Ducted Split System Air Conditioners

Similar documents
Ducted Split System Air Conditioners

Air Cooled Packaged Units

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

ISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS

Air Cooled Packaged Units Technical Data

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

OUTDOOR UNIT CONTROLLER (OUC)

Hitachi Inverter Wall Split Air Conditioning

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

TRI-CAPACITY PACKAGE UNIT

Hitachi Inverter Wall Split Air Conditioning

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

Hitachi Inverter Wall Split Air Conditioning

(click on page links below) XAL-2C Technical Data 1. XAL-4C Technical Data 3

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

Landmark Rooftop Packaged Units

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.

DC INVERTER DUCTED AIR CONDITIONERS

D M S 760 C01 A A 1 1

AHN 064 to 304 EHN/CHN 064 to 304

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

IDENTIFICATION ACCESSORIES DESCRIPTION

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

RCD Air Cooled Condensing Unit (50/60 Hz)

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

INVERTER DUCTED SYSTEMS

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

The World Leading Air-conditioning Company

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

DESCRIPTION FEATURES

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Concealed Ducted Split Series R22

HITACHI Utopia Premium Inverter Air Conditioning

CWP-CO / CWP-RC / CWP-HP 02 to 35

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

N4A6. Product Specifications

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

DS4BD-KB Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

TECHNICAL SPECIFICATIONS

technical catalogue tetris KW Chiller and heat pumps air/water

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

modular multi intelligent, environmental and versatile

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

Hi-Wall Inverter Split System. Efficient, effective and comfortable cooling and heating where you need it

WQL/WQH/WQRC 524 to 1204

CXAM. Options. Accessories

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

PREMIUM INVERTER DUCTED AIR CONDITIONING

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

HCH6. Product Specifications

R-22, 13 SEER 60 Hertz

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

PACKAGE AIR CONDITIONERS

UMXCA/UMXCBA ECVA/ECVBA

Q7RE Series Single Packaged Heat Pump, Single Phase

VT4BF-KA/B Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton Capacity

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

Hi-Wall Inverter Split System. Cooling and heating, exactly where and when you need it

The ActronAir range of air conditioners provides a solution for most applications.

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Highline 260i EC Waterside Fan Coil Unit

Tons BTU/h S.E.E.R* E.E.R** HSPF

VARIABLE CAPACITY COMMERCIAL SERIES Premium performance, flexible controls.

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

Transcription:

Technical Data ISD 116, ISD 141, ISD 164, ISD 184, ISD 194, ISD 224 Cooling Capacity 11.4kW - 22.4kW Heating Capacity 10.8kW - 21.6kW

Contents ISD 116 224 KYX SERIES 3 General 3 Applications 4 Air Flow Selection 4 Features 4 Refrigerant R410A 4 User Friendly 4 Economy 4 Efficient 4 Performance 4 Separable 5 Quiet 5 Slimline 5 Durable 5 Insulation 5 Control Option 5 Self Diagnostics 5 Zone Control 5 Optional Equipment 6 Safety Features 6 Compressor 6 Refrigeration Piping 6 Wiring 6 SAT-3 CONTROLLER (Optional) 7 Features Summary 7 PERFORMANCE DATA 8 Cooling Capacity (kw) 8 Heating Capacity (kw) 9 Indoor Air Flow Correction Factors 9 Air Handling 10 Sound Levels 11 Indoor Unit 11 Outdoor Unit 12 DIMENSIONS (mm) 13 ISD Indoor Unit 13 OSA Outdoor Unit 14 SPECIFICATIONS 15 Page 2 of 16

ISD 116-224 KYX series The ISD indoor units, together with their associated OSA outdoor units, provide a reverse cycle (heat pump) split system air conditioner designed and developed to comply with and exceed AS/NZS 3823. Each system has been successfully tested at 52 C ambient. Page 3 of 16

