SERIES 454FTB-WGF TECHNICAL SPECIFICATIONS

Similar documents
Sensors do not overheat at zero flow by using a unique constant temperature control method and power limiting design

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

Armstrong In-Line and Insertion Vortex Flow Meters

Model FT4X Thermal Mass Flow Meter & Temperature Transmitter

COUNTER CLOCKWISE FOR CLARITY (SEE MANUAL FOR SPECIFIC WATER & DUST TIGHT AP LOCAL ELEMENT ENCLOSURE ROTA FLAT PARALLEL TO FLOW.

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Low Profile Insertion Vortex

4.30 [109] 5.43 [138] FCI FlexMASSter ST98 Series: The Best Value in a 8.00 [203] High Performance. Flange. Mounting Hole. Positioning to Split Flow

Model FVP General Specification. Flanged Vortex Plate. Product Features

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

F-1500 SERIES INSERTION TURBINE FLOW METER

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

INSERTION MASS FLOW ELEMENTS

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

mass flowmeter for compressed air

Vortex Plate. Model VP General Specification. Product Features

F-2700 SERIES INSERTION VORTEX FLOW METER

Rosemount 3051CFA Annubar Flowmeter

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Hot Tap Insertion Vortex

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

VIM20 Vortex Insertion Flowmeter

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

K-BAR 2000B I F I E D. iso 9001:2000 C E R T Q U A L I T Y

VORTEX IN-LINE FLOW METERS

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

F-2700 SERIES INSERTION VORTEX FLOW METER

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

SITRANS FX300 4/289. System Overview. Overview

F-2600 SERIES INLINE VORTEX FLOW METER

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

CANADA SENSORS TECHNOLOGY INC.

Warnings and Cautions. Precision Flow Insertion Mass Flow Meter. Instruction Manual BULLETIN F-41-PFS FR# R

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

VLM20 In-line Vortex Flowmeter

UTM10 Series Ultrasonic Transit-time Flowmeters

Full Profile Insertion

Thermal Mass Flow Meter (Series MST)

mass flowmeter for compressed air

Level Measurement Continuous level measurement - Radar transmitters

220 Series Innova-Flo o

StackFlowMaster FPD581, FPD583 and FPD585 Stack gas metering systems

Masoneilan Series

Royce Total Suspended Solids Systems. Water & Wastewater

Vortex In Line Flow Meter

Rosemount 3051T In-Line Pressure Transmitter

Thermal Gas Mass Flowmeter Series TMF-300

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

AT100 Magnetostrictive Level Transmitter. High accuracy magnetostrictive liquid level transmitter K-TEK Products

The readings you need, right where you need them. AX Series Vortex Meters

TECHNICAL SPECIFICATIONS OF SAGE PRIME THERMAL MASS FLOW METER

Dissolved Oxygen Measurement System with Air Blast Cleaner

Micro Motion F-Series Coriolis Flow and Density Meters

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Multivariable Vortex Flow Meter

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

PitoMaster FPD550 Compact averaging pitot flowmeter. Economical flow metering solutions for gases, liquids and steam

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Appendix. Clearance. Skewed profiles. Application Schematics

Multivariable Vortex Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Rosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol

The readings you need, right where you need them. AX Series Vortex Meters

MAGTROL. TF Series Torque Flange Sensor. TF data sheet FEATURES. DESCRIpTION. AppLICATIONS

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Vortex In Line Flow Meter

FasTrak High Capacity Smart Positioner

F-2600 SERIES INLINE VORTEX FLOW METER

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

Micro Motion 7827 Digital Viscosity Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.

OPTIMASS 3000 Technical Datasheet

SATRON VDt Differential Pressure Transmitter

Installation and Operation Instructions DLP Series

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Thermal Gas Mass Flow Measurement and Control Instrumentation

VIM20 Vortex Insertion Flowmeter

Coriolis Flow Solutions for a Global Marketplace

Differential pressure transmitter PASCAL Ci4 Delta P

Point level measurement Capacitance switches

2100 Turbine Flow Sensor

Range of Ultrasonic Flowmeters.

SMARTLINK METER specifications and instructions

VIM20 Vortex Insertion Flowmeter

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Pressure Transmitter

Rosemount 3095FT MultiVariable Flow Data Logger

Instruction manual. Smart Thermal Mass Flow Meter. TYPE : 3000S Series. ientek Co., Ltd.

