ALLROUNDER 270 A. Distance between tie bars: 270 x 270 mm Clamping force: 350 kn Injection unit (acc. to EUROMAP): 5, 70, 100.

Similar documents
ALLROUNDER 570 H. Distance between tie bars: 570 x 570 mm Clamping force: 2000 kn Injection unit (acc. to EUROMAP): 400, 800, 1300.

ALLROUNDER 630 A. Distance between tie bars: 630 x 630 mm Clamping force: 2500 kn Injection unit (acc. to EUROMAP): 800, 1300, 2100.

ALLROUNDER 370 E. Distance between tie bars: 370 x 370 mm Clamping force: 600 kn Injection unit (acc. to EUROMAP): 170, 290.

ALLROUNDER 520 E. Distance between tie bars: 520 x 520 mm Clamping force: 1500 kn Injection unit (acc. to EUROMAP): 290, 400, 800.

ALLROUNDER 630 H. Distance between tie bars: 630 x 630 mm Clamping force: 2500 kn Injection unit (acc. to EUROMAP): 800, 1300, 2100.

ALLROUNDER 720 A Multi-component

ALLROUNDER 570 C GOLDEN EDITION

ALLROUNDER 270 C GOLDEN EDITION

ALLROUNDER 720 H. Distance between tie bars: 720 x 720 mm Clamping force: 3200 kn Injection unit (according to EUROMAP): 1300, 2100, 3200

ALLROUNDER 520 A multi-component

820 S. Machine dimensions. Electrical connection. Cooling water connection 850 6) 878 7) 960 5) 113/438 4) ) ) ) )6) )

ALLROUNDER 470 S. Distance between tie bars: 470 x 470 mm Clamping force: 800, 1000, 1100 kn Injection unit (acc. to EUROMAP): 170, 290, 400

ALLROUNDER 520 S. Distance between tie bars: 520 x 520 mm Clamping force: 1300, 1500, 1600 kn Injection unit (acc. to EUROMAP): 290, 400, 800

ALLROUNDER 630 S. Distance between tie bars: 630 x 630 mm Clamping force: 2500 kn Injection unit (acc. to EUROMAP): 800, 1300, 2100.

ALLROUNDER 720 S Multi-component

ALLROUNDER 820 S Multi-component

ALLROUNDER 470 S Multi-component

ALLROUNDER CUBE 2900

Facts and figures ALLROUNDER 375 V. Vertical free-space system Clamping force: 500 kn Injection unit (acc. to EUROMAP): 100, 170, 290.

Facts and figures ALLROUNDER 275 V. Vertical free-space system Clamping force: 250 kn Injection unit (according to EUROMAP): 70, 100.

ALLROUNDER 520 A. Distance between tie bars: x (520 x 520 mm) Clamping force: 165 tons Injection unit: 6.1 oz, 8.2 oz, 15.

ALLROUNDER 470 A. Distance between tie bars: 470 x 470 mm Clamping force: 1000 kn Injection unit (acc. to EUROMAP): 170, 290, 400

ALLROUNDER 520 H. Distance between tie bars: 520 x 520 mm Clamping force: 1500 kn Injection unit (acc. to EUROMAP): 290, 400, 800

ALLROUNDER 570 E. Distance between tie bars: 570 x 570 mm Clamping force: 2000 kn Injection unit (acc. to EUROMAP): 400, 800

ALLROUNDER 920 A. Distance between tie bars: 920 x 920 mm Clamping force: 4600, 5000 kn Injection unit (acc. to EUROMAP): 1300, 2100

ALLROUNDER 820 A. Distance between tie bars: 820 x 820 mm Clamping force: 3700, 4000 kn Injection unit (acc. to EUROMAP): 1300, 2100

ALLROUNDER 320 C GOLDEN EDITION

ALLROUNDER 920 S. Distance between tie bars: 920 x 920 mm Clamping force: 5000 kn Injection unit (acc. to EUROMAP): 2100, 3200, 4600

ALLROUNDER 570 S. Distance between tie bars: x (570 x 570 mm) Clamping force: 176, 220, 242 tons Injection unit: 8.2 oz, 15.3 oz, 29.

ALLROUNDER 270 S. Distance between tie bars: x (270 x 270 mm) Clamping force: 28, 38, 44 tons Injection unit: 1.4 oz, 2.3 oz, 3.

