High-Pressure Differential Scanning Calorimetry

Similar documents
Isothermal Battery Calorimetry IBC 284

NOTOS Multi Screw Pumps. High Efficiency and Unique Design

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Grinding & Dispersing. NETZSCH OMEGA Economic Dispersionizer... Taking Dispersion One Step Further. our technology YOUR SUCCESS

Grinding & Dispersing. PMH/PML Planetary Mixing and Kneading Machine Always the right spin! our technology YOUR SUCCESS

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9

Edexcel GCSE Chemistry. Topic 8: Fuels and Earth science. Fuels. Notes.

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Costumer Service. Comprehensive technical support for NETZSCH customers

STS Directory Accreditation number: STS 0630

Excellence in gas analyzers since Over 180 years of JY optical experience. The expertise of Horiba combustion technology

Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas

THC Heated FID 3-300A

Agilent 6850 Series II Network GC System G2630A Performance Specifications

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Lube & Seal for Power Transmission Engineering. Enhanced and prolonged sealing with Klüber Lubrication and Freudenberg Sealing Technologies.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

More Precision. mainsensor Magneto-inductive displacement sensor

Application Note. Author. Introduction. Energy and Fuels

Sealon Adhesive PTFE Gasket Tape. Technical Data Sheet

INTERNATIONAL PERMEATION MEASUREMENT STANDARDS

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Measures against Incineration Problems Caused by Clogging of White Smoke Prevention Preheater

SR GreenPoxy 33 / SZ 8525 Clear epoxy system for compression moulding

Efficiency for your assembly line. Speciality lubricants for MRO in the automotive industry

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

CHAPTER 3 : TYPE I TEST ON SI ENGINES (VERIFYING THE AVERAGE EMISSIONS OF GASEOUS POLLUTANTS)

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

GLOBAL PRESSURE SOLUTIONS HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Lube & Seal for Power Transmission Engineering Enhanced and prolonged sealing with Klüber Lubrication and Simrit

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

CHAPTER-3 EXPERIMENTAL SETUP. The experimental set up is made with necessary. instrumentations to evaluate the performance, emission and

C h e m i c a l a g i n g o f c a t a l y t i c c o n v e r t e r s w i t h r e g a r d t o m e t h a n e c o n v e r s i o n

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

Emissions Theory and Diagnostics

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Correlating TBP to Simulated Distillations. COQA Long Beach, CA

2/2-way Angle-Seat Valve for high-quality cryogenic applications and steam

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Pilodist. Laboratory & process technology. Knowledge & Competence

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor

Emerging Techniques; Hyphenated Technologies for Polymer and Biofuel Application

Emission from gasoline powered vehicles are classified as 1. Exhaust emission 2. Crank case emission 3. Evaporative emission. Table 1.

SR InfuGreen 810 Green Epoxy systems for Injection and Infusion

Module 6: Chemical Resistance

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

PARAFOL C 12 C 22. High purity normal paraffins. Sasol Performance Chemicals

Hot-film Air-mass Meter HFM 6

Gas analyzers EL3060 The specialists for hazardous areas

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

Standard Classification System for Carbon Blacks Used in Rubber Products 1

FLOTTWEG SEPARATION TECHNOLOGY FOR THE PRODUCTION OF BIODIESEL

Bomb Calorimetry and Viscometry: What Properties Make a Good Fuel?

Portable Compressors MOBILAIR M 123 With the world-renowned SIGMA PROFILE Free air delivery 11.4 m³/min.

Turbomolecular Pumps TURBOVAC SL The New Premium Line

MIXPAC TM Technical Services Your partner for successful solutions. Sulzer Chemtech

Gasoline Specifications

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

SP/SMT 1 Flow Divider

11/12/2017 Erwin H. Doorenspleet

DELO -PUR 9692 Multi-purpose 2c polyurethane, cures at room temperature, high-viscous, filled

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Application Note. Abstract. Authors. Environmental Analysis

Application Note. Authors. Abstract. Energy & Chemicals

CH 6. S.S.E.R. Ltd. Registered in England & Wales. Company Registration No

X-STREAM Enhanced XEGP - General Purpose Gas Analyzer

PRODUCT INFORMATION SHEET

ABB Instrumentation. Thermal Mass Flowmeter Sensyflow. Intelligent solutions for accurate gas mass flow measurement

