Installation, Operation and Maintenance Instructions

Similar documents
Installation, Operation and Maintenance Instructions

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

PERMANENT MAGNETIC AND RARE EARTH

Installation, Operation and Maintenance Instructions

120 VOLT ELECTRIC POWERED SINGLE COMPARTMENT SUMP SUCKER

UNIMIX EM. Operations Manual. Supplied by:

3 PHASE ELECTRIC POWERED DUAL COMPARTMENT SUMP SUCKER

Installation, Operation and Maintenance Instructions

20 HP LP GAS POWERED DUAL COMPARTMENT YELLOW BELLIED SUMP SUCKER

INSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF PPE SOUTH

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7

Installation, Operation and Maintenance Instructions

WARCO CHEMAG SERIES GH FILTERS

Tube Producing Conference September 23 rd 2013

BELT CONVEYORS. Installation, Operation and Maintenance Instructions MJ-2800B

20 HP LP GAS POWERED SINGLE COMPARTMENT SUMP SUCKER

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

UNIT VIBRATOR MODELS 60U AND 70U

SOLVENT BORNE UNITS WITH WATER BORNE PAINT UNI-RAM CORPORATION ONTARIO CANADA

Operating and Assembly Manual

Typical Machine Tool Coolant Purification Unit Installation and Operating Manual Note: MSR provides a custom manual for every application

Congratulations PRE-OPERATION SETUP

FILTERBOSS COMMANDER TROUBLE-SHOOTING GUIDE ALWAYS FOLLOW MFG DIRECTIONS AND USE YOUR OWN JUDGEMENT

Installation Manual. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL

ACF Operation Manual

#9040 FUEL TANK SWEEPER

Product Engineering Bulletin

Installation, Operation and Maintenance Instructions

Model 858-RH. Operating and Assembly Manual. Palmor Products Inc Serum Plant Road Thorntown, IN 46071

Installation, Operation and Maintenance Instructions

Operating and Assembly Manual

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

PRODUCT OPERATING MANUAL

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

VDF (Vortex Dynamic Filter) Instruction Manual CL-MR-series models

Operating and Assembly Manual

Troubleshooting the Transmission Hydraulic System

OWS OPERATIONS & MAINTENANCE

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

M-3025CB-AV Fuel Pump

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

(3) (4) (6) (5) (10) (9) (8) (7)

OPERATION MANUAL MCX-2HD Multiple Coolant Exchanger

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

Model 452-DIC/DH. Operating and Assembly Manual

INSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF PPE SOUTH

OPERATION MANUAL MCX-2F Multiple Coolant Exchanger

MODEL 4470GX. Ideal for grinding, honing, light metal removal.

MICRO-AIR DUST COLLECTOR Installation and Operation Manual MODEL RP6-2, RP-3, RP8-2 & RP-3

Operating and Assembly Manual

To ensure proper installation, digital pictures with contact information to before startup.

Operating and Assembly Manual

Table of Contents. Safety Assembly Pre-operation / Starting. 7. Operation.. 8. Maintenance. 9. Storage 10

Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System

KLW4000D Multi-Port Power Pack

Types and 52.20, Specialized test procedure Milk receiving and milk pick-up metering systems

1BGrease Traps and. Frequently Asked Questions About Grease:

Portable Filter Carts Models 5MF and 10MF

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

Air / Hydraulic Pump

SOLID/LIQUID SEPARATION AND COALESCING SYSTEMS

ICS Integrated Cleaning System. Rechargeable Battery

Cleaning Systems Inc. 2 P Rev:03

OPERATION AND PARTS MANUAL

MicroCoat Lubrication Systems

Operating instructions Form no safety definitions

Warning and Safety Precautions

MODEL MC1500 Installation and Operation Manual Important:

MODEL 565CKG Operating and Assembly Manual Midwest Equipment Manufacturing, Inc Serum Plant Road Thorntown, IN 46071

MOTORVAC. BrakeVac-II. MODEL NUMBER Brake Fluid Service System. Operator Manual MotorVac

