Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

Similar documents

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Benefits, typical uses

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

NXAirS Withdrawable Medium-Voltage Switchgear up to 24kV Air-Insulated

Air-Insulated Medium-Voltage Switchgear NXAIR, up to 24 kv

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

Catalog HA Edition Medium-Voltage Switchgear. siemens.com/nxair

Fixed-Mounted Circuit-Breaker Switchgear up to 36 kv, SF 6 -Insulated

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS up to 40.5 kv, Gas-Insulated

Power Transmission and Distribution. NXPLUS C double busbar. The economical solution when replacing old systems

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Types. Fixed-mounted circuitbreaker. NXPLUS C is a factoryassembled,

NXPLUS C Single busbar. Maintenance-free for lifetime

Vacuum Circuit Breaker

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

VB1-D Generator Circuit-Breaker Switchgear

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

HB1 and VB1 Generator Circuit-Breaker Switchgear. Medium-Voltage Switchgear. siemens.com/generatorswitchgear. Catalog HB1 and VB1 Edition 2017

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

8DJ. Maintenance-free for lifetime

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Features. 2 Siemens HA Page. 8DJ10 switchgear is a factoryassembled,

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

HIGS Highly Integrated Generator Circuit-Breaker Switchgear

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

UniGear. Technical Guide

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35.

Medium-Voltage Switchgear OPERATING INSTRUCTIONS

Switchgear Type 8DJH 36 for Secondary

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

the safe, reliable, and efficient choice for MV switchgear

with Vacuum Circuit Breaker HAF

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Metal Clad Switchgears

Gas Insulated Metal-clad Switchgear, HMGS!

Gas-insulated medium-voltage switchgear. For the metal industry. Answers for energy.

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

ZX2 Gas-insulated medium voltage switchgear

voltage switchgear ZX ABB ZX Family 1

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

ZX-Family Gas-insulated medium voltage switchgear

3TM Vacuum Contactors

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

CPG.0 Single busbar gas-insulated cubicles

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

Switchgear Type 8DH10 up to 24 kv, Gas-Insulated, Extendable

MESG 12 / 17.5 / 24 / 36 KV

PIX-H Metal-clad switchgear up to 17.5kV

Gas-insulated switchgear up to 420 kv, 63 ka, 5000 A Type 8DQ1. siemens.com/energy. Answers for energy.

ZX2.2 Gas-insulated medium voltage switchgear

HB3 Generator Circuit-Breaker Switchgear

HB3-80 Generator Circuit-Breaker Switchgear. Medium-Voltage Switchgear. Totally Integrated Power HB3-80. Catalog HB3-80.

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

Air-insulated switchgear UniGear type ZS1

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Gas-insulated medium-voltage switchgear. For marine and offshore applications. Answers for energy.

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Cost-Efficient Solution for Power Distribution. Gas-Insulated Medium-Voltage Switchgear: Safe, Compact and Reliable

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

Metal Clad Air Insulated Switchgear

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

with Vacuum Circuit Breaker HAF

Reliable Solution for Power Distribution. Air-Insulated Medium-Voltage Switchgear: Cost-Efficient, Sustainable and Safe

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

PT Guna Era Manufaktura. Catalogue GAE TPS \ Medium Voltage Switchgear 12kV - 24kV \ M GAE TPS. Medium Voltage Switchgear 12kV - 24kV

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

AF series contactors (9 2650)

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears

Totally Integrated Power. A reliable all-rounder. Gas-insulated medium-voltage switchgear 8DJH 36.

Transcription:

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear Catalog HA 26.11 2008 Answers f energy.

