The valves should be stored on a pallet or skid in a clean, dry warehouse. If the valves must be stored outside, the following apply:

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

K-LOK Installation, Operation, Maintenance and Troubleshooting

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

KEYSTONE SERIES GRF RESILIENT SEATED BUTTERFLY VALVES INSTALLATION AND OPERATION MANUAL

K-LOK Installation, Operation, Maintenance and Troubleshooting

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Butterfly Valve Type 57P

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Installation, Operation and Maintenance Manual for the HE Series

INSTALLATION, OPERATION AND MAINTENANCE FOR SERIES 500 K-FLO BUTTERFLY VALVES

PO Box 411 Berwick PA VALV

Operating & Maintenance Manual For Steam Conditioning Valve

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

KEYSTONE SERIES GR RESILIENT SEATED BUTTERFLY VALVES GRW/GRL INSTALLATION AND OPERATION MANUAL

Storage: The valves should be stored on a pallet or skid in a clean, dry location.

Sub Section Title Page No.

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

Installation, Operation And Maintenance Manual. Manual. For the 400 Series. ABZolute Seal. High Performance Butterfly Valve "Double Offset"

PNEUMATIC SLIDING VALVE

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Series 820 AWWA Butterfly Valves

Installation Operation Maintenance

846T/847T. Teflon R. Lining Valve INSTRUCTION MANUAL TEFLON R LINING VALVE STANDARD SPECIFICATIONS EXPANDED VIEW

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

Butterfly_Valve_Type57P

Butterfly Valves ASAHI AV VALVES

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

Rotary Damper. Type 57: 40~350mm (1 1/2 ~14 ) Type 56: 400mm (16 ) Type 75: 450~600mm (18 ~24 ) Contents

FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

Maintenance Information

Bray/McCannalok High Performance Butterfly Valve Operation and Maintenance Manual

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

POWER STEERING PUMP REBUILDING SPK101 Read instructions completely before removal & disassembly

McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

1988 Chevrolet Pickup V SUSPENSION - FRONT (4WD)' 'Front Suspension - "V" Series 1988 SUSPENSION - FRONT (4WD) Front Suspension - "V" Series

BRAKE SYSTEM Return To Main Table of Contents

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

NOTE: Visit our website at for video repair procedures, under the Tools section.

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance.

Bray/Mckannalok Butterfly Valve Series 40/41/42/43/44/45 Installation Manual Technical Bulletin No Date: May 2004/Page 1 of 6

Keystone Figure 85/86 Check valves Installation and Maintenance Instructions

Butterfly Valve Type 58 (PDCPD)

TRITEC (TT2) Instruction Manual

Butterfly valves Figure 56 Installation & Maintenance Instructions

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

REAR DRIVE SHAFT (3S GTE ENGINE)

Danfoss Butterfly Valve

CONTROLS RESILIENT SEATED BUTTERFLY VALVES 20/21, 22/23, 30/31, 3A/3AH, 31H, 31U, 32/33, 35/36, 36H. The High Performance Company

Fisher 657 Diaphragm Actuator Sizes and 87

DOUBLE OFFSET BUTTERFLY VALVE

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

V-SEGMENT SERIES V-Port Segment Control Valves (VS/VV/VM) Installation & Maintenance Manual

KEYSTONE. Hygienic butterfly valves model F250 & F251 Installation & Maintenance Instructions. 1 Contents 1 Contents 1

YOUR GLOBAL FLOW CONTROL PARTNER. BRAY/MCCANNALOK EN High Performance Butterfly Valve Operation and Maintenance Manual

GENESIS COUPE(BK) > 2010 > G 3.8 DOHC > Steering System

CLARKSON URETHANE KNIFE GATE VALVES FIGURE SU10R

Series 2200/2220 Control Valve. Operation and Maintenance SCOPE OF MANUAL MAINTENANCE DESCRIPTION VALVE INSTALLATION

IOM Manual. IOM Manual. Series 76/77.

