Sensor Activated Lavatory Faucet Installation, Operation & Service Instructions Model Numbers Tools & Materials Need Help?

Similar documents
Allura. Widespread Lavatory Faucet SLW-4712 Installation and Service Instructions. Quick Install Guide Allura Widespread Lavatory Faucet, SLW-4712

Degas Shower Valve System 5400-X... Valve includes stops 5400-TRM... Trim only

Dia. Installation and Service Instructions. Tub-Shower Systems 3520-B, 3521-B, 3522-B Series

Lucetta. Shower-Hand Shower System, 4605 / 4600 Installation and Service Instructions. Visual Guide Lucetta Shower-Hand Shower System, 4605 (4600)

ETF-600 Sensor Operated Lavatory Faucet

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Degas. Installation and Service Instructions. Tub-Shower Systems S-5400, S-5401, S-5402 Series

Dia. S Shower Valve System. S-3500TS-X... Valve includes stops. Arm and flange 300S. Screwless escutcheon kit RTS-011, brass RTS-012, plastic

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Installation Instructions

Installation IMPORTANT! Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control

Installation Instructions

Optima ETF-600/ETF-610

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

INSTALLATION INSTRUCTIONS

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

INSTALLATION INSTRUCTIONS

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

PRE-PLUMBED SEWAGE SYSTEM

Installation Instructions

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

INSTALLATION INSTRUCTIONS STUDIO S

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

Installation Instructions

INSTALLATION INSTRUCTIONS PATIENCE

Installation Instructions

Installation Instructions

Installation Instructions Series Series

LIGATURE RESISTANT SENSOR FAUCET

Electronic Faucet - 591T Series

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Grid Heater Starting Aid (T000)

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Operating Manual for Hands-Free Wall Mounted Sinks Models 607D and 607D-0.5

INSTALLATION GUIDE. Rainier Coil Pull Down Kitchen Faucet PB-K01

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Operating Manual for Hands-Free Wall Mounted Sinks Models 504 and

BASYS Infrared Sensor Activated

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Automatic Sensor Tap Installation Manual

Installation Instructions

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

TWO HANDLE LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

LAWN SPRINKLER, IRRIGATION PUMP

Installation Instructions

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual

Model: SE-4020-CA Automatic Battery Charger

Installation Instructions

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

Installation Instructions

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

WORKHORSE. Assembly / Operation Instructions / Parts 15 GALLON TRAILER SPRAYER

INSTALLATION INSTRUCTIONS

Centrifugal Constant Pressure Control

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

ProFlo FatBoy

WORKHORSE. Assembly / Operation Instructions / Parts

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

ASSEMBLY and OPERATING INSTRUCTIONS Mission Oaks Blvd. / Camarillo, CA 93011

POST LANTERN ITEM # MODEL #39487 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Installation Instructions

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

WORKHORSE. Assembly / Operation Instructions / Parts

INSTALLATION GUIDE. Tenino Retro Pot Filler Hi-Rise Kitchen Faucet PB-K05

WORKHORSE. Assembly / Operation Instructions / Parts 15 & 25 GALLON SPOT SPRAYER

Installation Instructions Series

MrSteam ANSI. Residential Steambath Generator Systems Installation,Operation & Maintenance Manual MODELS: MS-65 MS-90 MS-150 MS-225 MS-300 MS-400

WARNING. Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill. Components: AWG (0.82mm) Wire-UL Approved

Central Brass C O M P A N Y. A Division of Pioneer Industries, Inc. Installation Guide

Installation Instructions

WORKHORSE PSE. Assembly / Operation Instructions / Parts

SERIN MONOBLOCK LAVATORY FAUCET with

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

FUNTRONIX SCORE-N-TIME TM ULTRA-LARGE PORTABLE BASEBALL SCOREBOARD OPERATING MANUAL. Model SNT-800BB

AMEREC STEAMBATH GENERATOR (MODEL: AV2, 2KW/120 VOLT) SAVE THESE INSTRUCTIONS

Installation For Service Only

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

WORKHORSE. Assembly / Operation Instructions / Parts 25 GALLON TRAILER SPRAYER

F3000-B2B, F3000-B2M FILTRATION SYSTEM INSTRUCTION MANUAL

INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS

Analog Condensate Monitor Instruction & Maintenance Manual

RICE HYDRO, INC. - MANUFACTURER'S OPERATING INSTRUCTIONS TR-SERIES MODEL TEST PUMPS FOR WARRANTY REGISTRATION CALL:

PowerFLO 5800/5900 Series

SUBMERSIBLE PUMP HSE RANGE

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

Additions, Revisions, or Updates

INSTALLATION INSTRUCTIONS

Installation Instructions

MODEL CJ-200E CoilJet Portable HVAC Coil Cleaning System

Installation Instructions

Installation Instructions

ITS-50R TRANSFER SWITCH OWNER S MANUAL

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

Transcription:

Ultra-Sense Sensor Activated Lavatory Faucet S-6080-AC-12V-SSUP S-6080-ACM-12V-SSUP Installation, Operation & Service Instructions Model Numbers S-6080-AC-12V-SSUP Single supply sensor faucet and AC wall plug-in transformer S-6080-ACM-12V-SSUP Single supply sensor faucet for multi-faucet installations with 10' DC power cord Tools & Materials 2.5 mm (included) Solenoid valve removal wrench (included) Need Help? Symmons customer service: P: (800) 796-6667, F: (800) 961-9621 gethelp@symmons.com Mon - Fri 7:30 am - 6:00 pm EST www.symmons.com/service Technical help Product information Warranty policy For California Residents WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

Installation Instructions, S-6080-AC-12V-SSUP and S-6080-ACM-12V-SSUP Important! Prior to connecting the water supply, ensure supply lines are flushed. Particles can clog filter and result in malfunction. Excessive particles from supply lines may require installing a separate efficient filter. Step 1 Attach faucet to deck (1 hole) Single hole mount without deck plate Step 2 Connect power and supply line Symmons MAXLINE 7-210 water temperature limiting valve shown for illustration only (not included) temp adjust HOT COLD 3/8" 1/2" strainer check/ adapter 120 VAC power outlet tempered supply line finished deck front view Step 3 Test operation & check for leaks Step 1 Attach faucet to deck (3 hole) Three hole mount with deck plate finished deck front view Page 2

Multi-Faucet Installation Instructions, S-6080-ACM-12V-SSUP Installation Requirements The following items are not included and purchased separately: Switching Powers Supply, Model# S-6240-12V Power Supply supports up to eight faucets. Mounting strap and screws are included. Input: 100/240 VAC @ 1.0 amp Output: 12 VDC @ 3.3 amps max Termination Enclosure Box, Model # S-6244 Standard electrical termination enclosure or equivalent (6"H x 10"W x 4"D). Model S-6244 enclosure box may be purchased from Symmons or similar type from a local electrical supplier. Wire nuts - Secure wire connections using two wire nuts that can join (8) AWG #20 wires and (1) AWG #16 wire. Purchace from a local electrical supplier. Electrical Installation 100/240 VAC to 12 VDC power supply must be mounted in a electrical termination enclosure box with wire connection in accordance with local state electrical codes. Important! A licensed electrician must connect AC power source to power cord leading into termination enclosure. Page 3