R-HA26-010c.eps Contents Application Benefits, typical uses Application Page Benefits 2 Typical uses 2 and 3 Technical Data Ratings 4 Classification, dimensions, room planning 5 Product Range Panels 6 and 7 Design Panel design 8 Compartments, interlocks, operation 9 Benefits and features 10 Standards Standards, specifications, guidelines 11 and 12 Comments 13 Benefits (see also page 10 f details) Saves lives Peace of mind Increases productivity Saves money The circuit-breaker switchgear type SIMOPRIME is a facty-assembled, type-tested switchgear f indo installation accding to IEC 62271-200 and VDE 0671-200. Loss of service continuity categy: LSC 2B Partition class: PM Internal arc classification: IAC A FLR, I sc w, arc duration: 10.1s Supersedes: Catalog HA 26.11 2007 SIMOPRIME panel Maximum ratings 17.5 kv / / 3600 A Typical uses The SIMOPRIME circuit-breaker switchgear can be used in transfmer and switching substations, e.g.: The products and systems described in this catalog are manufactured and sold accding to a certified quality and environmental management system (acc. to ISO 9001 and ISO 14001). (DQS Certificate Reg. No. DQS 003473 QM UM). The certificate is accepted in all IQNet countries. Application: Power supply system Power supply companies Application: Industry Power stations Cement industry Automobile industry Iron and steel wks Rolling mills Mining industry Textile, paper and food industries Chemical industry Petroleum industry Pipeline installations Offshe installations Electrochemical plants Petrochemical plants Shipbuilding industry Diesel power plants Emergency power supply installations Lignite open-cast mines Traction power supplies 2 Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008

R-HA25-327 eps R-HA25-308 eps R-HA25-326 eps Application Typical uses Application Industry R-HA26-012.tif Application Public power supply system SIMOPRIME switchgear Application Industry Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008 3

Technical Data Ratings Electrical data (maximum values) of SIMOPRIME Ratings Rated values (max.) Ratings Rated values (max.) Switchgear up to 7.2 kv Rated voltage 7.2 kv Rated frequency 50/60 Hz Rated sht-duration power-frequency withstand voltage 20 kv 1) Rated lightning impulse withstand voltage 60 kv Rated sht-time withstand current, 3 s Rated peak withstand current at 50/60 Hz 100/104 ka Rated sht-circuit breaking current Rated sht-circuit making current at 50/60 Hz 100/104 ka Rated nmal current of busbar 3600 A Rated nmal current of feeders with circuit-breaker with vacuum contact 3600 A 400 A 2) Switchgear 12 kv Rated voltage 12 kv Rated frequency 50/60 Hz Rated sht-duration power-frequency withstand voltage 28 kv 1) Rated lightning impulse withstand voltage 75 kv 3) Rated sht-time withstand current, 3 s Rated peak withstand current at 50/60 Hz 100/104 ka Rated sht-circuit breaking current Rated sht-circuit making current at 50/60 Hz 100/104 ka Rated nmal current of busbar 3600 A Rated nmal current of feeders with circuit-breaker with vacuum contact 3600 A 400 A 2) Switchgear 15 kv Rated voltage 15 kv Rated frequency 50/60 Hz Rated sht-duration power-frequency withstand voltage 35 kv Rated lightning impulse withstand voltage 95 kv Rated sht-time withstand current, 3 s Rated peak withstand current at 50/60 Hz 100/104 ka Rated sht-circuit breaking current Rated sht-circuit making current at 50/60 Hz 100/104 ka Rated nmal current of busbar 3600 A Rated nmal current of feeders with circuit-breaker 3600 A Switchgear 17.5 kv Rated voltage 17.5 kv Rated frequency 50/60 Hz Rated sht-duration power-frequency withstand voltage 38 kv Rated lightning impulse withstand voltage 95 kv Rated sht-time withstand current, 3 s Rated peak withstand current at 50/60 Hz 100/104 ka Rated sht-circuit breaking current Rated sht-circuit making current at 50/60 Hz 100/104 ka Rated nmal current of busbar 3600 A Rated nmal current of feeders with circuit-breaker 3600 A 1) Option: Higher values acc. to GOST standards 2) Depending on the rated current of the HV HRC fuses installed 3) 60 kv f vacuum contact 4 Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008