I-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761

CHAS FRONT FORK FRONT FORK LEGS 4-45 FRONT FORK. Order Job/Part Q ty Remarks

Fisher Vee-Ball V150 and V300 NPS 14 through 24x20 Rotary Control Valves

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE

SUSPENSION - FRONT Toyota Celica DESCRIPTION ADJUSTMENTS & INSPECTION WHEEL ALIGNMENT SPECIFICATIONS & PROCEDURES WHEEL BEARING

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators

Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) User s manual. Air Release Valve. Air Release Valve for Water

Recommended BFV Installation, Maintenance & Repair Procedures Ultraflo 300 & 400 Series Valves

Heavy Duty Hoist WARNING. General Safety Precautions. Thank you for purchasing a

NYL Resilient Seated Butterfly Valves Operation and Maintenance Instructions

KTM Hindle Series 300 Ultra-Seal two piece metal seated ball valves Installation and Maintenance Instructions

Maintenance Information

GROUP 9 BOOM, ARM AND BUCKET CYLINDER

ACE VALVE COMPANY LIMITED

Transmission Overhaul Procedures-Bench Service

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

1.6L 4-CYL - VIN [E]

Globe Control Valve Series 1a

Rotary Damper Electric Actuated Type S

Instalation, Operation and Maintenance Manual

DESCRIPTION & OPERATION

Installation, operation & maintenance manual Integral Tie Rod Design

SECTION Front Drive Axle/Differential

USER INSTRUCTIONS. Valtek Valdisk TX3 Triple Offset Butterfly Control Valve. Installation Operation Maintenance. Experience In Motion

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

DF 47 DIFFERENTIAL REAR DIFFERENTIAL CARRIER ASSEMBLY REMOVAL

Model 8329 Table of Contents

Operation & Maintenance Manual 4900 Series Pipeline Injection Pumps Bulletin 150

Baumann 24000F Wafer Control Valve

Transcription:

Please read these instructions carefully - indicates that it may lead to injuries or damages on the properties. Warning - indicates that it may lead human body to serious injuries. Danger - indicates that it may lead human body to death. Technical data Flange accommodation: The Figure V11 is designed by JIS 5K/10K code Pressure rating: 5 kg/cm 2, 10 kg/cm 2 Temperature range: -40 C - 120 C Figure 1 Pipe flange bolt tightening torque Recommended torque Bolt size Nm M12 x 1.75 17 M16 x 2 41 M20 x 2.5 81 M24 x 3 139 M27 x 3 194 M30 x 3.5 281 M33 x 3.5 358 M36 x 4 481 Bolt size U.N.C Ft-lbs ⅝ 30 ¾ 50 ⅞ 80 1 123 1⅛ 195 1. Torques based on 100 Mpa induced stress in fastener threads. 2. Values are based on steel bolting well lubricated with a heavy graphite and oil mixture. 3. For cadmium plated fasteners multiply torque x 0.75. 4. For zinc plated fasteners multiply torque x 1.40. 5. Recommended torques are a minimum. For maximum torque multiply torque x 1.05. Carriage and storage Recommended torque 1. Carriage The valve shall be carried safely not to be impacted or affected by other object. Especially, the wheel of operator and disc edge shall be protected by any means. 2. Storage The valve shall be stored in the higher place which is able to prevent from being submerged in water and keep off from penetration of rainwater or cover it with waterproof cloth, which Keystone valve LLC. does not provide, to avoid being wetted. When worker installs the valve, remove the dust and extraneous substances after disassembling the pallet and protective cover. Installation The valves are shipped with flange surface protection. Before installing the valve, remove the protection. The valve should be installed in the slight opened position whether the gap between disc edge and body flange face is about 10 mm to insure that the seat and disc are not damaged during installation. Particular care should be taken with valves equipped with "single acting" actuators. Failure to insure proper handling may result in damage to the valve. If the pipe is lined, confirm that the disc rotation does not contact the lining during the opening stroke. Failure to confirm that the disc rotation dose not contact the lining may result in damage to the valve. The Figure V11 valves are bi-directional and will control flow equally well in either direction. www.valves.emerson.com 2017 Emerson. All rights reserved. VCIOM-02830-EN 14/05