ISD 116-224 KYX series Applications These units have been specifically developed for air conditioning of light commercial and residential premises, e.g. offices, motels shops and homes. Suitable for applications using full or high proportions of fresh air (nb pre-heating on heating cycle may be required). Also suitable for VAV, close control and supply air temperature control. AIR FLOW SELECTION If the air returning to the indoor coil is regularly expected to be above 50%RH, then the coil face velocity should be limited to be 2.5 m/s or less. High humidity levels can occur in tropical or subtropical conditions, and/or when heavily moisture laden fresh air is introduced. Consideration must always be given to selecting an air flow and face velocity that avoids water carry-over problems. Applications using full or high proportions of fresh air should be referred to your nearest temperzone sales office to establish the correct selection of units. FEATURES Refrigerant R410A Each complete system uses refrigerant R410A which has a zero ozone depletion potential. User Friendly The air conditioning system is available with an optional SAT-3 Controller or TZT-100 Controller which is wired to the Indoor or Outdoor unit. These thermostats have been designed to maintain a high level of comfort for room occupants. Emphasis has been placed on providing controls that are easy to use despite the sophisticated microprocessor system that runs it. Use of the Auto and Timer function settings allows you to set it and forget it. Economy Each ISD/OSA system has a variable capacity compressor which uses less energy than alternative types of compressor. Efficient Indoor units include a high efficiency electronically commutated (EC) motor. Part load operation at low loads (75% airflow equates to 55% power use) using temperzone algorithms. Each outdoor unit incorporates a high efficiency compressor. Heat exchange coils use inner grooved (rifled) tube for better heat transfer. Performance The variable capacity compressor technology can provide close comfort control of the room temperature. The OSA 184F and 224F have an extra boost capacity available for fast response when well away from set point at start-up. A dynamically balanced forward curved fan with a multi-speed EC motor enables fine tuning of the indoor unit to match the supply air requirements. These EC motor fans have a fully integrated speed control that enables soft starting. Fan speed can be stepped to your own requirements or continuously variable using a 0 10V DC control signal. The system includes a temperature sensing Page 4 of 16

ISD 116-224 KYX series head pressure control which enables the system to compensate for outdoor ambient temperatures below 20 C on cooling cycle, and above 15 C on heating cycle. Separable The indoor units are separable for ease of installation through small man holes minimum 550 mm sq. clear aperture. It may be desirable in some applications to keep the two separate parts of the unit apart and joined by ducting, eg over a ceiling joist. A pair of the optional Spigot Plate Adaptors are available to facilitate this option. Quiet Each integral high efficiency EC motor can vary from zero to full speed. This allows slow ramp up with no sudden noise change. The motor can be controlled to have the best air flow for the ducting and requirements as well as used for de-humidifying the space. The outdoor units coil design permits low fan speeds and hence low noise levels. The compressor is isolated in a built-in, insulated compartment to minimise noise. The indoor unit is also insulated for noise attenuation. Slimline The compact up-right design of the outdoor units requires only a 150 mm gap on the coil side where installation is against a wall. Their slimline cabinets are particularly practical where there is restricted space, e.g. side access pathways, balconies, narrow ledges, etc. The unit is free standing, but can be fitted on a wall using the optional wall mounting brackets. Durable Both indoor and outdoor coil fins are epoxy coated for extra protection in corrosive environments, e.g. salt laden sea air. Each outdoor unit s cabinet is constructed from high grade galvanised steel - polyester powder coated (grey) for all weather protection (IP 44). External fasteners are stainless steel. Heat exchange coils comprise aluminium corrugated plate fins on mechanically expanded rifled copper tube. Each indoor unit s cabinet is constructed from high grade galvanised steel and includes a plastic drain tray for complete corrosion resistance and a galvanised steel safety drain tray. Outdoor coils are protected with louvred anti-hail guards. Soft Starting EC motors are soft starting therefore have none of the problems associated with high in rush current. Insulation Closed cell foam insulation has been used in the indoor units cabinet to ensure no particles are introduced into the air stream. The insulation is foil faced and meets fire test standards AS 1530.3 (1989) and BS 476 parts 6 & 7. Control Option Commissioning is made easier when the EC motor to be controlled variably (within a restricted range) by a 0 10 volt DC signal that can be supplied either by a BMS system, a sophisticated controller or temperzone s optional TZT-100 Controller. The systems UC8 controller is BMS compatible with multi-unit control possible either via digital and analogue signals or via Modbus. Refer to temperzone for other protrocols available. Self Diagnostics The Outdoor Unit Controller (UC8) has a LED display to indicate faults and running conditions. A non-specific fault indicator is included for interface to external systems via the optional relay board. Zone Control ISD-KYX versions using SAT-3 controller can be fitted with the optional Zone Control kit which allows up to 6 zone dampers to be switched from the SAT-3 wall control. Standard damper motors, 24 volt ac, can be used with drive open/drive close. Page 5 of 16

