USER MANUAL MODEL NUMBER: FOG-IT6 FG-NA-N130 FG-NA-26SS AND RELATED ITEMS. Wall-Mounted Fog System. English (Original Instructions)

Similar documents
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

USER MANUAL MODEL NUMBER: FG-10N-2 FG-10NK-2 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: FG-10N-3 FG-10NK-3 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: FG-10N-2 FG-10NK-2 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: GK2T

USER MANUAL MODEL NUMBER: FG-10N-3 FG-10NK-3 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

USER MANUAL MODEL NUMBER: FST FSTK FSTV. Flooded Suction Tank. English

USER MANUAL MODEL NUMBER: SP-WC AND RELATED UNITS

USER MANUAL MODEL NUMBER: GI-5N GI-5NK GI-5NV AND RELATED UNITS. 5 Gallon Air Operated Portable Gel Equipment. English (Original Instructions)

Wall Mounted Foam Unit MD20016 USER MANUAL

USER MANUAL MODEL NUMBER: GI-25N GI-25NK GI-25NV AND RELATED UNITS. 25 Gallon Air Operated Portable Gel Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: FI-WC FI-WCK FI-WCV FI-WC-AP FI-WC-ST AND RELATED UNITS

TS5600 TS5600V TS5600K

FI-10 FI-10K FI-10V FI-10 ST FI-10K ST FI-10V ST

USER MANUAL MODEL NUMBER: SP-20N SP-20NK SP-20NV AND RELATED UNITS. 20 Gallon Air Operated Portable Spray Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: FI-5N FI-5NK FI-5NV FI-5N-ST FI-5NK-ST FI-5NV-ST AND RELATED UNITS. 5 Gallon Air Operated Portable Foam Equipment

USER MANUAL MODEL NUMBER: FI-50N FI-50NK FI-50NV AND RELATED UNITS. 50 Gallon Air Operated Portable Foam Unit. English (Original Instructions)

USER MANUAL MODEL NUMBER: CTX2V-EZB. EZBlend Chemical Transfer Unit. English (Original Instructions)

USER MANUAL MODEL NUMBER: GI-30N-AM GI-30NK-AM GI-30NV-AM AND RELATED UNITS. 30 Gallon Air Operated Portable Gel Unit with Agitator

10 Gallon Portable Air-Operated Foaming Unit

USER MANUAL MODEL NUMBER: FI-30N-SM FI-30NK-SM FI-30NV-SM AND RELATED UNITS. 30 Gallon Smart Foam Unit. English (Original Instructions)

USER MANUAL MODEL NUMBER: SS2 SS2-FMH SS2-MBS AND RELATED UNITS

900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg.

Caution! Pg. 1 of 5 I-932

USER MANUAL. 2.5 and 5 Gallon Chemical Transport Jug. English

USER MANUAL. 2.5 and 5 Gallon Chemical Transport Jug. English

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS PRIOR MLS COVERED IN THIS MANUAL

Doorway Foamer. Packers Chemical 3729 Peddle Hollow Rd Kieler Wi, Phone Fax

Set-Up Instructions. for EC-VM400. Motorized Valves

Cleaning Systems Inc. 2 P Rev:03

Owner's Manual. Model: ( ) (150 Gallon, 5.5 HP Skid Sprayer) Technical Specifications. General Information. Warranty/Parts/Service

PORTABLE EXTRACTOR 500/500H ( ) 115V 230V

Low Pressure Series - Accessories. High Pressure Series - Accessories

PARTS LIST STALLION 8 SC

PARTS LIST, COUNTER CONVECTION STEAMERS MODELS SN-3E, SN-4E, SN-5E PARTS LIST COUNTER CONVECTION STEAMERS BLODGETT MODELS: SN-3E SN-4E

FI-15 OWNER S MANUAL

Owner's Manual. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/2.5 H.P. Engine, 4-Roller Pump, Deluxe Handgun) Technical Specifications

910 BHF OWNER S MANUAL. Pg. 1 of 9

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

ELECTRIC SPRAYER CONTROL SYSTEM OWNERS MANUAL

Owner's Manual. (60 Gallon 3 Point Sprayer w/pump, Coupler, & 7-Nozzle Boom Assembly) Assembly. Information About The Sprayer

