HP Server Mount Kit AB292A for 19 in. 2-Post Rack Installation Instructions Manufacturing Part Number: AB April 2004

Similar documents
HP BladeSystem c7000 Carrier-Grade Options Installation Guide

HP Adjustable Depth Fixed Rail Kit Installation

1U 4 Bay Chassis Rack Mounting Instructions

CONSOLE MANAGEMENT CONTROLLER

HP Modular Cooling System 200/100 Options Installation Guide

QuickSpecs. HP 480/277 Volt Solutions. Overview

Agilent N5470A Series Oscilloscope Rack Mount Kit

Battery Pack Options - Choose up to two Battery Packs per UPS (must be the same)

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

QuickSpecs. HP Basic Power Distribution Units. Overview

Installing the CO 2 Cryogenic Oven Cooling Kit

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

VW Surface-Mount Strain Gauge

Made in the U.S.A.! SAFETY

Installation Guide Thermal Conductivity Detector Accessory 19232E

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Installation Instructions. Bosch RSV Governor Shutdown Kit with 1751 & 1751ES Solenoids. Manual (Replaces SE-3042 Rev C)

Installation manual. Pole-mount Deployment System

Installing the Dionex ICS-1100/1600/2100 Auxiliary Valve

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

1000 Park Drive Lawrence, PA Fax

APOLLO Model # - F-12013, F-22013, D-50115, D-50215, D-50415, D-50615, D-50815, D Apollo Series- Instruction Manual V.3

Installation Manual for VMAC Throttle Commander

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts V2. Overview. HP Managed and Unmanaged V2 Notebook Charging Carts

Installation Guide NPD/ECD Chemical Filters Accessory 19199N

Assembly Instructions Signature Choral Riser 3-Step Model

Dionex AS-DV Autosampler Preventive Maintenance Procedure

2-Post Rack Mount Kit Installation Instructions

JK Spring Spacers. Important Notes: Tools needed: This installation guide Basic mechanics tool set.

COMPETITION ENGINEERING. 80 Carter Drive P.O. Box 1470 Guilford, CT Phone: (203) Fax: (203)

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Toro Sprayer Calibration Tool

Description AX5806. List of permissible motors. Version: Date:

MODEL PS-4 DIGITAL PORTION SCALE

JK Front Bumpstop Extensions

Agilent N2763A Rack Mount Kit for 4000 X-Series Oscilloscopes

INSTALLATION INSTRUCTIONS P/N S: C2091 & C2093 SLIDE-A-LINK

Installing the Boom Mount ET 350 Monitor (Model ET 350R)

TBX-1328 High-Accuracy Isothermal Terminal Block

Heavy Duty Engine Cranes

ISO 91:2017 Consulting Paper. Guidance for QuantityWare BCP Implementations

Support matrix. Page 2

QuickSpecs. HP Parallel 3 Phase Uninterruptible Power Systems Overview

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

M2004. Document ID: 3HAC Revision: - Copyright 2010 ABB. All rights reserved.

OBDII to J1587/J1708 Converter Installation and Troubleshooting Guide

Operating Instructions. Hydraulic Jacks JH G-plus Series

Universal Deck & Rail Cart

Installation Guide. Purged Packed Inlet, Electronic Pneumatics Control on 6890 GC Accessory G1551A

COMPETITION ENGINEERING. 80 Carter Drive P.O. Box 1470 Guilford, CT Phone: (203) Fax: (203)

[PDF] LASERJET 4250 USERS MANUAL DOWNLOAD

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

Intel Server Chassis and Platform Bracket Kit Installation Guide

JK 2-Door 2 Stretch Kit Instructions

JK CARGO STORAGE RACK

Installation Instructions Studio Makeup Station

2006 Dynojet Research, Inc. All Rights Reserved. Spring Applied Air Release (SAAR) Brake Assembly Installation

Getting Started With Your System

Fast Standard Control Installation Manual FT4

Made in the U.S.A.! SAFETY

JK Steering Stabilizer Relocation Kit (for Stock Tie Rod)

Installing an Auxiliary Pressure Control Module

ID150, ID200 and ID250 Service Parts

SmartRack 4-Post Heavy-Duty Open Frame Racks

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

JK High Steer Knuckles

Installation Instructions 2019 Chevy and GMC 1500 Rear Bumper Product Number: E4050, E4051 Application: Chevy and GMC 1500 Trucks

baseplate Chevrolet Equinox

JK Rear Performance Big Rotor Kit

TJ/LJ Upper Control Arms

Engine Crane Owner s Manual

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

1/4" Square Single-Turn Cermet Sealed Trimmer

ZIP LIGHT LED LUMINAIRE

TeraFlex TJ Single Rate S/T Sway Bar

Mounting an EX 8200 series Switch on a Rack or Cabinet Without Using a Mechanical Lift

