REF. PC5105_3St.00 MODEL GBW15-22 Yanmar Water cooling system. Industrial muffler. Set easy to be transported with hand pallet truck. Central lifting point. Complete with engine and battery liquids. Oil draining pipe with cap. TECN NICAL FEATURES PRIME POWER PRP EMERGENCY POWER LTP Frequency Power factor MODEL CODE TBA S200TYA Cos φ 13,4 (10,7) Voltage Volt 400 Fuel capacity Litres 51 Autonomy ( 100% load PRP) DIESEL ENGINE z 13,8 (11,0) 20,9 (16,8) 19,0 (15,2) h 14,2 10,4 Dimensions (LxWx) mm 1.600x870x1.000 1.600x870x1.000 Weight kg 399 557 YANMAR 3TNV88-GGE 400 51 4TNV88-GGE Cooling system Water Water Speed rpm 1.0 1.0 Displacement Cyliders and disposition Aspiration Engine power PRP Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) ALTERNATOR Insulation degree protection c.c. 1.642 2.190 n disp. Natural Natural kwm l/h g/kwh Stamford Class alarm Voltmeter. Ammeter. 13,2 PI 044F IP23 Voltage regulation (model) Electronic Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets. Commands shut down Output sockets 3 L Start selector switch with key: OFF - ON* - START. 1 x 400V/16A 3P+N+T CE. 2 x 230V/16A 2P+T CE. PI 144D IP23 Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. 1 x 400V/32A 3P+N+T CE. 1 x Schuko 230V/16A. 4 L 17,7 4,9 Electronic Engine protection: battery charger failure, low oil pressure, high engine temperature. ON*: when selected this position, the system will take some seconds for air perheating by means of a glow plug. The preheating period is lighted by the proper led on the engine protection unit. 3,6 TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Rev.00(Sep2010) Pag. 1 of 2
TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE AUTOMATIC CONTROL PANEL (A AMF) Automatic control panel mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set. AUTOMATIC CONTROL PANEL (AMF) Mains Generating set voltage (3 phases). Generator set current (3 phases). Battery Commands and others Remote starting availability. DC system disconnection switch. alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Output and sockets Engine protection: low oil pressure, high engine temperature. Genset protection: under/over voltage, overload, battery voltage out of limits, under/over frequency, start failure. Genereting set voltage (3 phases). Mains Generating set current (3 phases). Digital instrumentation Battery through AC03 control unit. Power (kva - kw - kvar). Power factor Cos φ. Engine speed r.p.m. 1 x 400V/32A 3P+N+T CE Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, control and protection of the generating set. Commands and others Remote starting availability. Acoustic alarm. RS232 Comuncation port. Mains/Genset alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Power output Genset protection: under/over voltage, overload, under/over battery IV poles - 32A. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) PS: PREEATING SYSTEM. Only available for automatic version. LOAD TRANSFER SWITC PANEL. IV poles 32A. Connections Protections Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. Load transfer switch panel built in a metal cabinet and supplied loose Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains from the genset. failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL GENSET. RS232 communication card for ACP Panel Rev.00(Sep2010) Pag. 2 of 2
REF. PC5105_3Me.00 MODEL GBW15-22 Yanmar Water cooling system. Industrial muffler. Set easy to be transported with hand pallet truck. Central lifting point. Complete with engine and battery liquids. Oil draining pipe with cap. TECN NICAL FEATURES PRIME POWER PRP EMERGENCY POWER LTP Frequency Power factor MODEL CODE S130TYA S200TYA Cos φ 14,0 (11,2) Voltage Volt 400 Fuel capacity Litres 51 Autonomy ( 100% load PRP) z 14,5 (11,6) 21,7 (17,3) 19,7 (15,8) h 14,2 10,4 Dimensions (LxWx) mm 1.600x870x1.000 1.600x870x1.000 Weight kg 443 469 DIESEL ENGINE YANMAR 3TNV88-GGE 4TNV88-GGE Cooling system Water Water Speed Displacement Cyliders and disposition Aspiration Engine power PRP Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) ALTERNATOR Insulation rpm 1.0 1.0 c.c. 1.642 2.190 n disp. Natural Natural kwm g/kwh MeccAlte Class Commands alarm Voltmeter. Ammeter. 13,2 ECP 3 2L degree protection IP23 l/h Voltage regulation (model) Electronic Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets. shut down Output sockets Start selector switch with key: OFF - ON* - START. 1 x 400V/16A 3P+N+T CE. 2 x 230V/16A 2P+T CE. 400 51 ECO 28 1L IP23 Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. 1 x 400V/32A 3P+N+T CE. 1 x Schuko 230V/16A. 4 L 4,9 Electronic Engine protection: battery charger failure, low oil pressure, high engine temperature. ON*: when selected this position, the system will take some seconds for air perheating by means of a glow plug. The preheating period is lighted by the proper led on the engine protection unit. 3 L 3,6 17,7 TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Rev.00(Sep2010) Pag. 1 of 2
TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE AUTOMATIC CONTROL PANEL (A AMF) Automatic control panel mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set. Output and sockets AUTOMATIC CONTROL PANEL (AMF) Mains Generating set voltage (3 phases). Generator set current (1 phase). Battery Commands and others Remote starting availability. DC system disconnection switch. alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Engine protection: low oil pressure, high engine temperature. Genset protection: under/over voltage, overload, battery voltage out of limits, under/over frequency, start failure. Genereting set voltage (3 phases). Mains Generating set current (3 phases). Digital instrumentation Battery through AC03 control unit. Power (kva - kw - kvar). Power factor Cos φ. Engine speed r.p.m. 1 x 400V/32A 3P+N+T CE Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, control and protection of the generating set. Commands and others Remote starting availability. Acoustic alarm. RS232 Comuncation port. Mains/Genset alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Power output Genset protection: under/over voltage, overload, under/over battery IV poles - 32A. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) PS: PREEATING SYSTEM. Only available for automatic version. LOAD TRANSFER SWITC PANEL. IV poles 32A. Connections Protections Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. Load transfer switch panel built in a metal cabinet and supplied loose Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains from the genset. failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL GENSET. RS232 communication card for ACP Panel Rev.00(Sep2010) Pag. 2 of 2
REF. PC5105_3Li.00 MODEL GBW15-22 Yanmar Water cooling system. Industrial muffler. Set easy to be transported with hand pallet truck. Central lifting point. Complete with engine and battery liquids. Oil draining pipe with cap. TECN NICAL FEATURES PRIME POWER PRP EMERGENCY POWER LTP Voltage Volt 400 Frequency Power factor Autonomy ( 100% load PRP) Dimensions (LxWx) mm 1.600x870x1.000 1.600x870x1.000 Weight kg 443 469 DIESEL ENGINE Speed rpm 1.0 1.0 Displacement MODEL CODE S130TYA S200TYA z Cos φ Fuel capacity Litres 51 YANMAR 3TNV88-GGE 4TNV88-GGE Cooling system Water Water Cyliders and disposition Aspiration Engine power PRP Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) ALTERNATOR Insulation Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets. 13,0 (10,4) 18,6 (14,9) 14,3 (11,4) 20,5 (16,4) h 14,2 10,4 c.c. 1.642 2.190 n disp. degree protection IP21 l/h Voltage regulation (model) Compound Commands shut down Output sockets 3,6 400 51 ON*: when selected this position, the system will take some seconds for air perheating by means of a glow plug. The preheating period is lighted by the proper led on the engine protection unit. 3 L Natural Natural kwm g/kwh Linz Class alarm Voltmeter. Ammeter. 13,2 E1S13M/4/13 Start selector switch with key: OFF - ON* - START. 17,7 Engine protection: battery charger failure, low oil pressure, high engine temperature. 1 x 400V/32A 3P+N+T CE. 1 x 400V/16A 3P+N+T CE. 2 x 230V/16A 2P+T CE. 1 x Schuko 230V/16A. 4 L 4,9 E1S13M/4/20 IP21 Compound Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Rev.00(Sep2010) Pag. 1 of 2
TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE AUTOMATIC CONTROL PANEL (A AMF) Automatic control panel mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set. Commands and others alarm Output and sockets AUTOMATIC CONTROL PANEL (AMF) Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, control and protection of the generating set. Mains Generating set voltage (3 phases). Generator set current (1 phase). Battery Remote starting availability. DC system disconnection switch. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Engine protection: low oil pressure, high engine temperature. Genset protection: under/over voltage, overload, battery voltage out of limits, under/over frequency, start failure. Genereting set voltage (3 phases). Mains Generating set current (3 phases). Digital instrumentation Battery through AC03 control unit. Power (kva - kw - kvar). Power factor Cos φ. Engine speed r.p.m. 1 x 400V/32A 3P+N+T CE Commands and others Remote starting availability. Acoustic alarm. RS232 Comuncation port. Mains/Genset IV poles - 32A. alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Power output Genset protection: under/over voltage, overload, under/over battery Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) PS: PREEATING SYSTEM. Only available for automatic version. LOAD TRANSFER SWITC PANEL. IV poles 32A. Connections Protections Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. Load transfer switch panel built in a metal cabinet and supplied loose Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains from the genset. failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL GENSET. RS232 communication card for ACP Panel Rev.00(Sep2010) Pag. 2 of 2