Hydro-Flow Model 3100

Similar documents
Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2200 Installation and Operation Guide B

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2300 Installation and Operation Guide B

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

Low Profile Insertion Vortex

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Hot Tap Insertion Vortex

Vortex Eggs Delta Flowmeter

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

Model FVP General Specification. Flanged Vortex Plate. Product Features

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

Armstrong In-Line and Insertion Vortex Flow Meters

Vortex In Line Flow Meter

VORTEX IN-LINE FLOW METERS

Transmitting Transducer. Gas/Air Velocity Range:

VIM20 Vortex Insertion Flowmeter

Vortex In Line Flow Meter

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Vortex Plate. Model VP General Specification. Product Features

VIM20 Vortex Insertion Flowmeter

SIGNET 7002 Vortex Flow Sensor ENGLISH

F-2600 SERIES INLINE VORTEX FLOW METER

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

VLM20 In-line Vortex Flowmeter

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

VIM20 Vortex Insertion Flowmeter

Model 5000 Vortex Meter

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

Model 1000 Vortex Meter

1100 Series Piston Type Differential Pressure Gauges

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual

Instructions EM 101 Low Flow Electromagnetic Flow Meters

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

MS Application. Features. Proportional Valve Actuator General Instructions

imag 4700 SERIES FLANGED MAGMETER

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Appendix. Clearance. Skewed profiles. Application Schematics

GE Sensing. PanaFlow MV. Vortex Flowmeter. User s Manual

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Signet 7000/7001 Vortex Flow Sensors * *

mass flowmeter for compressed air

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

flow measurement solutions RIM10 series rotor insertion flowmeters

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

TX 115/215 Hot-tap Insertion Turbine Instructions

F-1500 SERIES INSERTION TURBINE FLOW METER

Model DFX Doppler ultrasonic flow meter

UTM10 Series Ultrasonic Transit-time Flowmeters

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Chapter Page. 1 Introduction Description 1

TURBINE FLOW METER SELECTION GUIDE

UniMag DT Series Electromagnetic Flow Tubes

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

RIM20 Rotor Insertion Flowmeter

SIGNET Vortex Flow Sensors ENGLISH

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

F-2600 SERIES INLINE VORTEX FLOW METER

LTX RF LEVEL SENSOR. Instruction Manual

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

mass flowmeter for compressed air

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

220 Series Innova-Flo o

F-2500 SERIES VORTEX METER

TX115/215 Hot-tap Insertion Turbine Instructions

Model 550 Series Vibration Switches

ISTEC MAGNETIC METERS

The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor

Product Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY

The readings you need, right where you need them. AX Series Vortex Meters

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Signet 2517 Brass Paddlewheel Flow Sensor * *

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

INTERNATIONAL METAL ENGINEERING

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

F-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide

F111.X Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description.

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Low Pressure Sensor. Overview. Specifications. Installation and Operation

SAX Electronic Valve Actuator

Multivariable Vortex Flow Meter

Instruction Manual Vortex Flow Meter DVH / DVE

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

A Member of the. Integrated Metering Technologies

INSERTION flow sensor for continuous flow measurement

AEL6 Series Smart Electric Actuators for ½" to 4" Control Valves

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-4800 BBS-4800E

Transcription:

Hydro-Flow Model 3100 Installation and Operation Guide installation and operation guide Contents: Understanding Your Flow Meter... 1 Identifying Your Flow Meter...2 Installing Your Flow Meter...3,4 Making Electrical Connections...6 Mechanical and Electrical Specifications...7 Understanding Vortex Flow Meters Vortex shedding flow meters measure flow by detecting the frequency at which vortices are alternately shed from a bluff body. The vortices create low and high pressure zones behind the bluff body which are detected as a force acting on the sensor wing. This force is transmitted through the sensor wing to the Hydro-Flow piezo-resistive sensor mounted inside the flow line. Hydro-Flow's unique and proprietary microprocessor-based piezo-resistive sensor can accurately and reliably process vortex signals 25 times smaller than permitted by other technologies. According to physical laws, the shedding frequency is directly proportional to the average flow velocity. This effect can be observed in the fluttering of a flag. Vortex flow meters are preferred for many applications requiring wide flow range, accuracy, and reliability (no moving parts). Handling Your Flow Meter Even though the flow meter is one of the most rugged in the industry, exercise reasonable care with the flow meter. When not installed, store the flow meter with the installation manual in its shipping container. Do not ram or poke objects into the meter bore or onto the sensor wing/shedder. Hydro-Flow is a no moving parts flow meter. If you push hard enough to see a part move, the flow meter is probably damaged. Pay particular attention to the direction of flow. The flow must impact the surface of the stainless steel shedder. The direction of the flow is clearly indicated on the flow meter electronics. The flow meter will not work if you install it backwards. The flow meter's installation location is important for optimum performance accuracy; a quick review of Installing Your Flow Meter on page 3 will be helpful.

