ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Similar documents
Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

FlowCon SM mm. Dynamic Self Balancing Control Valve SPECIFICATIONS

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

FlowCon Energy FIT System

INSTALLATION AND OPERATION INSTRUCTION

FlowCon SH mm. Adjustable Dynamic Self Balancing Valve SPECIFICATIONS

PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5

Features Globe Valve 2-Way & 3-Way Assembly Features:

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

2-Way & 3-Way Non Spring Return Characterized Ball Valves

ATT Series Adjustable PIC Valves 2 Way 1/2-1-1/2 ATT - AutoTouch Terminal

High Pressure 2-way 2 1/2-6 Globe Valves

NETSIAN TECHNOLOGY VALVE SCHEDULE

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Product Catalog. Precision Control DeltaPValves. guaranteed delta T 10-year warranty made in the USA

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

Combi valves PN 16 with flanged connections

BVM Series Flanged Industrial Control Ball Valves 2 Way 2-1/2-12

COMMERCIAL. Product PRofile

BV Series. Threaded Industrial Control Ball Valves 2 Way 1/2-4. Increased Linear Response. Flow Curve Chart

Terminator PICV. Technical Manual

PRESSURE INDEPENDENT CONTROL VALVES (epiv & PICCV )

BACnet MS/TP Networking Flow Balancing Control Valves

ZONE CONTROLE / 2-WAY

F6300L, 12, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Electronic Globe Valves

VG6000 Series Forged Brass Valves

Accessories STRA Room Controller

599 Series Zone Valve Bodies:

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

TAC TM Butterfly Valve Assemblies

Pressure Independent Control Series

Flare Valves 1/2 inch 2-Way and 3-Way

Flowrite Globe. Pneumatic 4-inch Valve Actuator. Valves. Description. Applications. Features D-141.

VE VVG Series Electronic Two-way Valves Normally Closed

pressure independent characterized control tm

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

VRN Dynamic Pressure-Regulating Control Valves and Actuators

STEEMCO-MAS Flowmeter for Steam

Constant Flow Valves. Specifications PVC: 1/2", 3/4", 1", 2", 3", 4" PVC PVC Flanged ANSI EPDM Stainless Steel 304 with ETFE Coating º F

3 & 4-Way Rotary Valves

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

VPA Series and VAP Actuator

Pressure Independent Control Series

VE-S_15-32 Pressure Independent Balancing & Control Valves

2006 Product Range Overview. Belimo Project: One Bellevue Center, Seattle, Washington

Modulating control valve PN16

HERZ Motorised Actuator

F6200L, 8, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Written By : Simon Teo B. ENG (HONS)

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

Constant Flow Valves. Specifications Sizes: PVC: 1/2", 3/4", 1", 2", 3", 4" CPVC: 1" and 2" Body: Bonnet: Models: Seals: Springs:

NV Direct Coupled Globe Valve Actuator

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection.

VG8000N Series PN16, DN15 - DN150

Modulating control valve PN16 with magnetic actuator

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

2-port seat valves PN16 with flanged connection

Hose Length Custom Length Supply Line Options Ball Valve w/ PT UBY Strainer w/ PT and BDV

Temperature: TYPE A (1" 3") TYPE B (1/2" TYPE C (1/2" 4") TYPE D (3"

STM Series Flanged Characterized Ball Valves

VA-4233-GGx Series Electric Valve Actuators

V5000. Globe Valves Series for Terminal Units. Product Bulletin

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

PYTHON 1500 SERIES CONTROL VALVES. Pneumatic and Electric Actuated

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

Zone Valves and Parts (Honeywell)

Modulating control valve PN16 with magnetic actuator

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

Electronic Pressure Independent Valves (epiv)

Control valves with electric actuators up to 90 C PN

PRESSURE INDEPENDENT CONTROL VALVES (PICCV& epiv)

Pressure independent balancing and control valve

Pressure Independent Control Series 2-Way Valves and Electronic Valve Actuators

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

VG7000 Female Threaded Cast Bronze Valve Series with Electric Actuators

Globe Valve System for continuous control. Type 8802/2301 electro-pneumatically operated globe valve + = TWO YEAR WARRANTY on this valve system

AV-8020 Series Floating Control Actuated Valve

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT


Spring Achieve System Balance Without All The Spin. PICCV. Complete Details Inside!

