ELITE SERIES Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

Similar documents
ELITE SERIES Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

G60UHV. DAVE LENNOX SIGNATURE COLLECTION Up Flow / Horizontal Two Stage Heat Variable Speed Blower G A S F U R N A C E S

ELITE SERIES Multi Position Two Stage Heat Variable Speed Blower

G23 Bulletin # September 1998 Supersedes June 1995

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

G21Q Bulletin # April 1997 Supersedes # October 1994

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

G21Q Bulletin # September 1992 Supersedes March 1992

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

G21Q ENGINEERING DATA. Typical Applications. Bulletin # March 1993

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Cooling Capacity CFM in. w.c. (125 Pa)

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

G8MVL. Product Specifications

KG7T (E and N Series)

ELITE Series R-410A - Upflow / Horizontal

FG7T (E and N Series)

FG7S (C and L Series)

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Typical Applications. Horizontal Installation

ELITE SERIES R-410A Ready - Multi-Position

TSTAT0101SC Recommended (sold separately)

AF90. AF90 Gas Furnace High Efficiency. Features

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

G9MXE. Product Specifications

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

KG7T (C and L Series)

G9MXE. Product Specifications

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

13 GCS X A X Nominal SEER Minor Revision Number

KG7T (C and L Series)

DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

F8MTL. Product Specifications

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

N9MPD Product Specifications

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Table of Contents GF801U Series

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

93% Gas Furnaces Single Stage

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

2SG13 60HZ P A C K A G E D G A S / E L E C T R I C

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

Multi-Position, Multi-Speed Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

FG7T (A and K Series)

GMS9/GCS9 SERIES 93% AFUE

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

FG7T (A and K Series)

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

Upflow, Upflow / Horizontal, Counterflow / Horizontal

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

KG7S (A and K Series)

UPFLOW/ HORIZONTAL GAS FURNACE

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

Transcription:

PRODUCT SPECIFICATIONS GAS FURNACES EL96UHV ELITE SERIES Upflow / Horizontal - Two-Stage Heat - Variable Blower Bulletin No. 069 April 05 Supersedes January 05 MODEL NUMBER IDENTIFICATION EL 96 UH 070 X V 36 B AFUE - 96% Input - 44,000 to 3,000 Btuh Nominal Add-on - to 5 Tons Unit Type EL = Elite Series Stages = Two-Stage AFUE 96 = 96% Configuration UH = Upflow/Horizontal Nominal Gas Heat Input 045 = 44,000 Btuh 070 = 66,000 Btuh 090 = 88,000 Btuh 0 = 0,000 Btuh 35 = 3,000 Btuh Cabinet Width B = 7-/ in. C = in. D = 4-/ in. Nominal Add-On Capacity 4 = tons 36 = 3 tons 48 = 4 tons 60 = 5 tons Blower V = Variable Blower Motor Low NO x X = Units meet California Nitrogen Oxides standards Indoor coils with the same letter designation will physically match the furnace.

FEATURES K B CONTENTS D Blower Data... 3 Dimensions - Horizontal Position... 7 H Dimensions - Upflow Position... 6 F E C Features... Gas Heat Accessories... Altitude Derate... Installation Clearances... 0 G M Model Number Identification... Optional Accessories... Optional Accessory Dimensions... 8 Specifications... 9 L I Vent Lengths... 3 J WARRANTY Duralok Plus Aluminized Steel Heat Exchanger Limited Lifetime warranty in residential applications (twenty year transferable), ten years in non-residential applications. All other covered components - Limited Five Year warranty in residential applications, one year in nonresidential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. APPROVALS Units are Certified by AHRI. Units are Certified by CSA International. Units tested and rated according to US DOE test procedures and FTC labeling regulations. Approved by the California Energy Commission and meets California Nitrogen Oxides (NOx) Standards. Energy Star certified units are designed to use less energy, help save money on utility bills, and help protect the environment. ISO 900 Registered Manufacturing Quality System. Blower data from unit tests conducted in Lennox Laboratory air test chamber. EL96UHV / Page APPLICATIONS Input capacities of 44,000, 66,000, 88,000, 0,000 and 3,000 Btuh. Energy efficiency (AFUE) of 96%. Compact cabinet for upflow, horizontal-left or horizontalright applications without any modifications. Removable bottom seal panel shipped in place for side return air is easily removed for bottom/end return air applications. Utility room, alcove, closet, crawl space, basement or attic installation. Lennox add-on indoor coils, high-efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with all controls installed and wired. Each unit factory test operated to ensure proper operation. NOTE - FURNACES CANNOT BE TWINNED! Zoning Applications The EL96UHV furnace can be used with the Lennox iharmony Zoning System with the icomfort Wi-Fi thermostat. The iharmony Zoning System provides direct feedback to the furnace, controlling both airflow and heat output to match the comfort requirements for up to four zones.

B C D FEATURES HEATING SYSTEM Lennox Duralok Plus Heat Exchanger Assembly Lennox developed heat exchanger assembly consists of primary heat exchanger and secondary condenser coil assembly. Main multi-pass crimped seam design clamshell type heat exchanger. Constructed of heavygauge, aluminized steel. Designed for normal expansion and contraction with maximum efficiency and minimum resistance to air flow. Secondary heat exchanger condenser coil constructed of aluminum fins fitted to stainless steel tubes. Coil is factory tested for leaks. Condensate drain header box assembly located on front of coil. Compact size of complete heat exchanger assembly permits low overall design of furnace cabinet. Heat exchanger assembly has been laboratory life cycle tested in excess of industry standards. Lennox Designed Header Box Header box on end of condenser coil collects flue condensate for disposal through condensate drains. The drains are located on each side of the cabinet for easy field installation of condensate drain trap. Only one drain is used, the other drain is sealed. Condensate drain trap is included with the unit for field installation. Lennox Designed Flue Condensate Trap Assembly Condensate trap assembly is mounted outside the conditioned air stream. Assembly can be mounted on either side of cabinet in upflow applications. Assembly is mounted below the cabinet in horizontal applications. Can also be mounted remotely (up to 5 ft. away) from unit. See Installation Instructions. 90 street elbow furnished for ease of drain trap installation. Drain connection can be made with field provided PVC pipe, PVC coupling, or vinyl tubing with hose clamp. Drain cap on trap allows easy cleaning and winterizing. Inshot Burners Aluminized steel inshot burners provide efficient, trouble-free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. E F G H SureLight Hot Surface Ignitor Tough, reliable, long-life, trouble-free performance. Silicon nitride ignitor. Cemented to steatite block for protection against current leakage. Ignition leads are constructed of nickel plated copper and are enclosed in high temperature Teflon insulation for dependable operation. Two-Stage Gas Control Valve 4 volt redundant combination two-stage gas control valve combines manual shut off switch (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. Two- Combustion Air Inducer Permanent split capacitor (PSC), heavy duty blower prepurges heat exchanger and safely vents flue products. Dual pressure switches (low fire/high fire) prove blower operation before allowing gas valve to open. Operates only during heating cycle. Flame Rollout Switches () Manual reset switches are factory installed on burner box. Switch provides protection from abnormal operating conditions. Limit Control Automatic reset, primary limit is accurately located on vestibule panel on all units. Optional Accessories Altitude Orifice Kits Required on all units for proper unit operation at altitudes from 750 to 0,000 ft. Kits are available for natural gas and LPG/propane. Altitude Pressure Switch Kit Required for proper unit operation on installations above 4500 ft. Natural Gas to LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/ Propane. LPG/Propane to Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. EL96UHV / Page 3