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Transcription:

Complex Technology Made Simple Insertion Flow Meter SERIES 454FTB-WGF TECHNICL SPECIFICTIONS The Kurz WGF single point insertion flow meter for wet gas environments includes the qualities and features found in all Kurz constant temperature thermal flow meters that make them outperform all other currently available thermal mass flow meters, including: The first thermal mass flow meter offering accurate and reliable wet gas flow measurements (patent pending) The highest repeatability, accuracy, and reliability available The fastest response to temperature and velocity changes in the industry Constant temperature anemometer sensor signal increases with increasing flow Interchangeable sensor and electronics (single circuit board) no matched sets Built in dry gas flow calculation on all flow units for saturated processes Continuous self monitoring electronics that verify the integrity of sensor wiring and measurements Sensor does not overheat at zero flow using a unique constant temperature control method and power limiting design Zero velocity as a valid data point Insensitive to left or right horizontal installations Completely field configurable using the flow meter user interface or via a computer connection User programmable correction factors to compensate for velocity profiles Velocity temperature mapping for wide ranging velocity and temperature Sensor Blockage Correction Factor (SBCF) Patented digital sensor control circuit (US 7,418,878) The Kurz WGF provides the solution for many applications and environments, including: Biogas Wastewater facilities Landfill sites Fogging in stacks Fan inlets EP greenhouse gas emissions Kurz Instruments is dedicated to manufacturing and marketing the best thermal mass flow meters available and to support our customers in their efforts to improve their businesses. 367533 Information subject to change without notice. Contact or visit Kurz online for complete specifications and ordering information. U.S. Patent Pending

Technical Specifications Specifications Velocity range 0 to 4,000 SFPM (18.6 NMPS) (ir) 0 to 2,000 SFPM (9.3 NMPS) (Biogas) Dry velocity accuracy ± (3% of reading +30 SPFM) 0.25% reading repeatability Velocity time constant 1.5 second for velocity changes at 4,000 SFPM (constant temp) Process temperature time constant 10 seconds for temp changes at 1,000 SFPM (constant velocity) Velocity angle sensitivity <0.25% per degree angle up to ±15 o Velocity dependent correction factors for flow rate Electronics operating temperature 13 o F to 149 o F ( 25 o C to 65 o C) (integral display) 40 o F to 149 o F ( 40 o C to 65 o C) (remote display) Process Conditions Process pressure rating Up to 150 PSIG (10 BRg) Process temperature rating 40 o F to 248 o F ( 40 o C to 120 o C) pprovals EP mandatory GHG certification CFR 98.34(c)(1) larm output conformity NMUR NE43 European Union CE compliance EMC, LVD, PED, WEEE, and ROHS CS, TEX & IECEx approvals pending for Nonincendive, Flameproof, and Explosion proof EN IEC 60079 0, EN IEC 60079 1 EN IEC 60079 15, EN IEC 61241 1, Class 1, Div 1 and 2 (Select models are CS pre approved) Transmitter Features luminum (Type 4, IP66) dual chamber polyester powder coated enclosure Two optically isolated looppowered 4 20 m outputs 12 bit resolution and accuracy Maximum loop resistance is 300 at 18 VDC, 550 at 24 VDC, 1400 at 36 VDC One 4 20m non isolated analog input Input power C (85 265V 47/63 Hz, 24 watts max) or DC (24V ±10%) Integral or remote user interface Easy to use interface Backlit display / keypad 2 lines of 16 characters each User configurable flow display (scrolling or static) User configurable English or metric units for mass flow rate, mass velocity, and process temperature ( o C, o F, KGH, KGM, NCMH, NLPM, NMPS, PPH, PPM, SCFH, SCFM, SCMH, SFPM, SLPM, SMPS) Flow valve PID controller and configurable control application Permits controlling set point velocity or flow rate through available control valve, damper, or 4 20 m interface Built in zero mid span drift check Built in flow totalizers and elapsed time User configurable digital filtering from 0 to 600 seconds Configuration/data access USB or RS 485 Modbus Meter memory 200 recent events, top 20 min/max, and 56 hours (10 second samples) of trends 3 year warranty Support & Element Components Sensor material C 276 alloy all welded sensor construction (standard) Sensor support 316L stainless steel (standard) C 276 alloy (optional) Sensor support diameter 3/4 and 1 (19 mm and 25mm) Sensor support length 6 to 60 (152 mm to 1524 mm) 3 year warranty Options djustable LCD/keypad orientation HRT communication Process control industry standard allows remote configuration, diagnostic monitoring, and online testing with handheld configurators Two optically isolated solid state relays / alarms Configurable as alarm outputs, pulsed totalizer output, or air purge cleaning Two digital inputs dedicated to purge and zero mid span drift check Pulsed output as a remote flow totalizer Hardware accessories vailable hardware includes flanges, ball valves, restraints, retractors, cable glands, conduit seals, cable, compression fittings, packing glands, and branch fittings