Spare Parts List. ( , , ) Dominator 500 PSI-13 Gallon

Atomizer 36-DC User Guide

PRICE LIST

MODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO & UP

ProMinent Beta Solenoid Diaphragm Metering Pumps

PRO-II SERIES SAND MEDIA FILTRATION SYSTEMS Kits and Parts Listing

MODEL EVA PARTS MANUAL Rev.1.05

SST Series Sand Media Filtration Systems

Parts Manual FRONT-FOLD BOOMS MODELS 80, 90 & 100 HYDRAULIC FOR TA1200 & TA1600 SPRAYERS. Serial Number B & Higher. Part No.

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

VALVES std $ fp $ fp $

Parts Catalog TECHNICAL DOCUMENTS TABLE OF CONTENTS. Electric. Other. Non-electric

:,Rhino SD/XD G/D 24 Vdc ISO

VALVES. FIMCO Code # MFG Part # std $ fp $ fp $

Fluid Dispensing Systems

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC. ML /240 V. 8.5kW ML V. 8.5kW 3-PAN PRO

Hydracel High Pressure Pump

M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.05A

1 1/4 NPT FILTER SIZE DESIGNATION PRICE 2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS 1 1/4 SCREENS 2 SCREENS HOLE SIZE DESIGNATION PRICE

P34AXL Series Parts List

PARTS LIST WRANGLER 2625 DB

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A

MODEL GLC PARTS MANUAL REV.1.02A

Electronic Service Manuals

LITTLE SOIL SQUIRT. RF809-4 LITTLE SOIL SQUIRT (Completely assembled unit) $ (Weight 110 Pounds) Effective February 17,

PARTS LIST WRANGLER 2625 DB

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company

P RECISION P ERFORMANCE EASY CALIBRATION PRECISE IS NICE FOR 35 YEARS. (352) Orange Lane Hawthorne, FL 32640

INSTALLATION INSTRUCTIONS

DIAPHRAGM PUMPS & ACCESSORIES

Gaskets. Fluid Handling Components. Bee Valve offers a full line of original and replacement gaskets to meet all your needs.

2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

1 1/4 NPT FILTER 2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS 1 1/4 SCREENS 2 SCREENS. Hole Size Designation 150 Mesh 1M150

DRINK SINGLE CUP BREWER

MODELS CMA-180/180TALL Including 480V MACHINES PARTS MANUAL Rev 2.08A

Gregson-Clark SPREADER-MATE

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

Systems to be regarded as the # 1 Sanitizing System available on the market. Sage TM

This catalog contains the following geothermal accessory products and specification guides:

DIAMOND P R O D U C T S

MODEL EVA PARTS MANUAL Rev.1.03

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

MODELS AH/B/C/Scullery/Pizza/Bowl PARTS MANUAL Rev 1.03B

ILLUSTRATED PARTS LIST

TUF-SKIN VALVES. Universal sales 1~1~2O15. Catalog ~ Price List. UNIVERSAL SALES Booth Street Junction City, OR

Owner's Manual. Model: ATV QR ( ) *** IMPORTANT REMINDER *** (25 Gallon Lawn & Garden/ATV Sprayer w/standard 7-Nozzle Boom Assembly)

Owner's Manual. Model: LG ( ) *** IMPORTANT REMINDER *** (25 Gallon Lawn & Garden Trailer Sprayer) Technical Specifications

Model 69GL T PL



Heavy Duty Sprayer Owners Manual Model MS-O

PARTS LIST PONY 20 SCA

Shaft Adapter (5/8 to 3/4 ) NOTE CI = Cast Iron, N = Ni-Resist, SL = Silver Last. Series Series 7560

PARTS LIST CHAMP 2929 WITHOUT SIDEKICK CHEMICAL DISPENSOR WITH SIDEKICK CHEMICAL DISPENSOR

Transcription:

USER MANUAL MODEL NUMBER: FOG-IT6 FG-NA-N130 FG-NA-26SS AND RELATED ITEMS Wall-Mounted Fog System English (Original Instructions)

