January 01 Vol. 1, Ref. No. [05] 1 Amperes 12- Table 12-99. Type Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Maximum Continuous Ampere 2-Pole 0 0 3-Pole 0 0 V AC Rated, 0V DC Complete Circuit Breaker Without Line and Load Terminals 2W 20W 2W 20W 00W 2W 3W 30W 3W 30W 00W 3W 4,8. 4,8. 4,8. 4,8. 4,8. 4,8. With Standard Line and Load Terminals Only 2 20 2 20 00 2 3 30 3 30 00 3 Factory sealed suitable for reverse feed application. Note: Instruction Leaflet/FRED 29C5 for Breaker Molded Case Switches Molded Case Switches are used as compact switches in applications requiring high current switching capabilities. Molded case switches are constructed of circuit breaker components and are of the high instantaneous automatic type. Molded case switches are listed in accordance with Underwriters Laboratories Standard UL 87. Table 12-. Molded Case Switches Maximum Continuous Ampere @ 40 C 2-Pole 3-Pole 4-Pole V AC Maximum, 0V DC Circuit Breaker Only without Line and Load Terminals 2WK 3,690. 2WK 3,690. 3WK 4,5. 3WK 4,5. 4WK 7,240. 4WK 7,240. Standard Terminals Only See Page 12-66 for Optional Terminals 2TA603K 2TA603K 3TA603K 3TA603K 4TA603K 4TA603K Factory sealed suitable for reverse feed application. Note: Molded Case Switch may trip above 0 amperes. Note: Instruction Leaflet/FRED 29C5 for Molded Case Switch 63. 63. 93. 93. 124. 124. Discount Symbol........................ CB-2 CAT.01.T.E
12-52 1 Amperes January 01 Vol. 1, Ref. No. [0518] Contents Description Page Product Description......... 12-52 Technical Data and Specifications......... 12-52 Dimensions/Weights........ 12-54 Product Selection........... 12-55 Product Description All Circuit Breakers are HACR rated. circuit breakers are available as individual components (Frame, Trip Unit, Terminals), or factory assembled complete breakers. circuit breakers with non-interchangeable trip units are suitable for reverse feed use. Typical Circuit Breaker Technical Data and Specifications Table 12-84. UL489 Interrupting Capacity s Circuit Breaker Type Interrupting Capacity (rms Symmetrical Amperes) (ka) Volts AC (50/60 Hz) Volts DC 240 277 480 1 0 12 C H CH 2, 3 C CC 0 0 Utilization category A circuit breakers. L/R = 8 milliseconds minimum. 2-pole circuit breaker or two poles of 3-pole circuit breaker. Incorporating Thermal-Magnetic trip unit only. % rated breakers. 50 50 22 22 22 30 30 Table 12-. IEC 947-2 Interrupting Capacity s Circuit Breaker Type Interrupting Capacity (Symmetrical Amperes) (ka) Volts AC (50/60 Hz) Volts DC 240 415 690 0 I cu I cs I cu I cs I cu I cs I cu I cs C H CH C CC 2, 3 0 0 Utilization category A circuit breakers. L/R = 8 milliseconds minimum. 2-pole circuit breaker or two poles of 3-pole circuit breaker. Incorporating Thermal-Magnetic trip unit only. % rated breakers. 75 75 13 13 18 18 CAT.01.T.E
12-54 1 Amperes January 01 Vol. 1, Ref. No. [05] Dimensions/Weights Table 12-87. Dimensions in Inches (mm) Width Height Depth 2, 3 4 8. (2) 11 (279).75 (274).75 (274) 4.062 (3) 4.062 (3) Table 12-88. Approximate Shipping Weight, Lbs. (Kg) Breaker Type Complete Breaker Frame Only Trip Unit 2 3 4 2 3 4 2 3 4, H, C 18 (8.172) 18 (8.172) (9.080) (9.080) (11.340) (11.340) 14 (6.6) 15 (6.8) (9.072) 3 (1.361) 4 (1.814) 5 (2.268) 12 CAT.01.T.E
January 01 Vol. 1, Ref. No. [0521] 1 Amperes 12- Product Selection This information is presented only as an aid to understanding s. It is not to be used to build s for circuit breakers or trip units. Table 12-89. Circuit Breaker/Frame ing System L D 3 6 0 0 F Circuit Breaker/ Frame Type H C C CH CC 2 = 2 Poles 4 = 4 Poles Circuit Breaker/ Frame Ampere 0 0 C = Copper Terminals F = Frame Only K = High Magnetic Molded Case Switch V = 50 C (Thermal-Magnetic Trip Units Only) W = Without Terminals X = Load Side Terminals Only Y = Line Side Terminals Only Table 12-90. Thermal-Magnetic Trip Unit ing System L T 3 