Installation in new construction using welding type flanges 1. With the disc in the slight opened position, align and center the companion flange bolt holes to the body alignment holes. 2. Assemble the body and flanges with the flange bolting and make-up the bolting. 3. Using the flange-body-flange assembly for fit-up and centering to the pipe. 4. Tack weld the flanges to the pipe. 5. Remove the flange bolting and valve assembly from between the flanges. Do not finish weld the flanges to the pipe with the valve bolted between the flanges as this will result in serious heat damage to the valve seat. 6. Finish welding the flanges to the pipe and allow the flanges to cool completely before proceeding. Maintenance Routine maintenance or lubrication is not required. Be sure to be familiar with following facts before installing valves. Tie up with rope when handling the butterfly valve assembly for Figure V11. 1. Tie up feature with rope when handling the valve assembly vertically. (Figure 2) Lift the valve in the condition of tying upper neck with ropes. Tie up the front and rear side of valve with two ropes, because the rope may be removed when use one rope. 2. Tie up feature with rope when handling the valve assembly horizontally. (Figure 3, 4) Lift the valve in the condition of tying upper and lower neck with ropes. Beware that the rope on the lower neck may not be removed or valve assembly may not be tilted. Dismantling the valve from pipe (Figure 5) 1. Be sure that the fluid and pressure in valve and pipe must be removed before dismantling. 2. Close the valve. 3. Cut off the supply of the electric power, hydraulic or pneumatic pressure depending on the kinds of operators attached and disconnect the electric cable, hydraulic or pneumatic hoses. 4. Release the flange bolt in order to disassemble the valve assembly. Disassemble the operator ahead when necessary. 5. Dismantle the valve after open the flanges sufficiently using tools. 6. Disassembly the operator in the condition of fastening the valve assembly on vise. Warning Make sure that the fluid and hydraulic or pneumatic pressures in valve, operator and pipe are removed, and then dismantle the disc in the position of full close after taking safety measures. Figure 2 Figure 3 Figure 4 Danger Use the rope made by synthetic fiber only taking into account of valve weight and safety and pay attention that paint on the valve does not peel. When worker lifts the valve assembly, which is equipped hand wheel including gear box, in the condition of tying hand wheel with rope, he(she) shall comply with the specific method which manufacturer provides because the stem may be distorted or the cover may be damaged. Figure 5 2

Disassembly When assembling or disassembling the valve, workers have to be careful that each component including disc edge shall not be damaged. Disassembly of the valve, size NPS 2.5 to 34 (Figure 6) 1. Remove the disc screws and O-ring for the valves. 2. Open the disc. 3. Remove the stem by pulling it out through the valve top plate. 4. Remove the disc from the valve body by pulling or rolling the disc out of the seat bore. 5. Remove the seat by prying under both seat edges at one point, collapse the seat into the shape of a round bottom heart, and pull the seat out of the body bore. 6. Remove the bushing, packing and inspect for damage. Replace if needed. 7. Remove the bottom cover screws and spring washer (NPS 22-34). 8. Remove the bottom cover and O-ring (NPS 22-34). (NPS 22-34) { Bushing Figure 6 Packing Stem Body Seat Disc O-ring and disc screw O-ring and bottom cover Bottom cover screw and spring washer Disassembly of the valve, size NPS 36 to 72 (Figure 7) 1. Remove the disc screws and O-ring for the valves. (In case of NPS 48-72 valves, pull the taper pin out after removing the nut.) 2. Open the disc. 3. Remove the stem by pulling it out through the valve top plate. 4. Remove the disc from the valve body by pulling or rolling the disc out of the seat bore. 5. Remove the seat by prying under both seat edges at one point, collapse the seat into the shape of a round bottom heart, and pull the seat out of the body bore. 6. Remove the packing holder, O-ring and inspect for damage. Replace if needed. 7. Remove the bottom cover screws and spring washers. 8. Remove the bottom cover and O-ring. 8. Remove the upper bearing and lower bearing. O-ring (inner) Packing holder O-ring (outer) Stem Body Upper bearing Seat Disc Figure 7 O-ring and disc screw Lower bearing Bottom cover O-ring Lower bearing Spring washer Bottom cover screw 3

Inspection of valve components Figure 8 Figure 12 Inspect the body for any corrosion and damage. Inspect the seat for any wear and damage. Inspect around the disc edge for any scratch. If there is any scratch on disc edge, polish the edge with sandpaper. Use the electric powered wire brush in order to polish the disc edge. Use the lathe machine to finish polishing or sanding, when necessary. Assembly Assembly of valve, size NPS 2 to 20 1. Clean all components and settle the valve body on the vise. 2. Insert the packing and bushing to the upper side of the body. (Figure 8) 3. Bend the seat like the shape of heart and insert the seat in the seat pocket with adjusting the stem hole of seat to the stem hole of lower body. (Figure 9) 4. Adjust the stem holes in the body and seat hole by thrusting in and pulling out using stem or T-shape jig, and then thrust the stem into the stem hole with protruding the screwed part 10 mm. (Figure 10) 5. Apply silicon oil to the inner seat and adjust the upper stem hole of disc to the protruded screwed part of upper side. Then, push and insert the disc until the lower side of disc set to the lower stem hole. (Figure 11) 6. Drive the stem into the body until adjust the holes between stem disc and screw hole be matched using rubber hammer. And adjust the screw hole centre of stem by rotating the disc. (Figure 12) 7. Adjust the screw holes between stem and disc correctly using pin or screwdriver and fasten the screw tightly after inserting the O-ring onto the disc screw. (Figure 13) 8. Finish assembling the valve. (Figure 14) Figure 9 Figure 10 10 mm Figure 13 Figure 14 Figure 11 4

