Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Similar documents
LED Recessed Troffer Retrofit Kit

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

LED Utility Wrap Fixture

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Use and Care Guide. Part # UC SV-D Model # UC SV-d UC SV-d

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

4 WAY WIRELESS REMOTE CONTROL SYSTEM. User Manual

FOR INDOOR/SEASONAL USE ONLY

Compose GYPSUM Mud-In

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Upton LED Chandelier 40in Assembly Instructions

LIGHT & SOUND BATH VANITY LIGHT

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

USE AND CARE GUIDE 4 FT. LED WRAP LIGHT

Use and Care Guide. Item #

30in Phoebe Round Crystal Chandelier Assembly Instructions

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

7.5' LED Silver Glitter with Pinecones One Plug Tree V INSTRUCTION MANUAL

V-D2425 and V-D2440 Digital Clock

Cab Control Operators Manual

Please read and understand all precautions prior to use.

VERSA TOUCH 2 INSTALLATION VERSA TOUCH 2 CONTROL BRACKET INSTALLATION

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

SHINE 3000 POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

Installer Guide smart connect

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Use and Care Guide. Item #

WIRELESS SMART CHARGING PAD OPERATING INSTRUCTIONS PLEASE READ BEFORE OPERATING THIS EQUIPMENT

2800 OPERATING INSTRUCTIONS

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

Use and Care Guide.

OWNER S MANUAL Please read and understand all precautions prior to use.

Operating Instructions

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

USE AND CARE GUIDE 7000 LUMEN TWIN HEAD LED WORKLIGHT WITH TRIPOD

Lumination TM LED Luminaire LUR Series

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

HERCULES ITEM NO UNBREAKABLE HELICOPTER AGES CHANNEL GYRO RC HELICOPTER FEATURES

PerfectTilt RF Motorized Shutter User Manual

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Back-Up Sensor System

LED FLUSHMOUNT CEILING FIXTURES

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

ASSEMBLY & USE INSTRUCTIONS

USE AND CARE GUIDE 2500 LUMEN LED PORTABLE WORKLIGHT

Installation Instructions RF4510-EA

MULTI-FUNCTION JUMP STARTER

HOVERTRAX 2.0 HOVERTRAX DLX 2.0 REPLACEMENT BATTERY PACK KIT

J5242.

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

Auto-Lift Operating System

Universal Retrofit System Installation Instructions Revised:

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

INSTALLATION INSTRUCTIONS

Assembled Parts. Terminal Base. Barn Roof. Air Track with Tabs. 2 Barn Walls. Barn Base. 4 Air Tracks with Connectors. Air Track with Support

Monnit Wireless Range Extender Product Use Guide

SAFETY DATA SHEET Spright Recharge LED Lantern

MOTION-ACTIVATED WALL LANTERN

integra trim ltd. Holiday Home: EASTER/SPRING Try Me Hang Tag - Children s Product I Play or I Sing Goes Here Name of Song TRY ME! Product Name 2 in.

Owner's Manual. For latest instructions please go to

AirVolt - P User s Manual. 3CH Mini Indoor Helicopter w/ Gyro. Ages 14+ and up

LIPSTICK CHARGER POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

Solar Powered Wireless Temperature Station & Sensor

Wireless Key Tracker. Locate Lost Keys instantly

ecolor Cove MX Powercore Premium interior linear LED cove and accent fixture with solid color light

Bounce & Spin ZebraTM

1000-Watt Energy Center

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

Step1: Battery and Speaker Assembly Step 2: Pump and Battery Installation Step 3: Setting Up Your Fountain 6 Troubleshooting and Maintenance


SAVE THESE INSTRUCTIONS

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

SAFETY DATA SHEET Brila Recharge Lantern

V-DW2425A / V-DW2440 and V-DW11025A / V-DW11040A

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

LED 2/3/4ft T8 Tube 120V


LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

DOOR LIMITS A) ENGAGE CHAIN/BELT CONNECTOR TO CARRIAGE CAUTION B) CLOSE TRAVEL LIMIT

CLASSIC II Portable Braking System

Instruction Manual 03

SAVE THESE INSTRUCTIONS

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved.

