Anti-Pollution Ecological System

Similar documents
ENVIRO UNIT CES SERIES

Air Purification Unit Grease, Smoke, and Odor Abatement for Commercial Kitchen Applications

When Time Matters! listed Fire Damper

Roof & Sidewall Mounted

Filtered Kitchen Supply Packaged Ventilator

Centrifugal Filtered Supply Roof Blowers

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Halton - Advanced Air Purification, Now with ELF Extended Life Filters!

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Air Moving Solutions. low pressure mixed flow fans. QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat)

Ceiling and Inline Fans

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Industry best 5 year fan housing warranty, 1 year motor warranty

Centrifugal Ventilators Direct-Drive Upblast Centrifugal Roof & Wall Ventilators

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

A. NU2035 HRV Specifications NU2035

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

SECTION DUCTWORK ACCESSORIES

Complete HVAC Capability

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

Roof Upblast and Sidewall Exhaust

Wholesale Ventilation Products

DEN RANGE Compact Ecology Unit for Commercial Kitchen Ventilation. Technical introduction

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER


KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

LOW PRESSURE MIXED FLOW FANS

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

Industry best 5 year fan housing warranty, 1 year motor warranty

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

Tubular Centrifugal Fans

ENVIRO-PAK FILTER ASSEMBLY CATALOG. molitron.com. Phone:

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Roof Upblast and Sidewall Exhaust

KVI Kitchen Canopy With Capture Air

High Capacity Ventilation

EcoWatt Products. Advancing Ventilation

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Centrifugal Spun Aluminum Products

Inline Fans [ 14 ] * UL is optional and must be specified.

Twin City Fan & Blower

Centrifugal Upblast Power Roof Ventilators

Viking Installation Guide

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER

Industry best 5 year fan housing warranty, 1 year motor warranty

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

FILTERED SUPPLY CENTRIFUGAL Belt Drive

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

DESIGN GUIDELINES FANS PAGE 1 of 7

KITCHEN VENTILATION SOLUTIONS

KWF Water Wash Canopy with Supply Air

Multi-Port Centrifugal Fans for Round Duct

Inline and Roof Mounted Fans

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

Downblast Centrifugal Fans with ECM

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

MODEL FF50 CEILING FAN

Centrifugal Utility Fans - SFD/SFB

Direct Gas-Fired Heating

forward curved inline duct blowers

FAN POWERED TERMINAL UNITS

Direct Gas-Fired Make-up Air Heaters

A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

MIXVENT-TH Series Mixed Flow Fans

MAH. Modular Air Handling Unit

SECTION AXIAL HVAC FANS

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Viking Installation Guide

Zoneflow Engineering Installation and Maintenance Manual

AIR-AIR ENERGY CONSERVATION MODULE

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

VAHU Vertical Air Handling Unit

ACCESSORIES FOR DUCT FANS

Commercial Fans & Dampers

Greenheck Quick Delivery

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

Air Boss M-Series Media & Adsorption Air Cleaner

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

EXHAUST FANS CUD & CUB UPBLAST FANS

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

Centrifugal Spun Aluminum Products

REPLACEMENT PARTS MANUAL

Centrifugal Spun Aluminum Products

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

REPLACEMENT PARTS MANUAL

TUBULAR CENTRIFUGAL INLINE FANS

TORIN by: AIRDEX Index Page No.

Defining Innovation. mixed flow fans. TYPE QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) QFE (Fume Hood Exhaust)

Inline & Sidewall Exhaust Fans

Transcription:

The FST ecological system was designed to meet all types of commercial kitchen installations. The ecological system is an environmentally-friendly solution that helps maintain air quality. The main objective of the ecological system is to extract the maximum amount of grease in the air emanating from the kitchen hood, to then vent it through the exhaust system and out of the building. nstalling an ecological system also has several other advantages: The filtered air from the system can be vented to the outside of the building at ground level, generating substantial savings by eliminating the use of a fully welded duct all the way to roof level. fully welded duct between the hood and the filtration section in accordance with NFP96 and a standard duct as per the National uilding ode of anada between the fan section and the outside of the building. 99 % of all grease and smoke from the kitchen hood is extracted by the ecological device. Fire risk is greatly reduced. cceptable reduction of cooking odours emanating from the hood. The entire unit can be installed in the kitchen ceiling, a service room or on the roof. an be installed in a multi-restaurant project such as a food court. an be installed in a heritage building or a building with a specific architecture. listed The exterior finish of the unit is stainless steel. 2-i

Optional fire protection system section Filtration section Optional odour control section Exhaust blower section Optional fire protection system section The fire protection system section is one of the options available for the ecological device. ccording NFP 96. standards, a fire protection system must be installed on an ecological system. There are two possibilities: the installation of an FST fire protection system or the installation of a fire protection system on the job site by a certified company. The fire protection system shall be supplied with a dual micro-switch to connect to the building fire alarm system. 3-i

Filtration section The FST EO filtration section has a stainless steel casing and steel double inner walls insulated with 1 (25 mm) of ceramic wool. oth walls are 16 g thick. ccess doors are double-walled, insulated, and hinged. The greasy air from the kitchen hood and its exhaust duct enter the filtration unit to be filtered and degreased. The filtration section consists of a series of three filter sections, two sections of listed fire dampers and pressure switches to check the condition of the filters in the section. The three filtration sections are: Pleated prefilters 4 (102 mm) thick, 30% SHRE 52-76. Pocket filters 18 (455 mm) thick, 90% SHRE 52-76. bsolute filters 12 (300 mm) thick, 99,97% HEP.O.P. 1- lass or Optional odour control section The optional odour control section is installed downstream from the filtration section and consists in injecting liquid FST Neutral-ir in the exhaust flow to neutralize odour causing bacteria. The injection cycle may be permanent or intermittent during kitchen hood and cooking appliance operation. The device is certified with or without the odour control section. Exhaust blower section The outer casing of the FST H exhaust blower section is stainless steel. t has a perforated galvanized steel double inner wall insulated with 1.5 of acoustic panels. oth walls are 16 g. ccess doors are double-walled, insulated and hinged. The exhaust blower section includes, but is not limited to: One double-width, double inlet fan One wheel statically and dynamically balanced with back-tilted blades ntivibration isolators under the blower and motor prewired magnetic starter to the motor disconnect switch 4-i

MOEL EO 10 FM E F G H J K WEGHT EO 20 EO 30 EO 40 EO 50 EO 60 EO 80 EO 100 EO 120 EO 150 EO 180 THE MENSONS LSTE ON TOP RE N NHES N T THE OTTOM RE N MM (LGHT GRY). 5-i