D509E. Manual Motor - Starters

Similar documents
Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Micro Contactor MA Series

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Technical Information

MS25, MST25, MS20, MST20

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Technical data for manual motor starters Type MS325

Mini DC - Isolators for Photovoltaic

DC-Switch Disconnectors for Photovoltaic acc. to IEC

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Contactors Motor-Starters D677E121

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Contactors RAST 5 D778E131

Modular Contactors and Switches D681E121

AF40... AF96 3-pole contactors Technical data

Control switch/load disconnect switch Series 8008

max pole for t=15 ms

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Protection components

Motor Circuit Breakers C3

Industrial Contactors CTX 3 3P 185A - 800A

3VU13, 3VU16 Circuit-Breakers

MS General Information Extended Product Type: MS

3 - Protection components Motor circuit-breakers

General Informations 2 Technical data 3 Basic designs 4-8

Devices for switching and control

cor Long Run Experience

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Manual Motor Starters. Meta-MEC

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Protection Equipment

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Motor protective circuit breakers

General Catalogue. Quality made in D946E173

Capacitor Switching Contactors Type K3...-A, K3...-K

Electronic circuit breaker EBU10-T

FMotor Circuit Controllers

Solar Installer Range. Bright solutions

Modular contactor for installation into distribution boards

SD Series Non-Fused Load Switches

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

CI-TI Contactors and motor starters Types CI 61 - CI 98

Index. Page. General 4 Approvals 5 Technical Information 9 Mounting Information 10

KT4 Manual Motor Starter

Load and Motor Switches, Load-Break Switches Series 8549

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Ideal for use as a manual starter

Motor protective circuit breakers

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

MS25, MST25, MS20, MST20

4 - Miniature controls

Cylindrical fuse-link

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Manual motor starter MS116

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Motor Circuit Breakers C4

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Thermal overload relay TF65 and TF96

Manual Motor Starter MS 116. Technical Catalogue

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

CI-TI Contactors and Motor Starters Type CI 6-50

Protection Equipment. 5/2 Introduction

Miniature Circuit Breaker

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

US CATALOG. Miniature circuit breakers

Load disconnect switch Series 8146/5-V11

Electronic overload relays EF205 and EF370

Selection Guide Motor Control Device Solutions

Electronic overload relay EF65, EF96 and EF146

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

Components for EEx e Panels

Vistop TM isolating switches 63 to 160A

TX³ RCCBs 2P up to 100 A

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side


Ktec Contactors and thermal overloads

DX³ RCCBs - ID 4P up to 100 A

Motorized switch-disconnectors OTM 40 to 125 Amperes

and other modular devices for low voltage installation

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Short form catalogue Motor protection and control Manual motor starters

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Load and Motor Switches, Load-Break Switches Series 8544

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Thermal overload relay TF140DU and TF140DU-V1000

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Transcription:

D509E Manual Motor - Starters

Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors 183 Enclosures 183 Leistung, kw C mv AC3......... Technical Data 184 Dimensions 185 Tripping Charactaristic 185 181

