Redflow Telco Application Whitepaper

Similar documents
Understanding the Redflow Battery

Renewable Hybrid / Off-grid Solutions

Singapore CEEA, Oct 2010 Chris Winter, CTO RedFlow. Energy Storage, renewables and the Smart Grid: Technology and business case considerations

RedFlow White Paper Understanding the RedFlow Battery March Understanding the Redflow Battery

THE UNIQUE FLOW BATTERY SYSTEM DESIGNED FOR YOUR HOME OR OFFICE

HOMER OPTIMIZATION BASED SOLAR WIND HYBRID SYSTEM 1 Supriya A. Barge, 2 Prof. D.B. Pawar,

Key Learnings from The Establishment of a Battery Energy Storage Testing Facility. by Peter Langley, Eskom Research

DANGER. The Conext products below can utilize Load Shedding and Load Shifting:

Case Study. R510 Residential Energy Storage Newington Smart Home Trial. October - December 2012

off-grid Solutions Security of supply Basics: Off-grid energy supply

Flow Battery Testing & Demonstration Project

Move with the SUN All DC Solar Systems. Green Power Outsourcing. GSMA SEA working group. July 24-25, Mr. TK Shih.

Charging of HOPPECKE OPzV solar.power battery in Solar Applications

Green Solutions to Power Problems (Solar & Solar-Wind Hybrid Systems )

Redflow White Paper Field Application Experience of Zinc- RedFlow Field Application Experience of. Zinc-Bromide Flow Batteries in a Smart Grid

100% Renewable Energy for Islands. Case studies Tuvalu & Tokelau

Bundaberg Sugar Industry Renewable Energy Project Objectives

Where Space Design see the future of renewable energy in the home

HYBRID POWER FOR TELECOM SITES

Energy Storage Systems by. Positronic. Manufacturing Pty Ltd

POWER YOUR TELECOM SITE WITH CAT HYBRID POWER FOR TELECOM APPLICATIONS

Narada high temp. battery

Advanced Alternative Energy Solutions HSS. Hybrid Storage Solution HYBRID ALTERNATIVE ENERGY STORAGE COMBINED WITH INTELLIGENT CONTROLS

Todae Solar s 1.22 MWp Rooftop Solar Photovoltaic Installation for Stockland Shellharbour, NSW.

THE BUSINESS CASE FOR INDUSTRIAL-SCALE BATTERIES

Renewable Energy in Small Island Grids. Design and Case study - Tuvalu

OPTIMIZATION OF SOLAR-WIND-DIESEL HYBRID POWER SYSTEM DESIGN USING HOMER. I. A. Wibowo *, and D.Sebayang

Off-grid Power for Wireless Networks. Training materials for wireless trainers

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

THE FORGOTTEN BATTERY, LEAD ACID.

Evaluation of photo voltaic generating system performance for fishing light application

Microgrids Outback Power Technologies

DC Microgrids and Distribution Systems for Residences

NorthStar Battery (NSB) Telecom Application Manual

A Study of Lead-Acid Battery Efficiency Near Top-of-Charge and the Impact on PV System Design

Magellan Stand Alone Power System (1P) Magellan Renewables Range

Magellan Stand Alone Power System (3P) Magellan Renewables Range

A flywheel energy storage system for an isolated micro-grid

INDUSTRIAL SOLAR OFF-GRID APPLICATIONS

System selection for Stand-alone S

:43 1/13 Victron & BYD B-Box

IMEON 9.12 USER MANUAL

UFLEX KITS FOR SELF CONSUMPTION SYSTEM & ENERGY STORAGE. Solutions in kits for:

Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition

generate + manage + store + share

LG Energy Freedom Solution

Enphase AC Battery Parameters for NREL System Advisor Model (SAM)

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

Development and operation of MW-scale Li-ion battery systems: Challenges, solutions, results. Jesus Lugaro

EcoSafe EOPzV. Operation Guide for Solar Applications

The complete solar water pumping solution with SmartSolution hybrid power support

Turbo-charging Your Forklift Fleet: The Power of Industrial Lithium Forklift Batteries

The system is neat and tidy in its installation, has met the client s requirements and creates an excellent model for other hybrid systems.