SERIES 454FTB-WGF OUTLINE DRWINGS.88 [22.35mm] (5.44) [138.18mm].64 [16.26mm] (5.25) [133.35mm] DISPLY CN BE ROTTED T 90 INCREMENTS FOR PROPER VIEWING DIRECTION DIRECTION RROW MSS TRNSMITTER L2 (NOTE 2) L (NOTE 1) (NOTE 1) MOUNTING FLNGE (OPTIONL) SUPPORT U LC 2.00 [50.8mm] 0.78 [19.81mm] D (SEE TBLE 1) SUPPORT FITTING VIEW - POWER, GROUND, & OUTPUTS SHIELDED CBLE, SELS, FITTINGS, & CONDUIT (Customer-Supplied) ELECTRONICS ENCLOSURE ID TG (Optional) DIRECTLY TTCHED ELECTRONICS ENCLOSURE (T) W/ DISPLY & KEYPD OPTION SHOWN IN STNDRD ORENTTION POWER, GROUND, & OUTPUTS SHIELDED CBLE, SELS, FITTINGS, & CONDUIT (Customer-Supplied) 3/4" MNPT PLUG WIRE TERMINL MSS TRNSMITTER ELECTRONICS ENCLOSURE DISPLY CN BE ROTTED T 90 INCREMENTS FOR PROPER VIEWING DIRECTION CONDUIT SELS (Customer-Supplied) (Typical) 5-CONDUCTOR SHIELDED CBLE IN RIGID CONDUIT OR CBLE WITH PERIMETER BONDED SEL (Customer-Supplied) ELECTRONICS FOR REMOTELY TTCHED W/ DISPLY & KEYPD OPTION (SHOWN) (NOTE 4) PROBE SSEMBLY FOR REMOTELY TTCHED (NOTE 3) SLOT.31 x.50 [7.87mm x 12.70mm] 4x (Typical) ZONE 2 ZONE 1 Ex n DESIGN FIBERGLSS ENCLOSURE TYPE 4, IP66 (4.00) [101.60mm] LCD DISPLY SIGNL OUTPUTS (4.42) [112.27mm] (2.00) [50.80mm] 1/2" FNPT Ex d DESIGN LUMINIUM ENCLOSURE TYPE 4, IP66 WIRE TERMINL (8.50) [215.90mm] (8.94) [227.08mm] INPUTS POWER INPUT (2.25)[57.15mm] (2.25)[57.15mm] (1.85)[46.99mm] 3/4" FNPT (Typical) (6.50) [165.10mm] 5-CONDUCTOR SHIELDED CBLE IN RIGID CONDUIT OR CBLE WITH PERIMETER BONDED SEL (Customer-Supplied) ELECTRONICS FOR REMOTELY TTCHED (WLL MOUNT) PROBE SSEMBLY FOR REMOTELY TTCHED W/ DISPLY & KEYPD OPTION (SHOWN) (NOTES 5 & 6) (NOTES 5 & 6)

SERIES 454FTB-WGF OUTLINE DRWINGS (cont'd) 3/4" MNPT 5.03 [127.76mm] 4.75 [120.65mm] CUSTOMER HOOK-UP SIDE. 3/4" FNPT 5.03 [127.76mm] 4.75 [120.65mm] 5.25 [133.35mm] MSS TRNSMITTER 5.25 [133.35mm] 4.61 [117.09mm] 4.37 [110.99mm] 4.61 [117.09mm] 4.37 [110.99mm] 1.13 [28.70mm] 1.06 [26.90mm] W3 (SEE TBLE 2) WIRE TERMINL (NOTE 4) MOUNTING FEET SUBJECT TO CHNGE W2 W1 (SEE TBLE 2) (SEE TBLE 2) ELECTRONICS ENCLOSURE (SHOWN W/ WINDOW LID) NOTES: 1) FOR FLNGED OPTION: L = (U + L2-2.00 [50.8mm]), U = 4.00 [101.6mm]. 2) L2 TO BE 5.00 [127mm]. 3) THIS PROBE CONFIGURTION LSO USED FOR DIRECTLY TTCHED, DC POWERED, WITH NO DISPLY. 4) WIRE TERMINIL USED FOR ELECTRONICS FOR DC POWERED, WITH NO DISPLY. 5) ENCLOSURE STYLES ND DIMENSIONS RE SUBJECT TO CHNGE. 6) THIS CONFIGURTIONS LLOWS FOR PROBE SSY TO BE MOUNTED IN ZONE 1 RE ND FOR REMOTE ELECTRONICS TO BE MOUNTED IN ZONE 2 RE. INPUT DISPLY / POWER KEYPD C YES C NO 24VDC YES NO 24VDC (NOTE 4) WIRE TERMINL J-BOX (FOR REMOTE OPT.) TBLE 1 PROBE DIMETER DIMENSION MODEL NO. D -12 0.75 [19.5mm] -16 1.00 [25.4mm] TBLE 2 ENCLOSURE DIMENSION (MX.) (MX.) (MX.) W1 W2 W3 3.63 [92.20mm] 5.01 [127.25mm] 3.41 [86.61mm] 4.69 [119.13mm] 3.16 [80.26mm] 5.01 [127.25mm] 2.81 [71.37mm] 4.69 [119.13mm] 3.63 [92.20mm] 5.01 [127.25mm] 3.41 [86.61mm] 4.69 [119.13mm] 5.01 [127.25mm] 4.88 [123.95mm] 3.16 [80.26mm] 2.81 [71.37mm]