FEATURES DIRECT VENT / NON-DIRECT VENt SEALED COMBUSTION SYSTEM Furnace features a sealed combustion system and can be installed in either Direct Vent or Non-Direct applications. In Direct Vent applications, combustion air is supplied from outdoors and flue gases are discharged outdoors. In Non-Direct Vent applications, combustion air is supplied from indoors and flue gases are discharged outdoors. NOTE - Lennox has approved the use of DuraVent PolyPro manufactured vent pipe and terminations as an alternative to PVC vent pipe. Must be ordered separately. Tested and listed to the ULC S636 standard in Canada. The PolyPro venting system must follow the uninsulated and unconditioned space vent lengths listed in the table on Page 3. Refer to the Installation Instructions for additional details. Optional Accessories Termination Kits Facilitates installation of combustion air intake pipe and flue exhaust pipe. Refer to venting table in this bulletin to determine pipe size needed and proper termination kit required. Certain Termination Kits are certified to ULC S636 standard for use in Canada only. See Optional Accessories table and dimension drawings. Termination Kit - Concentric - Direct Vent Applications or 3 inch kit contains concentric termination assembly, reducer bushing and 45 degree elbow. inch kit for -045-070 models contains an outdoor exhaust accelerator. Kit requires single hole penetration of roof or wall for installation. Roof Termination Flashing Kit is available for use with inch Kits. CSA certified. Termination Kit - Flush-Mount Kit contains flush-mount termination, accelerator, mounting template and hardware. Kit may be used with, -/ or 3 in. pipe. Termination Kits - Wall Assembly Close Couple (US Only) - Direct Vent Applications or 3 inch kit consists of close-couple, side-by-side PVC piping with galvanized steel wall cover plate for sealing and isolating piping penetration of the wall. Piping spacing and length is sized for proper wall installations. CSA certified. EL96UHV / Page 4 I Close Couple WTK (Canada Only) - Direct Vent Applications or 3 inch kit contains one insulated faceplate, one insulated exhaust pipe, elbow and fittings. Certified to ULC S636 standard. Wall Ring - Direct Vent or Non-Direct Vent Applications inch kit contains stainless steel outside seal caps, galvanized steel inside seal caps, 4 seal rings for the caps and 8 inch insulation sleeve for sealing and isolating intake and exhaust piping penetration of wall. Maintain a maximum of 6 inches between the inlet and outlet openings in the installation of the pipes. Roof Termination Flashing Kit 3 inch kit contains two neoprene rubber roof flashings for vertical venting through a roof. Vent pipe and insulation not furnished. Flashing Kit can also be used with inch Concentric Vent Termination Kits used in vertical venting rooftop applications. CONTROLS SureLight Control (icomfort Compatible) Advanced control communicates information about various operating parameters in the furnace to the optional icomfort Wi-Fi Thermostat to constantly maintain the highest level of comfort and performance available. Auto Configuration - On startup the control automatically sends a description of the unit to the optional icomfort Wi-Fi Thermostat to automatically configure the number of stages and features available. Connections for connecting a conventional heating/ cooling thermostat are also provided on the control. Control also features Innovative AirFlex technology which allows custom blower settings based on the application. Thermostat Control - For optimal performance, the use of a high-quality, digital two-stage thermostat with adjustable settings for first stage/second stage, on/off differentials and adjustable stage timers is recommended. Furnace Input Staging Options Thermostat Type Input Staging Available icomfort Wi-Fi Thermostat Two-Stage (Conventional) Single-Stage (Conventional) Two-Stage (65 and 00%)

FEATURES CONTROLS (continued) Safety Controls - Flame sensor utilizes flame rectification for safe and reliable operation. Should flame fail to ignite, control will initiate 4 reattempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition control after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Display LED - Seven segment LED displays alphanumeric information related to diagnostics as well as system operation and status. Diagnostic codes are held in non-volatile memory, immune from power interruptions. Holds up to ten diagnostic codes in order of occurrence for recall on demand. Port on blower door allows for easy viewing. Select Thermostat used - Single-Stage or Two-Stage. Two selectable second stage recognition times (7 and minutes) are available on the control when the furnace is used with a single-stage thermostat. When used with a two-stage thermostat, furnace will only initiate second stage operation with a second stage thermostat demand. Heating s - A combination of DIP switch settings allow the following motor speed selection settings within the heating speed selected for fine tuning air volume: Factory default 6%, %, 8% or 4% increase 6%, % or 8% decrease See Blower Performance tables. s - A combination of DIP switch settings allow the following motor speed selection settings within the cooling speed selected for fine tuning air volume: Factory default 0% increase 0% decrease See Blower Performance tables. Blower Ramping ( Mode) - DIP switch settings allow one of four blower speed profiles during cooling operation. Profile A (factory setting) - Motor runs at 50% for 30 seconds, then at 8% for 7-/ minutes, then at 00% (if needed) until demand is satisfied. Once demand is met, motor runs at 50% for 30 seconds, then ramps down to stop. Profile B - Motor runs at 8% for 7-/ minutes and then at 00% (if needed) until demand is satisfied. Once demand is met,motor ramps down to stop. Profile C - Motor runs at 00% until demand is satisfied. Once demand is met, motor runs at 00% for 60 seconds, then ramps down to stop. Profile D - Motor runs at 00% until demand is satisfied. Once demand is met, motor ramps down to stop. Dehumidification (Active or Humiditrol Option) - A jumper on the control must be clipped to enable active dehumidification and/or operation with a Humiditrol Whole-Home Dehumidification System. A humidity controlling thermostat or device is also required. During a call for cooling, air volume is automatically reduced, forcing humidity removal by the air conditioner or heat pump system (single stage units or two-stage units running at nd stage). After the humidity has reached the desired set-point the cooling air volume returns to its designed rate. A dehumidification signal from the thermostat reduces the cooling cfm to 70% of the requested cooling cfm. Dual-Fuel Operation - A jumper on the control must be clipped to enable operation with a single or two-stage heat pump. The indoor blower is started without delay when a call for heat is received. Two-Stage Compressor Operation - A jumper on the control must be clipped to enable operation with a two-stage compressor. The cooling blower speeds for first and second stage cooling will be dictated by the applicable DIP switch settings. Lennox System Operations Monitor Connection - Monitors outdoor unit operation (communicating mode). Blower On/Off Time (Heating) - Blower on time is fixed at 30 seconds, blower off time is adjustable from 60, 90, 0 and 80 seconds (factory setting - 90 seconds). Blower On/Off Time () - For air-conditioning applications, blower on time is seconds following thermostat demand for cooling. See Blower Ramping ( Mode) profiles for various blower off details. Controls evaporator humidity by controlling blower and compressor speed on two-stage outdoor units when used with the icomfort Wi-Fi thermostat or the ComfortSense 7000 thermostat. Continuous Blower - Adjustable continuous blower speed is a percentage of the high cooling speed selection. There are four selectable options (via DIP switch settings) of 8%, 38% (default setting), 70% and 00%. Accessory Terminal - One accessory terminal furnished for additional power supply requirements for 0 volt (less than amp) powered air cleaners. One unpowered pair of contacts are provided for humidifier connections and may be connected to 4V or 0V. Control is factory installed in the unit control box. 4 Volt Transformer Furnished and factory installed in control box. 40VA transformer has circuit breaker wired in series. Field Wiring Make-Up Box Furnished for line voltage wiring. EL96UHV / Page 5

