GFK-210-C Blower System - Installation and Operating Instructions -

Similar documents
Fan, DVI Insert 31 and 33 DVI Installation Instructions (sku )

SERVICE MANUAL Model: SF-INS30-BK - Instructions -

Wolverine Turn Signal / Horn Kit 2102

Installation Instructions

Electric. PN April Series Electric Oven

AquaPure Ei TM Series Replacement Kits

INSTALLATION INSTRUCTIONS

XS400 Load Bank. Read all instructions before using the load bank. Contents

INSTALLATION INSTRUCTIONS

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

OUT FRONT ELECTRIC HYDRAULIC (W/E-47H) FOR STRAIGHT TRIPEDGE PLOWS (PULL AWAY MOUNTINGS)

Grind Pro Series. Operator Manual. Manufacture by:

Installation Instructions

OWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.

INSTALLATION INSTRUCTIONS FORD SUPER DUTY NOTE: (Vehicle Retains Tow Hook) PART # P3064

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Legacy Combustion Chamber Replacement Kit

Installation Instructions

Electric Range installation manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Installation Instructions

Change the and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat

564 Shadowbox Face (w Screen) Instructions

AUTOMATIC FOODSERVICE EQUIPMENT. AUTOMATIC ELECTRIC BROILER MODELS 952E, 932E and 922E OWNER S MANUAL

Accessory Fuse Block. Please read this entire manual before proceeding with installation.

Installation Instructions

Multiplexing system installation M

Record the serial number and date of purchase in your manual for future reference.

Q35 Series Automatic Vent Damper System

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree

TOYOTA FJ CRUISER 2007 AUXILIARY LIGHTS Preparation

Owner s Information Manual

Installation Instructions

Technical Information and Diagnostic Guide

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Operations and Service Manual. X30208 Load Bank

Part number list on following page. 08/18

Troubleshooting Electronic Ignition

FOR INDOOR/SEASONAL USE ONLY

CAUTION WARNING WARNING PROFLAME 2 UPGRADE KIT RX RX 300 NG/LP. Installation & Maintenance Manual

INSTALLATION INSTRUCTIONS

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

AUTOMATIC FOODSERVICE EQUIPMENT. AUTOMATIC ELECTRIC BROILER MODELS 824E & 850E and 624E & 650E. B-Series Broiler OWNER S MANUAL

X100P Load Bank. Read all instructions before using the load bank. Contents

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

97-02 JEEP TJ BODY LIFT KIT INSTRUCTIONS

Non-qualifi ed users should never open or remove covers, as this will expose dangerous voltage points and other serious risks.

"Engineered to Ride, Built to Last "

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

MODEL SCA Installation and Operation Manual Important:

TOYOTA PRIUS FOG LIGHT (Halogen or LED)


16" STAND FAN WITH REMOTE

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

Operations and Service Manual. XE400D-SB Load Bank

Portable Air Purifiers

Installation Instructions Electric Heaters 5 20 kw

P3066 INSTALLATION MANUAL

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

High Velocity Series Air Curtains

Installation Instructions

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

Troubleshooting Manual

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS

Model 579 Curtain Machine Manual. General Information. Unpacking:

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

HAND THROTTLE KIT For Workman 3000 Series

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

HLS Watt Halogen Illuminator Service Manual

ELECTRONIC FIREPLACE DAMPER

GENUINE PARTS INSTALLATION INSTRUCTIONS

Environmental Series Air Curtains

MC2500. Installation and Operation Manual

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

PARTS CATALOG PROHEAT X30

Troubleshooting Guide

Part Number: T4R-2N1. Hardware Bag Contents. General Applicability Models with factory fog light. Conflicts -


TOYOTA COROLLA L, LE FOG LIGHT (Halogen and LED) Part Number: TCO-314 / TCO-814

NIDAC EMC Communicating Motor

3 in 1 TRAIL CHARGER with LOCKOUT

LGT-312L E-Z-Go TXT Light Bar Bumper Kit Installation Instructions

Pro Island Ventilation Hoods


INSTALLATION GUIDE. Greentek. Residential use only MODEL HS 3.0

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Assembly Instructions

Power and Cooling. Chassis Power System

Poly Electric Drinkers

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

Spreader and Vehicle Battery Kits

Part Number: SFR-713. Hardware Bag Contents. General Applicability All models. Conflicts - Fog Lights. Date: SCION FRS LED DRL

7.5' LED Silver Glitter with Pinecones One Plug Tree V INSTRUCTION MANUAL

Transcription:

GFK-210-C Blower System - Installation and Operating Instructions - 1.0 INTRODUCTION The GFK-210-C Blower System has been designed to circulate room air through the fi replace to enhance heat output. The GFK-210-C blower system operates on 120 VAC, 60 Hz power. This is available through a receptacle in the factory installed power cord assembly. The power cord is located in the controls compartment of the fireplace. An optional variable speed control is available for use with the blower system to provide quiet forced air fl ow at the desired speeds. A temperature sensor switch, which automatically turns the blower ON/OFF, is also provided with this kit. See Figure 2 and Section 8.0. NOTICE: The variable speed control and temperature sensor switch are not used with some remote control systems. CAUTION! Do not install a damaged blower kit. ASSEMBLIES (2) 2.0 CHECK CONTENTS OF SHIPPING CARTON Compare CONTENTS OF CARTON in Figure 1 with the actual parts received. If any parts are missing or damaged, contact your dealer before starting installation. 3.0 INSTALLATION PRECAUTIONS The GFK-210-C Blower Kit is tested and safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and to follow these instructions carefully during installation to assure maximum benefit from, and safe operation of, the blower. This blower is carefully engineered and must be installed only as specifi ed. If you modify it or any of its components, you may cause a fire hazard and will void the WARRANTY. In addition, such action may void the coverage provided by the owner's home insurance. CAUTION: All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes and with the National Electric Code ANSI/NFPA NO. 70-current (in the United States), or with the current CSA C22.1 Canadian Electric Code (in Canada). CAUTION! DO NOT connect 110-120 VAC wiring to the gas control valve of the fi replace. WARNING! Risk of Shock! Turn electrical power off at the circuit breaker before beginning this installation. (2) CORD (1) OPTIONAL RHEOSTAT/ SENSOR SENSOR SWITCH WING NUT SCREWS (4) FAN BRACKETS (2) NOT SHOWN: INSTRUCTIONS ZIP TIES (2) KNOB NUT VARIABLE SPEED Figure 1. Carton Contents - GFK-210-C Figure 2. Carton Contents - SRV2206-800 1

4.0 INSTALLING THE (Metal Inserts) 1. Remove factory-installed blower brackets by removing four screws. Brackets are only used for the FireBrick inserts. See Figure 3. 2. Remove appliance from wall. 3. Remove access panel by removing screws. See Figure 4. Note: 35 inch models have two more screws than 30 inch models. 4. Screw blowers to access panel on rear of insert with four screws. See Figure 5. 5. Plug the blower cord into the blower receptacle. Connect the white, black, and green spade connectors from blower cord harness to each blower. See Figure 1 and Figure 7. 6. Bundle and zip tie any wires to keep them from contacting the fan blades. See Figure 7, Detail A. 7. Reinstall access panel. NOTE: Install the blower using the access panel located on the back side of the appliance. Figure 4. Remove Access Cover 35 INCH MODELS ONLY BRACKET HOLES Figure 3. Remove Blower Brackets Figure 5. Attach Blowers to Access Cover 2

5.0 INSTALLING THE OPTIONAL VARIABLE SPEED AND SENSOR SWITCH If using a remote control system that utilizes a blower (fan) control, disregard steps 1-3 and follow remote control installation instructions. NOTICE! The sensor switch and rheostat are not used if the blower is controlled with the RC300 remote control. 1. Slide the variable speed control behind the control panel. With the stem sticking out of the pre-punched hole, attach the locknut tightly and reattach the knob on the stem. See Figure 6. Turn the speed control switch to the "ON" position. 2. Slide the temperature sensor switch onto the blower stud located on the bottom of the combustion box. See Figure 3. Secure the temperature sensor switch with the wing nut provided. NOTICE: The blower stud is located on the bottom of the combustion box. See Figure 6. NOTICE: The temperature sensor switch must be installed so that the sensor switch is facing the combustion box surface. See Detail A of Figure 6. 3. Connect the variable speed control and the temperature sensor switch to the power cord. See Figure 7. 4. Gather the loose wires underneath the appliance and use the zip ties to restrain them and keep them away from the blower wheel (fan blades). See Figure 7, Detail A. 5. Turn the 110-120 VAC service "ON" at the circuit breaker. 6.0 RECOMMENDED OPERATING PROCE- DURES WHEN VARIABLE SPEED AND SENSOR SWITCH ARE USED Ignite the fire in the fireplace with the variable speed control switch in an "ON" position. The fan will automatically turn on when the temperature sensor switch closes at approximately 110 O F. Heated air will be delivered at the outlet grille. The fan will continue to operate after the fi replace is turned OFF until the temperature sensor switch opens. NOTICE! During operation, ensure that all wiring is kept away from the blower wheel (fan blades). Various conditions (such as fi replace model, type of fi replace installation, outside air temperature vs. inside air temperature) can contribute to the length of the time the blower remains on after the fi replace is turned OFF. The blower can be turned off manually with the speed control switch. WARNING! Risk of Injury! DO NOT contact the blower wheel (fan blades) during operation. 7.0 MAINTENANCE Periodically check the fi replace and remove any dust, dirt or obstructions. 8.0 REPLACEMENT PARTS AND CUSTOMER SERVICE Replacement parts and service may be obtained through your dealer. Rheostat/Temperature Sensor Assembly: SRV2206-800 VARIABLE SPEED SENSOR SWITCH STUD DETAIL A COMBUSTION BOX SURFACE Figure 6. STUD SENSOR SWITCH 3