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

SECTION METERS AND GAGES FOR PLUMBING PIPING

Electronic Control Valves

PP1 Series Piping Packages for VG1000 Series Ball Valves

Flowrite 599 Series High Pressure Close-Off 2-Way Valves, 2-1/2 to 6-Inch, Flanged Iron Body, ANSI Classes 125 & 250

System 350 S350P Proportional Plus Integral Temperature Stage Module

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

P1000 Series Pressure Independent Valves

Harmony Installation, Operation and Maintenance

Transcription:

The Auto Touch Independent Max (ATiMX) valve brings pressure independent control technology to valves up to 6 and flow rates up to 468 GPM. It is a state-of-the-art control valve combining a high quality/ high rangeability temperature control valve with a dynamically balanced flow regulator in the same space-saving housing. The result is a pressure independent control valve that maintains the desired flow rate irrespective of the pressure differential across the valve. Even the most controllable standard (pressure dependent) temperature control valve will allow a change in flow as the differential pressure in the system changes, which is an everyday occurrence. Any time a chilled water or hot water system is operating at less than design maximum load conditions which is most of the time differential pressures in the system tend to increase, resulting in overflow through the control valves. This overflow condition results in control instability, and higher pumping costs. Balancing valves, either manual or automatic, can only prevent overflow at conditions above design maximum flow. At any flow condition less than design maximum, balancing valves do not fulfill any purpose. The ATiMX valve provides a cost effective means of controlling hot water and chilled water flow in an accurate and stable manner while minimizing pumping, heating and cooling costs. And by combining the automatic temperature control function and the dynamic balancing function in a single device, installation costs are also reduced. ATi Max Series Pressure Independent Control Valves 2 Way 2-1/2-6 08/23/16 ATiMX Valves are also available with an optional strainer/drain with isolation valve to provide a complete and convenient solution for controlling and maintaining the coil. Features and Benefits Provides accurate, pressure independent control at all levels of demand More precise and stable control Eliminates overflow at less than design demand conditions Reduces pumping energy and contributes to higher chiller and boiler delta T Combines flow control and dynamic balancing in a single space-saving device Reduces field installation costs Eliminates field balancing Reduces total system costs and speeds the project towards completion faster AM-1

ATi Max - Specifications ATi MAX GENERAL DESCRIPTION ATi Max Series Valves are self-balancing, dynamic flow control valves that are pressure-independent, two-way, modulating to accept digital or analog input signals. The valves accept 0-10V DC, 2-10V DC, 0-20mA, 4-20mA or 2-position / 3-point floating input signals. Each valve has an adjustable maximum flow rate setting to enable flow limitation and balancing to the coils or zones that the valves are controlling. All ATi Max actuators are microprocessor-based with a self-calibrating feature. Technical Specifications - Valve Body Valve Body 2-1/2 6 Static Pressure 580 PSID (40 bar) Media Temperature -4 F to 248 F (-20 C to 120 C) Body Material Ductile Iron, ASTM A395, Class 60-40-18 Flow Regulation Unit 316 Stainless Steel Diaphragm Hydrogenated Acrylonitrile-Butadiene-Rubber End Connections Refer to Dimensions O-Rings EPDM Test Ports 1/4 NPT Max. Close-Off Pressure 100 PSI (700kPa) Max. Operational P 87 PSID (600kPa) Shut-Off Leakage < 0.2% of Cv Flow Rate Range 1.48-29.5 l/sec, 23.4-468 GPM Technical Specifications - Strainer Pressure Rating 175 PSI (12 bar) Temperature Rating 150 F (65 C) Body Material Cast Iron ASTM A126 Class B End Connections Flanges ANSI B16.1 Class 125 Strainer Stainless Steel 304 ASTM A167 Technical Specifications - Actuator - BMT-BMFS (FS=Fale Safe) Supply Voltage Power Consumption 12VA Frequency 50-60 Hz Control Input 0-10V DC, 2-10V DC, 0-20mA, 4-20mA or 2-position / 3-point floating Feedback Position Output Automatic match of control input, 0-10V DC, 2-10V DC or 4-20mA, Turn Time 190 seconds (from closed to fully open) Feedback Position Automatic match of control input, Output 0-10VDC, 2-10VDC or 4-20mA Electrical Connection 5 wires halogen free cable, 3.28 ft. Direction of Rotation Bi-directional Housing Material UL94 V0-rated plastic Humidity Rating 5 to 95% RH, non-condensing Housing Insulation IP54 including up-side down mounting Ambient Temperature 14 F to 122 F (-10 C to 50 C) Programming External programming of all settings, interface of buttons and display Calibration Automatic calibration at startup Disclaimer - The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Bray office. Bray, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. AM-2