Toll free 800-424-7356 Main 831-646-5911 Fax 831-646-8901 sales@kurzinstruments.com Insertion Flow Meter Order Configuration 756 4 1 0 Parent Number F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 Parent Number Model 756410 454FTB-WGF F1 Option Probe Support Diameter B 0.75 (19 mm) (6 36 probe length) C 1 (25 mm) (6 60 probe length) F2 Option Probe Support & Flange Material 2 316L stainless steel 3 C-276 alloy F3 Option Probe Support Length B 6 (152 mm) C 9 (229 mm) D 12 (305 mm) F 18 (457 mm) H 24 (610 mm) J 30 (762 mm) K 36 (914 mm) M 48 (1219 mm) P 60 (1524 mm) F4 Compression Fittings or Flanges Choose one only - None, Compression Fitting, or Flange Option Compression Fittings 1 None 2B 2D 2G 2J Option 1 Class 150 lbs. 0.75 MNPT (0.75 probe only), stainless steel front and back ferrules 0.75 MNPT (0.75 probe only), PTFE-compound front and back ferrules 1 MNPT (0.75 or 1 probe), stainless steel front and back ferrules 1 MNPT (0.75 or 1 probe), PTFE-compound front and back ferrules Option 2 Class 300 lbs NSI 16.5 Flange 1 1 None 3D 4E 0.75 (19 mm) 3F 4G 1 (25 mm) 3J 4K 1.5 (38 mm) 3L 4M 2 (51 mm) 3N 4P 2.5 (64 mm) 3S 4T 3 (76 mm) 3U 4V 4 (102 mm) F5 Option Flange U Dimension 0.75 and 1 probe diameter 1 probe diameter only Enter 000 for no flange connection. Enter U-dimension to nearest 10th of an inch without a decimal point. For example, 7.7 is 077 and 23.6 is 236. Note: Convert metric units to English units. F6 Option Electronics Configuration (pprovals Pending, select models CS Certified Explosion Proof) E J F7 Option Keypad/Display 1 Keypad / Display 2 Blind Integral - Standard Display viewing luminum Type 4, IP66 enclosure Integral - Display rotated 180 o for viewing luminum Type 4, IP66 enclosure Remote - Transmitter and sensing element separate luminum Type 4, IP66 enclosures F8 Option Power C (85-265V 47/63 Hz, 24 watts max) D DC (24V ±10%) F9 Option nalog and Digital Inputs/Outputs 2 Standard Two 4-20 m isolated outputs 3 Full 5 HRT Two 4-20 m isolated outputs, two relays, two digital inputs, one non-isolated 4-20 m input HRT communication protocol, one 4-20 m isolated output, two relays, two digital inputs, one non-isolated 4-20 m input F10 Option Gas Type ir (laboratory calibration only) D Biogas (methane and carbon dioxide mix) Y Customer specified F11 Option Percent of Methane Enter two digits for percent of methane. Enter two zeros (00) for ir only. Enter YY for all other gases. F12 Option Velocity Calibration Range B 300 SFPM (1.4 NMPS) C 600 SFPM (2.8 NMPS) E 1,000 SFPM (4.7 NMPS) G 2,000 SFPM (9.3 NMPS) K 4,000 SFPM (18.6 NMPS) (ir only) F13 Option Calibration Type 1 Correlation 2 Laboratory