unit tries 5 times to start. If the is not able to release, the error code is set. Release. Increase the min. move distance to >20cm. error code 9 service interval see chaper service interval page G10 By pushing the "RUN" button, an error code shown on the display can be canceled. Control of the measurement return pulley operation / malfunction upper stop position LED s (not activated in case of malfunction) internal plug for pulse sensors fuse F1 2,5A slow to blow DISPLAY RESET Jumper The device compares the distance of downwards movement of the (until it reaches the surface of the bulk good) with the distance of upwards movement, until it reaches the upper stop position. In case, that the values are different, this is an indication for a buried or jammed sensor weight. Furthermore, the pulses generated from the return pulley during the measurement, are supervised. In case of missing or too irregular pulses, this indicates that the return pulley moves too heavy, or that the motor is blocked. "upper stop position" sensor weight page G9

maintenance/service interval maintenance The UWT- LOT SLS 3000 measuring device features a high degree of functional reliability and it requires virtually no maintenance during normal operation. Yet the regular observance is recommended: Open the lid to the rope-/tape chamber. rope-/tape chamber rope-/tape roller Remove any excess material in the rope-/tape chamber. Visual inspection of the rope-/tape as to rubbed-off parts or damage. Close the lid to the rope-/tape chamber tight. If the rope-/tape is rubbed-off or damaged, it must be changed (perhabs shortened). Available spare parts are: - single rope - rope-/tape roller complete (with 30m rope or 23m tape) - mounting set for - s rope-/tape service interval (error code 9) Error code 9 is created automaticly after following number of measurements: rope version: 30 000 tape version: 40 000 To guarantee furthermore a faultless work, it is strongly recommended to change the rope/tape (see page G11 or G12). Rope-/tape operating time Number of measurements rope version approx. 60 000 tape version approx. 90 000 These values refer to longtime tests without influence of material. The meets an incline surface, so that an oscillating movement of the is caused. Due to these values, following operating times are caused: Canceling the error message by pushing the RUN -button. The next message will appear after further 30 000 (4o 000) measurements, operating time / years 50 45 40 35 30 25 20 15 10 5 1 5 10 15 20 25 rope version tape version 50 45 40 35 30 25 20 15 10 5 1 5 10 15 20 25 number of measurements /day page G10 G12

UWT-Lot rope change NOTE: Only the manufactorer is allowed to repair units with approval BVS / DMT dust Ex zone 10/11 rope change Switch off power supply, make sure that power cannot be accidentally restored/switched back on. rope chamber Screw the device off the mounting socket. Open the lid to the rope chamber. rope roller Remove the rope roller (4 screws). Wind up a new rope or mount a new cable roller (observe the direction of winding), leave about 1.5 m of rope unwound. Mount the in accordance to the drawing. Lead into the socket, mount the device at the flange again. Check the leading of the rope inside the rope chamber. Close the lid to the rope chamber tight. Switch on power supply. The moves automaticly in the "upper stop position". rope The device is now ready for work. Measurements can be started. A new software adjustment is not necessary. rope shrinking hose lighter or hot air tubing knot the rope tight page G11

tape change tape change Take care by working with the tape. Danger of injury caused by sharp edges. Do not bend the tape. Switch off power supply, make sure that power cannot be accidentally restored/ switched back on. NOTE: Only the manufactorer is allowed to repair units with approval BVS / DMT dust Ex zone 10/11 tape chamber tape roller tape leading bolts Screw the device off the mounting socket. Open the lid to the tape chamber. Remove the tape roller (4 screws). Mount a new tape roller (observe the direction of winding), leave about 1.5 m of tape unwound. Take care, that the tape moves inside the tape leading bolts. Remove tape cleaner (including sealing), to lead the tape through the socket pipe. Mount the in accordance to the drawing. Lead into the socket, mount the device at the flange again. Check the leading of the tape inside the tape chamber. Close the lid to the tape chamber tight. Switch on power supply. The sensor weight moves automaticly in the "upper stop position". The device is now ready for work. Measurements can be started. A new software adjustment is not necessary. tape socket pipe tape cleaner with spring; fixed with 4 screws sealing rubber nozzle cone part srcew, nut spring Take care, that the tape cleaner can move up against the spring and down again. 3 tape fixing parts 2 screws page G12