Technical Data Classification, dimensions, room planning Classification of the SIMOPRIME switchgear accding to IEC 62271-200 Internal arc classification Classification Accessibility Front Rear Lateral Test current Arc duration ka s IAC Type A Type A Type A 25/31.5/40 0.1/1.0 Construction and design Partition class Loss of service continuity categy Compartment accessibility (standard) Busbar compartment Switching-device compartment Low-voltage compartment Connection compartment Front connection Rear connection PM (metallic partition) LSC2B (metal-clad) Tool-based Interlock-controlled Tool-based Interlock-controlled and tool-based Tool-based Dimensions Room planning (room height W 2 mm) HA26-2024d eps H1 H2 HA26-2025a eps Front connection B 40 ³100 Front B 40 ³100 H3 1500 1) T ³100 B T Single-row arrangement (plan view) F dimensions B (width) and T (depth) refer to table on this page 1) Control aisle widths w 31.5 ka version: W 1500 mm 3600 A versions: W 1700 mm F panel replacement: W 2000 mm Dimensions All panel types in mm Width B up to Circuit-breaker panel w 1250 A 2500 A, 3150 A, 3600 A 31.5 ka 600 Contact panel 435 2) /600 435 2) Disconnecting panel w 1250 A 2500 A, 3150 A, 3600 A Bus sectionalizer/circuit-breaker panel w 1250 A 2500 A, 3150 A, 3600 A Bus sectionalizer/bus riser panel w 2500 A 3150 A, 3600 A 600 600 600 Metering panel 600 Height H1 With standard low-voltage compartment and IAC 0.1 s 2253 2253 H2 With standard low-voltage compartment and IAC 1.0 s 2425 2460 H3 1780 1780 Depth T Standard 1860 1860 HA26-2026a eps Rear connection B 40 ³500 Front 40 ³500 Single-row arrangement (plan view) F dimensions B (width) and T (depth) refer to table on this page 1) Control aisle widths w 31.5 ka version: W 1500 mm 3600 A versions: W 1700 mm F panel replacement: W 2000 mm B 1500 1) T ³ 2) Can be dered as of the year 2009 Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008 5

Product Range Panels Circuit-breaker panel Disconnecting panel Vacuum cantact panel HA26-2016a eps HA26-2019b eps HA26-2017a eps Components Current transfmer Vacuum contact with HV HRC fuses Vacuum circuit-breaker 1) The details refer to conventional single-ce sealing ends. Voltage transfmer without primary fuses Vacuum contact with control transfmer and HV HRC fuses Disconnect Current transfmer in run of busbar Make-proof earthing switch HV HRC fuse Voltage transfmer with primary fuses Cable sealing ends 1) max. 4 x 500 mm 2 per phase HA26-2020d eps Capacitive voltage detecting system Bar connection 6 Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008

Product Range Panels Bus sectionalizer (mirr-image installation also possible) Metering panel HA26-2021 eps Circuitbreaker panel Bus riser panel HA26-2022a eps Components Current transfmer Withdrawable voltage transfmer with primary fuses Make-proof earthing switch Voltage transfmer without primary fuses Capacitive voltage detecting system Vacuum circuit-breaker HA26-2023a eps Current transfmer in run of busbar Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008 7

Design Panel design Legend f panel design: 1 Do of low-voltage compartment 2 Opening f locking unlocking the low-voltage compartment do 3 Option: Capacitive voltage detecting system f feeder and busbar 4 High-voltage do 5 Inspection window f checking the switchingdevice truck 6 Opening f locking unlocking the high-voltage do 7 Opening f mechanical charging of circuit-breaker closing spring 8 Openings f manual operation (ON/OFF) of the circuit-breaker 9 Inspection window f reading the indicats 10 Do handle 11 Openings f switchingdevice truck operation 12 Opening f earthing-switch operation 13 Pressure relief duct 1 2 3 4 5 6 7 8 9 10 11 12 Basic panel design (example) HA26-2115 eps 13 14 15 16 17 18 19 20 21 Circuit-breaker panel 12 kv, 1250 A, B C A E D HA26-2116a eps 22 23 24 14 Busbars 15 Bushings 16 Post insulats 17 Block-type current transfmer 18 Option: Make-proof earthing switch 19 Cable sealing ends 20 Option: Voltage transfmer 21 Earthing busbar 22 Low-voltage plug connect 23 Vacuum interrupters 24 Switching-device truck A Switching-device compartment B Busbar compartment C Connection compartment D Vacuum circuit-breaker truck E Low-voltage compartment 8 Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008

