P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

Similar documents
P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

Achieving Required Safety Levels Using a Pneumatic Safety Exhaust Valve

Control Reliable Double Valves with Total Dynamic Monitoring & Complete Memory

ROSS CONTROLS. Double Valves for Control Reliable Energy Isolation.

Selecting & Integrating Safety Exhaust Valves White Paper

What you Need to Know About Safety Exhaust Valves White Paper

ROSS CONTROLS. Double Valves for Control Reliable Energy Isolation.

Product Information. Safety Exhaust ROSS CONTROLS

CONTROLS ROSS SAFETY-RELATED PRODUCTS

CONTROLS ROSS SAFETY-RELATED PRODUCTS

Product Information. Safety Exhaust ROSS CONTROLS

Safety Exhaust Valve Integration Guide

UNI EN ISO EN

4 Redundant Control System

Control Reliable Monitored Valves

Redundant Control System

ROSS CONTROLS. Explosion Proof Valves 27 & 21 Series, DM 2 Series C. ISO Valves W60 & W64 Series.

CONTROLS SAFETY EXHAUST (DUMP) CONTROL RELIABLE ENERGY ISOLATION DOUBLE VALVES M35, DM 1, DM 2 SERIES.

Hazardous Locations ROSS CONTROLS

Safe Cylinder Control and Stop and Load Holding Valves ROSS CONTROLS

ROSS CONTROLS. Double Valves for Clutch/Brake Control

Product Information ROSS CONTROLS

ROSS CONTROLS. CrossMirror 77 And CM Series. Double Valves for Cylinder Return to Home Position.

Session Four Applying functional safety to machine interlock guards

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

Pneumatic Machine Safeguarding Solutions

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

Datasheet. Electrical Switching / Locking

BULLETIN 510. The Guiding Light to Pneumatic Machine Safeguarding. Complete Your System with ROSS CONTROLS Safety-Related Products.

Model 277EC ENGINE IDLE LIMITER

Competence in Functional Safety MANUAL. principle and typical applications

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Safety Sensor CSS 180 Product Information

AZM300 More than just a solenoid interlock

MEP-A Press safety valves

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

Product Information. RSe Series ROSS CONTROLS

proat Head Options & Ordering Information Part Number Item No. Description T6 ITM proat Head

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication

Clutch/Brake Control Monitored Double Valves

SECTION B: SYSTEM OPERATING COMPONENTS

Bus / Coach Door Obstruction Detection

The New Filter Valve Technology

SMSIL-4THGU-E ISSUE: 12/12 SIL-SAFETY MANUAL. Upgrade Series Actuators

Product Information ROSS CONTROLS

NHP SAFETY REFERENCE GUIDE

Pneumatic Valve 4V100 Series

Product Information. 16 Series ROSS CONTROLS

HIGH POWER SOLENOID DRIVER 1

SECTION B1: MACHINE COMPONENTS

Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Control block VOFA with safety function

Electropneumatic pressure regulator EPP4 Series

Energy Isolation Lockout & Soft Start Valves ROSS CONTROLS

DM2 Series D 3/2 Double Valves

Directional servo-valve of 4-way design

Maintenance Instructions & Parts List

Angle seat valve with diaphragm actuator VZXA-...-M

IOTA ONE OPERATING MANUAL AND SETUP INSTRUCTIONS IOTA ONE. Please Read this Instruction Manual COMPLETELY Before Operating the System IOTA ONE

Angle seat valve with piston actuator VZXA-...-K

MONITORED HYDRAULIC VALVE SYSTEMS

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

NHP SAFETY REFERENCE GUIDE

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

Compact Valves 16 Series

Oil Streak Air-Oil Generating Unit

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

DM 2 Series D 3/2 Double Valves

Safety Control HR1S-AC. Safety Relay HR1S-AC


SOLENOID VALVES AND PNEUMATIC VALVES

DY Series 1-Piece Ball Valves. Catalog 1001C-A. July 2012 欧陆传动

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves

FITTINGS CHEST FITTINGS CHEST. Get organized with the Pneuforce Fittings Chest!

Pneumatic Division North America Richland, MI 49083

CIRCLE SEAL CONTROLS

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

2/2-Way Pressure Relief Valve CX DBV (Right-Angle Design)

ROSS CONTROLS. Compact Valves 16 Series.