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

P239-1 Supply Pumper Instructions

BrakeVac-II Brake Fluid Service System

Oil Pump Models L 5016, L 5116 & L 5132

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

Battery Powered Hydraulic Pump; Kit PN [ ]

Technical Service Bulletin Cooling System Flush Procedure

Installation, Operations & Maintenance

A D J U S TA B L E O I L D R A I N OWNER S MANUAL

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

CENTRAL SLURRY SYSTEMS Model 915

Marine Fuel Filtration Marine 800 Series

Routine Compressor Maintenance

Operating and Installation Instructions

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Grease Collection and Logistics for Small Operations. Michael R Mullins DieselGreen Fuels Austin TX

Installation and Operating Instructions. Magnetic band conveyer

Model G14SD Vapor Management System

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

WEBER CARBURETOR TROUBLESHOOTING GUIDE

Operating and Assembly Manual

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

Transcription:

FJ-408A Installation, Operation and Maintenance Instructions CS SS Coolant ecycling SYSTEM WITH COALESCE EIEZ MAGNETICS HEADQUATES: 2200 ASBUY OAD, EIE, PA 16506 1402 U.S.A. WOLD AUTHOITY IN SEPAATION TECHNOLOGIES

Introduction This manual describes Eriez CS SS Coolant ecycling System with Coalescer. A careful reading of these Installation, Operation and Maintenance Instructions will assure the most efficient and dependable performance of this equipment. Please include the model and serial number found on the nameplate with any correspondence concerning your CS SS Coolant ecycling System with Coalescer. If there are any questions or comments about the manual, please call the factory at 814-835 6000 for CS SS Coolant ecycling System with Coalescer assistance. Safety Information To avoid possible injury, read manual for full operating procedures before attempting operation of the CS System. Wear safety goggles to protect eyes from splashing liquids when transferring coolant into or out of the clean or dirty coolant tanks. This is important, even if the fluids are not caustic or otherwise harmful. Metal particles suspended in the liquid could still cause serious eye injury. Immediately clean up any spilled coolant to avoid slippery floors and dangerous falls. DO NOT use this unit for solvents, flammable (low flash point) or other volatile liquids; use only for water-soluble coolants. This unit is to be operated and maintained by authorized personnel only. CAUTION Safety labels must be affixed to this product. Should the safety label(s) be damaged, dislodged or removed, contact Eriez for replacement. 2018 EIEZ MAGNETICS ALL IGHTS ESEVED 2

Installation 1. Place the CS System in the desired location. The system can be placed with the back side against a wall; leave a 3' (1 m) wide aisle in the front and on both sides to provide access to the various components. The system should be leveled at the time of installation. 2. The Coolant Proportioner concentrate draw tube is removed prior to shipment to prevent damage or loss and therefore, must be installed as follows: Connect the Coolant Proportioner concentrate draw tube to the lower valve screw on the pump head. (efer to Coolant Proportioner manual.) 3. Plumb the inlet water supply to the system. A 3/4" (19 mm) supply line with a minimum of 30 PSI (2.1 bar) is required. If you do not have a deionizer, the maximum allowed water line pressure is 60 PSI (4.1 bar). 4. Plumb a line for shop compressed air to the air filter/regulator that is located on the side of the control panel. A minimum of 50 PSI (3.5 bar) and a maximum of 100 PSI (6.9 bar) of air pressure is required. 5. A single 115-volt electrical drop must be made to the system s control panel. 6. Make sure the float switches have had the packing straps removed and allow them to hang straight down into the tanks. 7. Place a drum of coolant concentrate next to the CS System and near the Coolant Proportioner. Insert the weighted end of the draw tube (refer to Step 2 above) into the 3/4" (19 mm) bung opening of the drum. Insert the low level drum switch assembly, which was factory-wired to the system, into the 2" (50 mm) bung opening of the concentrate drum. 8. Place an empty 55-gallon drum or other suitable container next to the system to collect the discharged tramp oils. Connect a hose (supplied) or hard plumbing to the tramp oil outlet on the Coalescer and direct this to the drum. Safety Information To avoid possible injury, read manual for full operating procedures before attempting operation of the CS System. Wear safety goggles to protect eyes from splashing liquids when transferring coolant into or out of the clean or dirty coolant tanks. This is important, even if the fluids are not caustic or otherwise harmful. Metal particles suspended in the liquid could still cause serious eye injury. Immediately clean up any spilled coolant to avoid slippery floors and dangerous falls. DO NOT use this unit for solvents, flammable (low flash point) or other volatile liquids; use only for water-soluble coolants. This unit is to be operated and maintained by authorized personnel only. ecycling Typical coolant recycling with a HydroFlow CS System follows a predetermined process that is repeated for each machine tool sump: Operator fills clean compartment of the Sump Cleaner (purchased separately from the CS System) with clean, recycled coolant from the clean coolant holding tank on the system. Operator transports the Sump Cleaner to the machine tool and vacuums the dirty coolant, chips, and swarf into the dirty compartment of the sump cleaner. When machine tool sump is clean, operator immediately fills the sump with clean coolant stored in the clean compartment of the sump sucker, a coolant cart, or through overhead piping. Operator transports dirty coolant back to the system and discharges it into the system for recycling. CS SS Coolant ecycling System 3

