APS100 Rental Generator Set Preliminary Specification

Similar documents
XQ80 RENTAL. 60 Hz FEATURES

XQ60 RENTAL. 60 Hz FEATURES EPA TIER 3 AND CARB CERTIFIED FOR NON-ROAD MOBILE APPLICATIONS

Standby. Speed rpm 60 Hz 480/277V 30 (38) 27 (35) Hz 208/120V 30 (38) 27 (35) Hz 240/120V 30 (30) 27 (27) 1800.

XQ175 RENTAL. 60 Hz FEATURES EPA TIER 3 AND CARB CERTIFIED FOR NON-ROAD MOBILE APPLICATIONS

D I E S E L G E N E R A T O R S E T S

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Standby kw Prime kw

DIESEL GENERATOR SET. 60 Hz FEATURES

DIESEL GENERATOR SETS

XQ 200 R E N T A L. STANDBY 200 kw PRIME 182 kw. POWER MODULE 60Hz 1800 rpm 480V FEATURES

60 Hz FEATURES. Exclusively from your Caterpillar dealer

30kW Standby / 27kW Prime Power Towable Generator

RENTAL DIESEL GENERATOR SET

80kW Standby / 70kW Prime Power Towable Generator

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

STANDBY 200 ekw 250 kva

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

RENTAL XQ400 SOUND ATTENUATED. 50/60 Hz FEATURES

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer

Diesel generator set QSK23 series engine

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

GEP110 (3-Phase) 50 HZ. 100 kva / 80 kw 60 HZ. 113 kva / 90.4 kw FEATURES. Exclusively from your Caterpillar dealer

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

GEP30 (3-Phase) 50 HZ. 27 kva / 21.6 kw 60 HZ. 30 kva / 24.0 kw FEATURES. Exclusively from your Caterpillar dealer

Rental Power 800 kw. Specification sheet. Description. Features. Options

GEP50-3 (3-Phase) 50 HZ kva / 40.0 kw 60 HZ kva / 45.0 kw FEATURES. Exclusively from your Caterpillar dealer

STANDBY 200 ekw 250 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Diesel generator set QSK23 series engine

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Diesel generator set QSX15 series engine

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

GEPH17SP (1-Phase) 50 HZ 17.5 kva / 17.5 kw FEATURES. Exclusively from your Caterpillar dealer

Diesel generator set QSB7 series engine

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

POWER MODULE MTU 16V4000 DS2560

Standby kw (kva) 480V 50/60 Hz Switchable Rating

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

10,000 Watt Diesel Generator AGi9P E

13,000 Watt Diesel Generator AGi13P E

Spark-ignited generator set

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

XQ2000 SOUND ATTENUATED POWER MODULE

Diesel generator set QSX15 series engine

Dual XQ350 Rental Package

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

Rental Power QSL9 series engine

Rental Power QSB7 series engine

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Model MP150 W W

Diesel generator set 6BT5.9 series engine

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

Spark-ignited generator set

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

Model NA 2 L

DIESEL GENERATOR SET FEATURES

Rating Definitions and Conditions

WPS100/S EP Series. Features:

Rating Definitions and Conditions

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

Diesel generator set 4BT3.3 series engine

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

WPS150/S EP Series. Features:

Rating Definitions and Conditions

PRIME 365 ekw 456 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Caterpillar 1500kW XQ1500

STANDBY 240 ekw 300 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

WPS60/S EP Series. Features:

Specifications. Cat XQP150 Rental Generator Set. Prime 120 kw, 150 kva 50/60 Hz Switchable EU Stage IIIA. Prime kw (kva)

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

Transcription:

BARTONVIE * CEDAR RAPIDS * DAVENPORT * EAST PEORIA * HANNIBA * MOBERY * ROCK FAS * SPRINGFIED * URBANA APS100 Rental Generator Set Preliminary Specification STANDBY 100 kw 60 Hz/PRIME 90 kw 60 Hz FEATURES EPA TIER 4 INTERIM AND CARB CERTIFIED FOR NON ROAD MOBIE APPICATIONS. An extremely rugged construction fully weather resistant enclosure incorporates an internally mounted exhaust silencer. Highly corrosion resistant construction. o Body made from sheet steel components pretreated with zinc phosphate prior to polyester powder coating at 200 C (392 F) o Black stainless steel pad lockable latches. o Zinc die cast hinges o Black powder coated grab handles Excellent access for maintenance. o Two large doors on each side. Two rear doors for distribution/control panel. o o Front panel for air discharge box access. ube oil and cooling water drains piped to exterior of the enclosure with interior valves Security and safety. o Plexiglas control panel viewing window in a lockable access door. o Fuel fill and battery can only be reached through lockable access doors. ROBUST DESIGN FOR RENTA ENVIRONMENT Packages designed to survive in a rugged environment. WYE 208/120V 100 (125) 90 (112.5) WYE 480/277V 100 (125) 90 (112.5) DETA 240/120V 3 phase 100 (125) 90 (112.5) Double Delta 240/120V 1 phase 67 (79) 56.7 (70.8) *Refer to distribution panel specifications for details REAR CUSTOMER ACCESS Separate control panel and distribution panel access doors. Hinged door over main bus connectors with safety switch External emergency stop on panel Remote start/stop contacts ENVIROMENTAY FRIENDY DESIGN EPA Tier 4I off highway compliant engine. U double walled fuel tank base with 24 hour minimum fuel supply. 110% Engine fluid spill containment Sound attenuated enclosure for low noise EECTRONIC GOVERNING Isochronous. Fully Adjustable ADEM 5 Voltage Standby kw (kva) OPTIONS Tandem Axle Trailers with electric brakes Two gallon oil makeup system Prime kw (kva) MUTI VOTAGE DISTRIBUTION PANE Switchable 3 phase voltage output: 480/277volt WYE, 208/120volt WYE, 240/120volt DETA (B phase high leg), 240/120volt single phase, Double DETA 1

STANDARD FEATURES 1. ENGINE Heavy duty industrial EPA Tier 4I compliant diesel engine. Electronic governor, compliant with BS5514 Class G2. 1.1 Jacket Water Heater 1800 watt 120 volt AC with thermostat 2. COOING RADIATOR Radiator and cooling fan complete with protection guards, designed to cool the engine in ambient temperatures up to 43 C (110 F) 3. ENGINE FITRATION SYSTEM Cartridge type dry air filters with restriction indicator. Dry, 2 stage cyclonic paper element. Cartridge type fuel filters and full flow lube oil filters. All filters have replaceable elements. 4. EXHAUST SYSTEM Vertical Discharge critical silencer with flexible connector. All internal pipework thermal blanketed 5. EECTRICA SYSTEM 12 Volt Starter Motor system with 100 Amp charging alternator, 12V Cat brand maintenance free battery, battery rack, and cables. Package mounted 6 amp battery charger. 6. GENERATOR Screen protected and drip proof, selfregulating brushless generator with fully interconnected damper windings, IC06 cooling system and sealed for life bearings. Switchable voltage output. 6.1 Insulation System The insulation system is Class H. Windings are impregnated in triple dip thermo setting moisture, oil and acid resisting polyester varnish. Heavy Coat of anti tracking varnish for additional protection against moisture or condensation. 6.2 Electrical Characteristics Electrical design in accordance with BS5000 Part 99, IEC60034 1, EN61000 6, NEMA MG 1.22. 6.3 Automatic Voltage Regulator (AVR) The EMCP integrated voltage regulator maintains the voltage within the limits of ±0.5% at steady state from no load to full load. The control panel door incorporates a voltage adjustment potentiometer. 6.3.1 Permanent Magnet Generator Providing 350% short circuit capabilities enhanced motor starting and non linear loading performance. 6.4 Waveform Distortion, THF and TIF Factors The total distortion of the voltage waveform with open circuit between phases or phase and neutral is in the order of 1.8. On a 3 phase balanced harmonic free load the total distortion is <4%. Machines are designed to have a THF less than 2% and a TIF less than 50. A 2/3 optimal pitch factor is standard on all stator windings. 6.5 Radio Interference Suppression is in line with the provisions of EN61000 6. 7. MOUNTING ARRANGEMENT 7.1 Base frame The complete generator set is mounted on a heavy duty fabricated steel base frame. The base frame includes a U listed dual wall closed top fuel tank and incorporates specially designed single point lift. 7.2. Coupling The engine and generator are directly coupled by means of an SAE flange. 2 The engine flywheel is flexibly coupled to the generator rotor and a full torsional analysis has been carried out to guarantee no harmful vibration will occur in the assembly. 7.3 Anti Vibration Mounting Pads Captive anti vibration pads affixed between engine/generator feet and the base frame ensuring complete vibration isolation of the rotating assemblies. 7.4 Safety Guards The fan, fan drive, and optional battery charging alternator drive are fully guarded for personnel protection. Heat guards protect personnel from the exhaust pipe 8. FUE SYSTEM Fuel feed and return lines to the engine are terminated at the base frame mounted 24 hour extended capacity fuel tank. 3 way valves allow connection of auxiliary fuel tank. 8.1 Primary Fuel Filters Primary fuel filters in addition to cartridge type fuel filters. 9. CONTRO SYSTEM 9.1 Control Panel EMCP 4.2 in a NEMA 1 sheet steel enclosure with a hinged lockable door. FEATURES: EMCP 4.2 display Panel light on/off switch Emergency stop pushbutton amp test/reset pushbutton Voltage adjust potentiometer Alarm and shutdown indicators Convenient service access for CAT Dealers (service tools not included) Frequency Adjust Potentiometer