Install the valve assembly into the pipe 1. Fix the valve on the vise and install the worm gear box and actuator. 2. Check the condition whether the gap between disc edge and body flange is about 10 mm. (Figure 16) Figure 16 10 mm Figure 15 Assembly of valve, size NPS 22 to 72 (Figure 15) 1. Clean all components and settle the valve body on the vise. 2. Insert the packing and bushing at the upper side of body. In case of size NPS 36-72, insert the packing holder of which has O-ring. 3. Bend the seat like the shape of heart and insert the seat in the seat pocket with adjusting the seat hole of seat to the stem hole of lower body. In case of size NPS 36-72, insert the upper and lower bearings ahead prior to inserting seat. 4. Adjust the seat hole to the body hole by striking with rubber hammer, and then drive the stem into the stem hole with protruding the screwed part 10 mm using rubber hammer. 5. Apply silicon oil to the inner seat and adjust the upper stem hole of disc to the protruded screwed part of upper side. Then, push and insert the disc until the disc set to the lower stem hole using hoist or C-clamp. 6. Drive the stem into the body until the holes between stem and screw hole be matched using rubber hammer. And adjust the hole centre by rotating the disc. 7. Adjust the screw holes between stem and disc correctly using pin or drive. And fasten the screw tightly after inserting the O-ring onto the disc screw. (In case of size NPS 48-72, taper pin instead of disc screw. Fasten the nut at the back side after inserting taper pin.) 8. Fasten the bottom cover screws with spring washer after assembling the bottom cover of which O-ring has been inserted into the body. 9. Finish assembling the valve. Workers shall pay attention to the position of disc because disc edge may be damaged when the disc is opened more than the face of body flange, and the excessive torque may be caused by the distortion of seat when fasten the flange bolt in the state of entire closure. 3. Insert the valve after widening the flanges sufficiently. The gap between flanges shall be wider than the width of valve. When insert the valve in the condition of insufficient flange gap, the seat may be distorted or torn and cause the leakage. (Figure 17) 4. Adjust the valve alignment hole or tap hole to the flange hole, pass the bolt through the flange hole, alignment hole or tap hole and check the position of valve. Tighten the bolt with hand if there is no problem. (Figure 18) 5. Open the disc fully by operating handle in order to check whether or not the edge of pipe and disc edge contact each other. 6. After making sure of smooth operating of valve, fasten the bolts with the tool by the diagonal sequence in the condition of full opening. 7. Finish installing the valve assembly onto the pipe. (Figure 19) Do not use the flange gaskets. Figure 17 Figure 18 Figure 19 5

Trouble shooting guide Symptom Possible cause Resolution Valve opens only a few degrees and stops (It will not open to the full angle desired) 1. the valve is improperly aligned and improper installation 1. loosen the flange bolts, realign the valve with flanges and retighten the flange bolts to correct torque per ANSI requirement Leakage past the flange face 1. Flange bolts are not evenly torqued 1. loosen the flange bolts and tighten the flange bolts to correct torque per ANSI requirement 2. Improper flanges 2. Refer to flange accommodation on page 1 Leakage in the closed position (Leakage in the pipe line) The disc is not closing fully: 1. Actuator is not properly adjust 1. Refer to the adjustment procedures 2. Damaged seat 2. Replace seat 3. Line pressure exceeds valve s working pressure 3. Reduce line pressure to valve working pressure 4. Damaged valve disc 4. Replace disc Leakage at the valve stem 1. Seat stem hole or packing failure 1. Refer to valve disassembly procedures Water hammer 1. The valve is closing too quickly 1. Adjust the actuator Excessively high torque 1. Obstruction in the pipe line 1. Remove the valve from pipe line and remove obstruction 2. Valve stem or disc bent 2. return the valve to factory for disc or stem replacement (Check for water hammer or freezing of line material) 3. Scale build-up on stem or seat 3. Open and close the valve several times, operate the valve at least once a month, check the valve seat for deterioration 2017 Emerson. All rights reserved. 6