HRYW Yanmar. Industrial Rental Towable Generator. Model: HRYW 25 T6. Genset Ratings. Key features. Ratings Range - 60Hz Operation 1800 rpm Diesel

Similar documents
Key features. Genset Ratings. Ratings Range - 60Hz Operation. Standby kw kva Prime kw kva

Key features. Genset Ratings. Ratings Range - 60Hz Operation. Standby kw kva Prime kw kva Sound Attenuation: at 7m / 23 ft

125ºC RISE PRIME RATING kw kva Amps kw kva Amps SJ 55 M6 4045TF UCI 224 G 120/ VOLTAGE L-N L-L

RENTAL DIESEL GENERATOR SET

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

HYW-20 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by SCANIA

Manufacture facilities: SPAIN FRANCE INDIA CHINA USA Subsidiaries: ITALY PORTUGAL POLAND GERMANY I SINGAPORE UAE MEXICO PANAMÁ I ARGENTINA

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Model: HHY 20 C T INDUSTRIAL RANGE Soundproof Powered by YANMAR

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Manufacture facilities: SPAIN FRANCE INDIA CHINA USA Subsidiaries: ITALY PORTUGAL POLAND GERMANY I SINGAPORE UAE MEXICO PANAMÁ I ARGENTINA

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by SCANIA

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

Generating Rates. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

DIESEL GENERATOR SET. 60 Hz FEATURES

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

13,000 Watt Diesel Generator AGi13P E

Generating Rates SERVICE PRP STANDBY. HR RANGE Soundproofed rental Powered by YANMAR

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

10,000 Watt Diesel Generator AGi9P E

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Container Powered by MITSUBISHI

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Open Skid Powered by MITSUBISHI

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

DIESEL GENERATOR SETS

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Power kva Power kw Rated Speed r.p.m Standard Voltage V 400 Available Voltages V 400/230 V Rated at power factor Cos Phi 0,8

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by VOLVO

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

45 KW / 55 KVA POWERED by

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by SCANIA

23 KW / 29 KVA POWERED by

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by SCANIA

APD-ULJ250. Standby Power

Generating Rates SERVICE PRP STANDBY. HR RANGE Soundproofed rental Powered by FPT_IVECO

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Model: HGK-310 T6 LPG INDUSTRIAL RANGE SoundProof Powered by WAUKESHA

Diesel generator set QSX15 series engine

Diesel generator set QSK23 series engine

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

Generating Rates SERVICE PRP STANDBY. PROFESSIONAL RANGE Soundproof Powered by YANMAR

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

STANDBY 200 ekw 250 kva

G80U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

55 KW / 69 KVA POWERED by

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

Diesel generator set QSK23 series engine

Rental Power 800 kw. Specification sheet. Description. Features. Options

Diesel generator set QSX15 series engine

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

WPS60/S EP Series. Features:

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

28 KW / 28 KVA POWERED by

WPS20/S EP Series. Features:

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

WPS100/S EP Series. Features:

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

80 KW / 100 KVA POWERED by

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

Transcription:

Genset Ratings Ratings Range - 60Hz Operation 1800 rpm Diesel Standby kw 22 kva 28 Prime kw 20 kva 25 Pictures may include optional equipment and/or accessories. Generator available with or without trailer Key features HIPOWER rental generators are an efficient, reliable and versatile source of power designed to operate in the most extreme working conditions. An unique combination of innovative materials and design features combine for easy user operation and dependable power you can rely on. The Genset features a heavy-duty Yanmar 4 cycle diesel engine certified by the Environmental Protection Agency (EPA) to conform to Tier 3-4Interim non-road emissions regulations, an AC high capability alternator regulated by a precise Automatic Voltage Regulator controlled and protected by our own auto-start CEM7 control panel available CANBUS communications including a powerful microprocessor and easy user programming. A heavy-duty constructed chassis supports the complete set. The generator is protected by a best-in-class sound attenuated enclosure designed for durability and extreme application. - 1 - Sound Attenuation: at 7m / 23 ft 57 dba Engine - generating set tested to ISO 8528-5. The Genset engine is certified by the Environmental Protection Agency (EPA) Tier 3-4 Interim non-road emissions regulations. The brushless, single bearing, 4 poles, 12-wire generator end, with automatic voltage regulator has broad range reconnectability. The Genset is CSA certified. Global product support. Operations and maintenance manuals. 1 Year Standard Warranty. Extended warranties are also available. HIPOWER reserves the right to modify any characteristic without prior notice. The technical indications described correspond to the information available at the moment of printing or editing.