Product Installation Instruction LED Tube Lamp Retrofit Kits

CAUTION-ELECTRICALLY OPERATED PRODUCT:

INSTALLATION INSTRUCTIONS

BroadBand PowerShield. 20 AHr Battery. User Manual

Installation and Operations Manual

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

Transcription:

support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC: 60 Ft 208VAC: 100 Ft 240VAC: 100 Ft 277VAC: 100 Ft 2700 K, 3000 K, 3500 K i2cove Asymmetrical Installation Instructions Before you begin, read these instructions completely and carefully. If you have any questions regarding the proper use, installation, or safety considerations of this product, please visit our website or contact i2systems Customer Support @ 860.567.0708. DANGER: RISK OF ELECTRICAL SHOCK OR FIRE. DISCONNECT POWER BEFORE INSTALLATION. WARNING: Risk of fire or electric shock. Installation of LED fixture requires knowledge of electrical systems. If not qualified, do not attempt installation. Contact qualified electrician. This luminaire must be installed in accordance to your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. LED Color Consistency Temperature Driver Dimming 2-Step MacAdam Ellipse Operating: -20 C to +40 C Startup: -20 C to +40 C Storage: -30 C to +60 C Relative 10-90% Humidity: (non-condensing) Integrated Between 10% and 100% via 0-10 VDC Components: i2cove Asymmetrical LED Light Fixtures 12.13 [308mm] End View 1. [41mm] * Fully programmable. Other options available. Physical Specifications PARAMETER Dimensions Housing Construction VALUE Length: 12.13 [308 mm], 36.13 [918 mm or 48.13 [1222 mm] Width: 3.2 [81 mm] Height: 1. [41 mm] Extruded Aluminum 36.13 [918mm] 48.13 [1222mm] 3.2 [81mm] Lens Construction Beam Angle Polycarbonate 120 Asymmetrical Flat Mounting Bracket CAB-1 (2 brackets supplied with each fixture) Weight Mounting Options Environment 1.45 lbs / Ft Allow [152 mm] for bend radius Flat Brackets (standard) Adjustable Brackets (option) Corner Kit (option) Indoor Use Only 1.37 [35mm] 1.9 [50mm] For surface mounting fixtures Secure with mounting screws Snap fixture into place CERTIFICATIONS Options: Adjustable Mounting Bracket CAB-2 1.63 [41mm] For surface mounting fixtures Four angle positions Secure with mounting screws (not included) Snap fixture into place MORE INFORMATION For additional specifications, wiring examples, available accessories, and warranty information, please visit www.i2systems.com or contact your i2systems representative..5 [14mm] Plug-In Corner Kit CAK-1 2.0 [52mm] Kit includes: Two end plates Armored cable assembly Mounting hardware

INSTALLATION INSTRUCTIONS 1 Verify the input current and fixture wattage. There is a label on each fixture which outlines the acceptable input voltage as well as the watts per foot at 50/60 Hz. The input Voltage AC and the wattage of the fixture will determine the fixture run length. Watts / Foot Exceeding the voltage input and acceptable fixture run lengths will result in damage to the lighting fixture and pose a serious safety hazard. Input 5W Max. Run 8W Max. Run 10W Max. Run 12W Max. Run 120 VAC 100 ft 60 ft 50 ft 40 ft 208VAC 100 ft 100 ft 80 ft 70 ft 240VAC 100 ft 100 ft 100 ft 80 ft 277 VAC 100 ft 100 ft 100 ft 90 ft Review the length of fixture(s) and cable(s). Power entry unit comes with a cable. Length Additional units are supplied with a jumper cable. Use supplied jumper cable 685-50140 to connect units together. Fixtures can be installed in a variety of configurations: linearly, around corners, or around curved spaces. Use Corner Kit CAK-1 for non-linear installations. Refer to Section A on page 4. Corner Kit cable is long.

INSTALLATION INSTRUCTIONS (CONT D) 2 Install mounting brackets to the building along the desired path of fixtures. Both fixed and adjustable mounting brackets are available. Fixed Bracket CAB-1. Two brackets are supplied with each fixture. Adjustable Bracket CAB-2 (optional). Secure using two screws (not included). Correctly position the angle of each bracket after snapping in the light. Use two screws per bracket (screws not included). Two brackets per fixture are recommended. 3 Install lights in a series, snapping lights into brackets and attaching ground clips between fixtures. Affix the brackets and snap down lights with the jumper cable attached. (Fixed bracket shown) Attach a ground clip provided such that it bridges two lights in series together. Gently tap the clip into place and then attach with a screw (not included). 4 Attach the dimming wires to the 0-10 VDC dimming supply. Do not use a higher voltage as this will result in damage to the fixture. If the dimming option is not used, attach wire nuts to cap off wires. The i2cove has the ability to dim 10% to 100%. Cut supplied 18 armored cable down (if needed) to reach building power junction box and protect wires on end with protective bushing. BLACK LINE WHITE NEUTRAL 120-277 VAC GREEN GROUND Junction box (supplied by others) GRAY VIOLET VDC (-) VDC (+) 3 rd Party Junction Box 3 rd PARTY 0-10 VDC DIMMER Dimming Optional