Agilent G3510A/G3511A Multimode Inlet

TJ/LJ/XJ/ZJ Lower Control Arms

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

System 3 ZB1PS Device Chassis. Operator s Manual

JK HD Skid Plate for Rear Falcon Shocks

WARNING Read these materials prior to assembling and using the trampoline and Trampoline Enclosure

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

EASY SPRING WAND INSTALLATION MANUAL. April 2018

FuelsManager and Radar Tank Gauging for Overfill Prevention

JK 2 and 4 Door 2.5" Lift Kit Installation Instruction

Heavy Duty Engine Cranes

Nota Conductor s Chair

Doing Our Best to Provide You the Best. Instructions for 1997 & 1998 Models start on page 5. Jeep Cherokee. 8/16 TP20010,Rev.10

JK HD Skid Plate for Rear Falcon Shocks

ARION: 19 EIA-310E Standard Enclosure

OnBoard Drum Major Podium

TeraFlex TJ Dual Rate S/T Sway Bar

July 15, 2016 NOTICE INVITING BIDS NOTICE TO SUPPLIERS FOR FURNISHING MOTOR VEHICLES

JK License Place Delete Badge

Installing the Switch Chassis

Transcription:

HP Server Mount Kit AB292A for 19 in. 2-Post Rack Installation Instructions Manufacturing Part Number: AB292-96001 April 2004 U.S.A. Copyright 2004 Hewlett-Packard Development Company, L.P..

Legal Notices Copyright Notices. Copyright 2004 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Reproduction, adaptation, or translation of this document without prior written permission is prohibited, except as allowed under the copyright laws. Printed in the U.S.A. Related Documents. The latest versions of server documents, and any updates to these documents are posted under the appropriate server at http://docs.hp.com. For online access to technical support information, self-solve tools, online assistance, community forums of IT experts, broad multi vendor knowledge base, and monitoring and diagnostic tools, go to http://www.hp.com/support. 2

1 HP Server Mount Kit for 19 in. 2-Post Rack Installation Instructions Introduction This manual provides instructions for installation of the hp Integrity cx2600 server chassis in a 19 in. 2-column rack, with column widths of 3 to 9 inches. Cabinet Safety Precautions WARNING Ensure that the rack is level and stable before working on the rack. Be sure the leveling jacks (feet) extend to the floor and that the full weight of the rack rests firmly on the floor. WARNING Ensure that the rack has anti-tip measures in place. Such measures may include floor-bolting, anti-tip feet, ballast, or a combination of these measures as specified by the rack manufacturer and applicable codes. WARNING Be sure that adequate personnel are on hand to support the product(s) during the installation process. Use of the appropriate lifting device is recommended as an installation aid. WARNING Always load the rack from the bottom up. Load the heaviest items in the rack first. This makes the rack bottom-heavy and helps prevent the rack from becoming unstable. WARNING Do not overload the branch circuit that provides power to the rack. The total rack load should not exceed 80% of the branch circuit rating. Mounting Kit Contents This manual provides installation instructions for server mount kit AB292A. This kit is intended for use with the hp Integrity cx2600 server, and includes the following: Chassis Tray (Base) Two Rack Brackets Cable Management Strain Relief Bar Mounting Hardware (screws, washers, and nuts) Chapter 1 3

Mounting Options Mounting Options The server chassis can be mounted with the chassis front at the rack columns, or with the chassis centered between the rack columns. The front-mount option facilitates alignment of the chassis front panel with those of other items in the rack. (The tray provides adequate support to prevent unbalancing the rack or stressing the columns.) The center-mount option provides improved weight distribution for those installations where columns are already stressed. Figure 1-1 Mounting Options 2pmntopt Front Mount Center Mount The mounting holes in the chassis rack ears, together with the holes in the tray (base) and rack columns (approximately 1/4-inch centers) allow adjustment of the server mounting position, up to the practical limits of weight distribution. The server is supported in the tray (base) and held in position by eight screws (provided). 4 Chapter 1

Mounting the Server with Chassis Front Aligned with Rack Posts Mounting the Server with Chassis Front Aligned with Rack Posts Figure 1-2 Front Mounting in a 2-Column Rack 2pfrtmnt1 Mounting Kit Before mounting your server in a 2-column rack, inspect the mounting kit hardware. Review the installation procedure and determine which screws will be required. (Alternate screws are provided due to the variations in rack column mounting threads.) Verify that all needed parts are available. (A mounting kit parts list is provided at the rear of this manual.) Installation Procedure Front Mount Front-mount a server in a 2-column rack as follows: Step 1. Install the tray (base) to the back of the rack columns, at the desired mounting position. Attach the tray to the rack columns with T25 10-32 or 12-24 panhead screws, lockwashers, and #12 flatwashers. Chapter 1 5