Current Automation Catalogue

International Journal of Advance Research in Engineering, Science & Technology

How To Set Up SimpliPhi Batteries Using OutBack Chargers

ALZ Electrical Solar Consumer Guide

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

A simulation tool to design PV-diesel-battery systems with different dispatch strategies

LIFE CYCLE COSTING FOR BATTERIES IN STANDBY APPLICATIONS

Idle-Reduction Technologies. A White Paper To Discuss The Opportunity and the Challenges

Achieving Energy Independence with Off-grid, Battery-based Solar Energy Systems. Vinod Tiwari Director Renewable Power Solutions (Telectron LLC)

SimpliPhi Power PHI Battery

Development of Motor-Assisted Hybrid Traction System

SOLAR CHARGE CONTROLLERS

Configuration Diagrams

Investor Open Day 2017 The Olde House, Cornwall, 25 October Scott McGregor, Chief Executive Officer

SAFT approach to on-grid Energy Storage Intensium Max and ESS experiences Javier Sánchez

CALL FOR A QUOTE (877)

DC and AC coupling: which one is the best solution?

Mia Sylvester Technical Sales Advisor Fronius UK FRONIUS PV STORAGE SOLUTION TRAINING

Solar Power For Your RV

PowerOasis GPM Accra. John O Donohue Nov 2012

Abstract. Introduction

A STUDY ON ENERGY MANAGEMENT SYSTEM FOR STABLE OPERATION OF ISOLATED MICROGRID

Solar Power. Demonstration Site. Annual Performance Report 2017

GOODBYEGRID. Battery Storage Systems. We cut the cost of power. Currently available for purchase in Australia (March 2016) 1.

PV-Battery-Hybrid-Systems the alternative power generation. Conferencia de Energías Renovables, Guatemala, 13 de abril

Energy Storage Systems

Technical Note. Management of Sealed Lead Acid Batteries in Reliable Small DC Standby Power Supply Systems

SimpliPhi Power PHI Battery

Introduction: Supplied to 360 Test Labs... Battery packs as follows:

Analysis of a Hybrid Energy Storage System Composed from Battery and Ultra-capacitor

Field Verification and Data Analysis of High PV Penetration Impacts on Distribution Systems

Behaviour of battery energy storage system with PV

Three phase Solar Pump

Example 1MW Solar System for Fosters Yatala

Remarkable CO 2 Reduction of the Fixed Point Fishing Plug-in Hybrid Boat

Take control of your power

Australia's future for power generation

SIZING AND TECHNO-ECONOMIC ANALYSIS OF A GRID CONNECTED PHOTOVOLTAIC SYSTEM WITH HYBRID STORAGE

Keeping you connected

Design and Analysis of Hybrid Renewable Microgrid Systems for United Nations WFP Humanitarian Locations in Developing Countries

The purpose of this document is to help familiarize you with some of the terminology, definitions and system types used. It helps to answer some of

Ancillary Services & Essential Reliability Services

USAGE OF ACCUMULATION TO SUSTAIN THE DAILY DIAGRAM OF ELECTRICITY PRODUCTION IN PHOTOVOLTAIC POWER PLANT

Uninterrupted Efficient Energy Solutions through Solar For Urban Office Building And Cold Storage Applications

C PER. Center for Advanced Power Engineering Research C PER

SimpliPhi Power PHI Battery

SIZE, SAFETY & KNOWLEDGE NINO NIZIC MANAGING DIRECTOR SOLARWATT AUSTRALIA

Transcription:

Redflow Telco Application Whitepaper RedFlow Telco Application Whitepaper 2015

1. Introduction This article reports about the successful demonstration of the RedFlow Zinc Bromine Module (ZBM) integrated into a standard telecommunication (Telco) DC system at -48V. The ZBMs, installed directly on the DC bus, can replace standard lead acid batteries and support the load when the power from the grid or from a diesel generator (DG) is not available. In this specific study, the ZBMs are used to integrate renewable sources (PV) with an existing DG allowing the coexistence of multiple sources, absorbing the load and PV fluctuations and most importantly reducing the DG run time. The DG is simulated using the grid supply. This also demonstrates the excellent response of the ZBM in brown sites (where there is no reliable grid support). This application is recognised to be of crucial importance for system integrators globally, as remote Base Telecommunication Stations (BTSs) must be powered at all times when a reliable source of energy is not available. This article covers the systems technical specifications, test conditions and criteria, test data analysis and conclusions. 2. System Specification The key features related to RedFlow ZBM Telco system are listed below: the BTS load is 1kW and must be supported at all times (continuously 24/7) two ZBMs (48V, 200Ah) are connected in parallel to the existing DC bus the solar power (PV) available is 1kWp, 20 inclination, facing NE the power electronics consists of a bank of rectifiers (RECT, totalling 4kW) set at 56V and one solar controller (MPPT, 3kW) during the day (from 6:00 to 18:00, 12 hrs), the solar and the two ZBMs support the load until sunset during the night (from 18:00 to 6:00, 12 hrs), the generator turns on and, while supporting the load, charges the ZBM at approximately 1.4kW per ZBM, totalling 2.8kW The system is shown in the following single line diagram (see Figure 1). Figure 1: RedFlow telco system single line diagram Page 2 of 8

This shows: diesel generator run time reduces by 50% with no BTS downtime the successful integration of the ZBM in existing telco systems at - 48V using renewables the compatibility of the ZBM with standard off-the-shelf power electronics (see Figure 2) utilisation of the 100% depth of discharge (DoD) capability of ZBM batteries to successfully integrate renewables in a standard Telco system Figure 2: RedFlow telco demonstration system installed in a powder-coated steel cabinet showing the ZBM at the bottom and power electronics above. Another ZBM is accommodated in another adjacent cabinet. 3. Test Conditions and Criteria The demonstration system is setup at RedFlow s facility in Brisbane, Australia. The power electronics and one ZBM are installed in an outdoor cabinet. The other ZBM is accommodated in another adjacent outdoor cabinet. The test ran between July and August 2014. Some key ambient parameters in August are given in Table 1 below. Table 1: Ambient parameters in July and August in Brisbane, Australia [1] Month Mean maximum Mean minimum Mean daily temperature ( C) temperature ( C) sunshine (hours) July 20.6 9.5 7.3 August 21.7 10.0 8.4 The average temperature swing is therefore more than 10 C with daily temperature extremes that can be even more than 23 C apart in July and more than 19 C apart in August. The ZBM is expected to be insensitive to this change of ambient conditions due to the large thermal mass provided by the 100 litres of water based electrolyte stored in the tanks. [1] Bureau of Meteorology, Australian Government. 2014. Page 3 of 8

One digital timer (TM-619) is utilised to simulate the generator/grid s availability in the event of: A sudden blackout of the grid; or Maximum utilisation of the DG when it is used and to minimise the DG run time (and hence reduce diesel consumption and the need to replenish the diesel). The timer is set to close the contact from 18:00 to 6:00 (12 hours) every day which provides power supply to the rectifiers (4 x 1kW modules) in order to charge the ZBMs and support the BTS load during the night time. During the day (6:00-18:00, 12 hours), the BTS load is supported by 1kW solar and two ZBMs (N+1 deployment). The installed PV system of 1kW is estimated to generate an average of 4.2kWh energy per day which can be added to the 8kWh from the charged ZBMs. A total of 20kWh ensures the 1kW BTS load is supported continuously without any downtime. N+1 ZBM deployment ensures there is always an active ZBM connected on the DC bus so the other ZBM can enter the maintenance cycle at any time with no disruption. 4. Test Data Analysis Approximately one-week of logged data is shown below in Figure 3. From this, the following observations can be made: The DC bus voltage (thick red line) is continuously supplied to the load within a range approximating -48V to -57V Even though one of the ZBMs entered its maintenance cycle (one every 5 days) the DC bus voltage is still maintained above the operating limits The batteries State of Charge (SoC) curves show the 100% DoD with the batteries fully charged in the morning and completely discharged during operations The two ZBMs connected in parallel on the bus do not interfere with each other and no current flows from one ZBM to the other. This simplifies the design and reduces the selfdischarge rate of the system The batteries temperature did not change significantly during charging and discharging cycles. This is remarkable considering that the temperature swing between night and day is more than 10 C which is not visible in the reported graph The solar contribution is clearly visible in the voltage curves which show an increase during the Sun hours (solar supporting the load and charging the ZBMs). Alternatively, the discharge rate reduction during Sun hours can be clearly seen in the SoC curves: this demonstrates that the ZBM discharge slows down due to the solar contribution Page 4 of 8