Standard features Engine Industrial grade Tier 3-4 Interim Yanmar diesel Engine, 4 stroke, water cooled, provided with: Electric start 12V. Radiator with pusher fan. Standard water separator visible level fuel filter. Electronical governor. HWT/LOP senders. Medium duty 1-stage air filter with service indicator. Hot & rotating components (exhaust, fan, ) protections and radiator guards. Oil drain hand pump. Alternator Self excited, self regulated alternator. Insulation class H, IP23 Protection. Automatic Voltage Regulator (AVR-EBS) (+/-1%). Vacuum impregnation. Permanent Magnet Generator (PMG). Control Panel Digital microprocessor based control panel with remote start capability. CEM7 Auto-start control panel (2 wires). Engine protections: High coolant temperature (A), High coolant temperature by sensor (W), Low engine temperature by sensor (W), Low oil pressure (A), Low coolant level (A), Unexpected shutdown, Fuel level (W), Stop failure, Battery voltage failure (W), Battery charging alternator failure (W), Overspeed (A), Underspeed (A), Start failure, Emergency stop. Alternator protections: Over frequency (A), Under frequency (A), Over voltage (A), Under Voltage (A), Short-circuit (A), Unbalanced voltage (A), Incorrect phase sequence (A), Reverse power (A), Overload (A). Genset readings: Voltage among phases, Voltage among phases and neutral, Amperage, Frequency, Apparent power(kva), Active power (kw), Reactive power (kvar), Power factor. Engine readings: Fuel level(%), Battery voltage, R.P.M, Battery charge alternator voltage, Coolant temperature (1), Oil pressure (1). Digital Metering: Total hour counter, Partial hour counter, kw meter, Starts valid and Starts failure counters, Maintenance. Communications (optional): RS232, RS485, Modbus, CCLAN, Software for PC, Analog modem, GSM/GPRS modem, Remote screen, Tele-signal. Other features: Alarms history, External start, Start inhibition, Start under EJP normative, Pre-heating engine control, Genset contactor activation, Fuel transfer control, Engine temperature control, Manual Override, Programmable alarms, Genset start function in test mode, Programmable outputs, Magnetic Pick-up control. Multilingual capability On/Off Switch. Emergency Stop Button. NOTES : All the protections are programmable to carry out Warning Alarm without engine stop or Alarm with Engine Stop (with or without cooling cycle). (A) Alarm with Engine Stop. (W) Warning Alarm without Engine Stop. (1) Sensor installation necessary - 2 -

Standard features Power Panel 3P Main Line Circuit Breaker for overload protection (UL listed)/ CSA 22.2). Main bus / Hardwire connection panel with safety protection. (open thermal magnetic protection and alarm). Battery disconnect switch. Fuel cut-off solenoid and safety switches. Distribution Panel Panel BOX Auxiliary socket box IP67, with individual breaker protection and 2 GFCI DUPLEX 20A 125VGFl for 110v duplex and 2 TWIST-LOCK 50A 2P+N+G. Direct access to auxiliary sockets with suitable protection. Voltage selector switch. Lockable, with 3 positions (3phase 277/480V - 3phase 120/208V - 1phase 120/240V). Electric Equipment Battery charging alternator. Gel type, heavy-duty Starting battery(s) installed and connected to the engine include cables and rack. Ground connection prepared for ground spike (not supplied). Chassis Heavy duty skid base with forklift pockets and drawbars. Extended run time high capacity fuel tank. 110% spill containment for engine oil, coolant and fuel spills. Easy access for chassis cleaning and fast draining of fuel tank. Oversized chassis to protect canopy with skids for dragging embedded and Forklift pockets for easy transport. Vibration isolators between chassis and generator. External fuel tank filling (lockable fuel cap) Chassis ready for mobile kit installation. (see mobile kits options). Enclosure Heavy duty sound attenuated canopy made with high quality 11 gauge steel. Powder coat paint which exceeds 1,000 hour salt spray test. Stainless steel hardware and fasteners. Ultra silent all weather enclosures with Rock- Wool insulation and curved edges with minimum outside fasteners. Reinforced Single eye lifting point. Fuel tank external filling system (lockable filler cap). Emergency stops (double protection for emergency stop; inside on control panel + external on canopy). Door with window to view control panel. Easy access to radiator fill through roof on enclosure. Outlet for power cables. Recesses provision for quick release couplings (external fuel supply). Exhaust Steel residential silencer of -35dBA attenuation, with rain cap. - 3 -