FEATURES Factory installed internally on left side of furnace. Box may be installed internally or externally on either side of furnace. CONTROLS (continued) Optional Accessories icomfort Wi-Fi Thermostat (part of the icomfort Residential Communicating Control System) The icomfort Wi-Fi Thermostat recognizes and connects to all icomfort -enabled products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort -enabled products to simplify system installation. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Service alerts and reminders sent via text message or e-mail. Dealer Dashboard features online real-time monitoring of installed icomfort systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Easy to read 7-inch color screen (measured diagonally). Conventional outdoor units (not icomfort -enabled) can easily be added and controlled by the icomfort Wi-Fi Thermostat. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 8-gauge standard thermostat wiring. See the icomfort Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. ComfortSense 7000 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/ Cool. Auto-changeover. Controls humidity during cooling mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. Remote outdoor temperature sensor (optional) allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol applications. See the ComfortSense 7000 Product Specifications bulletin in the Controls section for more information. Outdoor Air Temperature Sensor Used with icomfort Wi-Fi Thermostat and ComfortSense 7000 thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. NOTE - Sensor is required for Humiditrol applications. Thermostat Thermostat (icomfort Wi-Fi Thermostat or programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. Night Service Kit Contains most commonly used service parts: Furnace control Igniter Flame sensor Gas valve Transformer Service Manual MODE SCHED HOME SCHEDULE OPTIONS AUTO ON INDOOR RH 6% WED AN :35AM SET AT HEAT SET AT COOL Universal Service Kit - Switches Kit contains: Primary limits (for each model) Pressure switches (for each model) Flame rollout switches (for each model) EL96UHV / Page 6

FEATURES J K L M BLOWER Variable Direct Drive Blower. Each blower assembly statically and dynamically balanced. Change in blower speed is easily accomplished by simple DIP switch change on furnace control. See Blower Data tables. Blower assembly easily removed for servicing. Variable Blower Motor Variable speed motor maintains specified air volume from 0 though 0.8 in. w.g. (heating) and 0 through.0 in. w.g. () static range. Variable speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Motor is controlled by furnace control. Motor is resiliently mounted. When furnaces are used with the iharmony Zoning System and the icomfort Wi-Fi Thermostat, the blower motor operates from predetermined minimum - maximum air volumes to satisfy zone requirements. CABINET Low-profile, narrow width cabinet allows easy installation in upflow or horizontal applications. Heavy-gauge, cold rolled steel construction. Pre-painted cabinet finish. Flanges provided on supply air opening for ease of plenum connection or alignment with indoor coil. Fully insulated cabinet with foil faced insulation on sides and back of heating compartment and mat faced insulation in blower compartment. Sealed blower compartment. Inner blower compartment access panel seals blower compartment from air leakage. Cabinet door can be removed without any tools.. Complete service access. Safety interlock switch automatically shuts off power to unit when blower compartment access door is removed. Gas piping and electrical inlets are provided in both sides of cabinet.. Single side return air with transition, to accommodate 0 x 5 x in. cleanable air filter. Required to maintain proper air velocity.. Single side return air with Optional Return Air Base 3. Bottom return air. 4. Return air from both sides. 5. Bottom and one side return air. See Blower Data Tables for additional information. Coil Match-Up All furnaces exactly match C33 and CX34 cased upflow indoor coils and CH33 horizontal indoor coils with same letter designation in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. C33 uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace opening. See C33 coil bulletin for additional information. Low Leakage Cabinet All models have less than % air leakage and meet ANSI/ASHRAE Standard 93-00 Method of Test for Determining the Air Tightness of HVAC Equipment. Return Air Entry: For bottom/end return-air entry for upflow/horizontal applications, remove furnished bottom seal panel from cabinet. For side return-air entry (upflow applications only), corners are marked on either side of cabinet for return air cut-outs. See Dimension Drawing. NOTE - 60C and 60D size units that require air volumes over 800 cfm must have one of the following: EL96UHV / Page 7

FEATURES CABINET (continued) Optional Accessories Condensate Drain Heat Cable Kits Self-limiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. Available in 6 or 4 ft. lengths. Horizontal Suspension Kit Provides suspension of unit and indoor coil in horizontal applications. Allows complete service access. Consists of corner mounted hanging brackets with vibration isolators, return air end support rail and hardware for assembly. Metal hanging straps must be field provided. Crawl Space Vent Drain Kit Allows venting through a crawl space for upflow and horizontal applications. Includes or 3 in. sanitary tee, in. PVC assembly, PVC boot and clamp. Return Air Base On furnaces with side return air and condensate trap on the same side of the cabinet, a field fabricated transition or Return Air Base is required when using an IAQ product higher than 4-3/6 in. installed next to the unit and serviced from the front. IAQ products higher than 0 in. require a field fabricated transition. Must be used for 60C and 60D models with air volumes over 800 cfm in upflow applications when only one side return is required. Cabinet is shipped flat for easy field assembly and is pre-painted steel to match the furnace. See Dimension Drawing. FILTER (not furnished) Filter and provisions for external mounting must be field provided. Optional Accessories Air Filter and Rack Kit for Horizontal Return Air (End) Applications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See Dimension Drawing. Air Filter and Rack Kit for Upflow Side Return Air Applications - Not for use with Return Air Base Washable or vacuum cleanable polyurethane frame type filter and external side return air rack available for field installation. Available in single and ten pack kits. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. Field installs on either side of unit cabinet. See Dimension Drawing. EL96UHV / Page 8