Design Compartments, interlocks, operation Switching-device compartment All switching operations with high-voltage do closed Pressure relief upwards Panel powder-coated with epoxy resin Shutter operating mechanisms separately f Busbar compartment Connection compartment Metallic, earthed shutters and partitions ensure partition class PM High-voltage do pressureresistant in the event of internal arcs in the panel Metallic ducts on the side f laying control cables Interlocking between high-voltage do and circuit-breaker truck ensures interlock-based access Option: Test sockets f capacitive voltage detecting system Switching-device compartment to accommodate components f implementing various panel versions with Vacuum circuit-breaker with without voltage transfmers on the truck Disconnect truck Vacuum-contact truck Metering truck Busbar compartment Pressure relief upwards and through rear pressure relief duct Option: Busbar transverse partition between panels Busbars made of flat copper, bolted from panel to panel F rated nmal currents up to 3600 A Option: Insulated busbars Bolted rear and top covers provide tool-based access Option: Coupling electrode f capacitive voltage detecting system Options: Possibility of installing the following components Voltage transfmers Busbar earthing switch Current transfmers in the run of busbars Connection compartment Pressure relief upwards through rear pressure relief duct Suitable f connection of Single-ce XLPE cables up to max. 6 x 500 mm 2 per phase Three-ce XLPE cables up to max. 3 x 300 mm 2 per panel Bars made of flat copper with bushings in a flo cover fully-insulated bars including flo cover Shutters to be opened separately to permit cable testing Earthing busbar Connection from front rear Option: Pressure-resistant flo cover Use of ring-ce block-type current transfmers Bolted rear covers of the connection compartment provide tool-based access f panels with connection from rear Interlocked high-voltage do and bolted partitions between connection compartment and switching-device compartment provide interlock-based and tool-based access f panels with connection from front Components at the panel connection (option) Couplingelectrodef capacitive voltage detecting system Voltage transfmers Cast-resin insulated Max.3x1-pole Fixed-mounted, without primary fuses Make-proof earthingswitches With manual operating mechanism In addition to standard interlocking of earthing switch/ circuit-breaker truck, optionally lockable with electromagnetic interlock Surge arresters limiters Surge arresters f protecting the switchgear against external overvoltages Surge limiters f protecting consumers against switching overvoltages Interlocks Interlocking conditions are satisfied accding to IEC 62271-200 / VDE 0671-200 Earthing switch can only be operated with circuit-breaker truck in test position Circuit-breaker truck can only be moved with circuit-breaker OPEN and earthing switch OPEN Mechanical coding on the circuit-breaker truck prevents insertion of similar circuitbreaker trucks f lower rated nmal currents into panels with higher rated nmal currents Interlocking of high-voltage do against circuit-breaker truck The high-voltage do can only be opened when the circuit-breaker truck is in test position Option: Electromagnetic interlocks Low-voltage compartment F accommodation of all protection, control, measuring and metering equipment Partitioned safe-to-touch from the high-voltage part Low-voltage compartment can be removed, bus wires and control cables are plugged in Option: Partition between panels Low-voltage cables Control cables of the panel are flexible and have metallic covers Connection of switchingdevice truck and panel wiring to low-voltage compartment via 64-pole coded plug connects Bus wires are pluggable from panel to panel Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008 9

Design Benefits and features Benefits Saves lives Features All switching operations including emergency manual operations with high-voltage do closed Interlocking between high-voltage do and switching devices Rack-in, rack-out operations of the circuit-breaker truck with high-voltage do closed Metallic, earthed shutters and partitions, partition class: PM (metallic partition) Internal arc tested design up to, 1 s, accding to IEC 62271-200, VDE 0671-200 Use of vacuum circuit-breakers Peace of mind Facty-assembled, type-tested switchgear accding to IEC 62271-200 Type testing of the circuit-breaker inside the panel Use of standard, wld-wide available components Use of maintenance-free vacuum circuit-breakers Quality management accding to DIN EN ISO 9001 Design based on global best practice sharing and experience Me than 300,000 air-insulated switchgear panels from Siemens in operation wld-wide Increases productivity Saves money Use of metallic, earthed shutters and partitions between the compartments ensures highest loss of service continuity of the switchgear (LSC2B accding to IEC 62271-200) during maintenance Use of maintenance-free vacuum circuit-breakers Use of maintenance-free vacuum circuit-breakers 10 Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008

