MODEL GBW15-22 Yanmar

Similar documents
MODEL GSW Deutz.

SG101TDA 102,5 (82,0) 108,1 (86,5) 0, ,6 mm Water. Water n disp. 112,0 l/h 91,1 23,0 28,0 217.

MODEL GSW80 Deutz & 110 Perkins.

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

P6000s 230V 50Hz #CONN #DPP

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GMR - 67P 67P 09/05/2016 GMR - 067P

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

P V 50HZ #CONN #DPP

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW555V. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW415V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

S V50HZ #AVR #CONN #DPP

THE COMPLETE PETROL PACKAGE

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW415P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

GE.PK.022/020.SS+0_all

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

EN-GM GENERAC MOBILE PRODUCTS 50Hz POWER GENERATORS GENERAL CATALOGUE

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

TECHNICAL SPECIFICATIONS

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

CGT Stamford UCI 274 E1

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

POWER ENGINEERING KVA 50 HZ rpm

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

Standby Amper VOLTAGE

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

The GRW Series Designed for rental businesses POWER FOR RENT

Standby Amper VOLTAGE

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

Standby Amper VOLTAGE

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

OptionsChartsGenerators_r1_4_EN. Generators Acronyms And Glossary REFERRING TO LINES GMN GMS

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GE.VO.360/325.SS+0_all

PRODUCT CATALOGUE.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

1 / Genset general description

> PRODUCTS RANGE ENGLISH

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

1 / Genset general description

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

Standby Amper VOLTAGE

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

ENGINE brand Yanmar Yanmar Yanmar Perkins Perkins model 3TNV76 3TNV88 4TNV88 403D-15G 404D-22G Cooling system Water Water Water Water Water

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

DEUTZ Engine Documentation Genset Manual. BF4M2012C (D2OC74,9) - 50 Hz 1/5 DEUTZ AG

Transcription:

REF. PC5105_3St.00 MODEL GBW15-22 Yanmar Water cooling system. Industrial muffler. Set easy to be transported with hand pallet truck. Central lifting point. Complete with engine and battery liquids. Oil draining pipe with cap. TECN NICAL FEATURES PRIME POWER PRP EMERGENCY POWER LTP Frequency Power factor MODEL CODE TBA S200TYA Cos φ 13,4 (10,7) Voltage Volt 400 Fuel capacity Litres 51 Autonomy ( 100% load PRP) DIESEL ENGINE z 13,8 (11,0) 20,9 (16,8) 19,0 (15,2) h 14,2 10,4 Dimensions (LxWx) mm 1.600x870x1.000 1.600x870x1.000 Weight kg 399 557 YANMAR 3TNV88-GGE 400 51 4TNV88-GGE Cooling system Water Water Speed rpm 1.0 1.0 Displacement Cyliders and disposition Aspiration Engine power PRP Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) ALTERNATOR Insulation degree protection c.c. 1.642 2.190 n disp. Natural Natural kwm l/h g/kwh Stamford Class alarm Voltmeter. Ammeter. 13,2 PI 044F IP23 Voltage regulation (model) Electronic Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets. Commands shut down Output sockets 3 L Start selector switch with key: OFF - ON* - START. 1 x 400V/16A 3P+N+T CE. 2 x 230V/16A 2P+T CE. PI 144D IP23 Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. 1 x 400V/32A 3P+N+T CE. 1 x Schuko 230V/16A. 4 L 17,7 4,9 Electronic Engine protection: battery charger failure, low oil pressure, high engine temperature. ON*: when selected this position, the system will take some seconds for air perheating by means of a glow plug. The preheating period is lighted by the proper led on the engine protection unit. 3,6 TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Rev.00(Sep2010) Pag. 1 of 2

TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE AUTOMATIC CONTROL PANEL (A AMF) Automatic control panel mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set. AUTOMATIC CONTROL PANEL (AMF) Mains Generating set voltage (3 phases). Generator set current (3 phases). Battery Commands and others Remote starting availability. DC system disconnection switch. alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Output and sockets Engine protection: low oil pressure, high engine temperature. Genset protection: under/over voltage, overload, battery voltage out of limits, under/over frequency, start failure. Genereting set voltage (3 phases). Mains Generating set current (3 phases). Digital instrumentation Battery through AC03 control unit. Power (kva - kw - kvar). Power factor Cos φ. Engine speed r.p.m. 1 x 400V/32A 3P+N+T CE Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, control and protection of the generating set. Commands and others Remote starting availability. Acoustic alarm. RS232 Comuncation port. Mains/Genset alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Power output Genset protection: under/over voltage, overload, under/over battery IV poles - 32A. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) PS: PREEATING SYSTEM. Only available for automatic version. LOAD TRANSFER SWITC PANEL. IV poles 32A. Connections Protections Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. Load transfer switch panel built in a metal cabinet and supplied loose Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains from the genset. failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL GENSET. RS232 communication card for ACP Panel Rev.00(Sep2010) Pag. 2 of 2