ISD 116-224 KYX series OPTIONAL EQUIPMENT Outdoor Unit: 1. Wall mounting brackets. 2. Anti-vibration mounts (rubber) 3. Drain connection - right angle 4. Fault relay board (201-000-105) 5. Soft Starter for lowering starting current (OSA 116/141 only). Indoor Unit: 1. temperzone SAT-3 Controller or TZT-100 Controller. 2. Six Zone Control kit for SAT-3. 3. Spring mounting kit. 4. Supply & return air spigots (available in New Zealand only) 5. Spigot Plate Adaptors Double Inlet (for use when separating indoor unit) 6. Filter Box c/w EU2/G2 rated filter. SAFETY FEATURES 1. HP and loss of refrigerant protection. 2. Anti-rapid cycle timer and internal overload for compressor protection. 3. Circuit breaker control circuits. 4. Time-and-temperature controlled electronic de-ice switch prevents icing up of the outdoor coil during heating cycle. 5. Frost protection on cooling cycle. 6. Sensor fault indication. REFRIGERATION PIPING Maximum line length is 60m. Max. height separations between units are: Outdoor unit above indoor unit: 20m Outdoor unit below indoor unit: 20m. Each OSA unit is shipped from the factory with a charge of HFC-410A (R410A) refrigerant sufficient for a 10m line length. Liquid and suction service valves are provided. The matched indoor unit is shipped with a holding charge of nitrogen. Both units have brazed pipe connections. WIRING The electrical supply required (including voltage fluctuation limits) is: OSA 116/141RKS: 1 phase 220 240 V a.c. 50 Hz with neutral and earth. OSA 141/164/184/194/224 RKT: 3 phase 380 415 V a.c. 50 Hz with neutral and earth. A control panel, located in each outdoor unit, is fully wired ready to accept the main power supply. Each system complies with the requirements of the Regulatory Compliance Mark (RCM) for electrical safety (AS/NZS 60335.2.40) and EMC (AS/NZS CISPR.14). Provision has been made for compliance with DRED, ie demand response enabling device standard AS/NZS 4755.3.1. 7. Compressor minimum run time to ensure oil return. 8. 12V control circuit. COMPRESSOR Each high efficiency variable capacity compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration. Digital compressors have proven very reliable because of their design simplicity; electrical harmonic noise is very low. Page 6 of 16

SAT-3 Controller (Optional) Open Closed FEATURES SUMMARY Cool / Dry / Fan modes. Heat / Auto modes Auto / High / Medium / Low fan speed selection (customisable). Temperature setting range from 16 C 30 C. Room temperature display. Real time clock. 7 day timer up to four start and/or stops per day Override countdown run timer, up to 4 hours.. Continuous or Intermittent selection of fan run-on in dead zone. Backlit screen for ease of reading; changes colour for each mode. Soft touch tab keys Battery backup (Lithium). Sleep function improves night time comfort and saves energy. Eco mode for ecomical operation. Quiet mode for outdoor unit. Low voltage control cable. Connects to either indoor unit or outdoor unit. Colour: white and light grey. Optional: 1. Remote return air sensor 2. Six Zone Control kit Note: Not backwards compatible with units using SAT-2. TZT-100: Refer www.temperzone.biz for information. Page 7 of 16