Operation Pump dirty coolant that has been filtered through a Sump Cleaner filter basket, or through another suitable means of filtering out the metal chips, dirt, and fines, into the dirty tank of the system by connecting the sump cleaner hose to the system. CAUTION DO NOT TY TO ECYCLE ANCID COOLANT. ancid coolant (EXTEMELY BAD SMELLING) cannot be recycled and will cause contamination of the other non-rancid coolant in the plant. NOTE: Filtration of the solids from the dirty coolant is very important. Proper filtration minimizes the amount of solids build-up in the bottom of the dirty tank and in the Coalescer. Make sure the coalescer tank 1" ball valve is closed. Make sure the floating skimmer is placed in the dirty tank. The center fluid intake should be set so it is just below the surface of the coolant. You want to see a slight swirl of fluid going into this port. But you do not want to see an open vortex in the center as that means you are sucking in air which can cause foam in the coalescer. Turn on the dirty coolant feed pump to begin processing the dirty coolant. The pump will collect the coolant and tramp oils with the floating oil collector, and pump the fluid into the Coalescer where the separation of coolant and tramp oils will occur. Adjust the tramp oil discharge in the Coalescer so that the surface of the Grey PVC discharge pipe is 1/8"-3/16" above the coolant level in the tank. As tramp oils separate from the coolant they will float on top of the coolant in the tank. When the tramp oil level is high enough, they will automatically drain out of the tank through the tramp oil discharge port. It is normal and preferred to have a layer of tramp oil in the tank. The thicker the layer of tramp oil that is allowed to form, the less coolant will be discharged with the tramp oils. The discharge line of the coalescer is plumbed to the clean tank. Many coolants need more than one pass through the coalescer to remove all free tramp oils. A crossover is installed between the clean tank and the dirty tank to allow the fluid in the clean tank to flow back into the dirty tank for reprocessing. The coalescer will operate all the time unless a high level is achieved in the clean tank and the high level float switch trips. Periodically check the tramp oil drum to prevent overfilling. emove the full drum and replace with an empty drum. Arrange to have the full drum of tramp oil hauled away or disposed of properly. The Coolant Proportioner will premix coolant concentrate with water at a set ratio. The Coolant Proportioner is connected electrically to the mid level float switch in the dirty coolant tank, the low level drum float switch and the solenoid valve on the downstream side of the Coolant Proportioner. The Coolant Proportioner will automatically turn on when the level in the dirty tank falls below the float switch, unless the concentrate drum is empty. The Coolant Proportioner will now mix the coolant concentrate with water at the desired ratio. This fresh coolant will mix with the recycled coolant in the clean coolant tank to provide a source of coolant for the plant. The mixing of fresh coolant with recycled coolant will replenish any part of the coolant that may have been depleted in the machining process and will reset the concentration to the desired ratio for the plant. (efer to the Coolant Proportioner manual for operating and maintenance instructions.) The Coolant Proportioner automatically turns off when the coolant level in the dirty tank has reached the level of the float switch, or when the concentrate drum is empty as indicated by the low level drum float switch. When the concentrate drum is empty, the low level drum switch illuminates a light on the control panel to indicate this condition. Connect a full drum of concentrate in the same manner as done in Step 7 of the Installation instructions. OPTIONAL COOLANT POPOTIONE LEVEL SENSO CONTOLS Some customers need more make up coolant than what the standard mid-level float switch will allow the Coolant Proportioner to make up. For those customers, an optional float switch selector switch is provided. This switch on the control panel is wired to both the clean tank mid-level float switch and the high-level float switch. If more make-up coolant is needed, place the Coolant Proportioner SHUT OFF selector switch in the high level position. The Coolant Proportioner will then fill the clean tank up to the high-level float switch and then shut off. If more make up coolant is not needed, keep the Coolant Proportioner SHUT OFF selector switch in the mid-level position. 4