SPECIFICATIONS Gas Heating Performance Fire Low Fire Model No. EL96UH045XV36B EL96UH070XV36B EL96UH090XV36C AFUE 96% 96% 96% Input - Btuh 44,000 66,000 88,000 Output - Btuh 4,000 6,000 84,000 Temperature rise range - F 35-65 50-80 30-60 Gas Manifold Pressure (in. w.g.) 3.5 / 0.0 3.5 / 0.0 3.5 / 0.0 Nat. Gas / LPG/Propane Input - Btuh 9,000 43,000 57,000 Output - Btuh 8,000 4,000 55,000 Temperature rise range - F 0-50 5-55 30-60 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane.7 / 4.9.7 / 4.9.7 / 4.9 static - in. w.g. Heating 0.8 0.8 0.8.0.0.0 Connections in. Indoor Blower Intake / Exhaust Pipe (PVC) / / / Gas pipe size IPS / / / Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 3/4 with furnished 90 street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt with field supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT Wheel nominal diameter x width - in. 0 x 9 0 x 9 0 x 9 Motor output - hp / / / Tons of add-on cooling - 3-3 - 3 Air Volume Range - cfm 465-370 490-365 50-360 Electrical Data Voltage 0 volts - 60 hertz - phase Blower motor full load amps 7.7 7.7 7.7 Maximum overcurrent protection 5 5 5 Shipping Data lbs. - package 30 36 5 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. SPECIFICATIONS Gas Heating Performance Fire Low Fire Model No. EL96UH090XV48C EL96UH090XV60C EL96UH0XV48C AFUE 96% 96% 96% Input - Btuh 88,000 88,000 0,000 Output - Btuh 85,000 85,000 05,000 Temperature rise range - F 45-75 40-70 60-90 Gas Manifold Pressure (in. w.g.) 3.5 / 0.0 3.5 / 0.0 3.5 / 0.0 Nat. Gas / LPG/Propane Input - Btuh 57,000 57,000 7,000 Output - Btuh 55,000 55,000 70,000 Temperature rise range - F 30-60 30-60 36-65 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane.7 / 4.9.7 / 4.9.7 / 4.9 static - in. w.g. Heating 0.8 0.8 0.8.0.0.0 Connections in. Indoor Blower Intake / Exhaust Pipe (PVC) / / / Gas pipe size IPS / / / Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 3/4 with furnished 90 street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt with field supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT Wheel nominal diameter x width - in. x x x Motor output - hp 3/4 3/4 Tons of add-on cooling.5-4 3-5.5-4 Air Volume Range - cfm 680-770 840-95 670-760 Electrical Data Voltage 0 volts - 60 hertz - phase Blower motor full load amps 0..8 0. Maximum overcurrent protection 5 0 5 Shipping Data lbs. - package 63 64 73 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. EL96UHV / Page 9

SPECIFICATIONS Gas Heating Performance Fire Low Fire Model No. EL96UH0XV60C EL96UH35XV60D AFUE 96% 96% Input - Btuh 0,000 3,000 Output - Btuh 06,000 6,000 Temperature rise range - F 45-75 55-85 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane 3.5 / 0.0 3.5 / 0.0 Input - Btuh 7,000 86,000 Output - Btuh 70,000 84,000 Temperature rise range - F 35-65 40-70 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane.7 / 4.9.7 / 4.9 static - in. w.g. Heating 0.8 0.8 Connections in. Indoor Blower.0.0 Intake / Exhaust Pipe (PVC) / / Gas pipe size IPS / / Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 with furnished 90 street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt with field supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT Wheel nominal diameter x width - in. x x Motor output - hp Tons of add-on cooling 3-5 3-5 Air Volume Range - cfm 850-5 950-50 Electrical Data Voltage 0 volts - 60 hertz - phase Blower motor full load amps.8.8 Maximum overcurrent protection 0 0 Shipping Data lbs. - package 74 88 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. INSTALLATION CLEARANCES - INCHES (MM) Sides Rear Top/Plenum Front Front (service/alcove) Floor 0 inches (0 mm) 0 inches (0 mm) inch (5 mm) 0 inches (0 mm) 4 inches (60 mm) Combustible NOTE Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI Z3.) or the National Standard of Canada CAN/CSA B49. Natural Gas and Propane Installation Code. NOTE In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ ANSI Z3.) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA B49.. Allow proper clearances to accommodate condensate trap and vent pipe installation. Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring. EL96UHV / Page 0

OPTIONAL ACCESSORIES - ORDER SEPARATELY NOTE - FURNACES CANNOT BE TWINNED! CABINET ACCESSORIES B Width Models C Width Models D Width Models Horizontal Suspension Kit - Horizontal only 5W0 5W0 5W0 Return Air Base - Upflow only 50W98 50W99 5W00 CONDENSATE DRAIN KITS Condensate Drain Heat Cable 6 ft. 6K68 6K68 6K68 4 ft. 6K69 6K69 6K69 Crawl Space Vent Drain Kit 5W8 5W8 5W8 CONTROLS icomfort Wi-Fi Thermostat 0F8 0F8 0F8 Remote Outdoor Air Temperature Sensor (for dual fuel and Humiditrol ) X658 X658 X658 Discharge Air Temperature Sensor 88K38 88K38 88K38 ComfortSense 7000 Thermostat Y08 Y08 Y08 3 Remote Outdoor Temperature Sensor (for dual fuel and Humiditrol) FILTER KITS 4 Air Filter and Rack Kit NIGHT SERVICE KIT X658 X658 X658 Horizontal (end) Size of filter - in. 87L96-8 x 5 x 87L97-0 x 5 x 87L98-5 x 5 x Side Return Single 44J 44J 44J Ten Pack 66K63 66K63 66K63 Size of filter - in. 6 x 5 x 6 x 5 x 6 x 5 x Night Service Kit 84W49 84W49 84W49 Universal Service Kit - Switches 89W0 89W0 89W0 TERMINATION KITS See Installation Instructions for specific venting information. Termination Kits - Direct Vent Applications Only Termination Kits - Direct or Non- Direct vent Concentric US - in. 7M80 69M9 - - - 3 in. - - - 60L46 60L46 Canada - in. 44W9 44W9 - - - 3 in. - - - 44W93 44W93 Flush-Mount US -, -/ or 3 in. 5W 5W 5W Wall - Close Couple Wall - Close Couple WTK 5 Roof Termination Flashing Kit - Direct or Non-Direct Vent ( flashings) Canada -, -/ or 3 in. 5W 5W 5W US - in. G44 - - - - - - 3 in. 44J40 44J40 44J40 Canada - in. 30G8 - - - - - - 3 in. 8J0 8J0 8J0 Roof in. 5F75 5F75 - - - Wall Ring Kit in. 5F74 6 5F74 - - - 3 in. 44J4 44J4 44J4 Remote Outdoor Sensor may be used with an icomfort -enabled outdoor unit for a secondary (alternate) sensor reading. Sensor may also be used with a conventional outdoor unit. Optional for service diagnostics. 3 Remote Outdoor Temperature Sensor for ComfortSense 7000 Thermostat must be connected directly to the thermostat, Do not connect it directly to the SureLight control. 4 Cleanable polyurethane, frame-type filter. 5 Kits contain enough parts for two, non direct vent installations. 6 Non-direct vent only. NOTE - Termination Kits 44W9, 44W93, 30G8, 5W, 5W9, 8J0 are certified to ULC S636 standard for use in Canada only. EL96UHV / Page