Optional features Engine (optional) Water Jacket Heater Low coolant level sensor. Secondary water separator fuel filter - RACOR type (Decanting filter with water detection kit, alarm signal and sensor contact). Heavy duty, two stage air filter with service indicator. Fuel System (optional) Three way fuel valve with quick disconnect fittings. Automatic fuel transfer pump. Trailers (optional) Road towing trailers to DOT standards. Alternator (optional) Anti-condensation heater. Electric Equipment (optional) Battery isolator. Automatic battery chargers. Distribution PanelDistribution Panel (optional) Camlocks. Electronics (optional) Remote Annunciator Module RAM7 to meet NFPA 110 installation. Digital timer. CANBUS - LAN, converter. CANBUS - USB, converter. Communication modules for tele-control. Multiple remote annunciation options (CAN/USB, GSM, RS232, RS485..). Chassis (optional) Leakage detector sensor. - 4 -

GENSET Model GENSET RATING ENGINE Model ALTERNATOR Model VOLTAGE L-L Ph Hz 150ºC RISE STANDBY RATING 125ºC RISE PRIME RATING kw kva Amps L-L kw kva Amps L-L 4TNV84T PI 144 E 120 1 60 14 18 2x74 13 17 2x69 240 1 60 14 18 74 13 17 69 208 3 60 23 28 79 21 26 72 240 3 60 23 28 68 21 26 62 480 3 60 23 28 34 21 26 31 ENGINE SPECIFICATIONS Manufacturer YANMAR Engine model 4TNV84T BGGEH EPA Certification for: Stage Tier 3-4 Interim Rated RPM 1800 Nominal Power (PRIME) kw - HP 24.2 32.9 Nominal Power (STANDBY) kw - HP 26.8 36.4 Engine type diesel 4-cycle Inyection type DI Aspiration type Turbocharged aspiration Cylinder arrangement 4 - L Bore and stroke (mm) - (84 x 90) Displacement L - 1.995 Cooling system water Governor Type Mechanical Make c Standard c Starting voltage Vcc 12 Air cleaner type Dry light duty Compression ratio 18.9 AMPERAGE 1 Phase 120V 2x69 Amps 1 Phase 240V 69 Amps 3 Phase 208V 72 Amps 3 Phase 240V 62 Amps 3 Phase 480V 31 Amps Main Line Circuit Breaker Rating 90 Amps ALTERNATOR SPECIFICATIONS Manufacturer Stamford Model (480V) PI 144 E Alternator Type 4 poles, rotating field Excitation system Brushless with AVR Exciter Type EBS Leads: quantity, type 12, reconnectable Stator Pitch 2/3 Insulation system Material Class H Temperature rise 150ºC Standby 125ºC Prime Bearing: quantity, type Single bearing sealed Coupling Flexible disc Amortisseur windings Full Automatic Voltage regulator PMG regulator or EBS EBS (Excitation Boost System) Voltage regulation, no load to full load PMG regulator or EBS +/-1% Load acceptance 100% of rated standby current Unbalanced load capability - Subtransient Reactance 480V 12% TIF <50 Line Harmonics 5% Maximum Peak motor starting kva: 30% dip 480V - - 5 -

ELECTRICAL SYSTEM 12V Battery charging alternator: Ground (negative/positive) Negative Volts (DC) V 12 Ampere rating Amp 40 Starter motor rated voltage (DC) V 12 Starter motor rated kw 1.40 Starter motor rated HP 1.90 Battery recommendations Quantity & Min. Amps rating Amp 92 Min. Cold Cranking Amps Amp 440 Battery Voltage (DC) V 12 FUEL SYSTEM Recommended fuel diesel type Fuel supply line. min. ID mm - in M 14X150-0.00 Fuel return line. min. ID mm - in M 14X150-0.00 Fuel pump Type (YPD-MP2) Yanmar made Max. Lift fuel pump m - ft 0.55-0.00 Max. Flow to pump (l/h) - gal/h 30-0 Fuel filter Secondary filter NP Secondary Water Separator Opt. Primary filter Provided Primary Water Separator Provided FUEL CONSUMPTION PRIME STANDBY l/h gal/h l/h gal/h 100% Load l/h - gal/h 7.5 2.0 7.8 2.1 75% Load l/h - gal/h 5.6 1.5 5.8 1.5 50% Load l/h - gal/h 3.9 1.0 4.2 1.1 25% Load l/h - gal/h - - - - Exhaust manifold type Exhaust outlet diameter EXHAUST SYSTEM PRIME Sound Attenuated version mm - In 50-1.97 Max. Exhaust temp. at full load ºC 560 Dry ºF 1040 Exhaust Gas Flow kg/h - Lb/h 181.44 (m3/min) - ft3/min 7.2 Evacuated by the exhaust heat kcal/kwh 216.8 Maximum allowed back pressure COOLING SYSTEM (mm/h2o) - inh2o 1200 (kpa) 0 Engine cooling air flow m3/s - ft3/s 1.0-34.8 Generator cooling air flow m3/min - ft3/min 7.14-252.1 Total cooling air flow (engine + generator + combustion) Sound Attenuated version m3/min - ft3/min 172-0.0 Total cooling capacity l - gal 13.2-3.5 Antifreeze recommended l - gal 6.6-1.7 Oil Filter: quantity. type LUBRICATION SYSTEM 1 x Cartridge paper element Oil pan capacity l - gal 0-0.00 Oil pan capacity with filter l - gal 0-0.00 Oil cooler Recommended Oil Specific oil consumption full load Oil Press Water Cooled PI (CF, CF-4, CI-4); ACEA (E3, E4, E % fuel 0.14 kgf/cm2 VENTILATION REQUIREMENTS Air requirement for combustion at 100% load/rated speed 0.34 m3/h - ft3/h 140.4-4,958 Cooling airflow m3/h - ft3/h 4,121-145,522 Heat rejected to ambient: From engine kw - btu/min 6.78-385.9 From alternator kw - btu/min 0.04-2.28-6 -