Facts and figures ALLROUNDER 1500 T

ALLROUNDER 170 S. Distance between tie bars: 170 x 170 mm Clamping force: 125, 150, 180 kn Injection unit (acc. to EUROMAP): 30, 70

ALLROUNDER 570 A. Distance between tie bars: x (570 x 570 mm) Clamping force: 220 tons Injection unit: 8.2 oz, 15.3 oz, 29.

ALLROUNDER 520 E. Distance between tie bars: x (520 x 520 mm) Clamping force: 165 tons Injection unit: 6.1 oz, 8.2 oz, 15.

ALLROUNDER 470 E. Distance between tie bars: 18.5 x 18.5 (470 x 470 mm) Clamping force: 110 tons Injection unit: 3.7 oz, 6.1 oz, 8.

ALLROUNDER 275 V. Vertical free-space system Clamping force: 28 tons Injection unit: 1.4 oz, 2.3 oz

ALLROUNDER 1800 T. Table diameter: 1800 mm Clamping force: 2000, 2500, 3200 kn Injection unit (acc. to EUROMAP): 400, 800, 1300, 2100

Facts and figures INTEGRALPICKER V.

ALLROUNDER 520 A. Tie bar distances: 520 x 520 mm Clamping forces: 1300, 1500 kn Injection units (according to EUROMAP): 400, 800.

ALLROUNDER 470 A multi-component

A S GOLDEN EDITION V T C ALLROUNDER 270/320 C. Technical Data

ALLROUNDER 270 S Tie bar distance: 270 x 270 mm Clamping forces: 250, 350, 400 kn Injection units (according to EUROMAP): 70, 100, 170

Facts and figures MULTILIFT V 6

Facts and figures MULTILIFT SELECT 6

ALLROUNDER 1200 T. Table diameter: 1200 mm Clamping force: 800, 1000, 1600, 2000 kn Injection unit (acc. to EUROMAP): 70, 100, 170, 290, 400, 800

Hydraulic ALLROUNDERs

Focus. Electric ALLROUNDERs. Injection moulding machines for complex part production.

Technical Data Concept and System 25/280

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

Technical Data Injection Moulding Machines Series CX PET Light

Global Dialysis - Cost per Dialysis Session

BP Statistical Review of World Energy June 2017

Rectangular photoelectric proximity switches

Fork through-beam sensors

DOUBLE OCTOMILL TM PRODUCT RANGE

Fork through-beam sensors

WÜRTH Industrie Service WÜPLAST. Screws for thermoplastics

DIAPHRAGM PRESSURE CYLINDERS

Primary energy. 8 Consumption 9 Consumption by fuel. 67 th edition

Infographics on Electromobility (January 2019)

MacroPower MC t The flexible large-molding machine. world of innovation

Packing Data Installation Instructions

2. The quantifiable attributes

NI PS-15/16/17 Side Mount Brackets

WÜRTH Industrie Service DE EN WÜPLAST. Screws for thermoplastics

Extraction arms for every type of application

Global Polybutadiene Rubber (BR) Market Study ( )

Lifting Instructions for 1336 PLUS and FORCE D Frame Drives

Annex IV. True nationality of the 20 largest fleets by flag of registration, as at 1 January 2011 a

Spritzgiessautomaten. Innovative into the future. Data and Equipment

SM Series. High Pressure - All-Metal Flowmeter and Switch

Performance Derby: MSCI Regions/Countries Earnings & Revenues Growth 2019E / 2018E / 2017A

NCP/NCB/NCS. Magnetic Float Switches. for Liquids

45mm. Electric Specifications Input Power Source 230 VAC +/- 10% 3Ph 60Hz Std. Power. Machine kva 35 Supply

Global Valuation Summary - SAMPLE PAGES

Made UNDER high pressure

CrimpTest-1 kn. Calibration Bracket

MMA. Insertion Resistance Thermometers. with, or without transmitter. OEconomically-priced O thermometers with optional plug-on display

M O T O R V E H I C L E S T A T I S T l C S

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

1. INTERNATIONAL OVERVIEW. 1.0 Area and population. population (1,000) area

testing to perfection MultiTest-i Technical Datasheet

testing to perfection MultiTest-i Technical Datasheet

FEDERAL RESERVE statistical release

-Shape the Future with Manufacturing Technology

Multi Function Efficient Dynamic Altitude Simulation MEDAS

Chit Chats clients save up to 70% on U.S. and international postage.