GAS HEAT ACCESSORIES Input Altitude Pressure Switch Kit Natural Gas to LPG/Propane Kit LPG/Propane to Natural Gas Kit Natural Gas Altitude Orifice Kit LPG/Propane Altitude Orifice Kit 450-7500 ft. 750-0,000 ft. 0-7500 ft. 0-7500 ft. 750-0,000 ft. 750-0,000 ft. 045 93W8 93W84 78W93 77W09 73W37 78W96 070 X65 98W79 78W93 77W09 73W37 78W96 090 93W8 93W80 78W93 77W09 73W37 78W96 0 93W80 93W85 78W93 77W09 73W37 78W96 35 93W83 93W85 78W93 77W09 73W37 78W96 HIGH ALTITUDE DERATE NOTE - Units may be installed at altitudes up to 0,000 ft. At altitudes above 450 ft. the unit must be derated to match the manifold pressure information shown below. Units installed at altitudes of 450 to 0,000 ft. require a pressure switch change. Units installed at altitudes of 750 to 0,000 ft. require an orifice change. See the Gas Heat Accessories table for ordering information. NOTE - This is the only permissible derate for these units. NOTE - In Canada, certification for installations at elevations over 4500 feet is the jurisdiction of local authorities. Input All Sizes Gas Manifold Pressure in. w.g. 0-4500 ft. 450-5500 ft. 550-6500 ft. 650-7500 ft. 750-0,000 ft. Low Fire Fire Low Fire Fire Low Fire Fire Low Fire Fire Low Fire Fire Supply Line Pressure in. w.g. 0-0,000 ft. Natural.7 3.5.6 3.3.5 3..5 3..7 3.5 4.5 3.0 LPG/Propane 4.9 0.0 4.6 9.4 4.4 9. 4.3 8.9 4.9 0.0.0 3.0 Min. Max. EL96UHV / Page

OUTDOOR TERMINATION KIT USAGE Input Size 045 070 090 0 Vent Pipe Diameter (in.) Flush Mount Kit 5W (US) 4 5W (CA) Standard Terminations Wall Kit Wall Ring Kit inch 3 inch inch G44 (US) 4 30G8 (CA) 44J40 (US) 4 8J0 (CA) 5F74 Field Fabricated Exhaust Accelerator Size Required Concentric Terminations Concentric Kit -/ inch inch 3 inch 7M80 (US) 4 44W9 (CA) 69M9 (US) 4 44W9 (CA) 60L46 (US) 4 44W93 (CA) 3 YES YES YES YES -/ in. YES - - - - - - -/ 3 YES YES YES YES -/ in. YES - - - - - - 3 3 YES YES YES YES -/ in. YES - - - - - - 3 YES YES YES YES -/ in. YES - - - - - - -/ 3 YES YES YES YES -/ in. YES - - - - - - 3 3 YES YES YES YES -/ in. YES - - - - - - 3 YES - - - YES YES in. - - - YES YES -/ 3 YES - - - YES YES in. - - - YES YES 3 3 YES - - - YES YES in. - - - YES YES YES - - - YES YES in. - - - YES YES -/ YES - - - YES - - - in. - - - YES YES 3 YES - - - YES - - - in. - - - YES YES 35 3 YES - - - YES - - - in. - - - - - - YES NOTE - Standard Terminations do not include any vent pipe or elbows external to the structure. Any vent pipe or elbows external to the structure must be included in total vent length calculations. See Vent Length Tables. Requires field provided -/ in. outdoor exhaust accelerator. Concentric Kits 7M80 and 44W9 include -/ in. outdoor exhaust accelerator, required when used with 045 and 070 input models. Accelerator is not used with 090, 0, 35 input models. 3 Flush Mount Kit 5W and 5W includes -/ in. outdoor exhaust accelerator, required when used with 045, 070 and 090 input models. Accelerator is not used with 0 or 35 input models. 4 Termination Kits 30G8, 44W9, 44W93, 5W and 8J0 are certified to ULC S636 standard for use in Canada only. VENT LENGTHS - UNINSULATED EXHAUST PIPE IN UNCONDITIONED SPACE Winter Design Temperatures 3 to F 0 to F 0 to 0 F Vent Pipe Diameter Unit Input Size 045 070 090 0 35 Maximum Un-Insulated Exhaust Vent Length (ft.) PVC PolyPro PVC PolyPro PVC PolyPro PVC PolyPro PVC PolyPro in. 0 8 30 8 40 36 4 4 N/A N/A -/ in. 5 N/A N/A 30 N/A 40 N/A N/A N/A 3 in. 0 8 5 5 3 8 3 3 in. 0 8 5 4 4 N/A N/A -/ in. 0 N/A 4 N/A 0 N/A 4 N/A N/A N/A 3 in. 6 5 0 8 5 0 7 0 8 in. 8 7 8 6 0 N/A N/A -/ in. 6 N/A 8 N/A N/A 6 N/A N/A N/A 3 in. 6 5 0 0 Refer to 99% Minimum Design Temperature table provided in the current edition of ASHRAE Handbook-Fundamentals. PolyPro poly-propylene vent pipe is a registered tradmeark of DuraVent. EL96UHV / Page 3