Control & Power Panel 1. CM Control Panel. CEM7 Auto-start control panel. On/Off Switch.. Emergency Stop. 2. CP Power Panel. Main Line Circuit Breaker for overload protection (UL listed / CSA22.2). Main bus /hardwire connection panel with safety protection. Fuel cut-off solenoid and safety switches Pictures may include optional equipment and/or accessories. Distribution PanelDistribution Panel 1. Auxiliary socket box IP67 with: Individual breaker protection for sockets 2 GFCI duplex 20A 125VGFI for 110v duplex and 2 TWIST-LOCK 50A 2P+N +G Optional features Distribution PanelDistribution Panel Pictures may include optional equipment and/or accessories. 1. Camlocks - 7 -

Voltage Selector Switch 1. Voltage selector switch 3 positions padlockable (12h / 09h/ 03h). High (Series) Wye 480/277V 3Ph Y. Low (Parallel) Wye 208/120V 3Ph YY. Low (Parallel) Zig Zag 240/120V 1Ph ZZ 2. 7 contact stages, 14 contacts. 3. Switching angle 90º. AC Generator Startor Widing connected for 2Phase +Neutral Parallel Zig-Zag: 120/240 VAC 60Hz AC Generator Startor Widing connected for 3Phase Low Wye: 208/120 VAC 60Hz AC Generator Startor Widing connected for 3Phase Low Wye:480/277 VAC 60Hz - 8 -

CEM7 Auto-start control panel 1. Voltage between each Phase & Neutral. 2. Voltage between Phases. 3. Current (Amps) on each Phase. 4. Frequency. 5. Active, Apparent & Reactive Power. 6. Power Factor. 7. Instant Power (kwh) and Accumulative power (day, month & year). 8. Fuel reserve. 9. Oil pressure, coolant temperature. 10. Battery voltage. 11. Battery charging alternator voltage. 12. Engine Speed. 13. Hours running (total & partial). NOTES : All the protections are programmable to carry out Warning Alarm without engine stop or Alarm with Engine Stop (with or without cooling cycle). (A) Alarm with Engine Stop. (W) Warning Alarm without Engine Stop. (1) Sensor installation necessary. Engine Alarms 1. High coolant temperature (A). 2. Low oil pressure (A). 3. Low coolant level (A). 4. Unexpected shutdown. 5. Low fuel level (W). 6. Stop failure. 7. Battery voltage failure (W). 8. Battery charging alternator failure (W). 9. Overspeed (A). 10. Under-speed (A). 11. Start failure. 12. Emergency stop. Generators Alarms 1. Over-load (A). 2. Unbalanced voltage (A). 3. Over voltage (A). 4. Under voltage (A). 5. Over frequency (A). 6. Under frequency (A). 7. Short-circuit (A). 8. Reverse Power (A). 9. Incorrect phase sequence (A). - 9 -

Enclosure model CR (Length x Width x Height) Overall size (L x W x H) in 88.6 x 43.3 x 53.4 mm 2250 x 1100 x 1357 Dry weight (with std. accessories) Lb Kg 2400 1085 Trailer size (L x W x H) in 158.2 x 77 x 14 mm 4018 x 1955 x 355 Trailer weight Lb Kg 850 386 Fuel Tank Capacity Gal L 26.4 100 Run Time (Hr) 100% 75% 50% 25% 13.4 18 25.7 - NOTE: The drawings are only representative of the overall dimensions. For full detailed drawings please consult your local distributor or contact Himoinsa Power Systems www.hipowersystems.com HIPOWER reserves the right to modify any characteristic without prior notice. The illustrations may include optional equipment and/or accessories. Not contractual images. The technical indications described correspond to the information available at the moment of printing or editing. Distributor: TD 05.2010-10 -