EMCP 4.2 ENGINE OPERATOR INTERFACE Controls o Run/Auto/Stop o Speed Adjust o Voltage Adjust o Emergency Stop o Cycle crank o Remote start/stop Engine Monitoring: o RPM o Operating hours o Coolant Temperature o Crank attempt and successful start counter o DC Volts o Oil pressure o Fuel evel o Intake Manifold Temperature o Fuel Temperature o Boost o Fuel Consumption Generator Monitoring: o volts, N volts, Current (phase) o Average volts, Amps, Frequency o ekw, kva, kvar, kw hr o Power Factor (Average Phase) o kw hr, kva hr (Total) Shutdowns with common indicating light for: o ow oil pressure o High Coolant Temp o Failure to Start (Over crank) o Emergency stop o Over speed o ow Coolant evel EMCP 4.2 GENERATOR PROTECTIVE REAYING Generator protective features provided by EMCP 4.2 Generator phase sequence Over/Under voltage (27/59) Over/Under frequency (81 O/U) Reverse Power (kw) (32) Reverse Reactive Power (kvar) (32RV) Over current (50/51) 9.2 DC and AC Wiring Harnesses DC and AC wiring harnesses utilizing industrial type multi pin connectors to permit fast fault finding. 10. DISTRIBUTION PANE Separate load and control sections Access using a hinged padlockable door Main bus bar with hinged cover door with a clear Plexiglas window Customer convenience power receptacles protected by miniature circuit breaker 1 Single phase California Twist lock, 50 Amps @208 Volt phase, 120 Volt phase to neutral (adjustment to 240/139). Receptacles not for use with Delta configurations 2 Single phase GFCI Duplex receptacles, 15 Amps @120 Volts. 1 Single phase NEMA locking receptacle, 20 Amps at 208/120V. (Adjustment to 240/139). Receptacles not for use with Delta configurations Two wire remote start connection terminals 2 30A, 125V single phase NEMA locking inlet receptacle. 11. CIRCUIT BREAKER Includes DC shunt trip coil activated on any monitored engine or electrical fault 3 25 KA Interrupting capacity at 480 VAC Fixed type, 3 poles, generator set mounted 1 3 Pole 400 Amp MCCB with solid neutral (4 wire). U/CSA listed with shunt trip. Integral trip unit for thermal and magnetic overload protection. 12. CHANGE OVER SWITCH Includes switch providing voltage setting input to the EMCP 4.2 for automatic set point configuration 13. DOCUMENTATION Operation and maintenance manuals, circuit wiring diagrams and instruction leaflets supplied 14. SOUND ATTENUATED ENCOSURES A noise reducing enclosure surrounds the entire generator set, combined with a critical engine silencer. This provides an overall noise reduction to 72dBa, at 23 feet through the range. 15. FACTORY TESTS Every generator set is load tested. All protective devices, control functions are simulated and the generator and its systems checked, proved and then passed for dispatch. 16. STANDARDS The equipment meets the following standards: BS4999, BS5000, BS5514, IEC60034, EN61000 6 and NEMA MG 1.22. 17. WARRANTY Full manufacturer s warranty