hydro-flow model 3100 retractable insertion flow meter Identifying Your Flow Meter An identification plate (ID) is attached to your flow meter. For model code information, see Hydro-Flow Model and Suffix Codes on page 2. 1200-xx-x-x-x-x Figure 1. Flow meter identification (ID) plate Hydro-Flow Model and Suffix Codes Table 1. Hydro-Flow model and suffix code identification table Category Suffix Codes Type Retractable insertion 3100 Line Size 3" (80 mm) 03 through to 20" (500 mm) 20 Mounting Thread-o-let 1 Saddle for steel pipe 2 Output Pulse 1 Current: 4 ma to 20 ma 2 No output 3 Display No Display 1 Rate/Total Display 2 Measuring Units English 1 Metric 2 Example (3100-12-1-2-2-2): 3100 12 1 2 2 2 A 12" retractable insertion flow meter with thread-o-let mounting, 4mA to 20mA analog output, and rate/total display in metric units. Ordering Considerations When ordering, please specify pipe size, material, and schedule (or outside and inside diameter of pipe). Standard English measuring units are gallons per minute (gpm) and gallons. Standard metric measuring units are cubic meters per hour (m3/hr) and cubic meters (m3). Please specify other desired measuring units for which the flow meter should be configured. Other units, such as acres, cubic feet, barrels, and liters are available and can be set by the factory. 2

installation and operation guide Installing Your Flow Meter Upon receiving your Hydro-Flow equipment, verify that all materials on the packing list are present. Check for possible shipping damage and notify the freight carrier or your Hydro-Flow representative if there is any damage. Before installing your flow meter, verify that the model is consistent with your requirements. See Hydro-Flow Model and Suffix Codes on page 2 for identification information. Selecting the Best Flow Meter Location For optimum performance, you must consider straight run requirements and flow meter installation location relative to flow direction. Figure 2 illustrates possible flow meter locations. The good flow meter locations are recommended to ensure that the pipe and the flow meter will always be filled with fluid. Note: Consult the factory if you have special requirements. Straight Run Requirements The straight run of the pipe must have the same nominal diameter (D) as the flow meter body. Figure 2 illustrates the minimum requirements for straight run piping. Bad Bad h h>0 h h>0 Bad Figure 2. Flow meter location illustrations and straight run requirements 3

hydro-flow model 3100 retractable insertion flow meter Mechanical Drawing: Model 3100 Thread-o-let Installation Caution: Line must be depressurized if wet tap is not performed. Condulet To Mount the Flow Meter in a Threado-let Installation: 1. Drill or bore and deburr a 1.875" diameter hole in pipe. Use a 1-7/8" hole saw. Note: Flame cutting is discouraged. 2. The hole should not be blocked. Center the 2" thread-o-let over hole (see Figure 4). Figure 3. Hydro-Flow Model 3100 flow meter with detail of condulet Mechanical Installation General mechanical installation information: The Hydro-Flow model 3100 retractable insertion flow meter allows for installation without the need to depressurize the pipeline. The retractor serves to position the vortex flow sensor in the pipe. When the retractor is used with an isolation valve, it is wet tap compatible. The retractor is a non-rising stem type, thus providing maximum installation ease and operator safety. Note: Manual force to push the flow sensor into the pipe is not required. Figure 4. Thread-o-let hardware installation 3. Weld the thread-o-let on the pipe using standard trade practices. Trade practices may vary by locality.welding should be done by an experienced certified welder. 4. Attach flow meter to isolation valve. 5. Fully open isolation valve. Caution: Failure to fully open valve prior to installation will cause irreparable damage to the flow sensor. A bold, very visible warning sign is recommended to alert operator. Wet Tapping Flow meter is supplied with a 2" thread-o-let. A 1.875" hole opening is required. Caution: Local State regulation often require a wet tap permit. The manufacturers of the wet tap equipment and/or the contractors performing the contract are responsible for providing the proof of such a permit. 6. Turn crank clockwise to insert the flow sensor into the pipe. Do so until the calculated scale reading lines up with the arrow on the retractor bar assembly. Caution: Do not force sensor into pipe if the mechanical resistance suddenly increases this condition generally indicates the pipe tap is too small. 4