Performance Data COOLING CAPACITY (KW) Total = Total Capacity (kw). Sens. = Sensible Capacity (kw). E.A.T. = Entering Air Temperature. = Nominal Capacity (kw). Refer page 9 for Indoor Air Flow Correction factors Note: Capacities are gross and do not include allowance for fan motor heat loss. Capacities are for close coupled systems. Interconnecting pipework will reduce capacity. Models Indoor Unit Outdoor Unit ISD 116 OSA 116G ISD 141 OSA 141G ISD 164 OSA 164G ISD 184 OSA 184F ISD 194 OSA 194G ISD 224 OSA 224F ISD 224 OSA 224G Indoor Fan Speed Air l/s High 630 High 830 High 910 High 980 High 1065 High 1190 High 1190 Indoor coil E.A.T. D.B. C W.B. C Outdoor coil entering air temperature C D.B. 23 27 31 35 39 43 Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. 21 15 11.2 8.6 11.1 8.6 10.7 8.4 10.2 8.1 9.6 7.7 8.7 7.1 23 17 11.8 8.4 11.7 8.4 11.4 8.3 10.8 8.0 10.2 7.6 9.3 7.1 27 19 12.4 9.7 12.2 9.7 12.0 9.5 11.4 9.2 10.8 8.8 9.9 8.2 31 21 13.0 11.4 12.9 11.4 12.5 11.3 12.1 10.9 11.4 10.5 10.5 9.8 21 15 13.5 11.1 13.3 11.1 12.9 10.9 12.3 10.5 11.5 10.0 10.5 9.2 23 17 14.2 10.9 14.0 10.9 13.7 10.7 13.0 10.3 12.2 9.8 11.2 9.1 27 19 14.9 12.5 14.7 12.5 14.4 12.3 13.7 11.9 12.9 11.3 11.9 10.6 31 21 15.6 14.7 15.5 14.7 15.1 14.6 14.5 14.1 13.7 13.5 12.7 12.7 21 15 16.2 12.7 16.0 12.7 15.5 12.4 14.8 12.0 13.8 11.4 12.6 10.5 23 17 17.0 12.4 16.8 12.4 16.4 12.2 15.6 11.8 14.7 11.2 13.4 10.4 27 19 17.9 14.3 17.7 14.2 17.2 14.0 16.4 13.6 15.5 12.9 14.3 12.1 31 21 18.8 16.8 18.6 16.8 18.1 16.6 17.4 16.1 16.4 15.4 15.2 14.4 21 15 18.2 14.0 18.0 14.0 17.4 13.7 16.6 13.3 15.5 12.6 14.2 11.6 23 17 19.2 13.7 18.9 13.7 18.5 13.5 17.6 13.0 16.5 12.4 15.1 11.5 27 19 20.1 15.8 19.9 15.7 19.4 15.5 18.5 15.1 17.5 14.3 16.1 13.4 31 21 21.2 18.6 20.9 18.6 20.4 18.4 19.6 17.8 18.5 17.1 17.1 16.0 21 15 19.0 15.1 18.7 15.1 18.1 14.8 17.3 14.3 16.2 13.5 14.7 12.4 23 17 19.9 14.8 19.7 14.8 19.2 14.5 18.3 14.0 17.2 13.4 15.7 12.4 27 19 20.9 17.0 20.7 16.9 20.2 16.7 19.2 16.2 18.2 15.4 16.7 14.4 31 21 22.0 20.0 21.8 20.0 21.2 19.7 20.4 19.2 19.2 18.3 17.8 17.2 21 15 21.0 16.6 20.7 16.6 20.0 16.2 19.1 15.7 17.9 14.9 16.3 13.7 23 17 22.0 16.2 21.8 16.2 21.2 16.0 20.2 15.4 19.0 14.7 17.4 13.6 27 19 23.1 18.7 22.9 18.6 22.3 18.3 21.2 17.8 20.1 16.9 18.5 15.8 31 21 24.3 22.0 22.0 22.7 23.4 21.7 22.5 21.1 21.2 20.2 19.7 18.9 21 15 21.8 16.8 21.5 16.8 20.9 16.5 19.9 15.9 18.6 15.1 17.0 13.9 23 17 23.0 16.5 22.7 16.5 22.1 16.2 21.1 15.6 19.8 14.9 18.1 13.8 27 19 24.1 18.9 23.8 18.9 22.2 18.6 22.1 18.0 21.0 17.1 19.3 16.0 31 21 25.3 22.3 25.0 22.3 24.4 22.0 23.4 21.4 22.1 20.4 20.5 19.2 Page 8 of 16