OPTIONAL COMPONENTS A Install the Corner Kit if you wish to go around a corner. Match the right and left plates with the light. Plug 6-position female connector into mating connector on light. (2 places) Using screws provided, mount plates to lights. (3 screws per plate) Maximum bend this position B Move Power Entry to other end of the light (optional). The power entry box and cable are supplied on the right side of the unit, but can be moved to the left. If you choose to keep it on the right side (as shipped), attach the Left End Plate and insert Hole Plug provided: Insert Hole Plug into End Plate. Using 3 screws, attach Left End Plate. Follow the instructions on the label: remove unused tab REMOVE AND DISCARD UNUSED TAB AFTER INSTALLATION. CAUTION: SHARP EDGES MAY RESULT. If you choose to move Power Entry to the left side, first, remove it from right side: Remove 2 mounting screws, unplug connector, and remove Assembly from right side. LEFT SIDE RIGHT SIDE Then, install Power Entry on left side: Using 3 screws, attach Right End Plate provided. Insert Hole Plug into End Plate. Plug into the mating connector on the right side and reattach Assembly using 2 screws. RIGHT SIDE Follow the instructions on the label: remove unused tab REMOVE AND DISCARD UNUSED TAB AFTER INSTALLATION. CAUTION: SHARP EDGES MAY RESULT. LEFT SIDE

Read and understand the installation instructions before attempting to install or use the fixture. It is the responsibility of the contractor, installer, purchaser, owner and user to install, maintain, and operate i2cove fixtures in such a manner as to comply with all applicable codes, state and local laws, ordinances, and regulations. Consult with the appropriate electrical inspector to ensure compliance. ELECTRICAL WARNINGS AND CAUTIONS DANGER: RISK OF ELECTRICAL SHOCK OR FIRE. DISCONNECT POWER BEFORE INSTALLATION. WARNING: Do not use a fixture for any voltage for which it is not rated. Do not exceed the specified voltage and current input for any fixture. Each unit contains a label outlining the fixture wattage. The label also contains the part number, date manufactured, and individual serial number assigned to the fixture. Model/Part Number Serial Number WARNING: Ensure that main power supply is off before installing or wiring a fixture. WARNING: Risk of fire or electric shock, installation requires knowledge of luminaire electrical systems. Luminaires must be installed by a qualified electrician according to local and national codes for proper installation. WARNING: Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling. WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Only use fixtures with voltage for which it is rated. Do not exceed the specified input voltage and current. Fixtures have line voltage risk of shock and no user serviceable parts. Do not attempt to open. Do not use a fixture if the lens, housing, or power cables are damaged. Do not hot swap fixtures. Ensure that power to the series is off before connecting or disconnecting individual fixtures. Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. i2systems accepts no responsibility for inadequately reinforced walls and/or ceilings. Do not make or alter any open holes in an enclosure of wiring or electrical components during installation. Wear proper safety equipment and follow appropriate safety precautions. Connect to a properly grounded branch circuit protected by a circuit breaker or fuse. Always use i2systems and/or i2systems-recommended electrical components. For use on systems with voltages greater than the maximum rated voltage, use a safety agency approved, step-down power supply to convert the higher voltage to a voltage within the specified operating range of the fixture. INSTALLATION / THERMALS Once installed, monitor the fixture case temperature. The fixture case temperature should not exceed 50 C at worst case ambient. Should the case temperature exceed the max rating of 50 C, do one or more of the following: reduce the ambient temperature, heatsink the fixture, increase the airflow or volume of air around the fixture, or remove the fixture and install a lower power fixture. Do not install the light fixture where any liquid will come in contact with the luminaire or the wiring. Do not install the light fixture where it will sit in any liquid or where liquid will collect, pool or puddle. Fixture is suitable for indoor dry locations only. It is recommended that the light fixture remain in its original container until it is ready to be installed. FCC NOTICE The hardware device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A device, pursuant to Part 15 of the FCC regulations. These limits are designed to provide reasonable protection against harmful interference in a residential or commercial installation. However there is no guarantee that interference will not occur in a particular installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed or used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio of television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient or relocate the receiving antennae; 2. Increase the separation between the equipment and the receiver; 3. Connect the equipment to an outlet on a circuit different from that to which the receiver is connected; 4. Consult the dealer or an experienced radio/tv technician for help. Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. Where shielded interface cables have been provided with the product or specified accessories elsewhere defined to be used with the installation of the product, they must be used in order to ensure compliance with FCC regulations. WARRANTY AND MAINTENANCE The linear lighting that you have purchased is a self-contained system; do not attempt to repair or disassemble the light. There is no recommended maintenance for this product. For a copy of our limited warranty please visit www.i2systems.com.