Manual Motor Starters Thermal Ratings Magnetic Type Pack Weight Overload Release AC3 at short circuit trip Setting Range 400V 690V A kw kw A pcs. kg/pc. 0,1-0,16 0,02 0,06 1,92 MU25A-0,16 1 0,25 0,16-0,25 0,06 0,12 3,0 MU25A-0,25 1 0,25 0,25-0,4 0,09 0,18 4,8 MU25A-0,4 1 0,25 0,4-0,63 0,12 0,25 7,6 MU25A-0,63 1 0,25 0,63-1 0,25 0,55 12,0 MU25A-1 1 0,25 1-1,6 0,55 1,1 19,2 MU25A-1,6 1 0,25 1,6-2,5 0,75 1,5 30 MU25A-2,5 1 0,25 2,5-4 1,5 3 48 MU25A-4 1 0,25 4-6,3 2,5 4 75,6 MU25A-6,3 1 0,25 6,3-10 4 7,5 120 MU25A-10 1 0,25 10-16 7,5 11 192 MU25A-16 1 0,25 16-20 9 12 240 MU25A-20 1 0,25 20-25 12,5 22 300 MU25A-25 1 0,25 25-32 15 384 MU25A-32 1 0,25 Auxiliary Contact Blocks, for side mounting, max. 2 pieces 5 230V 400V 500V NO NC EM 1) A A A pcs. kg/pc. 1 - - 3,5 2 6 MU25A-PS10 10 0,03-1 - 3,5 2 6 MU25A-PS01 10 0,03 2 - - 3,5 2 6 MU25A-PS20 10 0,03 1 1-3,5 2 6 MU25A-PS11 10 0,03-2 - 3,5 2 6 MU25A-PS02 10 0,03-1 1 3,5 2 6 MU25A-PV11 10 0,03 - - 2 3,5 2 6 MU25A-PV20 10 0,03 Transverse Auxiliary Contact Block, max. 1 piece 5 230V 230V NO NC EM 1) A A pcs. kg/pc. 1 1-1 5 MU25A-PA11 10 0,02 Auxiliary Contact Blocks for mounting under the cover, max. 1 piece 5 230V 400V 500V NO NC EM 1) A A A pcs. kg/pc. 1 1-3,5 2 6 MU25A-PE11 10 0,02 Trip Alarm Auxiliary Switch for mounting under the cover, max. 1 piece 5 230V 400V 500V NO NC EM 1) A A A pcs. kg/pc. 1 - - 3,5 2 6 MU25A-PM10 10 0,02-1 - 3,5 2 6 MU25A-PM01 10 0,02 1) early make 182

Shunt Release for mounting under the cover Rated Control Voltage Power Consumption Type Pack Weight and Frequency V VA W pcs. kg/pc. 24V 50/60Hz 2,7 1,8 MU25A-A24 10 0,06 110V 50Hz, 110-120V 60Hz 2,7 1,8 MU25A-A110 10 0,06 220-230V 50Hz, 240V 60Hz 2,7 1,8 MU25A-A230 10 0,06 380-415V 50Hz, 440V 60Hz 2,7 1,8 MU25A-A400 10 0,06 Under-voltage Release for mounting under the cover Rated Control Voltage Power Consumption Type Pack Weight and Frequency V VA W pcs. kg/pc. 24V 50/60Hz 2,7 1,8 MU25A-U24 10 0,06 110V 50Hz, 110-120V 60Hz 2,7 1,8 MU25A-U110 10 0,06 220-230V 50Hz, 240V 60Hz 2,7 1,8 MU25A-U230 10 0,06 380-415V 50Hz, 440V 60Hz 2,7 1,8 MU25A-U400 10 0,06 Accessories Description Specification Type Pack Weight pcs. kg/pc. Busbar Connector Fully Isolated, U i 690V, I u 63A Busbar For 2 units 3-pole, 99mm long MU25A-D99 10 0,036 Busbar For 3 units 3-pole, 154mm long MU25A-D154 10 0,060 Busbar For 4 units 3-pole, 208mm long MU25A-D208 10 0,084 Busbar For 5 units 3-pole, 262mm long MU25A-D262 10 0,107 Supply Block 3-pole for use with busbar connector MU25A-DB 10 0,034 Spacing piece ½TE for ambient temperature >40 C P730 10 0,013 Enclosures Moulded Enclosure Protection to IP55 MU25A-O55 1 0,24 Moulded Front Plate Protection to IP55 MU25A-C55 1 0,16 Locking Bracket Suitable for 3 padlocks in MU25A-Z 1 0,10 "OFF"-position, stirrup diameter of the padlock max. 8 mm Stop Button Mushroom head MU25A-NAT 1 0,04 Emergency Stop Button latch, release by turning MU25A-NAV 1 0,04 Emergency Stop Button latch, release by key MU25A-NAS 1 0,04 Neutral Conductor Block for mounting in enclosure MU25A-NL 10 0,01 and front plate Wiring cross section 0,75-2,5mm² Moulded Enclosure Protection to IP54 MU25A-GC1 1 0,40 for 5-pole CEE-plug with phase changing 183