Figure 3: Test data The result of the test exceeded expectations with the following points observed: Using a ZBM has allowed us to integrate renewable generation in a standard Telco site where there is a diesel generator or an unreliable grid supply; The ZBM can be charged by the solar (or any other renewable source) as long as the power is supplied within the limits of the Telco DC bus. This can be easily achieved by using standard Telco power electronics as demonstrated in this application. Two or more ZBMs can be connected in parallel to support the DC bus at the same time. No interference and self-discharge is experienced. This means that longer blackouts or shorter DG run times can be achieved. The batteries absorb all the fluctuation and intermittency of the renewable generation or the load. This can be an advantage with less regular/stable sources of power (wind) and/or loads. The 50% run time reduction of the diesel generator can be easily achieved with N+1 ZBMs deployed. It must be noted that if more solar power is available the run time reduction can be extended further. Redflow internal tests confirmed a reduction up to 80% with standard weather conditions. In the case of the complete discharge of the batteries, the ZBM suffered no degradation and the system was restored as soon as power is supplied again. The reduction of the diesel generator run time has the following advantages: o significant fuel cost savings o reduced operating expenses due to less servicing, maintenance and BTS down time o the removal of lead acid batteries; o diesel generator life time is extended and servicing interval time extended; Greenhouse gas emissions are also reduced when renewables are involved. Page 5 of 8

Extended tests performed over a month, proved the reliability of the system and the ZBM has a warranty of 12 months. The experimental data has been inserted into specific modelling software developed by Redflow in order to estimate the performance and savings in real Telecommunication sites powered by diesel generators. Real application data such as generator size, fuel cost and maintenance cost/hours, have been taken into consideration in the computation. The results shows that the Redflow ZBM can effectively solve the problem of renewables integration and can provide immediate savings and a good return on investment in a multitude of cases. The following table summarise the outcomes of the business case evaluation for 4 different Telco sites in which Redflow proposed its battery be deployed. Load (kw) Table 2: Financial analysis of RedFlow telco system Solar (kw) Number of ZBMs Installed Diesel Generator Off Time (%) Cost Reduction per Year (USD$) Payback Time (years) 1 1 2 50% $23,584 0.99 490% 1 5 3 80% $27,568 2.26 752% 2 3 3 50% $24,220 1.72 292% 2 5 5 80% $26,515 2.92 253% Return on Investment (%) A typical installation of ZBM batteries in an existing Telco site is represented in Figure 4 below. As shown, the ZBMs can be connected directly to the DC bus replacing the existing lead acid batteries. Figure 4: Typical Redflow telco installation Page 6 of 8

5. Conclusions The integration of the RedFlow ZBM battery with standard Telco DC power electronics, renewables and grid/generator supply has been successfully demonstrated. With its 100% DoD, extended life, plastic construction and extremely wide temperature operating range, the ZBM proved to be the best choice for Telco sites experiencing unreliable power supply either from the grid or from DGs. The use of the ZBMs to reduce the DG run time generates further savings by reducing the frequency of DG maintenance/servicing (operating expenses). It also results in the DG operating at the most efficient point of the load/consumption curve. Furthermore, it can be expected that the DG run time reduction will be maximised by using larger PV installation coupled with matched ZBM energy capacity. Page 7 of 8