installation and operation guide Calculating the Proper Scale Reading For all pipe sizes, the proper scale reading is equal to the distance from the top of the pipe to the bottom of the aluminum plate at the bottom of the scale (see Figure 5). This measurement equals "A". Note: Use the scale on the left for pipe sizes 6" and smaller. Use the scale on the right for pipe sizes 8" and larger. Saddle Clamp Installation Caution: Line must be depressurized if wet tap is not performed. Figure 5. Scale depth tool The scale on the retractor indicates the position of the flow sensor axis to within 0.05 inches with respect to the reference surface (see Figure 6). Reference surface is marked on retractor. To Mount the Flow Meter in a Saddle Clamp Installation: 1. Drill or bore and deburr a 1.875" diameter hole in pipe. Use a 1-7/8" hole saw. Note: Flame cutting is discouraged. 2. Clean pipe surface thoroughly particularly in the area where the gasket will sit. Check saddle gasket for proper positioning in saddle body. 3. Lubricate pipe and face of gasket with soap and water. Add antifreeze in freezing weather. Mount saddle body with gasket in place on pipe. 4. Install bales and washers on open lug side. 5. Tighten nuts evenly until saddle body conforms snugly to the pipe. 6. Turn crank clockwise to insert the flow sensor into the pipe until the calculated scale reading lines up with the arrow on the retractor bar assembly. Figure 7. Saddle clamp installation Figure 6. Scale depth tool indicator Caution: Do not force sensor into pipe if the mechanical resistance suddenly increases this condition generally indicates the pipe tap is too small. 5

hydro-flow model 3100 retractable insertion flow meter Making Electrical Connections The pulse output of the Hydro-Flow flow meter functions by momentarily shorting the (+) terminal to the ( ) terminal. Caution: If the flow meter is connected directly to a DC power source without the series resistor, both the flow meter and the power source may be damaged. The wiring polarity must be observed for proper operation of the flow meter. If the flow meter is wired backwards to the current-limited power source, the flow meter will not be damaged but it will not function properly. Pulse Output Electrical Installation The Hydro-Flow pulse output flow meter may be used with a 10 VDC to 32 VDC power supply and series current limiting resistor. The voltage at the flow meter terminals is internally limited to 8.0 ±1.0 VDC under noflow conditions, dropping to less than 1.0 V for the 2.5 to 5 millisecond duration of the output pulse. Figure 8 illustrates a typical installation. Current Limiting Resistor (Pulse Output) The current limiting resistor is required to limit the normal operating current in the flow meter to a value between 5 ma and 20 ma (with a meter voltage of 8 volts and less than 25 ma). The value of the resistor is determined by the power supply voltage, the operating meter current, and the cable resistance. Table 2 lists standard ½ watt 5% resistor values which will work in most installations. For power supply voltages between those in the table, use the lower value of resistor. Table 2. Current limiting resistor for pulse output Note: The totalizer or flow computer input must be rated for an 8-volt pulse input. Supply Voltage (DC) Current Limiting Resister Values (Ω) Minimum Maximum 10 400 400 12 480 800 14 260 1200 16 640 1600 18 720 2000 20 800 2400 22 880 2800 24 960 3200 26 1040 3600 28 1120 4000 Figure 8. Wiring diagram (pulse output) 30 1200 4400 32 1280 4800 Cabling (Pulse Output) The cable may be up to 2000 feet of #20 AWG or larger shielded two-conductor cable. The shield lead from the meter may be connected to an earth ground, such as a copper cold water pipe. The shield improves noise immunity and provides a return path for electrical surges. Its use is optional in installations in which transients and noise are not a problem. 6