VENT LENGTHS - FEET STANDARD TERMINATION AT ELEVATION 0-4500 ft. Pipe Size in. -/ in. 3 in. Input 045 070 090 0 35 045 070 090 0 35 045 070 090 0 35 No. of 90 ELL 8 66 44 4 N/A 5 5 93 58 N/A 38 37 8 8 4 76 6 39 9 N/A 0 0 88 53 N/A 33 3 3 3 09 3 7 56 34 4 N/A 05 05 83 48 N/A 8 7 08 08 04 4 66 5 9 N/A N/A 00 00 78 43 N/A 3 03 03 99 5 6 46 4 N/A N/A 95 95 73 38 N/A 8 7 98 98 94 6 56 4 9 N/A N/A 90 90 68 33 N/A 3 93 93 89 7 5 36 4 N/A N/A 85 85 63 8 N/A 08 07 88 88 84 8 46 3 N/A N/A N/A 80 80 58 3 N/A 03 0 83 83 79 9 4 6 N/A N/A N/A 75 75 53 8 N/A 98 97 78 78 74 0 36 N/A N/A N/A 70 70 48 3 N/A 93 9 73 73 69 STANDARD TERMINATION ELEVATION 450-0,000 ft. Pipe Size in. -/ in. 3 in. Input 045 070 090 0 35 045 070 090 0 35 045 070 090 0 35 No. of 90 ELL 8 66 44 N/A N/A 5 5 93 58 N/A 38 37 8 8 4 76 6 39 N/A N/A 0 0 88 53 N/A 33 3 3 3 09 3 7 56 34 N/A N/A 05 05 83 48 N/A 8 7 08 08 04 4 66 5 9 N/A N/A 00 00 78 43 N/A 3 03 03 99 5 6 46 4 N/A N/A 95 95 73 38 N/A 8 7 98 98 94 6 56 4 9 N/A N/A 90 90 68 33 N/A 3 93 93 89 7 5 36 4 N/A N/A 85 85 63 8 N/A 08 07 88 88 84 8 46 3 N/A N/A N/A 80 80 58 3 N/A 03 0 83 83 79 9 4 6 N/A N/A N/A 75 75 53 8 N/A 98 97 78 78 74 0 36 N/A N/A N/A 70 70 48 3 N/A 93 9 73 73 69 CONCENTRIC TERMINATION AT ELEVATION 0-4500 ft. Pipe Size in. -/ in. 3 in. Input 045 070 090 0 35 045 070 090 0 35 045 070 090 0 35 No. of 90 ELL 73 58 4 N/A 05 05 89 54 N/A 4 4 05 68 53 37 7 N/A 00 00 84 49 N/A 6 6 09 09 00 3 63 48 3 N/A 95 95 79 44 N/A 04 04 95 4 58 43 7 N/A N/A 90 90 74 39 N/A 06 06 99 99 90 5 53 38 N/A N/A 85 85 69 34 N/A 0 0 94 94 85 6 48 33 7 N/A N/A 80 80 64 9 N/A 96 96 89 89 80 7 43 8 N/A N/A 75 75 59 4 N/A 9 9 84 84 75 8 38 3 N/A N/A N/A 70 70 54 9 N/A 86 86 79 79 70 9 33 8 N/A N/A N/A 65 65 49 4 N/A 8 8 74 74 65 0 8 3 N/A N/A N/A 60 60 44 N/A N/A 76 76 69 69 60 CONCENTRIC TERMINATION ELEVATION 450-0,000 ft. Pipe Size in. -/ in. 3 in. Input 045 070 090 0 35 045 070 090 0 35 045 070 090 0 35 No. of 90 ELL 73 58 4 N/A N/A 05 05 89 54 N/A 4 4 05 68 53 37 N/A N/A 00 00 84 49 N/A 6 6 09 09 00 3 63 48 3 N/A N/A 95 95 79 44 N/A 04 04 95 4 58 43 7 N/A N/A 90 90 74 39 N/A 06 06 99 99 90 5 53 38 N/A N/A 85 85 69 34 N/A 0 0 94 94 85 6 48 33 7 N/A N/A 80 80 64 9 N/A 96 96 89 89 80 7 43 8 N/A N/A 75 75 59 4 N/A 9 9 84 84 75 8 38 3 N/A N/A N/A 70 70 54 9 N/A 86 86 79 79 70 9 33 8 N/A N/A N/A 65 65 49 4 N/A 8 8 74 74 65 0 8 3 N/A N/A N/A 60 60 44 N/A N/A 76 76 69 69 60 EL96UHV / Page 4

VENT LENGTHS (EXHAUST) - VENTILATED ATTIC OR CRAWLSPACE INTAKE AIR - FEET STANDARD TERMINATION AT ELEVATION 0-4500 ft. Pipe Size in. -/ in. 3 in. Input 045 070 090 0 35 045 070 090 0 35 045 070 090 0 35 No. of 90 ELL 7 56 34 4 N/A 00 00 78 43 N/A 8 7 98 98 94 66 5 9 9 N/A 95 95 73 38 N/A 3 93 93 89 3 6 46 4 4 N/A 90 90 68 33 N/A 08 07 88 88 84 4 56 4 9 N/A N/A 85 85 63 8 N/A 03 0 83 83 79 5 5 36 4 N/A N/A 80 80 58 3 N/A 98 97 78 78 74 6 46 3 9 N/A N/A 85 75 63 8 N/A 93 9 73 73 69 7 4 6 4 N/A N/A 70 70 48 3 N/A 88 87 68 68 64 8 36 N/A N/A N/A 65 65 43 8 N/A 83 8 63 63 59 9 3 6 N/A N/A N/A 60 60 38 3 N/A 78 77 58 58 54 0 6 N/A N/A N/A 55 55 33 N/A N/A 73 7 53 53 49 STANDARD TERMINATION ELEVATION 450-0,000 ft. Pipe Size in. -/ in. 3 in. Input 045 070 090 0 35 045 070 090 0 35 045 070 090 0 35 No. of 90 ELL 7 56 34 N/A N/A 00 00 78 43 N/A 8 7 98 98 94 66 5 9 N/A N/A 95 95 73 38 N/A 3 93 93 89 3 6 46 4 N/A N/A 90 90 68 33 N/A 8 07 88 88 84 4 56 4 9 N/A N/A 85 85 63 8 N/A 3 0 83 83 79 5 5 36 4 N/A N/A 80 80 58 3 N/A 98 97 78 78 74 6 46 3 9 N/A N/A 85 85 53 8 N/A 93 9 73 73 69 7 4 6 4 N/A N/A 70 70 48 3 N/A 98 87 68 68 64 8 36 N/A N/A N/A 65 65 43 8 N/A 93 8 63 63 59 9 3 6 N/A N/A N/A 60 60 38 3 N/A 78 77 58 58 54 0 6 N/A N/A N/A 55 55 33 N/A N/A 73 7 53 53 49 EL96UHV / Page 5

DIMENSIONS - INCHES (MM) - UPFLOW POSITION NOTE - 60C and 60D size units that require second stage air volumes over 800 cfm must have one of the following:. Single side return air with transition, to accommodate 0 x 5 x in. cleanable air filter. Required to maintain proper air velocity.. Single side return air with Optional Return Air Base 3. Bottom return air. 4. Return air from both sides. 5. Bottom and one side return air. See Blower Performance Tables for additional information. Optional Side Return Air Filter Kit is not for use with the Optional Return Air Base. -7/8 (48) D 3-/4 (83) EXHAUST AIR OUTLET SUPPLY AIR OPENING Flue Condensate Trap Assembly Furnished for external field installation on either side of unit. (See installation instructions for additional information.) 7 (78) COMBUSTION AIR INTAKE OPTIONAL SIDE RETURN AIR FILTER KIT (Either Side) 3-3/4 (603) 5 (635) TOP VIEW A B 9/6 (4) -/ (38) Front Panel 7-3/4 (705) 9-7/6 (494) 9/6 (4) OPTIONAL SIDE RETURN AIR FILTER KIT (Either Side) 4-3/4 (375) 6 (406) 33 (838) 6-9/6 (67) Left 9 (9) Right -5/8 (3) (Either Side) ELECTRICAL INLET (Either Side) (5) (Either Side) GAS PIPING INLET (Either Side) CONDENSATE TRAP CONNECTION (Either Side) 6-/ (65) (Either Side) 3 (584) Side Return Air Opening (Either Side) 4 (356) -/ (38) 3/4 (9) Model No. AIR FLOW C Bottom Return Air Opening FRONT VIEW EL96UH045XV36B EL96UH070XV36B EL96UH090XV36C EL96UH090XV48C EL96UH090XV60C EL96UH0XV48C EL96UH0XV60C 3/4 (9) 5/8 (6) 3-/ (597) Bottom Return Air Opening SIDE VIEW A B C D in. mm in. mm in. mm in. mm 7-/ 446 6-3/8 46 6 406 7-5/8 94 533 9-7/8 505 9-/ 495 9-3/8 38 EL96UH35XV60D 4-/ 6 3-3/8 594 3 584 -/8 83 3-/4 (83) -5/6 (49) EL96UHV / Page 6