OPTIONAL PEFILTE Set up: Be sure a filter cartridge or bag has been placed in the filter housing; refer to the filter manual for instructions. Make sure the filter housing drain is closed. Open the air vent valve on top of the filter housing by loosening the black needle valve two full turns, or remove it entirely. Adjust the air pressure regulator on the air feed pump to 60-80 PSI. Look at the pressure settings of the two pressure gauges before and after the filter housing. When the pressure gauges show a 35 PSI pressure drop across the filter housing, the filter cartridge or bag must be changed. To change the filter cartridge: Shut electric power off by turning the main electrical power off by turning the main disconnect handle to the off position. Close the manual dirty coolant feed valve to the coalescer; open the filter housing drain valve and drain the coolant from the housing. Change out the filter cartridge; refer to the filter manual. emove clean coolant from the clean tank with a Sump Cleaner or pump. Connect the Sump Cleaner hose to the clean tank port using the quick-disconnect fitting. Turn the sump cleaner on and turn to the suction mode to fill the sump cleaner with clean coolant. NOTE: This should only be done with a twin compartment sump cleaner, with a dedicated clean tank, to ensure that the clean coolant is not contaminated by any dirty coolant in the sump cleaner. OPTIONAL CLEAN COOLANT DISTIBUTION PUMP Your HydroFlow CS System may have been fitted at the factory with a pump on the clean coolant tank. This pump can be used to fill a clean coolanttransporting unit, such as a coolant cart. If sized properly, this pump can be plumbed throughout the plant with clean coolant drops at the machine tool sumps. If you do not have a factory-installed pump, you can add one at any time. Contact your HydroFlow representative for particulars. Periodically check the amount of solids that have settled out and accumulated in the dirty tank. emove solids as often as possible. The Sump Cleaner can be used for cleaning out this tank. Periodically check the amount of solids that have settled out and accumulated in the Coalescer. emove the plate packs and use the Sump Sucker to clean out these fines. Operating Tips Most coolant recycling programs work best when each machine tool is recycled well before the coolant needs to be dumped. Pick a time mid way of the time cycle observed before implementing recycling. If the fluid was dumped every 6 months, the fluid should be recycled every 2 to 3 months. Some machine tools will require recycling more often and others can go longer between pump outs. This schedule can be tailored for your plant to account for these differences. In most cases, a single pass through the Coalescer will remove the free-floating tramp oils. If one pass does not remove enough tramp oil, the CS System is equipped with a crossover between the clean and dirty tanks to allow the coolant in the clean tank to flow back to the dirty tank where it will be fed to the Coalescer for additional passes. If multiple passes through the Coalescer still do not remove enough tramp oil, it is an indication that the tramp oil has become emulsified into the coolant. Using a high-speed disc bowl centrifuge (available as an option or as a retrofitted component of the CS System), to remove this tramp oil. The centrifuge s rotating bowl applies over 6000 G s to the coolant and will remove 99.5% of the tramp oil in one pass. If a high-speed disc bowl centrifuge is not economically feasible, investigate a change in coolant. Your local vendor can assist you in selecting a coolant that will not only give you good performance at the point of cut, but also reject the tramp oils to enable the system to perform as expected. CS SS Coolant ecycling System 5