4 0 0 T Trip Unit Type LT = Thermal Magnetic 2 = 2 Poles 4 = 4 Poles Trip Unit / Plug Ampere 0 0 T = Trip Unit Thermal-Magnetic Fixed Thermal Adjustable Magnetic V = 50 C Calibration (Thermal-Magnetic Trip Units Only) Table 12-91. OPTIM Circuit Breaker/Frame ing System L D 3 1 2 5 T 5 7 W Circuit Breaker/ Frame Type H C C CH CC Circuit Breaker/Frame Ampere 1 (Available on Model 50 only) 0 (Available on Model 50 only) Trip Type 2 = LSI (550 Only) 6 = LSIG 7 = LSIA Trip Model T5 = Model 550 T = Model 50 W = Without Terminals Table 12-92. Digitrip RMS 3 Trip Unit ing System L E S 3 6 0 0 L S P Trip Unit Type LES = Electronic 4 = 4 Poles Trip Unit Ampere LS LSI LSG LSIG P = % Protected Neutral on 4-Pole Trip Unit CAT.01.T.E
January 01 Vol. 1, Ref. No. [0627] Internal Accessories Alarm Switch 12-1 Table 12-298. K-Frame Alarm Switch of (1M and 1B) 18-Inch (7.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block 1 Left 2 Left B01 B05 B09 B12 B02 B06 B B13 Listed with Underwriters Laboratories, for field installation on interchangeable trip unit breakers under E64983. Standard mounting location. Standard mounting location leads exit rear of breaker. Note: Instruction Leaflet/FRED 29C182 B03 B07 B04 B08 B11 B14 A1L3LPK A1L3RPK A2L3LPK A2L3RPK A1L3LTK A1L3RTK A2L3LTK A2L3RTK Table 12-299. L- and M-Frames Alarm Switch of (1M and 1B) 18-Inch (7.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block 1 Left 2 Left B01 B05 B09 B12 B02 B06 B B13 Listed with Underwriters Laboratories, for field installation on interchangeable trip unit breakers under E64983. Standard mounting location. Standard mounting location leads exit rear of breaker. Note: Instruction Leaflet/FRED 29C183 B03 B07 B04 B08 B11 B14 A1L4LPK A1L4RPK A2L4LPK A2L4RPK A1L4LTK A1L4RTK A2L4LTK A2L4RTK Table 12-. N-Frame Alarm Switch of (Make and Break) 18-Inch (7.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block 1 Left 2 Left B01 B05 B09 B12 B02 B06 B B13 B03 B07 Standard mounting location. Standard mounting location leads exit rear of breaker. B04 B08 B11 B14 A1L5LPK A1L5RPK A2L5LPK A2L5RPK A1L5LTK A1L5RTK A2L5LTK A2L5RTK Note: Instruction Leaflet/FRED 29C184 Table 12-301. R-Frame Alarm Switch (RH only) of (Make and Break) 18-Inch (7.2 mm) Pigtail Leads Pigtail Leads 1 B05 301. A1L6RPK 301. 2 B12 605. A2L6RPK 605. A maximum of three ASL plug-in modules may be installed in a circuit breaker. Note: Instruction Leaflet/FRED 29C1 Discount Symbol......................... CB-2 CAT.01.T.E
12-164 Internal Accessories Auxiliary Switch January 01 Vol. 1, Ref. No. [0630] Table 12-314. L- and M-Frames Auxiliary Switch of (1a and 1b) 18-Inch (7.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block 1 Left 2 Left 3 Left A01 A05 A09 A12 A18 A17.. A02 A06 A A13 A03 A07 Standard mounting location leads exit rear of breaker. Not for use on 4-pole circuit breaker. A04 A08 A11 A14 A15 A16.. A1X4PK A1X4PK A2X4PK A2X4PK A3X4PK A3X4PK 6. 6. A1X4LTK A1X4RTK A2X4LTK A2X4RTK A3X4LTK 6. A3X4RTK 6. Note: Instruction Leaflet/FRED 29C123 12 Table 12-315. N-Frame Auxiliary Switch of (1A and 1B) 18-Inch (7.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block 1 Left 2 Left 3 Left A01 A05 A09 A12 A18 A17.. A02 A06 A A13 A03 A07 Standard mounting location leads exit rear of breaker. Not for use on 4-pole circuit breaker. A04 A08 A11 A14 A15 A16.. A1X5PK A1X5PK A2X5PK A2X5PK A3X5LPK A3X5RPK 6. 6. A1X5LTK A1X5RTK A2X5LTK A2X5RTK A3X5LTK 6. A3X5RTK 6. Note: Instruction Leaflet/FRED 29C124 Table 12-316. R-Frame Auxiliary Switch (RH only) of (Make and Break) 18-Inch (7.2 mm) Pigtail Leads Pigtail Leads U.S. 2 A12 605. A2X6RPK 605. 4 A19 900. A4X6RPK 900. A maximum of two auxiliary switches (any combination of 2a/2b or 4a/4b plug-in modules may be installed in a circuit breaker. Note: Instruction Leaflet/FRED 29C1 Discount Symbol......................... CB-2 CAT.01.T.E