Installation Multi-Faucet Instructions, Installation S-6080-AC-12V-SSUP and S-6080-ACM-12V-SSUP Reference Visual Guide illustration on page 3. Step 1 Install Faucets Install each sensor faucet per installation instructions on page 2. The maximum number of faucets DC power supply can support is (8) eight. Step 6 Connect AC Power Connect 100/240 VAC power source to wire ends of AC power cord. Note: A licensed electrician must connect AC power source to power cord. A 10 foot (20 foot optional) extended DC power cable is supplied with each faucet. Step 2 Mount Termination Box Mount box to a wall, under a sink or closet location. Ensure the furthest faucet is located within 19 feet (5.8 meters) of the termination enclosure. Wire color codes green....(protective earth) white...(neutral) black...(line) Plug AC power cord into power supply. Faucets may all activate for one cycle on initial power up. Dimensions Power Supply, S-6240-12V Step 3 Run faucet s extended DC power cable Plug extended DC power cable plug into each faucet s power receptacle. Run each extended power cable from faucet under the sink to the termination box. Feed cable through a strain relief and punched-out hole into the termination box. Avoid contact with water pipes and secure cable in accordance with state and local electrical codes. Step 4 Prepare power cable wire ends Faucet extended DC power cables Strip off a few inches of cable jacket and then strip each wire to expose copper ends. Power supply DC power cable Strip off a few inches of cable jacket and then strip ends of each wire to expose copper ends. Step 5 Connect DC power wires +12 VDC line - Connect each of the faucet s +LEAD #1 black wires to the power cables red wire. -RET (GND) line - Connect each of the faucet s - LEAD #2 black wires to the power cables black wire. Wire nuts - Secure wire connections using two wire nuts with size that can join (8) AWG#20 wires and (1) AWG#16 wire. 1-7/8" (47 mm) 1-3/16" (30 mm) 6 foot AC power cord Male Receptical AC Input (IEC 320 Inlet) Dimensions Enclosure Box, S-6244 6" (152 mm) 12VDC Output 4-3/16" (106 mm) 4 foot DC power cord 10" (254 mm) 4" (102 mm) Page 4 Note: Dimensions subject to change without notice.

Operation Sensor recognition range is factory preset at 1/2-4 inches Place hand under faucet, water will flow automatically for 10 seconds and shut off. Auto shut-off time is factory preset at 1/2 to 1 second Remove hands, water will stop automatically within 1/2 to 1 second. Security OFF after 10 seconds Faucet will automatically shut off after continuous water flow for 10 seconds. Faucet Repair Replacing Solenoid Valve (p/n SF-240) Remove old o-ring from valve body before replacing soleniod valve. Replacement solenoid valve will come with new o-ring installed to allow proper seal and prevent leaking from valve body. Troubleshooting No water flow Faucet is not receiving power from AC outlet. In multifaucet installations, faucet is not receiving power. Filter in strainer is clogged. Excessive clogged filter may require installing of separate efficient filter into supply line. Solenoid valve connector inside faucet is loose. Circuit board is faulty. Do not attempt repair, please contact Symmons customer service. Solenoid valve is faulty. Do not attempt repair, please contact Symmons customer service. Clean around photo cell sensor area or replace sensor. Water flow is weak Water supply stops are not fully open. Clean aerator and check strainer on end of supply line. Excessive clogging may require installing of separate efficient filter into supply line. Water flow from spout fails to turn off Sensing range may be too low. Clean around photo cell sensor area. Clean solenoid valve membrane or replace solenoid valve. Water temperature can t be adjusted Clean the check strainer on end of supply line. Clean or replace the mixer. Page 5 Faucet care Cleaning surface finish Block sensor with plastic cleaning cover to prevent faucet from turning on while cleaning. Clean finish area by using mild soap and water or non-abrasive cleaner and then rinse immediately. A non-abrasive wax may be used to preserve finish area. Precautions Ensure sensor is not damaged through impact or scratches. Ensure sensor is not blocked or disturbed by any object with its detection range. Ensure that no strong light source is aimed directly at sensor or through a mirror. Risk of Freezing When installing the faucet in a location where the temperature may fall below freezing, the entire system must be drained of water to prevent damage in freezing weather. Turn off water supply. Disconnect all flexible hoses. Drain all parts and hoses of water.

Dimensions Ultra-Sense Lavatory Faucet, S-6080-AC/ACM-12V-SSUP Note (1) Faucet shown with 4 inch centered deck plate. (2) Dimensions subject to change without notice. Deck plate, 6" (152 mm) Deck plate 2-1/2" (64 mm) 5-5/16" 19º (135 mm) Hole diameter 1-5/16" - 1-3/8" (33 mm - 35 mm) 1/4"-20 UNC 4" (102 mm) Strainer/adapter, 3/8" compression spacer 1/2" (13 mm) with spacer 1-1/8" (29 mm) without spacer 4-7/16" (112 mm) 19" (483 mm) Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 Copyright 2018 Symmons Industries, Inc. symmons.com gethelp@symmons.com ZV-3231 REV B 020518