Mounting the Server with Chassis Front Aligned with Rack Posts Figure 1-3Attach Kit Hardware to Rack Columns Front Mount Tray T25 10-32 or 12-24 Screws Nut Clips T25 10-32 Screws Nut Clips Cable Management Bar Bracket 2pfrthrd (View from Rear) Step 2. Install the 10-32 nut clips on the tray (base) where the bracket mounting screws will be installed. Step 3. From the front of the rack, slide the server chassis onto the tray (base), with the chassis rack ears against the rack columns. Attach the rack ears to the columns with T25 10-32 or 12-24 panhead screws, lockwashers, and #12 flatwashers. Figure 1-4Attach Server Rack Ears to Rack Columns Front Mount Bracket T15 Screws T25 10-32 or 12-24 Screws Tray Rack Ear 2pfrtmnt2 (View from Front) Step 4. Loosely attach the chassis brackets to each side of the server chassis with T15 screws and plated flatwashers. Attach the rack brackets to the tray (base) with T25 10-32 screws. Then tighten all screws. Step 5. Attach the cable management strain relief bar to the brackets with T25 10-32 screws. (See Figure 1-3.) 6 Chapter 1

Mounting the Server with Chassis Centered Between Rack Posts Mounting the Server with Chassis Centered Between Rack Posts Figure 1-5 Center Mounting in a 2-Column Rack 2pcntmnt1 Mounting Kit Before mounting your server in a 2-column rack, inspect the mounting kit hardware. Review the installation procedure and determine which screws will be required. (Alternate screws are provided due to the variations in rack column mounting threads.) Verify that all needed parts are available. (A mounting kit parts list is provided at the rear of this manual.) Installation Procedure Center Mount Center-mount a server in a 2-column rack as follows: Step 1. Install the tray (base) to the front of the rack columns, at the desired mounting position. Attach the tray to the rack columns with T25 10-32 or 12-24 panhead screws, lockwashers, and #12 flatwashers. Chapter 1 7

Mounting the Server with Chassis Centered Between Rack Posts Figure 1-6Attach Kit Hardware to Rack Columns Center Mount T25 10-32 or 12-24 Screws Nut Clips Tray T25 10-32 or 12-24 Screws Cable Management Bar 2pcnthrd (View from Rear) Bracket Step 2. Install the 10-32 nut clips on the tray (base) where the chassis rack ear mounting screws will be installed. Step 3. From the front of the rack, slide the server chassis onto the tray (base), with the chassis rack ears against the front of the tray. Attach the rack ears to the tray with T25 10-32 screws, lockwashers, and #12 flatwashers. Figure 1-7Attach Server Rack Ears to Server Tray Center Mount T15 Screws Bracket Rack Ear T15 Screws Base T25 10-32 Screws Rack Ear 2pcntmnt2 (View from Front of Rack) 8 Chapter 1

Mounting the Server with Chassis Centered Between Rack Posts Step 4. Loosely attach the chassis brackets to each side of the server chassis with T15 screws and plated washers. Attach the rack brackets to the rack columns with T25 10-32 or 12-24 panhead screws, lockwashers, and #12 flatwashers. Then tighten all screws. Step 5. Attach the cable management strain relief bar to the brackets with T25 10-32 screws. (See Figure 1-6.) Chapter 1 9

AB292A Rack Mount Kit AB292A Rack Mount Kit The HP Server Mounting Kit, part number AB292A includes the items listed below. Table 1-1 Mounting Kit Parts List Item Quantity HP Part Number MFAB, base, rack 2-column 1 AB292-00001 Bracket, rack 2-column 2 AB292-00002 MFAB, cable management strain relief bar Screw, T15, waferscrew, w/captive lock washer, M4 x 7 mm 7.5 mm Screw, T25, 10-32,* 0.625 L, panhead w/cc washer Screw, slot/phillips, 12-24 x 0.6 L, panhead Washer, flat, 4.3 mm ID, 12 mm OD, 1 mm thick Washer-lock, HLCL #12 0.225 ID, 0.377 OD, SS w/passivated finish 1 AB292-00011 8 A6474-00134 16 2680-0323 8 2940-0503 8 3050-1244 8 2190-0631 Nut clip, 10-32* 4 0590-2997 Washer, flat, #12, 0.25 ID, 0.562 OD, 0.062 thick, steel w/zink plating HP Server Mount Kit AB292A for 19-in. 2-Post Rack Installation Instructions 8 3050-0212 1 AB292-96001 * Due to variations in rack column mounting threads, alternate hardware is provided for installation flexibility. 10 Chapter 1