installation and operation guide 4 ma to 20 ma Current Output or No Output (Display Only) Electrical Installation The Hydro-Flow flow meter may be configured to output a 4 ma to 20 ma analog signal proportional to flow rate. Electrical Specifications Table 5. Electrical specifications Enclosure Reinforced Polycarbonate, NEMA 6 Output Signal Options Pulse output: frequency proportional to flow rate. Power supply: 10 VDC to 32 VDC power supply with current limited by series resistance to between 5 ma and 20 ma. Maximum pulse width is 5 ms. See Table 2 on page 6 for standard output scaling. Other pulse output settings can be configured by the factory or reconfigured in the field using Hydro-Flow Field-Pro software. Analog output: 4 ma to 20 ma analog current loop, current proportional to flow rate. Figure 9. Wiring diagram (4 ma to 20 ma current loop) Cabling (4 ma to 20 ma Output or No Output) The flow meter may be connected with up to 2000 feet of #22 AWG or larger cable. Shielded cable may be necessary in some environments to reduce electrical noise; if used, the shield should be connected at one end only to an earth ground point, such as a copper cold water pipe. Load Resistances (4 ma to 20 ma Output) MAX. LOAD RESISTANCE (ohms) 1200 1100 1000 750 500 250 0 0 LOAD = 50(VX-10) Permissable Load Resistance Range 5 10 15 20 25 3032 POWER SUPPLY VOLTAGE (VDC) Figure 10. Maximum load resistance (4 ma to 20 ma output) Display Option Power supply: 10 VDC to 32 VDC compliance. 4 ma = zero flow; 20 ma = maximum flow listed in Table 2 on page 6. Other 20 ma settings can be configured by the factory or reconfigured in the field using Hydro-Flow Field-Pro software. No output: display only. Power supply: 8 VDC to 32 VDC, 4 ma maximum LCD display alternately shows 4-digit rate and 8-digit total flow. Mechanical Specifications Table 4. Mechanical specifications Type Measurable Fluids Pipe Sizes Fluid Temperature Fluid Pressure Ambient Temperature Flow Range Measuring Units Accuracy (combined linearity and repeatability) Insertion Assembly Materials of Construction Wetted parts Mounting Options Pipe Connection Straight Run Piping Retractable insertion Water; water/glycol mixtures; condensate 3" to 20" (80 mm to 500 mm) 32 F to 160 F (0 C to 71 C) all connections Thread-o-let connection: 400 psi (27.5 bar) maximum Saddle connection: 300 psi (20.7 bar) maximum -20 F to 140 F (-29 C to 60 C) Minimum: 1.0 foot per second (0.3 m per second) Maximum: 15 feet per second (4.5 m per second) English: gallons Metric: cubic meters Note: Other measuring units available upon request or measuring units can be reconfigured using Hydro-Flow Field-Pro software. ±1.0% of full scale Valve: ball type, 400 psi (27.5 bar) Retractor: nonrising stem Position indication: permanent scale Retractor: aluminum, nickel-plated steel Vortex sensor: Ultem (plastic) Shedder bar: 316 stainless steel Stem: 316 stainless steel O-rings: EPDM Carbon steel saddle for steel pipes Carbon steel thread-o-let 2" NPT Typical 10 diameters upstream, 5 diameters downstream. Note: For more information, see Straight Run Requirements on page 3. 7

hydro-flow model 3100 retractable insertion flow meter Hydro-Flow Model 3100 Flow Ranges Table 3. Model 3100 flow ranges Line Size Inches (mm) 3" (80) 4" (100) 6" (150) 8" (200) 10" (250) 12" (300) 14" (350) 16" (400) 18" (450) 20" (500) Minimum flow(gpm) Maximum flow Minimum flow (m3/h) Maximum flow 26.6 40.0 100.0 166.6 266.6 366 416.6 566.6 733.4 933.4 400 600 1500 2500 4000 5500 6250 8500 11000 14000 6.0 9.0 22.8 37.8 60.6 83.2 94.6 128.8 166.6 212 90.8 136.3 340.7 567.8 908.5 1249.2 1419.5 1930.6 2498.4 3179.7 Pulses per gallon Note 1 25 15 6 4 2 2 1 1 1 0.5 Pulses per cubic meter Note 1 5000 5000 2000 1000 500 500 500 200 200 200 Note 1 When flow meter is configured for pulse output Safety Information Safe operation of this product can be guaranteed only if it is properly installed, commissioned, used and maintained by qualified personnel in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment, must also be complied with. EMCO is a registered trademark of Spirax Sarco, Inc. For information on EMCO flow products, contact: EMCO Flow Systems 2150 Miller Drive Longmont, Colorado 80501 T: 800.356.9362 or 303.682.7060 F: 303.682.7069 sales@emcoflow.com www.emcoflow.com SPIRAX SARCO, INC. 1150 NORTHPOINT BLVD. BLYTHEWOOD, SC 29016 phone: 1.800.883.4411 or 803.714.2000 fax: 803.714.2222 www.spiraxsarco.com Spirax Sarco, Inc. 2009 All rights reserved. Printed in U.S.A. PM-HF3100-280-02 3/2009