India Centric Standards and LED Products and R&D for Product Test

Similar documents
GTB Working Group Light Sources

The International Automotive Lighting and Light Signalling Expert Group

Electric Vehicles Safety Global Technical Regulation

Off-grid lighting testing and certification processes. Pradeep Kumar

PROMOTING THE UPTAKE OF ELECTRIC AND OTHER LOW EMISSION VEHICLES

(Initial issue) CS-34

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

VIETNAM NATIONAL STANDARDS AND LABELING REQUIREMENTS

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

MEASUREMENT AND TEST REPORT

LIGHT EFFICIENT DESIGN

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

Update on IEC Standards. Owen Manley Technical Manager, Lighting Council Australia 6 June 2011, Sydney

LIGHT EFFICIENT DESIGN, LLC

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

CMMI Opens the Gate: The Practical Relationship between CMMI and Stage- Gate Decision Models

Electric Vehicles and the Environment (EVE IWG)

Photometric Test Report

Stationary Battery Safety An Overview of the Process of Verifying the Safety of Battery Systems

T5 Watt-Miser Linear Fluorescent lamps

Towards Sustainable Consumption and Production: Energy Efficiency Labeling in India

Lessons Learned in Lighting Equipment Testing in the Philippines

Accelerated Life Testing Final Report

Indicativul și titlul standardului doc.

AGREEMENT between the UNITED STATES OF AMERICA and the EUROPEAN COMMUNITY on Cooperation in the Regulation of Civil Aviation Safety

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

HEV, EV, Diesel Technology ; Indian trends and Role of Government for supporting

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260

THE HEARTBEAT B E H I N D T H E HEARTBEAT MEDICAL POWER BROCHURE

Waste Stream Li-ion Battery Sorting Issues

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Status Report of the VIAQ (Vehicle Interior Air Quality) Informal Working Group

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

Climate Innovation Centres: role & expectations of business Preeti Malhotra, Power & Environmental Policies, Alstom

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE:

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

UNCLASSIFIED FY 2017 OCO. FY 2017 Base

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, ,

Technical information MINI NICOLE, NICOLE & MAXI NICOLE LUMINAIRES

TECHNICAL REPORT TYPE 3

Smarter Solutions for a Clean Energy Future

IEEE SCC21 Overview/Status IEEE Standards Coordinating Committee 21 on Fuel cells, Photovoltaics. Dispersed Generation, and Energy Storage

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

The challenges of the electricity market, a challenge for Africa

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Efficient Risk Assessment for ships using Low Flash Point Fuel

Method Implementation Document (MID)

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Economic and Social Council

The starting point: History of the VW defeat device scandal and lessons learned

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Low voltage motors for hazardous areas Safe, reliable and highly efficient

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS

Requirements for Alteration Design Registration Based on Fitness-for-Service

G20 TRANSPORT TASK GROUP 2018 UPDATE FIRST IN-PERSON MEETING SEPTEMBER 25, 2018 DIANA GALPERIN AND JOSH MILLER

Status Report of the VIAQ (Vehicle Interior Air Quality) Informal Working Group

Technical Information

Compatibility of STPA with GM System Safety Engineering Process. Padma Sundaram Dave Hartfelder

BWM CONVENTION: OBJECTIVES, STRATEGIES, AND ACTIONS

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

Realigning the Pacific Humanitarian Team Approach. Pacific Humanitarian Partnership Meeting Thursday 20 October 2016

E-mobility Indian Roadmap Perspective. A B KOMAWAR The Automotive Research Association of India

POLLUTION PREVENTION AND RESPONSE. Application of more than one engine operational profile ("multi-map") under the NOx Technical Code 2008

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

Start Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K

INDEPENDENT TEST LABORATORY REPORT No

CMP266 Removal of Demand TNUoS charging as a barrier to future elective Half Hourly settlement

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

T8 4ft 5000K EazyLux EZ8450D7R07

INDEPENDENT TEST LABORATORY REPORT No A

SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M

EU RO Mutual Recognition Technical Requirements

High-density LED modules that sell

O B J E C T I V E NON-kind-Projects

CHAPTER 4 Motor Load factor Survey

EU initiative for CO2 emissions reduction in Europe

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG

Fuel Economy Policy Pathways for the ASEAN Region

Increasing Motorization in Asia

Biax D and D/E. GE Lighting DATA SHEE T. Compact Fluorescent Lamps Non-Integrated 10W, 13W, 18W and 26W

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

Electrical Systems and Fault Finding

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

Experience bright and vivid colors

Transcription:

India Centric Standards and LED Products and R&D for Product Test BRICS Cooperative Activities 4 th Meeting of BRICS Solid State Lighting Collaboration Working Group Hangzhou, China (19-24 June, 2017) Organizer: Secretariat of BRICS SSL WG Presented By : Gautam Brahmbhatt ERDA, India Date : 19 th June 2017