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 0 C RATED WIRE. DETAIL A POWER CORD PLUG 120V EXISTING OUTLET DETAIL A BRN BLACK RED CORD TO VALVE BRACKET (GROUND) SENSOR SWITCH ORG TO VALVE VARIABLE SPEED (RHEOSTAT) PANEL ZIP TIES PLUG INTO 120V EXISTING OUTLET POWER CORD VARIABLE SPEED DC REGULATOR RECEPTACLE SENSOR SWITCH RECEPTACLE CORD S Figure 7. Fan Wiring Diagram - Metal Insert Without RC200/RC300 4

9.0 Fan Wiring with Remote This appliance may be used with an RC200 or RC300 remote control. See Figure 8. 1. Remove cord assembly spades from rheostat and sensor switch. NOTICE: Fan speed and operation are controlled by the remote control. The sensor switch and rheostat are no longer needed. 2. Plug two cord assembly spade connectors together. 3. Unplug fan cord assembly from standard cord assembly. 4. Install fuse wire assembly in series between the black lead wires of the fan cord and black lead wire on each blower. See Figure 8. 5. Plug fan cord assembly into AUX300 module. 6. Plug AUX300 module into the standard cord assembly. NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 0 C RATED WIRE. PLUG 120V EXISTING OUTLET STEP 5 NOTE: USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE APPLIANCE AND KEEP THEM AWAY FROM THE WHEEL (FAN BLADES). STEPS 3 & 5 STEPS 1 & 2 SENSOR SWITCH (2) (2) (2) (2) (2) (2) SPEED (RHEOSTAT) NOTE: SENSOR SWITCH AND RHEOSTAT SPEED MUST BE REMOVED FROM CIRCUIT IF SYSTEM IS LED WITH RC200/300 REMOTE. PLUG INTO 120V EXISTING OUTLET DC REGULATOR RECEPTICLE TO MODULE RECEPTICLE AUX 300 MODULE FAN S Figure 8. Fan Wiring Diagram - Metal Insert with RC200/RC300 Remote 5

10.0 INSTALLING THE (FireBrick Inserts) For Models: ESCAPE-I30FB, ESCAPE-I35FB, QFI30FB, QFI35FB The factory installed brackets must be replaced with the brackets included in the instruction bag before proceeding with blower installation instructions below. See Figure 9. For Models: ESCAPE-I30-C, ESCAPE-I35-C, QFI30FB-C, QFI35FB-C Proceed as follows: 1. Remove appliance from wall. 2. Disconnect power by shutting off circuit breaker or unplugging appliance power cord from its receptacle. 3. Remove access panel from lower rear of the fi replace insert. See Figure 10. 4. Connect white and green wires from blower wire assembly to each blower. See Figure 12. Connect the fuse wire assembly in series between black wires of blower wire assembly and each blower. See Figure 12. 5. Route blower plug assembly through back of appliance to right side of appliance. Ensure cable assembly is routed in front of fan blade guard and through plastic bushing on auxiliary mounting plate. 6. Insert plug from blower cable assembly into AUX300 receptacle. See Figure 12. 7. Position the right and left blower assembly into the rear opening. Fasten each assembly with two sheetmetal screws. Take care to ensure that blower housing or its motor is clear of any adjacent metal. This will ensure that no undue noise occurs during blower operation. 8. Bundle and zip tie loose wires to keep them from contacting blower impeller blades 9. Reinstall access panel. 10. Reconnect power to the insert and install into wall. SCREWS Figure 9. Attach Brackets Figure 10. Remove Access Panel BRACKETS (INCLUDED IN INSTRUCTION BAG) SCREWS ACCESS PANEL Figure 11. Attach Blower to Base 6

Note: if any of the original wire as supplied with the appliance must be replaced, it must be replaced with type 105 C rated wire. Note: use zip ties to restrain the loose wires underneath the appliance and keep them away from the blower wheel (fan blades). S PLUG INTO 120V EXISTING OUTLET ORANGE - TO VALVE GROUND - TO VALVE BRACKET GREEN - TO VALVE BRN RED PLUG INTO EXISTING OUTLET TO IPI MODULE S Figure 12. Fan Wiring Diagram - FireBrick Inserts Please contact your Hearth & Home Technologies dealer with any questions or concerns. For the location of your nearest Hearth & Home Technologies dealer, please visit www.hearthnhome.com. Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 55044 www.hearthnhome.com 7