REF. PC5105_3Me.00 MODEL GBW15-22 Yanmar Water cooling system. Industrial muffler. Set easy to be transported with hand pallet truck. Central lifting point. Complete with engine and battery liquids. Oil draining pipe with cap. TECN NICAL FEATURES PRIME POWER PRP EMERGENCY POWER LTP Frequency Power factor MODEL CODE S130TYA S200TYA Cos φ 14,0 (11,2) Voltage Volt 400 Fuel capacity Litres 51 Autonomy ( 100% load PRP) z 14,5 (11,6) 21,7 (17,3) 19,7 (15,8) h 14,2 10,4 Dimensions (LxWx) mm 1.600x870x1.000 1.600x870x1.000 Weight kg 443 469 DIESEL ENGINE YANMAR 3TNV88-GGE 4TNV88-GGE Cooling system Water Water Speed Displacement Cyliders and disposition Aspiration Engine power PRP Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) ALTERNATOR Insulation rpm 1.0 1.0 c.c. 1.642 2.190 n disp. Natural Natural kwm g/kwh MeccAlte Class Commands alarm Voltmeter. Ammeter. 13,2 ECP 3 2L degree protection IP23 l/h Voltage regulation (model) Electronic Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets. shut down Output sockets Start selector switch with key: OFF - ON* - START. 1 x 400V/16A 3P+N+T CE. 2 x 230V/16A 2P+T CE. 400 51 ECO 28 1L IP23 Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. 1 x 400V/32A 3P+N+T CE. 1 x Schuko 230V/16A. 4 L 4,9 Electronic Engine protection: battery charger failure, low oil pressure, high engine temperature. ON*: when selected this position, the system will take some seconds for air perheating by means of a glow plug. The preheating period is lighted by the proper led on the engine protection unit. 3 L 3,6 17,7 TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Rev.00(Sep2010) Pag. 1 of 2

TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE AUTOMATIC CONTROL PANEL (A AMF) Automatic control panel mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set. Output and sockets AUTOMATIC CONTROL PANEL (AMF) Mains Generating set voltage (3 phases). Generator set current (1 phase). Battery Commands and others Remote starting availability. DC system disconnection switch. alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Engine protection: low oil pressure, high engine temperature. Genset protection: under/over voltage, overload, battery voltage out of limits, under/over frequency, start failure. Genereting set voltage (3 phases). Mains Generating set current (3 phases). Digital instrumentation Battery through AC03 control unit. Power (kva - kw - kvar). Power factor Cos φ. Engine speed r.p.m. 1 x 400V/32A 3P+N+T CE Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, control and protection of the generating set. Commands and others Remote starting availability. Acoustic alarm. RS232 Comuncation port. Mains/Genset alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Power output Genset protection: under/over voltage, overload, under/over battery IV poles - 32A. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) PS: PREEATING SYSTEM. Only available for automatic version. LOAD TRANSFER SWITC PANEL. IV poles 32A. Connections Protections Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. Load transfer switch panel built in a metal cabinet and supplied loose Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains from the genset. failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL GENSET. RS232 communication card for ACP Panel Rev.00(Sep2010) Pag. 2 of 2

REF. PC5105_3Li.00 MODEL GBW15-22 Yanmar Water cooling system. Industrial muffler. Set easy to be transported with hand pallet truck. Central lifting point. Complete with engine and battery liquids. Oil draining pipe with cap. TECN NICAL FEATURES PRIME POWER PRP EMERGENCY POWER LTP Voltage Volt 400 Frequency Power factor Autonomy ( 100% load PRP) Dimensions (LxWx) mm 1.600x870x1.000 1.600x870x1.000 Weight kg 443 469 DIESEL ENGINE Speed rpm 1.0 1.0 Displacement MODEL CODE S130TYA S200TYA z Cos φ Fuel capacity Litres 51 YANMAR 3TNV88-GGE 4TNV88-GGE Cooling system Water Water Cyliders and disposition Aspiration Engine power PRP Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) ALTERNATOR Insulation Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets. 13,0 (10,4) 18,6 (14,9) 14,3 (11,4) 20,5 (16,4) h 14,2 10,4 c.c. 1.642 2.190 n disp. degree protection IP21 l/h Voltage regulation (model) Compound Commands shut down Output sockets 3,6 400 51 ON*: when selected this position, the system will take some seconds for air perheating by means of a glow plug. The preheating period is lighted by the proper led on the engine protection unit. 3 L Natural Natural kwm g/kwh Linz Class alarm Voltmeter. Ammeter. 13,2 E1S13M/4/13 Start selector switch with key: OFF - ON* - START. 17,7 Engine protection: battery charger failure, low oil pressure, high engine temperature. 1 x 400V/32A 3P+N+T CE. 1 x 400V/16A 3P+N+T CE. 2 x 230V/16A 2P+T CE. 1 x Schuko 230V/16A. 4 L 4,9 E1S13M/4/20 IP21 Compound Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Rev.00(Sep2010) Pag. 1 of 2

TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE AUTOMATIC CONTROL PANEL (A AMF) Automatic control panel mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set. Commands and others alarm Output and sockets AUTOMATIC CONTROL PANEL (AMF) Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, control and protection of the generating set. Mains Generating set voltage (3 phases). Generator set current (1 phase). Battery Remote starting availability. DC system disconnection switch. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Engine protection: low oil pressure, high engine temperature. Genset protection: under/over voltage, overload, battery voltage out of limits, under/over frequency, start failure. Genereting set voltage (3 phases). Mains Generating set current (3 phases). Digital instrumentation Battery through AC03 control unit. Power (kva - kw - kvar). Power factor Cos φ. Engine speed r.p.m. 1 x 400V/32A 3P+N+T CE Commands and others Remote starting availability. Acoustic alarm. RS232 Comuncation port. Mains/Genset IV poles - 32A. alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Power output Genset protection: under/over voltage, overload, under/over battery Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) PS: PREEATING SYSTEM. Only available for automatic version. LOAD TRANSFER SWITC PANEL. IV poles 32A. Connections Protections Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. Load transfer switch panel built in a metal cabinet and supplied loose Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains from the genset. failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL GENSET. RS232 communication card for ACP Panel Rev.00(Sep2010) Pag. 2 of 2