Rotary Blowers Omega Series Air delivery from 0.5 to 160 m³/min Pressure up to 1000 mbar, vacuum to -500 mbar

X-STREAM Enhanced XEGK - Compact Gas Analyzer

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

ANNEX 2, REFERENCE FUELS

Products Solutions Services. Customized Pressure Sensors and Components Made by Endress+Hauser

FOMLUBE - GREASES. Cleaning. Lubricants. Inert Wide Temperature PFPE Greases For Lifetime Lubrication. Fluids for precision. Lifetime and maintenance

Problem 1 (ECU Priority)

Tel: (0) Fax: (0)

ADU 5. Automatic Distillation Unit

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010. ASTM INTERNATIONAL 100 Barr Harbor Drive West Conshohocken, PA Amy Meacock

SCOPE OF ACCREDITATION

S 1125 HPLC Pump System

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Method Development for Capillary GC Systems. Slide 1

Internal Combustion Engines

FUNDAMENTAL STUDY OF LOW-NOx COMBUSTION FLY ASH UTILIZATION SEMI-ANNUAL REPORT. Reporting Period Start Date: 05/01/1998 End Date: 10/31/1998

Safety technology/equipment

COATINGS ALKYD POLYESTERS POLYOLS FOR POLYURETHANES POLYMERIC RESINS

DANI Transformer Oil Gas Analyzer

AFM 34 does not contain any physiologically harmful substances or colour pigments.

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

acc. to DIN 3535, part 6 FA VP 401 Gaskets with higher thermal resistance

Measurement Products Measurement made easy. Swirl flowmeters FS4000 Simply fitting your purpose Application guide

PF Pressure Plate Filter. Recovery of clear filtrates

ELECTRONIC ENGINE CONTROLS

Introduction of Voith Composites. Meet the Future of Carbon Fiber Composites. Germany, July voith.com. Garching, June 27, 2018

High Performance Tackifier for the Rubber Industry

C2, C3, C4 Monomer Analysis

Transcription:

Analyzing & Testing High-Pressure Differential Scanning Calorimetry Up to 15 MPa DSC 204 HP

DSC 204 HP Phoenix Highlights The versatile high-pressure DSC 204 HP Phoenix is part of our successful 200 series. This also includes the heat flux Differential scanning calorimeter DSC 204 F1 Phoenix and DSC 200 F3 Maia, the Thermomicrobalances TG 209 F1 Libra and TG 209 F3 Tarsus, the Thermomechanical analyzer TMA 402 F1/F3 Hyperion, the Dynamic mechanical analyzer DMA 242 E Artemis and the Dielectric analyzer series DEA 288 Epsilon. The DSC 204 HP Phoenix can also be operated simultaneously with hightemperature instruments of the 400 series in a multimoduling mode. Accessories Electronic pressure Electronic gas Adapters for Vacuum pump CC 200 controller flow controller various gases L for controlled cooling with liquid nitrogen Calibration kit for temperature and sensitivity 2

Technical Data Wide pressure range: vacuum... 15 MPa (2140 psi) Exact pressure adjustment Pressure accuracy ± 0,075 MPa Temperature range: -150 C to 600 C (Temperature range is pressure and gas type dependent: -150 C to 600 C (at 1 bar) -90 C to 600 C (at 50 bar) -50 C to 450 C (at 150 bar)) inert (N 2, He, Ar) Heating rates: 0.01 K/min to 100 K/min Measurements in different atmospheres reducing (H 2 ) oxidizing (O 2, air) other gas types on request Exact gas flow regulation (up to 500 ml/min) Exchangeable sensor plate Allows measurements in according with ASTM D5483, D6186, E1782, E1858, E2009 Evaluation of oxidative-induction time (OIT) included thermostat hose connection (outlet) knurled nut thermostated lid sensor thermostat hose connection (inlet) LN 2 cooling DSC 204 HP Phoenix measuring part for the connection of the LN 2 colling device 3