ATi Max - Operation ATi Max Valve Operation The plug of the valve is positioned by a multi-turn electric actuator in response to temperature controller or building automation system. Inlet pressure is transferred through an internal channel to a diaphragm in the pressure compensating section. This diaphragm is opposed by a spring. The force-balance principle moves the diaphragm to create a constant ΔP across the control section, which results in constant flow at any valve position, irrespective of pressure changes in the system. The maximum flow rate is established by controlling the stroke of the actuator. ATi Max - Valve Sizing Unlike conventional control valve sizing where valves are sized to a Cv, the ATi Max valves are simply sized for flow and pipe size. Refer to the ordering table for the wide range of flow values available. IMPORTANT: Valve diameter should NEVER exceed pipe diameter! ATi Max - Installation Contrary to traditional static balancing systems, dynamic balancing requires no main branch balancing valves. Principle of Operation ATi Max valves contain a diaphragm component mounted on a counter-acting coil spring which adjusts the pressure differential across a pre-set valve opening. The combined components operate very similar to two valves in series, where one is a pressure differential regulator and one an adjustable orifice. This is illustrated below. When the ATi Max valve is used at each terminal, the total flow rate of the branch will automatically be limited to the sum of the flow rates of the circuit. The ATi Max valve can be installed either in the supply or in the return line. The valve should be positioned for easy access to the adjustment and pressure measurement devices. Unlike traditional balancing valves, placement of the ATi Max does not require lengths of pipe before or after the valve. ATi Max - Piping top pressure port is upstream, the bottom port is downstream. AM-3

ATi Max - Internal View & Digital Display Overview Position Display Actuator: Flow Rate can be determined by reading value on top of actuator. Multi turn actuator: Six full 360 rotations make the ATi Max the most accurate valve in the industry. PROGRAMMING MENU The programming menu is always accessible. To enter the programming menu, please simultaneously press and for 6 seconds, until bottom line blinks. Alarm Indicator Operational Information Generally, press to accept value and go to next step and press button to go to previous step. To change the value, please press or keys, for quick scroll through values hold down the button. Press and simultaneously for 6 sec. to exit programming menu. Battery Level! L/hr GPM L/sec mavdc Actuator will automatically return to operation mode if no action is detected on arrow keys during 1 minute. Indicates actual current flow rate. Internal View ATi Max Buttons Unit Scale System Automatic Pressure Compensating: Spring and diaphragm move according to pressure differential maintaining a constant pressure drop across the flow control port. Pressure / TemperatureTest Ports: Enable easy pressure differential readings. Flanged Connection: 2-1/2 to 6 and with ANSI Class 150 or Class 300 flanges. Manual Operation: Valve can be operated in the event of a power failure. Sizes available: 2-1/2 to 6 Maximum high limit flow rate: 41 to 468 GPM. AM-4