Maintenance efer to the Owner s Manual for maintenance of the transfer pump (See Appendix). A periodic check of the system s overall condition is recommended. epair or replace damaged components. Consult with HydroFlow Filtration and Fluid ecycling as necessary. Our engineers and service technicians can be reached at 814-520-8545. Trouble Shooting efer to the Coalescer Owner s Manual (See Appendix) for problems specific to those components. Complaint Possible Cause Solution 1. Pump does not run 1. No power to pump 1. a. Check that air is turned on at the system 2. b. Check solenoid on air line at control panel 3. Pump does not transfer Fluid 2. a. Clogged floating skimmer 2. b. Clogged pump 2. a. Inspect for blockage; clean skimmer 2. b. Inspect pump; clean, refer to pump Owner s Manual 4. Float switches do not Operate 3. a. Electric power disconnected 3. b. Float switches faulty 3. a. Check connection; reconnect if necessary 3. b. Check float switches for continuity in latched state; replace if faulty 6

DA CH I CS with Coalescer Electrics LOW LEVEL CONCENTATE MONITO 1FL MID LEVEL DITY TANK 2FL C3 16 [406] 10 [254] C3 1SV 1SV C1 C1 C1 HI LEVEL CLEAN TANK 3FL LOW LEVEL DITY TANK 4FL STOP STAT 17 1/4 [438] SYSTEM HIGH PUMP ON G STAT C2 B LOW LEVEL 16 [406] TOP STAT C2 C2 2SV STOP C2 2SV G G C3 C3 C3 16 [406] 10 [254] 9 5/16 [236] SYSTEM HIGH PUMP ON LOW LEVEL G 17 1/4 [438] STAT B 16 [406] GL GB ~ GOUND LUG ~ GOUND BA TEMINAL TIT SH FO STOP ~ FIELD DEVICE D SC CS SS Coolant ecycling System 7

8

TITLE WOLD AUTHOITY IN ADVANCED TECHNOLOGY FO MAGNETIC, VIBATOY AND METAL DETECTION APPLICATIONS WOLD HEADQUATES, EIE, PA, USA OUTLINE FO D. BY TAD DATE 01/28/14 SCALE 7/64 ODE # 275008 E.. # PIO EF NEXT ASS'M 4N-201400699 DAWING NUMBE EVISION INCHES [MILLIMETES] 0 DSIZE i2013* TITLE WOLD AUTHOITY IN ADVANCED TECHNOLOGY FO MAGNETIC, VIBATOY AND METAL DETECTION APPLICATIONS WOLD HEADQUATES, EIE, PA, USA OUTLINE FO 9 D. BY TAD DATE 01/28/14 SCALE 7/64 ODE # 275008 E.. # CS SS Coolant ecycling System NEXT ASS'M 4N-201400699 PIO EF DAWING NUMBE INCHES [MILLIMETES]

10

11 CS SS Coolant ecycling System

HydroFlow, Eriez and Eriez Magnetics are registered trademarks of Eriez Manufacturing Co, Erie, PA 2018 Eriez Magnetics All ights eserved World Authority in Separation Technologies Headquarters: 2200 Asbury oad, Erie, PA 16506-1402 U.S.A. Telephone: 814-835-6000 Fax: 814-838-4960 Web Site: http://www.eriez.com e-mail: eriez@eriez.com Manufacturing Facilities: AUSTALIA BAZIL CANADA CHINA INDIA JAPAN MEXICO SOUTH AFICA UNITED KINGDOM UNITED STATES 118-AHA-Web EIEZ MANUFACTUING CO 2018 PINTED IN USA 12