Potential Danger of Fire or Explosion Read this letter now!

The new STx chain hoist NEW. Sophisticated technology prepared for the future

Selection Guide for P Series Pump Accessories & Options

67 th edition. Renewable energy. Appendices. 44 Other renewables consumption 45 Biofuels production

D6.. Butterfly valves. For controlled operation.

Production of minor oil products from refineries - by type Thousand metric tons

Imports of seed for sowing by country Calendar year 2011 Source: ISF compilation based on official statistics and international seed trade reports

Table 23 Production of minor oil products from refineries - by type Thousand metric tons

UXC.COM A PUBLICATION OF. NPO Overview 1501 MACY DRIVE ROSWELL, GA PH FX

REVIEW OF MARITIME TRANSPORT 2013

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

Global Medium & Heavy Commercial Vehicle Model Level Production Forecast Report. From 2001 to 2021

Transcription:

Facts and figures ALLROUNDER 27 A Distance between tie bars: 27 x 27 mm Clamping force: 35 kn Injection unit (acc. to EUROMAP): 5, 7, 1 www.arburg.com

27 A Machine dimensions 238 122 12 425 254 438 191 1968 1) 1957 2) 5 256 47 12 44 min. 196 max. 387 2763 387 416 5 3354 352 1) 3273 2) 3488 3) 645 1184 954 237 3) Electrical connection Cooling water connection 1) Injection unit 5 2) Injection unit 7 3) Injection unit 1 2

Technical data 27 A Clamping unit with clamping force max. kn 27 A 35 Opening force stroke max. kn mm - 2 Mould height, fixed variable min.-max. mm - 15-35 Platen daylight fixed variable max. mm - 35-55 Distance between tie bars (w x h) mm 27 x 27 Mould mounting platens (w x h) max. mm 38 x 38 Weight of movable mould half max. kg 2 Ejector force stroke max. kn mm 16 6 Dry cycle time EUROMAP ² Version L1 min. s - mm 1,2-189 Version L2 min. s - mm,7-189 Injection unit with screw diameter mm 5 8 18 7 22 25 2 1 25 3 Effective screw length L/D 12 24,5 2 17,5 25 2 16,7 Screw stroke max. mm 5 9 1 Calculated stroke volume max. cm³ 2,5 23 34 44 31 49 71 Shot weight max. g PS 2,3 21 31 4 29 45 65 Material throughput max. kg/h PS 1 4,1 5,5 6,5 5,5 8 9,5 max. kg/h PA6.6,5 2,1 2,8 3,3 2,8 4 4,9 Injection pressure max. bar 2 25 2 155 25 2 139 Holding pressure max. bar 16 239 16 124 25 16 111 Injection flow ² Version L1 max. cm³/s - 51 76 98 64 1 144 Version L2 max. cm³/s 25 76 114 147 94 148 214 Screw circumferential speed ² max. m/min 9 45 55 63 4 5 6 Screw torque max. Nm 12 9 11 12 12 21 25 Nozzle contact force retraction stroke max. kn mm 5 15 5 23 5 23 Heating capacity zones kw 1,9 5 4,1 4 4,9 5 Feed hopper l 1,8 25 5 Drive and connection with injection unit Version L1 7 1 5 Version L2 7 1 Net weight of machine kg 235 249 23 235 249 Sound press. level Insecurity ⁴ db(a) 63 3 63 3 Electrical connection ³ kw 11 13 13 16 18 Total A 4 5 5 5 63 Machine A - - Heating A - - Cooling water connection max. C 3 3 min. Δp bar 1,5 DN 25 1,5 DN 25 Machine type with EUROMAP size designation ¹ Drive 27 A 35-5 - L2 27 A 35-7 1 L1 L2 Upon request: other machine types and mould installation heights, screws, drive powers etc. All specifications relate to the basic machine version. Deviations are possible depending on variants, process settings and material type. Depending on the drive, certain combinations, e.g. max. injection pressure and max. injection flow may be mutually exclusive. 1) Clamping force (kn) - large injection unit = max. stroke volume (cm³) x max. injection pressure (kbar) 2) Specifications depend on the drive variant / drive configuration. 3) Specifications relate to 4 V/5 Hz. 4) Emission sound pressure level at the workplace. Detailed information in the operating instructions. [ ] Specifications apply to alternative equipment. 3