ATi Max - Dimensions B ATi Max Dimensions, 2-1/2-6 - with Actuator MODEL #, PREFIX, Size A B C Weight ATiMX Size in. mm in. mm in. mm in. mm lbs. kg. ATiMX-S 2.50 65 3 80 8.8 224 9.9 252 3.7 94 33.1 15 ATiMX-M 3 80 4 100 12.6 320 11.6 295 5.3 135 68.5 70.5 31 32 C ATiMX-L 5 125 6 150 16.6 422 13.5 343 7.1 180 134.5 61 Measurements and Weights include Actuator Add connection lenght to body length A Port 1 ATi Max Strainer Dimensions, 2-1/2-6 B C MODEL #, PREFIX, Strainer Size SD-250 SD-3 SD-4 SD-5 SD-6 Size A B C Hole. of Drain Size Weight in. mm in. mm in. mm in. mm Dia. Holes in. mm lbs. kg. 2.50 65 11.3 287 7.6 193 10.4 264 0.75 4 1 25 36 16 3 80 12.5 318 8.3 211 11.3 287 0.75 4 1 25 44 20 4 100 14.9 378 10.1 257 13.8 351 0.88 8 1-1/4 32 68 31 5 125 17.9 455 12.5 318 18.0 457 0.88 8 1-1/4 32 117 53 6 150 20.4 518 14.3 363 19.1 485 0.88 8 1-1/2 40 147 67 A ATi Max - Flange Compatibility Chart ATi MAX VALVE MODEL # PREFIX ATiMX Size ATiMX-S ATiMX-M ATiMX-L Please allow 2% tolerance Weld Neck Slip On Weld Neck Slip On Connection ANSI ANSI DIN DIN in. mm Class 150 Class 300 Class 150 Class 300 PN 10 PN 16 PN 25 PN 40 PN 10 PN 16 PN 25 PN 40 2-1/2 65 3 3 80 80 4 5 6 100 125 150 IMPORTANT: Valve diameter should NEVER exceed pipe diameter! AM-5

ATi Max - Flow Rate Table Model no. Valve size Control range Minimum setting Maximum setting mm inch kpad psid l/sec l/hr GPM l/sec l/hr GPM S-113 65 2 1/2 30-600 4.5-87 2.57 9240 40.7 7.15 25700 113 M-149 100 4 30-600 4.5-87 3.49 12600 55.4 9.38 33800 149 M-225 100 4 35-600 5.1-87 4.73 17000 75.0 14.2 51000 225 M-320 100 4 50-600 7.3-87 3.68 13300 58.3 20.2 72700 320 L-369 125 5 150 6 30-600 4.5-87 6.48 23300 103 23.3 83800 369 L-468 125 5 150 6 35-600 5.1-87 7.10 25600 113 29.5 106000 468 Accuracy: Greatest of either ±5% of controlled flow rate or ±2% of maximum flow rate. ATi Max - Actuator Wiring DIGITAL - 2 POSTION ANALOG Black Blue White Green Common Control Signal Feedback Supply 24V AC/DC Supply 24V AC/DC Black Blue White Red Green DIGITAL - 3 POINT FLOATING Black Blue White Red Green Common Open if N.C., Close in N.O. Close if N.C., Open in N.O. Feedback Common Open if N.C., Close in N.O. Close if N.C., Open in N.O. Feedback ATi Max - Model Number Matrix ATi Max = AutoTouch independent Max Coil Control System Sample Model Number ATiMX M 222 BMT SD4 BF4 RETURN Select the Proper ATi Max Prefix ATiMX Size and Maximum Flow Rate: See Flow Rate Table (See chart above) Select BMT-NON Fail Safe or BMTFS-Fail Safe SUPPLY Strainer/Drain Valve N = Strainer Drain Valve or SD250 = 2.5 SD5 = 5 SD3 = 3 SD6 = 6 SD4 = 4 MANUAL Manual Shut-Off Valves N = Shut-Off Valves or BF250 = 2.5 BF5 = 5 BF3 = 3 BF6 = 6 BF4 = 4 2016 Bray International, Inc. AM-6