Manual Motor Starters Data according to IEC 947, IEC 204, EN 60947, EN 60204, VDE 0660, VDE 0113 Type MU25A Main Contacts Rated insulation voltage U i V~ 1) 690 Rated operational current I e (=I th ) open, at 50 C A 25 Mechanical life S x 10 6 0,1 Contact life at I e /AC3 S x 10 6 0,1 Tripping class according to IEC 60947-4-1 10A Rated ultimate short-circuit breaking capacity I cu 220-240V AC 380-415V AC 500V AC 660-690V AC Values for open unit, when incoming supply on upper terminals Setting range to 1A ka 100 100 100 100 1-1,6A ka 100 100 100 100 1,6-2,5A ka 100 100 3 2,5 2,5-4A ka 100 100 3 2,5 4-6,3A ka 100 100 3 2,5 6,3-10A ka 100 6/50 2) 3 2,5 10-16A ka 10/100 2) 6/50 2) 2,5 2 16-20A ka 10/100 2) 6/50 2) 2,5 2 20-25A ka 10/100 2) 6/50 2) 2,5 2 25-32A ka 10/100 2) 6/50 2) 2,5 2 Short circuit protection 220-240V AC 380-415V AC 500V AC 660-690V AC Setting range to 1A A - - - - 1-1,6A A - - - - 1,6-2,5A A - - 25 20 Fuse gl(gg) only necessary if the short circuit current could be greater than the rated ultimate short-circuit breaking capacity 2,5-4A A - - 35 25 4-6,3A A - - 50 35 6,3-10A A - 80 50 35 10-16A A 80 80 63 35 16-20A A 80 80 63 50 20-25A A 80 80 63 50 25-32A A 80 80 63 50 Maximum ambient temperature Operation open C -25 to +55 enclosed C -25 to +40 Temperature compensation C -20 to +55 Power loss at rated current, warm condition W 6-8 Auxiliary Contacts Rated insulation voltage U i V~ 500 Thermal rated current I th Ambient temperature max. 50 C A 6 Utilization category 5 Rated operational current I e 220-240V A 3,5 380-415V A 2 500V A 1 Short circuit protection max. fuse size gl (gg) A 6 Cable cross-section Main connector solid or stranded mm² 0,75-4 flexible mm² 0,75-2,5 flexible with multicore cable end mm² 0,75-2,5 Cables per clamp 2 Auxiliary connector solid or stranded mm² 0,75-2,5 flexible mm² 0,75-1,5 flexible with multicore cable end mm² 0,75-1,5 Cables per clamp 2 Resistance to shock according to IEC 68-2-27 Operation g / ms 4 / 11 Solidity g / ms 30 / 18 1) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 6kV. 2) with current limiter MBS25-ID50 up to 415V AC 184

Manual Motor Starters Dimensions Manual Motor Starter MU25A Moulded Enclosure MU25A-O55 Moulded Front Plate MU25A-C55 Moulded Enclosure for 5-pole CEE-plug MU25A-GC1 Temperature Compensation In case of higher ambient temperature use the following formula: (Ambient temperature - 20) x 0,3 = correction factor in % of the full load motor current Mounting with clamps with screws Example: Ambient temperature 60 C, full load motor current 5A (60-20) x 0,3 = 12% Setting value: 5A + 12% = 5,6A Tripping Charactaristic 0,16-16A 16-32A seconds minutes 2-pole 3-pole electromagnetic short circuit relais at higher value lower value seconds minutes 2-pole 3-pole x rated current x rated current 185

System MU25A Approvals Country USA, Canada Switzerland Europe CB/CCA- UL SEV Certificates Type MU25A o o / - o In standard version approved / No testing required CE x In test - Not provided for test till now 186