WARNING Read this manual completely and understand the machine before interacting with it. Read all instructions before installing or operating unit. Always wear appropriate personal protective equipment (PPE) when operating or servicing unit. Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Material Safety Data Sheet (MSDS). Fogging with chemical products can be hazardous. Know the hazards of your chemical products prior to use. Wear appropriate personal protective equipment and follow all instructions and safety precautions in accordance with the MSDS for your chemical product. If this unit is modified or serviced with parts not listed in this manual, the unit may not operate correctly. Before performing any maintenance on this unit, disconnect the unit from the electrical power source and compressed air supply, and open the air purge valve (QFSOV38) to release any air pressure stored in the system. Do not exceed an incoming air pressure of 150 psi (10.3 bar). Do not exceed a fluid temperature of 100 F (37 C). Only use clean and dry air. Air must be filtered and free of moisture or pump life will be diminished. If needed, install a water separator (WS-20CFM) before unit. Do not use an air lubricator before the unit. Never use unit if it is damaged or leaking. Disconnect unit from electrical power source before servicing. OPTIONS Control box Nozzle assemblies Pump Seal Material Santoprene (standard) FOG-IT6 Viton (V) Kalrez (K) Add bold option codes to item number as shown. For standard options, no option code is needed. Examples: FOG-IT6 (standard unit with Santoprene pump seals) FOG-IT6V (unit with Viton pump seals) FG-NA-N130 FG-NA-26SS PROTECT THE ENVIRONMENT Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations. Always remember to recycle. Specifications and parts are subject to change without notice. Page 2 of 8 02272014

REQUIREMENTS Compressed air requirements WITH FG-NA-N130 NOZZLES: At factory air pressure setting of 50 psi (3.4 bar): 2 cfm (56.6 l/min) for control box, plus 2.5 cfm (70.8 l/min) per nozzle WITH FG-NA-26SS NOZZLES: At factory air pressure setting of 50 psi (3.4 bar): 2 cfm (56.6 l/min) for control box, plus 5 cfm (142 l/ min) per nozzle Liquid temperature range Electrical requirements Operating voltage Chemical compatibility Maximum incoming air pressure: 150 psi (10.3 bar) 40-100 F (4.4-37 C) 120 VAC at 60 Hz, 2 amps (GFCI protected outlet) Maximum incoming air pressure: 150 psi (10.3 bar) 120 VAC Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or MSDS for your product. SPECIFICATIONS WITH FG-NA-N130 NOZZLES: WITH FG-NA-26SS NOZZLES: Power type Compressed air, electricity Chemical pickup type Draws from pre-mixed solution Number of products One product unit can draw from Suction line length/ 8 ft. (2.4 m) hose with 3/8 in. (9.5 mm) inside diameter) diameter Flow rate* 7.9 oz/min (0.23 l/min) 5.3 oz/min (0.16 l/min) Pump seals Santoprene, Viton, or Kalrez Nozzle construction Polypropylene and kynar Celcon, stainless steel, EPDM and nylon Timer operation type Delay on make single shot Droplet size 15 micron at 50 psi (3.4 bar) 35 micron at 50 psi (3.4 bar) Coverage area 1 liter of solution will cover approximately 1000 cubic feet** Coverage pattern Flat pattern with projection up to 10 ft. (3 m) from nozzle Pattern up to 8 ft. (2.4 m) wide (side to side) and 3 ft. (0.9 m) thick (top to bottom), with projection up to 15 ft. (4.6 m) from nozzle Number of nozzles*** 1-20 nozzles per control box 1-12 nozzles per control box Tubing/fitting sizes Designed for use with 3/8 in. (9.5 mm) outside diameter tubing between control box and nozzle(s) *Dilution rates and flow rates given are based on chemical with viscosity of water and factory air pressure settings. **Area covered and run time may vary based on humidity, air flow, and product used. ***Number of nozzles is dependent upon air supply (see Compressed Air Requirements) Page 3 of 8 02272014