DIMENSIONS - INCHES (MM) - HORIZONTAL POSITION LEFT-HAND AIR DISCHARGE 6-/ (65) Bottom -5/8 (3) Bottom 6-9/6 (67) Top 9 (9) Bottom CONDENSATE TRAP CONNECTION (Bottom) AIR FLOW ELECTRICAL INLET (Top or Bottom) 7-3/4 (705) 9/6 (4) COMBUSTION AIR INTAKE (5) Top or Bottom TOP VIEW 33 (838) GAS PIPING INLET (Top or Bottom) -/ (38) Front Panel 3/4 (9) 7-3/4 (705) 9/6 (4) 9-7/6 (494) SUPPLY AIR OPENING B D A AIR FLOW 3-/4 (95) A C 3-/ (59) RETURN AIR OPENING EXHAUST AIR OUTLET END VIEW 3-/4 (83) -7/8 (48) FRONT VIEW RIGHT-HAND AIR DISCHARGE END VIEW CONDENSATE TRAP CONNECTION (Bottom) AIR FLOW 6-/ (65) Bottom -5/8 (3) Bottom 9 (9) Top 6-9/6 (67) Bottom (5) Top or Bottom 7-3/4 (705) ELECTRICAL INLET (Top or Bottom) -/ (38) Front Panel TOP VIEW 33 (838) GAS PIPING INLET (Top or Bottom) EXHAUST AIR OUTLET -7/8 (48) 3-/4 (83) 7-3/4 (705) 3-/ (59) RETURN AIR OPENING C 3-/4 (95) A AIR FLOW A D 9-7/6 (494) SUPPLY AIR OPENING B 9/6 (4) END VIEW 3/4 (9) FRONT VIEW COMBUSTION AIR INTAKE END VIEW 9/6 (4) Model No. EL96UH045XV36B EL96UH070XV36B EL96UH090XV36C EL96UH090XV48C EL96UH090XV60C EL96UH0XV48C EL96UH0XV60C A B C D in. mm in. mm in. mm in. mm 7-/ 446 6-3/8 46 6 406 7-5/8 94 533 9-7/8 505 9-/ 495 9-3/8 38 EL96UH35XV60D 4-/ 6 3-3/8 594 3 584 -/8 83 EL96UHV / Page 7

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) HORIZONTAL (END) FILTER KIT 5/8 (6) 4 3/4 (69) -/4 (3) A 5/8 (6) B RETURN AIR OPENING 3 / (597) 5/8 (6) AIR FLOW Furnace Cabinet Width Catalog Number A B in. mm in. mm B 87L96 8 457 6-3/4 45 C 87L97 533 8-3/4 476 D 87L98 5 635 3-3/4 603 5/8 (6) SIDE VIEW AIR FILTER (Furnished) FRONT VIEW CONDENSATE TRAP Optional Return Air Base (Upflow Applications Only - For use with B, C and D cabinets) FURNACE FRONT INDOOR AIR QUALITY CABINET (PCO, Filter Cabinet, etc.) IF BASE IS USED WITHOUT IAQ CABINET, A SINGLE RETURN AIR PLENUM MUST COVER BOTH UNIT AND RETURN AIR BASE OPENINGS 3-/4 (83) 7-/4 (84) 3 (584) Overall (Maximum) Unit side return air Opening 5-5/8 (43) Minimum (79) Maximum 4 (356) SIDE RETURN AIR OPENINGS (Either Side) -7/6 (570) Overall (Maximum) 7-/ (446) B Width (50W98) (533) C Width (50W99) 4-/ (6) D Width (5W00) OPTIONAL RETURN AIR BASE 3 (584) 6-7/8 (683) SIDE VIEW 3/4 (9) NOTE- Optional Side Return Air Filter Kits are not for use with Optional Return Air Base. Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet. Minimum unit side return air opening dimensions for units requiring 800 cfm or more of air (W x H): 3 x in. (584 x 79 mm). The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field. There are cutting guides stenciled on the cabinet for the side return air opening. The size of the opening must not extend beyond the markings on the furnace cabinet. To minimize pressure drop, the largest opening height possible, up to 4 in. (356 mm), is preferred. EL96UHV / Page 8

DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS A 33 (838) B UPFLOW POSITION Uncased Cased Model No (CX34 - cased only) A B A B CX34 C33 in. mm in. mm in. mm in. mm CX34-8/4B-6F C33-4B CX34-8/4C-6F C33-4C 6-/ 49 49-/ 57 3-7/8 35 46-7/8 9 CX34-5B-6F C33-5B 8-/ 470 5-/ 308 5-7/8 403 48-7/8 4 CX34-30B-6F C33-30B CX34-30C-6F C33-30C 0-/ 5 53-/ 359 7-3/4 45 50-3/4 89 CX34-3B-6F C33-3B -/ 57 55-/ 40 0-/4 54 53-/4 353 CX34-36B-6F C33-36B 4-/ 6 57-/ 46-7/8 556 54-7/8 394 CX34-36C-6F C33-36C 4-/ 6 57-/ 46 -/4 540 54-/4 378 CX34-38B-6F C33-38B 4-/ 6 57-/ 46 559 55 397 CX34-4B-6F C33-4B 4-/ 6 57-/ 46-7/8 556 54-7/8 394 CX34-43B-6F C33-43B 7-/ 699 60-/ 537 6-/4 667 59-/4 505 CX34-43C-6F C33-43C 7-/ 699 60-/ 537 5-3/4 654 58-3/4 49 - - - C33-44C 4-/ 6 57-/ 46 -/ 546 54-/ 384 CX34-44/48B-6F C33-48B 4-/ 6 57-/ 46 -/8 56 55-/8 400 CX34-44/48C-6F C33-48C 4-/ 6 57-/ 46 -/ 546 54-/ 384 CX34-49C-6F C33-49C 9-/ 749 6-/ 588 8-/ 74 6-/ 56 CX34-50/60C-6F C33-50/60C 7-/ 699 60-/ 537 4-3/4 69 57-3/4 467 CX43-60D-6F C33-60D 5-/ 648 58-/ 486 4-3/4 69 57-3/4 467 CX34-6C-6F C33-6C 3-/ 800 64-/ 638 30-5/8 778 63-5/8 66 CX34-6D-6F C33-6D 9-/ 749 6-/ 588 8-3/4 730 6-3/4 568 A B 33 (838) HORIZONTAL POSITION CH33-36B-F CH33-36C-F CH33-44/48B-F CH33-50/60C-F Model No. CH33-4B-F CH33-48C-F CH33-60D-F A B in. mm in. mm 6-/ 673 59-/ 5 CH33-6D 3-/ 800 64-/ 638 EL96UHV / Page 9