Agenda Back Ground Indian Standards Critical Components Research Project Details Researchers Team Way forward Research Plan Summary

Background LED lamps are energy saving,long life and widely used as the next generation lighting. Promotion of energy efficient and environmentally safe lighting by Government ( Prime Minister Narendra Inaugurated Prakash Path way to light, and UJALA Scheme by EESL) Reliability assessment and Lifetime prediction for LED lamps has gained significant research interest in implementing of green Lighting. Indian standards are harmonize w.r.t IEC standards. India is a developing country and conditions are different than developed country like High temperature, Humidity dust, voltage variation etc hence its important to proposed project is a joint cooperative research project focusing India conditions w.r.t development of reliability assessment

Self ballasted LED lamp Safety Requirement IEC/EN 62560 Safety requirements IS:16102-1 Safety requirements Performance Requirement IEC/PAS 62612 Performance requirements IS 16102-2 Performance requirements

Luminaire Safety Luminaires IEC 60598-1 Ed. 7.0 General requirements and tests All relevant parts 2 of IEC Particular requirements IS: 10322-1,2, 3 and 4 General requirements and tests All relevant section of part 5 of IS Particular requirements Luminaire Performance IEC/PAS 62722-1 Ed. 1.0 General requirements IEC/PAS 62722-2-1 Ed. 1.0 Particular requirements for LED luminaires IS 16107-1 General requirements IS 16107-2 Sec 1 Particular requirements for LED luminaires

Controlgears Controlgear Safety IEC 61347-1 Ed. 2.0 General and safety requirements All relevant parts 2 Particular requirements IS: 15885-1 General and safety requirements All relevant parts 2 Particular requirements Controlgear Performance IEC/EN 62384 Performance requirements LED control gear IS 16104 Performance requirements LED control gear

Photobiological safety Photobiological Safety IEC 62471 Ed. 1.0 Photobiological safety of lamps and lamp system IS 16108 Photobiological safety of lamps and lamp system IEC/TR 62471-2 Ed. 1.0 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety IEC/TR 62778 Ed. 1.0 Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires 7

Mandatory BIS CRS for Lighting Products Self - Ballasted LED Lamps for General Lighting Services (IS 16102-1):2012 Fixed General Purpose LED Luminaires including Fancy Lights (IS 10322 Part5/Sec1):2012 DC or AC Supplied Electronic Control Gear for LED Modules (IS 15885 Part 5/Sec 13): 2012

Critical Components LED Module Control Gear Optics Thermal management

Proposed Research Project Details Scope : Perform fundamental work on the reliability tests as per ISA recommended procedure. Sample Size: Accelerating temperature:

Research Project Details Monitor and record the life, depreciation in lumen and colour shift. Apply FMEA on the failed samples used in local condition. Enumerate the major failure modes to cause reliability failure of the LED lamps and investigate the root causes. Proposed Project Duration : 1 Years

Researcher Team Name Organization Title Degree Specialty ( Leader ) Shyam Sujan Electric Lamp and component Manufacture Association of India (ELCOMA) Secretary General B.Sc. Lighting Device Research (Researcher) Gautam Brahmbhatt Electrical Research and Development Association (ERDA) Group Head M.E- Electrical Power Engg. Lighting Research, Certification and Testing (Researcher) Bhavana Kasturia LEDVANCE Asst. VP Quality Master Of Engineering ( Digital Techniques & Instrumentati on) Lighting Device Research

Integrating SPhere

Type C Goniophotometer

Environmental Chambers The special features of Environmental & Humidity chambers 1. Temperature range : -60⁰C to +150⁰C 4. Humidity range : 20% RH to 95% RH 2. Accuracy for temperature : ± 1⁰C 5. Accuracy of Relative Humidity : ± 2% 3. Temperature gradient : 100⁰C/h for 25⁰C to 85⁰C 6. Temperature gradient : 200⁰C/h for 0⁰C to - 40⁰C

Way Forward Research Plan Identifying, Selecting, and availability of samples for research. Prepare details project proposal (Include Project Plan, Methodology, Project cost, Project Timeline, funding agency, Identifying roles and responsibilities of research team, Recording formats and Report Formats etc) Feedback form ISA Experts, BRICS Countries.

Summary The LED technology has developed intensely over the last few years and the subject of intense research and development. LED lamps are of greater significance in the context of need for electrical energy conservation, longer life, pollution control world over. With every passing day market is flooded with number of innovative LED luminaire. For good lighting design it is important to have right amount of light in right direction and in right colour. Compliance of products to reliability and life requirements is very important. This research project will evaluate Accelerated Ageing Test Method.