Performance Data HEATING CAPACITY (KW) G N = Gross Heating Capacity kw, based on nominal air flow. = Net Heating Capacity kw allowing for average defrost. = Nominal Capacity (kw). Models Indoor Entering Air Temp. C Outdoor coil entering air temperature C D.B. Indoor Unit Outdoor Unit D.B. -5-3 -1 1 3 5 7 9 G N. G N. G N. G N. G N. G N. G N. G N. ISD 116 OSA 116G ISD 141 OSA 141G ISD 164 OSA 164G ISD 184 OSA 184F ISD 194 OSA 194G ISD 224 OSA 224F ISD 224 OSA 224G 15 8.1 7.6 8.6 7.6 9.0 7.7 9.5 8.1 10.0 9.1 10.4 10.4 10.9 10.9 11.3 11.3 20 8.0 7.5 8.5 7.5 8.9 7.6 9.4 8.0 9.8 9.0 10.3 10.3 10.8 10.8 11.2 11.2 25 7.7 7.3 8.2 7.3 8.7 7.4 9.1 7.8 9.6 8.8 10.0 10.0 10.5 10.5 11.0 11.0 15 9.5 8.9 10.0 8.8 10.6 9.0 11.1 9.5 11.6 10.6 12.2 12.2 12.7 12.7 13.3 13.3 20 9.3 8.8 9.9 8.7 10.4 8.9 11.0 9.4 11.5 10.5 12.1 12.1 12.6 12.6 13.1 13.1 25 9.0 8.6 9.6 8.5 10.1 8.6 10.7 9.2 11.2 10.3 11.8 11.8 12.3 12.3 12.8 12.8 15 11.3 10.6 11.9 10.5 12.6 10.7 13.2 11.3 13.9 12.7 14.5 14.5 15.1 15.1 15.8 15.8 20 11.1 10.5 11.8 10.4 12.4 10.5 13.0 11.2 13.7 12.5 14.3 14.3 15.0 15.0 15.6 15.6 25 10.8 10.2 11.4 10.1 12.0 10.2 12.7 10.9 13.3 12.2 14.0 14.0 14.6 14.6 15.3 15.3 15 14.1 13.3 14.9 13.2 15.7 13.3 16.5 14.2 17.3 15.8 18.1 18.1 19.0 19.0 19.8 19.8 20 13.9 13.1 14.7 13.0 15.5 13.2 16.3 14.0 17.1 15.7 17.9 17.9 18.7 18.7 19.5 19.5 25 13.5 12.8 14.3 12.6 15.1 12.8 15.9 13.6 16.7 15.3 17.5 17.5 18.3 18.3 19.1 19.1 15 12.7 12.0 13.4 11.8 14.1 12.0 14.9 12.7 15.6 14.2 16.3 16.3 17.0 17.0 17.8 17.8 20 12.5 11.8 13.2 11.7 13.9 11.8 14.7 12.6 15.4 14.1 16.1 16.1 16.8 16.8 17.6 17.6 25 12.1 11.5 12.8 11.4 13.5 11.5 14.3 12.3 15.0 13.8 15.7 15.7 16.4 16.4 17.2 17.2 15 17.4 16.4 18.3 16.2 19.3 16.4 20.3 17.4 21.3 19.5 22.3 22.3 23.3 23.3 24.3 24.3 20 17.1 16.2 18.1 16.0 19.1 16.2 20.1 17.2 21.1 19.3 22.1 22.1 23.0 23.0 23.5 23.5 25 16.5 15.7 17.5 15.5 18.5 15.8 19.5 16.8 20.5 18.8 21.5 21.5 22.5 22.5 23.5 23.5 15 16.3 15.3 17.2 15.1 18.1 15.4 19.0 16.3 20.0 18.2 20.9 20.9 21.8 21.8 22.7 22.7 20 16.0 15.1 16.9 15.0 17.9 15.2 18.8 16.1 19.7 18.0 20.6 20.6 21.6 21.6 22.5 22.5 25 15.5 14.7 16.4 14.5 17.4 14.8 18.3 15.7 19.2 17.6 20.1 20.1 21.1 21.0 22.0 22.0 INDOOR AIR FLOW CORRECTION FACTORS @ NOMINAL CONDITIONS Indoor Air Flow (%) -20-10. Rated +10 Total Capacity 0.95 0.975 1.0 1.025 Sensible Capacity 0.89 0.950 1.0 1.050 Page 9 of 16

Performance Data AIR HANDLING Airflows are for a dry coil. Reduce airflow by 10% in high moisture removal conditions. In a free blow application, beware of exceeding indoor fan motor s full load amp limit. Refer back page for filter losses. Air flows given are for ISD units without filter installed. ISD 116KYX AVAILABLE EXTERNAL PRESSURE (Pa) 250 200 150 100 0.6A 50 l/s - Pa 1.7A 1.2A 0.9A 0.9A ISD 164KYX AVAILABLE EXTERNAL PRESSURE (Pa) 250 200 150 100 ISD 194KYX AVAILABLE EXTERNAL PRESSURE (Pa) 4V 5V 2.4A 4V - - - - l/s - W 1000 9V 800 600 7V 400 3.5A 200 1.2A 0 1.0A 1.9A 300 400 500 600 700 800 AIR VOLUME (l/s) Nominal 2.5 m/s Face Velocity l/s - Pa 4V 1.6A 2.0A 9V 7V 3.0A 2.4A - - - - l/s - W 1.0 0.8 10V 50 1.0A 0 1.2A 2.5A 500 600 700 800 900 1000 AIR VOLUME (l/s) NOMINAL 2.3 m/s Face Velocity 250 200 150 100 50 2.3A l/s - Pa 1.9A 4V 2.8A 10V 2.5A 10V 0 800 900 1000 1100 1200 1300 AIR VOLUME (l/s) 2.5 m/s Face Velocity NOMINAL 7V 2.3A 2.9A 0.6 0.4 0.2 - - - - l/s - W 900 10V 800 7V 700 600 3.3A 500 400 INPUT (W) INPUT (kw) INPUT (W) ISD 141KYX AVAILABLE EXTERNAL PRESSURE (Pa) ISD 184KYX AVAILABLE EXTERNAL PRESSURE (Pa) 250 200 4V 150 100 50 1.0A ISD 224KYX AVAILABLE EXTERNAL PRESSURE (Pa) 250 200 150 1.1A 100 50 l/s - Pa l/s - Pa 2.0A 4V 1.6A 2.5A 10V - - - - l/s - W 1.0 10V 0.8 0.6 0.4 0 1.2A 2.5A 600 700 800 900 1000 1100 NOMINAL AIR VOLUME (l/s) 2.5 m/s Face Velocity 250 200 150 100 50 2.7A 2.7A 2.1A 1.1A 1.6A l/s - Pa 3.8A 5V 2.5A 0.9A 5V 5V 2.2A 0 1.3A 500 600 700 800 900 1000 AIR VOLUME (l/s) Nominal 2.5 m/s Face Velocity 9V 7V 7V 2.9A 0.2 INPUT (kw) - - - - l/s - W 1000 900 800 700 600 6.1A 500 400 0 1.3A 2.5A 800 900 1000 1100 1200 1300 AIR VOLUME (l/s) Nominal 2.5 m/s Face Velocity - - - - l/s - W 700 7V 600 10V 2.4A 9V 7V 4.2A 3.4A 500 400 300 200 INPUT (W) INPUT (W) Page 10 of 16