Standards Standards, specifications, guidelines Standards The switchgear complies with the relevant standards and specifications applicable at thetimeoftypetests. In accdance with the harmonization agreement reached by the EU countries, their national specifications confm to the IEC standard. Overview of standards (March 2008) IEC standard VDE standard EN standard Switchgear SIMOPRIME IEC 62271-1 VDE 0671-1 EN 62271-1 IEC 62271-200 VDE 0671-200 EN 62271-200 Devices Circuit-breaker IEC 62271-100 VDE 0671-100 EN 62271-100 Vacuum contact IEC 60470 VDE 0670-501 EN 60470 Disconnect and IEC 62271-102 VDE 0671-102 EN 62271-102 earthing switch HV HRC fuses IEC 60282 VDE 0670-4 EN 60282 Voltage detecting IEC 61243-5 VDE 0682-415 EN 61243-5 systems Degree of IEC 60529 VDE 0470-1 EN 60529 protection Insulation IEC 60071 VDE 0111 EN 60071 Instrument transfmers Current transfmer IEC 60044-1 VDE 0414-1 EN 60044-1 Voltage transfmer IEC 60044-2 VDE 0414-2 EN 60044-2 Installation IEC 61936-1 VDE 0101 Type of service location The switchgear can be used f indo installation in accdance with IEC 61936 (Power installations exceeding 1 kv AC) and VDE 0101 Outside lockable electrical service locations at places which are not accessible to the public. Enclosures of switchgear can only be removed with tools. Inside lockable electrical service locations. A lockable electrical service location is a place outdos indos that is reserved exclusively f housing electrical equipment and which is kept under lock and key. Access is restricted to authized personnel and persons who have been properly instructed in electrical engineering. Untrained unskilled persons may only enter under the supervision of authized personnel properly instructed persons. Table Dielectric strength Rated voltage (rms value) kv 7.2 12 15 17.5 Rated sht-duration power-frequency withstand voltage (rms value) Across isolating distances kv 23 32 39 45 Between phases and to earth kv 20 28 35 38 Rated lightning impulse withstand voltage (peak value) Across isolating distances kv 70 85 105 110 Between phases and to earth kv 60 75 95 95 Altitude crection fact Ka F site altitudes above 1000 m, the altitude crection fact K a is recommended, depending on the actual site altitude above sea level. Altitude crection fact K a 1.50 A 1.40 1.30 1.20 1.10 1.00 1000 m = 1 1500 2000 2500 3000 3500 4000 Site altitude in m above sea level Rated sht-dur. power-freq. withstand volt. to be selected f site altitudes > 1000 m W Rated sht-duration power-frequency withstand voltage up to w 1000 m K a Rated lightning impulse withstand volt. to be selected f site altitudes > 1000 m W Rated lightning impulse withstand voltage up to w 1000 m K a Example: 1 m site altitude above sea level 12 kv switchgear rated voltage 75 kv rated lightning impulse withstand voltage Rated lightning impulse withstand voltage to be selected 75 kv 1.10 = 82.5 kv Result: HA40-2037a en eps Accding to the above table, a switchgear f a rated voltage of 17.5 kv is to be selected. Dielectric strength The dielectric strength is verified by testing the switchgear with rated values of shtduration power-frequency withstand voltage and lightning impulse withstand voltage accding to IEC 62271-1 / VDE 0671-1 (see table Dielectric strength ). The rated values are referred to sea level and to nmal atmospheric conditions (1013 hpa, 20 C, 11 g/m 3 humidity in accdance with IEC 60071 / VDE 0111). The dielectric strength decreases with increasing altitude. F site altitudes above 1000 m (above sea level) the standards do not provide any guidelines f the insulation rating. Instead, special arrangements apply to these altitudes. Site altitude As the altitude increases, the dielectric strength in air decreases due to the decreasing air density. This reduction is permitted up to a site altitude of 1000 m accding to IEC and VDE. F site altitudes above 1000 m, a higher insulation level must be selected. It results from the multiplication of the rated insulation level f 0 to 1000 m with the altitude crection fact K a. Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008 11