DSC 204 HP Phoenix Maximum Flexibility regarding Gas Types, Flow Rates and Pressures Numerous physical processes and chemical reactions are influenced by atmospheric pressure. In practice it is therefore often necessary to conduct DSC measurements under pressure. With the high-pressure DSC 204 HP Phoenix thermal effects of a sample can be analyzed in the pressure range of vacuum to 15 MPa (approx. 2176 psi) from -150 C to 600 C. The reliable CC 200 L control cooling system is available for this temperature range. Measurements in different gas atmospheres such as O 2, N 2, Ar, He, H 2, CO 2 and CH 4 are no problem in the robust measuring cell. The sample atmosphere is either static or dynamic. The electronic pressure control device as well as exact regulation of the purge gas flow are the main features for outstanding accuracy and reproducibility of the measurements. Of course, the DSC 204 HP Phoenix meets all safety requirements which are required for measurements under pressure. An array of crucibles in various sizes, shapes and materials for different applications is also available. Possible Operation Modes* Mode I Mode II Mode III Mode IV Mode V Measurement under static gas atmosphere with defined gas pressure (up to 15 MPa) Measurement under dynamic gas atmosphere with defined pressure and defined gas flow Use of an inert gas (e.g. Ar) to establish a defined pressure and measurement under dynamic reaction gas atmosphere (e.g. O 2 at 100 ml/min) Measurement in static or dynamic gas mixture Measurement under adjustable reduced pressure * Depending on pressure device 4

Wide-Ranging Applications Determination of vapor pressure and evaporation heat (ASTM E1782) Separation of reactions with overlapped evaporation Measurement of adsorption and desorption, e.g. on metallic compounds Oxidation stability of oils, fats and lubricants (ASTM E1858, ASTM D6186, ASTM E2009, ASTM D5483) Curing of thermosets, e.g. phenolic resin Vulcanization of elastomers Hydration of unsaturated fatty acids DSC measurements under ambient pressure can, of course, also be conducted with the DSC 204 HP Phoenix and even under reduced pressure 5

Wide-ranging Applications Versatile High-Pressure DSC Synetic Oil Oxidation behavior of a stabilized synthetic oil (sample mass 3.0 + 0.1 mg) at 2 C/min in oxygen (100 ml/min) at defined pressures. With increasing oxygen pressure, oxidation starts earlier, i.e. at a lower temperature. Precise Pressure Control Precision of the Pressure Control: the pressure variations detected during the measurement (+ 0.002 MPa/ + 0.02 bar) are 100 times smaller than is prescribed by ASTM D6186, influences of the pressure on the DSC signal (e.g. noise) can therefore be minimized. DSC / mw/mg 1.5 1.0 0.5 0 tolerated pressure deviation according to ASTM 6186-98 +/- 0.2 MPa +/- 2 bar measured pressure deviation +/- 0.002 MPa +/- 0.02 bar Fläche: 34.12 J/g Peak*: 239.2 C Onset: 230.8 C 100 120 140 160 180 200 220 240 260 Temperature / C pressure / bar 102.00 101.50 101.00 100.50 100.00 99.50 99.00 98.50 98.00 6

Curing Behavior of Phenolic Resins lot A lot B Partial area evaluation of the curing peak of two phenolic resin lots (A, B) at a practical pressure of 9 MPa in an inert gas atmosphere at 10 C/min (sample mass 10.5 mg, heating rate 10 C/min). Hydration of a Metal Catalyst Exothermal hydration of a metal catalyst at 7 MPa in a pure hydrogen atmosphere (sample mass 6.09 mg, heating rate 10 C/min). 7

The NETZSCH Group is a mid-sized, family-owned German company engaging in the manufacture of machinery and instrumentation with worldwide production, sales, and service branches. The three Business Units Analyzing & Testing, Grinding & Dispersing and Pumps & Systems provide tailored solutions for highest-level needs. Over 3,000 employees at 210 sales and production centers in 35 countries across the globe guarantee that expert service is never far from our customers. When it comes to Thermal Analysis, Calorimetry (adiabatic & reaction) and the determination of Thermophysical Properties, NETZSCH has it covered. Our 50 years of applications experience, broad state-of-the-art product line and comprehensive service offerings ensure that our solutions will not only meet your every requirement but also exceed your every expectation. NETZSCH-Gerätebau GmbH Wittelsbacherstraße 42 95100 Selb Germany Tel.: +49 9287 881-0 Fax: +49 9287 881 505 at@netzsch.com NGB DSC 204 HP Phoenix EN 0815 NWS Technical specifications are subject to change.