Performance Data SOUND LEVELS Sound Power Levels (SWL) Test Conditions: BS 848 PT2 1985. Installation Type A (free inlet and outlet). Direct method of measurement (reverberant room). Measured in decibels re 1 picowatt. INDOOR UNIT - SUPPLY AIR OUTLET OCTAVE BAND FREQUENCY Hz 125 250 500 1k 2k 4k Models FAN SPEED SWL db(a) SOUND POWER LEVELS (SWL) db 4 V 56 58 55 54 51 49 44 ISD 116 6 V 68 67 65 65 64 61 60 8 V 75 73 71 69 70 67 66 5 V 58 63 58 55 53 48 42 ISD 141 7 V 66 70 66 62 62 57 53 8 V 68 73 68 64 64 61 56 4 V 66 62 60 62 59 57 54 ISD 164 6 V 69 67 65 66 65 62 59 8 V 73 70 69 69 69 67 64 ISD 184 6 V 68 71 64 63 62 61 58 8 V 72 75 69 67 67 65 63 5 V 76 76 71 70 71 69 67 ISD 194 7 V 68 71 64 63 62 61 58 8 V 72 75 69 67 67 65 63 5 V 64 64 61 61 59 57 55 ISD 224 7 V 74 71 69 69 69 66 66 8 V 77 74 73 72 72 70 69 SOUND PRESSURE LEVELS (SPL) WITHIN A ROOM Deduct the room absorption effect below from the Sound Power Levels (SWL) above to obtain Sound Pressure Levels within a room. Note: Occupant at least 1.5 m from sound source. OCTAVE BAND FREQUENCY Hz 125 250 500 1k 2k 4k Room type ROOM ABSORPTION EFFECT Soft 4 8 11 11 11 11 Medium 3 7 8 9 9 9 Hard 0 1 3 4 4 5 Page 11 of 16

Performance Data OUTDOOR UNIT OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K Models FAN SPEED SWL db(a) SOUND POWER LEVELS (SPL) db OSA 116 OSA 141 OSA 164 OSA 184 OSA 194 OSA 224 LOW 69 76 67 69 60 58 52 MED 71 79 70 71 63 58 53 HIGH 73 81 73 72 66 62 55 LOW 72 81 71 72 61 58 56 MED 73 81 72 73 63 59 56 HIGH 74 81 74 73 67 61 57 LOW 68 73 66 66 63 57 51 MED 69 74 68 67 64 59 52 HIGH 72 85 69 68 66 60 54 LOW 68 74 67 65 63 57 52 MED 69 78 69 66 64 59 53 HIGH 70 79 70 67 65 60 55 LOW 68 74 67 65 63 57 52 HIGH 70 79 70 67 65 60 55 LOW 73 78 74 71 68 62 55 MED 74 78 76 73 69 63 57 HIGH 76 82 78 73 71 65 59 Sound Pressure Level (SPL) in decibels re 20 µpa Models FAN SPEED SPL @ 3 m db(a) SOUND PRESSURE LEVELS (SPL) db OSA 116 OSA 141 OSA 164 OSA 184 OSA 194 OSA 224 LOW 53 60 51 53 44 42 36 MED 55 63 54 55 47 42 37 HIGH 57 65 57 56 50 46 39 LOW 56 65 55 56 45 42 40 MED 57 65 56 57 47 43 40 HIGH 58 65 58 57 51 45 41 LOW 52 57 50 50 47 41 35 MED 53 58 52 51 48 43 36 HIGH 56 69 53 52 50 44 38 LOW 52 58 51 49 47 41 36 MED 53 62 53 50 48 43 37 HIGH 54 63 54 51 49 44 39 LOW 52 58 51 49 47 41 36 HIGH 54 63 54 51 49 44 39 LOW 57 62 58 55 52 46 39 MED 58 62 60 57 53 47 41 HIGH 60 66 62 57 55 49 43 Page 12 of 16