27 A Mould installation dimensions, variant L1 / L2 Stroke max. 6 142-1 Ø125H7 Ø6H7 1) C X Y 25 a max. Injection unit A B a Standard Thermoset 5 7/1 5 4-2 Stroke max. 2 max. 35-55 Ejector bolt X Bore in mould (if required) Y Ø18-,1 Ø13 3 28,5 3 Ø18 Ø8 2) Ø9 3) Ø4 1) Ø5 2) Ø6 3) 55 8-,1 2 2)3) 21 Injection unit 5 1) / 7 2) / 1 3) 18 Closing force for spring moulds / during injection compression moulding* 3 Robotic system mounting C 52,5 Closing force [kn] 25 2 15 1 5 5 1 15 2 42 37 28 17,5 15 1 M8-16 deep 52 Mould stroke [mm] 65 * automatic locking force adjustment up to 2 kn 1) Optional with size 5 injection unit M12-24 deep 4

Mould installation dimensions, variant L1 / L2 27 A Fixed mould mounting platen A 45 45 35 28 21 14 7 Ø125H7 Ø6H7 1) Ø17 311,5 516,5 Bores for ARBURG mechanical mould rapid clamping system 7 14 21 Ø14 M12-24 deep 28 35 Moving mould mounting platen B 55 M8-16 deep 249 269 17 W 315 27 Ø45 Ø21 17 419 538,5 18 356,5 27 52 M8-16 deep 315 44 41 43 1) Optional with size 5 injection unit 5

27 A Shot weights Theoretical shot weights for the most important injection moulding materials Injection units according to EUROMAP Screw diameter mm Polystyrene max. g PS Styrene heteropolymerizates max. g SB max. g SAN, ABS 1) Cellulose acetate max. g CA 1) Celluloseacetobutyrate max. g CAB 1) Polymethyl methacrylate max. g PMMA Polyphenylene ether, mod. max. g PPE Polycarbonate max. g PC Polysulphone max. g PSU Polyamides max. g PA 6.6 PA 6 1) max. g PA 6.1 PA 11 1) Polyoximethylene (Polyacetal) max. g POM Polyethylene terephthalate max. g PET Polyethylene max. g PE-LD max. g PE-HD Polypropylene max. g PP Fluorpolymerides max. g FEP, PFA, PCTFE 1) max. g ETFE Polyvinyl chloride max. g PVC-U max. g PVC-P 1) 5 8 2,3 2,2 2,2 2,6 2,4 2,4 2,1 2,4 2,5 2,3 2,2 2,1 2,8 2,7 1,7 1,8 1,8 7 18 22 25 21 31 4 2 31 39 2 3 39 24 35 45 22 33 42 22 32 42 19 29 37 22 33 42 23 34 44 21 31 4 19 29 37 26 39 5 25 37 48 16 24 3 16 24 31 17 25 32 33 5 65 29 44 57 25 38 49 23 35 45 1 2 25 3 29 45 65 28 44 63 27 43 62 32 5 73 3 47 68 3 46 67 27 42 6 3 47 68 31 49 7 28 44 64 26 41 6 35 55 8 34 53 77 22 34 49 22 35 5 23 36 51 46 72 13 4 63 91 35 54 78 32 5 72 1) average value 2) Normal working range for the size 5 injection unit is less than/greater than 5% of the specified values. PVC-P, PVC-U and fluoropolymers are not approved. ARBURG GmbH + Co KG Arthur-Hehl-Strasse 7229 Lossburg Tel.: +49 7446 33- www.arburg.com contact@arburg.com With locations in Europe: Germany, Belgium, Denmark, France, United Kingdom, Italy, Netherlands, Austria, Poland, Switzerland, Slovakia, Spain, Czech Republic, Turkey, Hungary Asia: People s Republic of China, Indonesia, Malaysia, Singapore, Taiwan, Thailand, United Arab Emirates America: Brazil, Mexico, USA For more information, please go to www.arburg.com. 218 ARBURG GmbH + Co KG The brochure is protected by copyright. Any utilisation, which is not expressly permitted under copyright legislation, requires the previous approval of ARBURG. All data and technical information have been compiled with great care. However we accept no responsibility for correctness. Individual illustrations and information may deviate from the actual delivery condition of the machine. The relevant valid operating instructions are applicable for the installation and operation of the machine. ARBURG GmbH + Co KG DIN EN ISO 91 + 141 + 51 certified 68293_EN_GB_4218 Subject to alterations