APS100 Generator Set Technical Data 1800 rpm/60 HZ Standby Prime Power Rating kw (kva) 100 (75) 90 (68.8) ubricating System Type: full pressure Oil filter: spin on, full flow Oil cooler: water cooled Oil type required: API CF 4 Total oil capacity Oil Pan Fuel System Generator set fuel consumption 100% load 75% load 50% load Fuel tank capacity Usable Fuel capacity In the spirit of innovation, specifications and features are subject to change without notice. (3-14) /hr /hr /hr 8.0 (2.1) 7.0 (1.8) 29.1 (7.7) 23.5 (6.2) 17.6 (4.6) 655 (173) 574 (151) 8.0 (2.1) 7.0 (1.8) 26.9 (7.1) 21.8 (5.8) 16.4 (4.3) 655 (173) 574 (151) Running Time @ 75% Hours 27 29 Cooling System Radiator system capacity including engine (U.S.gal) 17.1 (4.49) 17.1 (4.49) Air Requirements Combustion air flow Maximum air cleaner restriction Radiator cooling air (within enclosure) Generator cooling air kpa (in H 2 O) 8.4 (297) 8.0 (32.2) 230 (8,135) 26.4 (933) 8.5 (300) 8.0 (32.2) 230 (8,135) 26.4 (933) Exhaust System Exhaust flow at rated kw 17.5 (618) 16 (572) Exhaust temperature at rated kw dry exhaust C ( F) 522 (972) 524 (975) Generator Set Noise Rating (Estimated) [with enclosure at 7 meters (23 feet)] dba 72 72 CSA Certification pending SPECIFICATIONS GENERATOR Voltage regulation. ± 0.5% at a steady state form no load to full load Frequency ± 0.25% for constant load from no load to full load Waveform distortion THD < 4% Radio interference Compliance with EN61000 6 Telephone interference..tif <50, THF < 2% Over speed limit.2250 rpm Insulation.Class H Temperature rise Within Class B limits Available voltages Simultaneous 3 phase voltage output: 480/277 volt, 208/120 volt and adjustable for 3 phase 240 volt output Deration Consult factory for available outputs Ratings At 30 C (86 F), 152.4m (500 ft) 60% humidity, 0.8 pf ENGINE Manufacturer.Caterpillar Model..C 4.4 Type...4 cycle Aspiration.Turbocharged Cylinder configuration In line 4 Displacement (cu in) 4.4 (269) Bore mm (in).105 (4.13) Stroke mm (in) 127.0 (5.0) Compression ratio 18.3:1 Governor...Type Fully Electronic.Class..ISO 8528 5 G2 Piston speed m/sec (ft/sec). 7.62 (25.0) Engine speed rpm...1800 Maximum power at rated rpm kw.standby.100.prime....90 4

With ube Oil And Coolant Weight With Fuel, ube Oil and Coolant kg (lb) ength Width Height Model mm (in) mm (in) mm (in) kg (lb) APS100 3404 (134) 1346 (53) 2144 (84.5) 3094 (6820) 3604 (7945) APS100 with trailer 5194 (205) 2108 (83) 2642 (104) 3615 (7970) 4125 (9095) RATING DEFINITIONS Standby Applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The generator on the generator set is peak prime rated (as defined in ISO8528 3) at 30 C (86 F). Prime Applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and the generator set can supply 10% overload power for 1 hour in 12 hours. 5