Dimensions (mm) ISD INDOOR UNIT DIMENSIONS (mm) POINT LOADS (kg) PROJECTION Model A B C D E F G H W X Y Z ISD 116 1150 968 934 1172 1066 1109 1003 55 15 18 17 15 ISD 141 1280 968 1099 1306 1066 1242 1003 120 16 19 17 16 ISD 164 1470 1098 1289 1496 1391 1433 1328 50 22 23 21 17 ISD 184 1470 1098 1289 1496 1391 1433 1328 50 26 24 20 14 ISD 194 1630 1098 1450 1656 1391 1593 1328 120 24 26 22 18 ISD 224 1630 1098 1450 1656 1391 1593 1328 120 24 26 21 20 Note: Fan motor can be accessed from panel above or sides: no more than two panels at once. Separable for ease of installation through small man holes minimum 550 mm sq. clear aperture. COIL SIDE D 45 F FIXED MTG CTRS C REFRIG. CONN S FAN SIDE 500 MIN. CLEARANCE 665 OPTIONAL SPRING OR FIXED MTG CENTRES H ELECTRICAL BOX 300 COIL SECTION 485 FAN SECTION 500 MIN. CLEARANCE OPTIONAL Spigot plate adaptors Double Inlet ISD 116/141: Ø400 mm ISD 141/164/184: Ø450 mm ISD 194/224: Ø450 mm ACCESS PANEL B G FIXED MTG CTRS E OPTIONAL SPRING MTG CTRS 50 ELECTRICAL BOX 50 25 430 OA REFRIG. CONN S 276 359 A OVERALL 7 DRAIN 19 OD SAFETY DRAIN 19 OD 785 OA 45 Drawings are NOT TO SCALE Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 13 of 16

Dimensions (mm) OSA OUTDOOR UNIT DIMENSIONS POINT LOADS (kg) PROJECTION Model J K L M N P W X Y Z OSA 116 965 750 398 475 183 1120 16 38 50 24 OSA 141 965 750 398 475 183 1120 16 38 50 24 OSA 164 1120 750 398 627 184 1120 16 56 46 30 OSA 184 1270 765 397 617 184 1155 17 54 32 36 OSA 194 1270 786 397 617 184 1155 22 60 38 40 OSA 224 1385 936 397 730 209 1335 36 72 48 29 150 MIN. CLEARANCE W Z 150 MIN. CLEARANCE X Y 750 MIN. CLEARANCE Note: The OSA 116/141 models have a single exhaust air fan. Refer page 15 for recommended interconnecting pipe sizes. 500 MIN. CLEARANCE ACCESS PANELS REFRIG. CONN S & ELECTRICAL CONDUIT ENTRY J OVERALL M 25 DIA. DRAIN HOLE N 72 K MTG CTR 12 DIA. HOLE+SLOT P OVERALL N 25 DIA. DRAIN HOLE L MTG CTR 425 OVERALL Drawings are NOT TO SCALE Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 14 of 16