Installation Instructions 1. Remove all components from packaging. 2. Select an area to mount the control box. Note: The control box should be mounted to a vertical wall. We recommend mounting the control box at a height of 6 ft. (1.8 m) or less. The chemical suction line must reach the bottom of the chemical container. The bottom of the chemical container should not be positioned higher than the bottom of the control box. 3. Attach the control box mounting feet to the back of the control box, using the four screws provided in the parts package. 4. Mount the control box to the wall using the four screws and plastic anchors provided in the parts package. Note: To drill holes for the plastic anchors, use a 5/16 inch drill bit. 5. Install the air purge valve (QFSOV38) and tee fitting () as shown in the diagram. AIR PURGE SYSTEM DIAGRAM SOLUTION OUT AIR OUT TO NOZZLES AIR PURGE QFSOV38 6. Mount the fog nozzle assembly (FG-NA-N130, FG-NA-26SS) in the desired location, using the included screws and plastic anchors. Repeat as needed for multiple nozzles. 7. Run tubing (H38CP) from the tee fitting () to the solution inlet fitting on a nozzle assembly. Then run tubing from the solution outlet fitting on the original nozzle to the solution inlet fitting on the next nozzle. Repeat as needed for multiple nozzles. 8. Run tubing (H38CP) from the air outlet (QF1238) on the control box to the air inlet fitting on a nozzle assembly. Then run tubing from the air outlet fitting on the original nozzle to the air inlet fitting on the next nozzle. Repeat as needed for multiple nozzles. Note: The air and solution lines must be routed to the appropriate fittings (as labeled), or the fog quality of the unit will be negatively impacted. Make sure to insert the tubing all the way into the fittings to ensure proper connection. 9. When you reach the last nozzle, either plug the air and solution outlet fittings, or loop the air and solution lines from the last nozzle back into the system. Note: Depending on your configuration, plugs (QFP38), additional tee fittings () and/or additional tubing (H38CP) may be required to complete the installation. 10. With the air inlet valve (HV60-H) in the closed position, connect a compressed air line to the air inlet fitting (SSE12). The air inlet fitting is 1/2 in. FPT. 11. Set the timer (TRDU120) for the desired delay time and run time, as described in the timer adjustment instructions. TIMER ADJUSTMENT INSTRUCTIONS The TRDU120 is a multifunction timer. To set the timer: 1. The five MODE switches (A-E) in the bottom left corner set the timer function. For fogging applications, switch A and switch D should be ON, and the other switches (B, C, and E) should be OFF. This puts the timer in Dual Mode, with the 1st Delay functioning as a delay time, and the 2nd Delay functioning as a singleshot run time. 2. The remaining three switches in the bottom row set the time interval. One switch lets you choose MIN (minutes) or SEC (seconds). The other two switches let you select a multiplier (x0.1, x1, x10, or x100), which can increase or reduce the total active time. 3. The switches in the upper column control the active time. In Dual Mode, the top 5 switches control the 1st Delay (delay time), and the lower 5 switches control the 2nd Delay (run time). The active time for each function is equal to the total of the numbers next to any of these switches that are ON, times the selected multiplier. Page 4 of 8 02272014

12. With the power switch (TS2, TS2PLATE, TSBT12) in the OFF position, plug the unit into a GFCI protected 120 VAC power outlet. 13. Follow all instructions from chemical manufacturer. Place the chemical suction line into a container of pre-mixed chemical solution. Operation Instructions Fogging with chemical products can be hazardous. Know the hazards of your chemical products prior to use. Wear appropriate personal protective equipment and follow all instructions and safety precautions in accordance with the MSDS for your chemical product. 1. Prepare the area to be fogged. 2. Verify the delay time and run time settings on the timer (see Timer Adjustment Instructions). 3. Make sure the air inlet valve (HV60-H) is open, and the air purge valve (QFSOV38) is closed. 4. Turn the power switch (TS2, TS2PLATE, TSBT12) to the ON position. 5. To activate the unit, push the green button (BUT78GR). The unit will begin cycling through the delay and run time intervals set on the timer, beginning with the delay time. 6. At the end of the run time, the unit will shut off. Observe appropriate safety precautions when reentering the area, in accordance with the MSDS for your chemical product. 7. Turn the power switch (TS2, TS2PLATE, TSBT12) OFF to prevent unwanted activation of the unit 8. With the air inlet valve (HV60-H) in the open position, open the air purge valve (QFSOV38) to clear any solution from the lines. Close the air purge valve (QFSOV38) after all solution has been cleared from the system. Maintenance Instructions To keep your fog unit operating properly, periodically perform the following maintenance procedures: Note: Before performing any maintenance, disconnect the unit from the electrical power source and compressed air supply, and open the air purge valve (QFSOV38) to release any air pressure stored in the system. Inspect the pump (P56/P56K/P56V) for wear and leaks. Inspect all hoses for leaks or excessive wear. Make sure all hose clamps and push-fittings are in good condition and properly secured. Check the chemical suction line and strainer for debris and clean as needed. Drain your air compressor tank on a regular basis to help extend pump life. An air source with a high moisture content will accelerate pump wear. Note: If your air source has a high moisture content, you may wish to install a water separator (WS-20CFM) before the unit. Troubleshooting Instructions If air passes through the pump (P56/P56K/P56V) without cycling, the pump needs to be replaced. Check the chemical suction line and strainer for debris or damage. Clean or replace as needed. To prevent damage to the unit, the strainer (STR14) must always be used. Page 5 of 8 02272014