Standards Standards, specifications, guidelines Terms Make-proof earthing switches are earthing switches with sht-circuit making capacity accding to IEC 62271-102 and VDE 0671-102 / EN 62271-102 Internal arc classification Protection of operating personnel by means of tests f verifying the internal arc classification Internal arcing tests must be perfmed in accdance with IEC 62271-200 / VDE 0671-200 The switchgear complies with criteria 1 to 5 specified in the mentioned standards f the basic version up to. Definitions of the criteria: Criterion 1 Crectly secured dos and covers do not open. Limited defmations are accepted. Criterion 2 No fragmentation of the enclosure. Projection of small parts up to an individual mass of 60 g are accepted. Criterion 3 Arcing does not cause holes intheaccessiblesidesupto aheightof2m. Criterion 4 Hizontal and vertical indicats do no ignite due totheeffectofhotgases. Criterion 5 The enclosure remains connected to its earthing point. Current-carrying capacity Accding to IEC 62271-1 / VDE 0671-1 and IEC 62271-200 / VDE 0671-200 currentcarrying capacities refer to the following ambient air temperatures: Maximumof 24-hourmean +35 C Maximum +40 C The current-carrying capacity of the panels and busbars depends on the ambient air temperature outside the enclosure. To attain the maximum rated nmal currents, the panels are provided with natural fced ventilation. Climate and environmental influences The switchgear may be used, subject to possible additional measures, under the following environmental influences and climate classes: Environmental influences Natural feign materials Chemically active pollutants Small animals Climate classes 3K3 3K5 The climate classes are classified accding to IEC 60721-3-3. Protection against solid feign bodies, electric shock and ingress of water SIMOPRIME switchgear fulfills acc. to the standards IEC 62271-200 IEC 60529 VDE 0470-1 VDE 0671-200 the following degrees of protection: Enclosure: IP 4X, IP 5X (protection against solid feign bodies) IP X1, IP X2 (protection against ingress of water) Compartments: IP 2X (protection against solid feign bodies) Higher degree of protection f enclosure on request. 12 Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008

Comments Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008 13

Responsible f Technical contents: Deger Š Tasdelen Siemens AG, E D MV 1 PPM, Erlangen General editing: Gabriele Pollok Siemens AG, E CC MCC R, Erlangen 14 Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Siemens HA 26.11 2008

Published by and copyright 2008: Siemens AG Energy Sect Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens AG Energy Sect Power Distribution Division Medium Voltage Postfach 3240 91050 Erlangen, Germany www.siemens.com/medium-voltage-switchgear F me infmation, please contact our Customer Suppt Center. Phone: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail: suppt.energy@siemens.com Order No. E50001-K1426-A101-A3-7600 Printed in Germany Dispo 31602 KG 10.08 X.X 16 En 6101/15462 103149 Printed on elementary chline-free bleached paper. All rights reserved. If not stated otherwise on the individual pages of this catalog, we reserve the right to include modifications, especially regarding the stated values, dimensions and weights. Drawings are not binding. All product designations used are trademarks product names of Siemens AG other suppliers. If not stated otherwise, all dimensions in this catalogaregiveninmm. Subject to change without pri notice. The infmation in this document contains general descriptions of the technical options available, which maynotapplyinallcases.therequiredtechnical options should therefe be specified in the contract. Electrokavir Co. Under License of SIEMENS Central Office: KAVIR Bldg. No. 374 Mirdamad Ave, TEHRAN 15189 - IRAN _ P.O.Box: 15189-65514 Tel: +98 21 88677210 (10Line), 88788125, 88796486, 88783156, Fax: +98 21 88789448 Web: www.electrokavir.com Email: info@electrokavir.com Facty: KHEZRABAD, YAZD - IRAN Tel: +98 351 7272974-6 Fax: +98 351 7272386 www.siemens.com/energy