Specifications System Indoor Unit ISD 116KYX ISD 141KYX ISD 164KYX ISD 184KYX ISD 194KYX ISD 224KYX ISD 224KYX Outdoor Unit OSA 116G OSA 141G OSA 164G OSA 184F OSA 194G OSA 224F OSA 224G Nominal Cooling Capacity * 1 kw 4.6~11.4 5.5~13.7 6.4~16.4 3.7~18.5~23.1 7.5~19.2 7.9~21.4~26.5 8.8~22.4 Net Cooling Capacity (MEPS) * 1 kw 11.1 13.4 16.0 17.9 18.7 20.6 21.1 EER / AEER (cooling) 3.28 / 3.26 3.14 / 3.12 3.13 / 3.12 3.15 / 3.10 3.25 / 3.20 3.11 / 3.10 3.18 / 3.16 Heating Capacity * 2 kw 4.3~10.8 5.1~12.6 6.0~15.0 3.8~18.7~22.5 6.7~16.8 8.0~23~27.6 8.6~21.6 COP / ACOP (heating) 3.55 / 3.35 3.52 / 3.50 3.60 / 3.58 3.29 / 3.27 3.58 / 3.56 3.12 / 3.10 3.26 / 3.24 Air Flow* 3 l/s 630 830 910 980 1065 1190 1190 Sound Levels * 4 Indoor Unit (SWL) 68 66 69 72 68 74 74 Outdoor Unit (SPL) 57 58 56 54 54 60 60 Power Source * 5 1 phase or 3 phase 3 phase 415 V a.c. 50 Hz Compressor type digital digital digital inverter digital inverter digital Indoor Fan Max. Current A 3.5 3.5 3.7 5 4 6 6 Running Amps (Total) OSASRKS (1Ø) A 17 20 OSASRKT (3Ø) A/ph. 7 / 5 / 5 9 / 6 / 6 10 / 7 / 7 12 / 9 / 9 12 / 8 / 8 15 / 10 / 10 15 / 9 / 9 Refrigerant HFC-410A ( R410A) Maximum Vertical Separation m 20 20 20 20 20 20 20 Maximum Line Length m 60 60 60 60 60 60 60 Pipe Sizes (Suction/Liquid) mm OD 16 / 9.5 16 * 6 / 9.5 19 / 9.5 19 / 9.5 19 / 9.5 22 / 13 22 / 13 Operating Range (outdoor ambient) Finish Cooling -10 C to 52 C Heating -15 C to 25 C Indoor Unit Outdoor Unit Weight (net/shipping) kg zinc galvanised steel grey polyester powder coat Indoor Unit 65 / 76 68 / 75 83 / 97 85 / 96 90 / 110 91 / 113 91 / 113 Outdoor Unit 128 / 131 128 / 134 134 / 142 139 / 154 160 / 198 185 / 195 185 / 195 Notes: * 1 Nominal Cooling Capacity (gross) at AS/NZS 3823 conditions: Indoor Entering Air Temperature 27 C D.B., 19 C W.B.; Outdoor Entering Air Temperature 35 C D.B. * 2 Heating Capacity at AS/NZS 3823 conditions: Indoor Entering Air Temperature 21 C D.B.; Outdoor Entering Air Temperature 7 C D.B., 6 C W.B. * 3 Supply air flow at Nominal Cooling Capacity conditions stated above. * 4 Sound Levels are measured at nominal cooling capacity conditions stated above. SPL measured at 3m from unit and at High fan speed. Optional Filter Box c/w EU2/G2 rated media (clean): Coil Face Velocity (m/s) 1.5 2.0 2.5 Pressure Loss (Pa) 5 9 13 * 5 Voltage range: Single phase systems 220 240 V; Three phase systems 380 415 V * 6 Use 19 mm size suction pipe above 20m line length. Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 15 of 16

www.temperzone.biz AUCKLAND Head Office 38 Tidal Rd, Mangere, N.Z. Private Bag 93303, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Phone (09) 279 5250 Fax (09) 275 5637 SYDNEY Head Office 14 Carnegie Place, Blacktown, NSW 2148 PO Box 8064, Seven Hills West, NSW 2147, AUSTRALIA. Email sales@temperzone.com.au Phone (02) 8822-5700 Fax (02) 8822-5711 NEWCASTLE Phone (02) 4962-1155 Fax (02) 4961-5101 TOWNSVILLE Phone (07) 4774-3506 Fax (07) 4774-3001 WELLINGTON Phone (04) 569 3262 Fax (04) 566 6249 ADELAIDE Phone (08) 8115-2111 Fax (08) 8115-2118 LAUNCESTON Phone (03) 6331-4209 Fax (03) 6333-0224 CHRISTCHURCH Phone (03) 379 3216 Fax (03) 379 5956 MELBOURNE Phone (03) 8769-7600 Fax (03) 8769-7601 JAKARTA Phone +62 (21) 2963 4983 Fax +62 (21) 2963 4984 BRISBANE Phone (07) 3308-8333 Fax (07) 3308-8330 SINGAPORE Phone +65 6733 4292 Fax +65 6235 7180 PERTH Phone (08) 6399-5900 Fax (08) 6399-5932 SHANGHAI Phone +86 (21) 5648 2078 Available from temperzone limited 2017 05/17 Pamphlet No. 4033a