CONTROL BOX ASSEMBLY Inside View P56, P56K or P56V P56-BRKT P56-BRKT-SCREW FW38 PL-G WC14BC H14B-H (Available per.) SSC38 CV38 EC14-2 HHSB1214 SSC38 HBF3812 QF1238 H38B-H (Available per.) SHW3 HB1438 STR14 TRDU120 CC8463 TS2, TS2PLATE, TSBT12 R38 AG100 BA38 SSE12 HV60-H WR1A BA38 BEL38M38M HHSB1238 ACV3D CC3224 HBSS1238 SST12 CONTROL BOX ASSEMBLY Outside View PL-G CC3224 TS2, TS2PLATE, TSBT12 BUT78GR FW38 SSE12 HV60-H BN3838 HHSB1238 OPTIONAL COMPONENT WATER SEPARATOR Item Number: WS-20CFM Page 6 of 8 02272014

NOZZLE ASSEMBLY Item Number: FG-NA-N130 (Included in parts package) QF1438 SSA14 FWLG14 SSLB 14 PFN-N130 QF1438 H38CP (Available per.) NOZZLE ASSEMBLY Item Number: FG-NA-26SS or FOG-IT6-NP H38CP (Available per.) PHC14 PFN26-SS BEL14M14M QF1438 SSLB 14 T14B TW916 SSA14 QF1438 Page 7 of 8 02272014