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) FLUSH-MOUNT VENT TERMINATION KIT 5W (US) or 5W (CANADA) With or -/ in. (5 or 64 mm) PVC pipe Exhaust Intake (Behind Plate) Seal all openings (typical) With 3 in. (76 mm) PVC pipe Exhaust Intake (Behind Plate) -3/8 (60) (305) minimum (recommended) (5) PVC pipe 3 (76) PVC pipe NOTE - PVC pipe and fittings are not furnished When required Use and must be field furnished. Field Provided -/ to in. (64 to 5 mm) Coupling -/ (64) PVC pipe EL96UHV / Page 0

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) CONCENTRIC WALL TERMINATION APPLICATIONS CONCENTRIC ROOF TERMINATION APPLICATIONS EXHAUST AIR OUTSIDE WALL INTAKE AIR EXHAUST AIR (305) Minimum Above Average Snow Accumulation FLASHING (Not Furnished) INTAKE AIR CLAMP (Not Furnished) INTAKE AIR (305) Minimum Above Grade or Average Snow Accumulation CLAMP SHEET METAL STRAP (Clamp and sheet metal strap must be field installed to support the weight of the termination kit.) GRADE ELBOW (Field Supplied) 7M80 / 69M9 / 44W9 inch kits 60L46 / 44W93 3 inch kits See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. A B 3 / (89) in. kits 4 / (4) 3 in. kits TERMINATION ASSEMBLY (Furnished) 6 / (65) INTAKE AIR 6 (5) EXHAUST AIR Outdoor Exhaust Accelerator included with 7M80/44W9 Cat. No. 7M80 69M9 44W9 (Canada) A B in. mm in. mm 33 3/8 848 6 3/4 45 9 737 5 / 394 60L46 38 7/8 987 3/6 538 44W93 (Canada) 36 /8 98 9 / 495 NOTE Typical illustration for dimensions only. Design may vary depending on kit ordered. WALL ASSEMBLY TERMINATION KIT RING KIT 5F74 inch (5 mm) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. DIRECT VENT APPLICATION NON-DIRECT VENT APPLICATION NOTE - EXHAUST PIPE SHOWN Kit Contains Enough Parts For Two Installations in. (305 mm) - in. (5 mm) dia. exhaust pipe 0 in. (508 mm) - 3 in. (76 mm) dia. exhaust pipe maximum length without support in. (305 mm) - in. (5 mm) dia. exhaust pipe 0 in. (508 mm) - 3 in. (76 mm) dia. exhaust pipe maximum length without support 8 in. (03 mm) minimum 6 in. (5 mm) maximum NOTE in. (305 mm) minimum height above average snow accumulation (from bottom of vent pipe). NOTE in. (305 mm) minimum height above average snow accumulation (from bottom of vent pipe). EL96UHV / Page

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE inch (5 mm) G44 (US) 3 inch (76 mm) 44J40 (US) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less than in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL SUPPORT 8 (03) MIN. Between Ends of Exhaust and Intake Pipe (305) MAX. for (5) Dia. Exhaust 0 (508) MAX. for 3 (76) Dia. Exhaust (305) INTAKE AIR 6 (5) Maximum EXHAUST AIR INTAKE AIR 5 (7) / (3) FOAM INSULATION (Field Furnished) EXHAUST AIR 8 (03) MIN. (305) Minimum Above Grade or Average Snow Accumulation GRADE 5-/ (40) (305) Minimum Above Grade or Average Snow Accumulation GRADE (305) MAX. for (5) Dia. Exhaust 0 (508) MAX. for 3 (76) Dia. Exhaust WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE inch (5 mm) 30G8 (WTK Canada) 3 inch (76 mm) 8J0 (WTK Canada) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less than in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL SUPPORT INTAKE AIR 6 (5) Maximum (305) MAX. for (5) Dia. Exhaust 0 (508) MAX. for 3 (76) Dia. Exhaust 6 (5) MIN. EXHAUST AIR INTAKE AIR 5 (7) (305) / (3) FOAM INSULATION (Field Furnished) EXHAUST AIR 6 (5) MIN. (305) Minimum Above Grade or Average Snow Accumulation GRADE (305) MAX. for (5) Dia. Exhaust 0 (508) MAX. for 3 (76) Dia. Exhaust 5-/ (40) (305) Minimum Above Grade or Average Snow Accumulation GRADE EL96UHV / Page

BLOWER DATA EL96UH045XV36B BLOWER PERFORMANCE (less filter) BOTTOM RETURN AIR 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. () External Static Pressure Range Heating First Stage Heating - cfm HEATING Second Stage Heating - cfm +4% 95 5 +8% 865 085 +% 805 040 +6% 780 985 Factory Default 740 95 6% 665 875 % 630 800 8% 585 735 First Stage - cfm COOLING Second Stage - cfm Low Medium-Low Medium- Low Medium-Low Medium- + 595 760 865 980 905 075 0 370 Factory Default 540 660 785 890 85 980 0 55 485 600 695 790 70 885 00 35 and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 38%, 70% and 00% of the selected second stage cooling speed - minimum 50 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 50 cfm. EL96UH045XV36B BLOWER MOTOR WATTS (COOLING) + Setting Factory Default Setting First Stage Motor Watts @ Various External Static Pressures - in. wg. Second Stage 0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 0.9.0 Low 8 33 54 73 88 07 4 44 58 64 87 40 7 96 5 43 67 97 37 Med-low 36 58 8 00 0 4 66 8 7 38 85 4 37 7 96 36 348 369 390 Med- 57 86 03 8 59 87 0 33 55 89 9 50 80 305 340 377 4 439 464 483 9 4 4 77 7 35 59 85 3 67 8 3 363 400 433 468 50 5 55 549 Low 6 34 5 67 86 98 0 38 55 46 69 9 5 4 67 88 06 3 60 80 Med-low 5 35 65 85 0 5 40 55 80 93 0 38 73 09 30 55 80 304 35 343 Med- 4 66 87 06 9 54 78 95 3 50 66 06 38 64 93 30 349 376 399 40 6 87 0 38 69 94 4 65 3 45 69 300 334 368 399 43 460 480 53 Low 0 8 40 56 76 89 06 37 33 5 78 97 6 3 59 74 0 4 38 Med-low 8 34 55 73 89 08 4 45 59 59 86 04 9 60 87 34 56 8 303 Med- 9 45 7 9 4 9 5 66 93 07 57 88 47 73 30 34 343 36 44 67 89 35 60 83 00 7 60 85 4 46 77 30 335 364 39 44 435 EL96UHV / Page 3