ITEM NUMBER ACV3D AG100 DESCRIPTION 1/2 DEMA AIR SOLENOID, BRASS - 120v - 31gpm 1.5 INCH DRY MODEL 20 DUAL SCALE GAUGE B103225 10-32 X 1/4in PHIL MACH SCREW 18-8 BA38 BEL14M14M BEL38M38M BN3838 BUT78GR CC3224 CC8463 CV38 3/8 MPT X 3/8 FPT ADAPTOR BRASS ELBOW 1/4in MPT X 1/4in MPT BRASS ELBOW 3/8in MPT X 3/8in MPT BRASS HEX NIPPLE 3/8in X 3/8in PB OPR NO CB LTC BLACK 1/2 NPT 1/2in NPT BLACK LOCKNUT PVC CHECK VALVE 3/8 BARBS - SS SPRING EC14-2 OETIKER CLAMP 13.8 FW38.687 ID X 1-1/2 OD X.07 TK FLATWASHER (5/8) 18-8 FWLG14.569 ID X 1.28 OD X.08 THICK FLAT WASHER SS 18-8 H14B-H 1/4 INCH BLUE HOSE- GOODYEAR HORIZON - Available per ft. H38B-H 3/8 INCH BLUE GOODYEAR HORIZON HOSE - Available per ft. H38CP 3/8 IN OD POLYETHYLENE TUBING - NATURAL - Available per ft. HB1438 HBB1414 HBF3812 HBSS1238 1/4in MPT X 3/8in HOSE BARB (PLASTIC) BRASS 1/4 X 1/4 HOSE BARB HOSE BARB 3/8 X FEMALE PIPE THREAD 1/2 IN STAINLESS HOSE BARB 1/2mpt X 3/8 barb HBSSEL1438 STAINLESS HOSE BARB ELBOW 1/4 INCH NPT X 3/8 HOSE BARB HHBB1418 HEX HEAD BRASS BUSHING 1/4in X 1/8in HHSB1214 HEX HEAD S.S. REDUCER BUSHING 1/2 X 1/4 HHSB1238 HEX HEAD S.S. REDUCER BUSHING 1/2in X 3/8 HV60-H P56 P56K P56V 20756103B HB14P HB5638 HB5638K HB5638V P56-BRKT P56-BRKT-SCREW PB16138 1/2 S.S. BALL VALVE W/ STRAIGHT HANDLE W/O WELD 5700 PUMP WITH SANTOPRENE SEALS - INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT 5700 PUMP WITH KALREZ SEALS - INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT 5700 PUMP WITH VITON SEALS - INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT Polypro G57 Air Port x HB Straight, w/ Viton o-ring 1/4in BRASS HB AIR FITTING /G57/P56 HOSE BARB FOR P56 PUMP HOSE BARB FOR P56K PUMP HOSE BARB FOR P56V PUMP PUMP BRACKET- STAINLESS STEEL HI LO SCREW FOR RETAINING P56-BRKT POLYPROPYLENE CONTROL BOX - WORKING DIMS 16x13x8 - PUMP MOUNT PB16138-GSKT PB16138-LATCH PB16138-PIN NEOPRENE GASKET 0.220 INCH ROUND CORD STOCK LATCH FOR PB16138 STAINLESS STEEL HINGE PIN FOR CONTROL BOX PB16138-1/8 x 4 3/4 x 1/2inches PBFT-PP MOUNTING FEET FOR POLYBOX - PB16138 - POLYPROPYLENE PFN26-SS PFN-N130 PHC14 PNEUMATIC FOG NOZZLE WITH STAINLESS STEEL TIP - HIGH FLOW Pneumatic Fog Nozzle(1/4QMJ+SUQF-N130 ASSEMBLED) - Polypropylene and KYNAR BLACK POLY HOSE CLAMP PL16138 CONTROL BOX LID - POLYPROPYLENE - 16x13x8 - HINGED LOCKABLE LID PL-G GREEN PILOT LIGHT - MC GILL QF1238 MALE CON. 3/8in TUBE X 1/2in MPT - POLYPROPYLENE QF1438 MALE CON. 3/8in TUBE X 1/4in MPT - POLYPROPYLENE QFSOV38 R38 SHUT OFF VALVE 3/8in TUBE POLYPROPYLENE UNION TEE 3/8in TUBE POLYPROPYLENE CFDR60-3NG FILTER, REG 3/8in S1034FHL 10 X 3/4 PHIL FLAT HI-LO THRD SCREW 18-8 SHW3 SN1212 SSA14 3in LONG COATED WEIGHT 1/2in HEX STAINLESS STEEL NIPPLE SS304 MALE/FEMALE ADAPTOR 1/4 NPT X 1/4 NPT SSC38 WORM GEAR CLAMP, S/S (.25-.63) SSE12 SSLB 14 SST12 STR14 T14B TRDU120 TRS11 TS2 TS2PLATE TSBT12 TW916 WC14BC WC14FRK WCB14F WCB14FY WMS14 WMS14A WR1A WS-20CFM STREET ELBOW 1/2in - 316 S.S. 14GA SS BRACKETS W/SLOTS 1/2in FPT 304 S.S. TEE 40 MESH SUCTION LINE STRAINER 1/4 MNPT FEMALE BRASS TEE 1/4in 120 VOLT MULTI-FUNCTION TIME RELAY 11 PIN MAGNAL SOCKET TOGGLE SWITCH SPST ON/OFF SWITCH PLATE TOGGLE SWITCH BOOT 1/2 INT TOOTH L/W 410SS BUTT CONNECTOR 14-16 - INSULATED NARROW FORK TERM. CONNECTOR 14-16 - 1/4 FEM INSULATED CONNECTOR 10-12 - 1/4in FEMALE INSULATED CONNECTOR 14 X 1 1/4 HEX W/H SMS SLOTT, S/S 5/16 X 1 1/2 STRAIGHT PLASTIC ANCHOR 18/3 SJOOW 90 BLACK N.A. W/ 5-15P & 7in ROJ TSUNAMI WATER SEPARATOR/AIR DRYER 20 CFM Page 8 of 8 02272014