THE INSIDE STORY OF THE QPV OR MPV:

SureFire II Lubricator

J1 Plug Pin Identification

AS-Interface Installation Manual. ASAHI / AMERICA, Inc. Thermoplastic Valves and Piping Systems

DME Valve Gate Controls

pneumatic function fittings

* Evaluated by TÜV Rheinland (Report No. 968/FSP /16) in accordance with ISO and ISO

TWO HAND NON-TIE-DOWN CONTROLS SC SERIES

Protecting People, Industry and Productivity

DG 060 DG 061 DG 062 DG 063 DG 064 for Pressure and High Pressure Filters Operating pressure up to 600 bar Response/switching pressure up to 5,0 bar

Technical Data Sheet

Maxon Shut-Off and Vent Valves General Purpose

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Data Sheet. I/P and E/P converters. RS stock numbers ,

J3C-H20 25Nm Smart Electric Valve Actuator

Series 581 ISO Pneumatic Directional Control Valves

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

J1 Plug Pin Identification

Transcription:

aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P33T Series Redundant Safety Exhaust Valve Bulletin 0700-B3 ENGINEERING YOUR SUCCESS.

Redundant Safety Exhaust Valve Features 3 Proven control reliable technology with integrated soft start Soft start application of air to the system when energized; can be adjusted for slower or faster buildup of system pressure Rapid exhaust of downstream air when de-energized to remove stored energy and allow safe access Control Reliable Category 4 (Cat 4); Performance Level e (PLe) in accordance with Machine Directive - EN ISO 3849-. (certification pending) Options: Port size Cv Inlet Outlet Transducer to to 3 Weight kg (lb) Part number* 3/4 3/4 w/o transducer 3.7 8.5 7.3 (6.) P33TA96RG4FCN 3/4 3/4 w/ transducer 3.7 8.5 7.4 (6.3) P33TA96RG4GCN * NPT port threads. For BSPP threads, replace 9 in the part number with a. Memory, monitoring, and air flow control functions are integrated into two identical valve elements. Valves lock-out if asynchronous movement of valve elements occurs during actuation or de-actuation, resulting in a residual outlet pressure of less than % of supply. Reset can only be accomplished by the integrated electrical (solenoid) reset. Cannot be reset by removing and reapplying supply pressure. Basic 3/ normally closed valve function: Dirt tolerant, wear compensating poppet design for quick response and high flow capacity. LED indicators of main solenoid operation, reset solenoid operation, and status indicator condition. Optional transducer for monitoring of downstream pressure in the system. Dual exhaust silencers included. Not for use with clutch / brake applications. For use in conjunction with a safety relay or safety PLC.

Redundant Safety Exhaust Valve Functions De-Actuated / Actuated Valve de-actuated (ready-to-run): Soft start and redundant safety exhaust valve in the at rest condition Air enters crossover passages through stem and valve body area Crossover passages and timing chambers are pressurized Pressure balance holds internals in the de-energized condition The green Status LED will be illuminated indicating the valve is ready to run.. RESET Valve actuated: Solenoid and Solenoid energize simultaneously within 00ms, shifting the pilot valves Timing chambers experience a pressure drop as each element shifts to its actuated state Exhaust poppets seat blocking the exhaust Flow restriction at inlet removed Inlet poppet shifts allowing flow downstream Soft start piston remains un-shifted supplying a limited air flow to the redundant safety exhaust valve internals As downstream pressure reaches approximately 60% of line pressure the soft start piston shifts supplying full pressure downstream Solenoid, Solenoid and the green Status LED's will be illuminated indicating the valve is operating properly.. RESET Soft start function: 00% 60% 0% Start signal Switching time delay 3 Gradual pressure build up 4 Operating pressure p (=p )

Redundant Safety Exhaust Valve Functions Fault / Reset Valve fault and lock-out: If Solenoid and Solenoid do not energize simultaneously within 00ms, a fault occurs A timing chamber will be exhausted before the correct internal shifting has occurred Valve will be latched out - No return piston pressure - No pilot pressure The red Status LED will be illuminated indicating the valve is in fault and lock-out must be reset.. RESET Valve reset (electrical or manual): Fault: Electrical Reset procedure: - Remove the electrical signal from the main coils - Ensure there is air supplied to the valve - Energize the reset solenoid momentarily (minimum of 00 ms) - Allow 00 ms delay after removing the reset signal prior to re-energizing the main coils (Solenoid and Solenoid ) Fault: Manual Reset procedure: - Remove the electrical signal from the main coils - Ensure there is air supplied to the valve - Depress the manual reset button A momentary shift of the reset valve solenoid via electrical or mechanical operation, provides a pneumatic signal The Reset green LED will indicate when the solenoid is energized Provides pressure under the reset pistons to push both internals to the home position Both timing chambers are exhausted De-energizing the reset allows the reset to return to its home position The pressure chambers will quickly refill The green Status LED will be illuminated once the valve is reset Control Signal Feedback Pressure Transducer (Optional) Manual Reset Inlet.. RESET.. RESET

Machinery Directive Overview Parker is protecting your most valuable assets In the context of the Machinery Directive, the goal is to protect people and the environment from accidents caused from all types of machinery EN 954- has now been superseded by EN 3849- (safety of machines; safety-related parts of control systems, part : general design principles) and EN 606 (safety of machines; functional safety of electrical, electronic and programmable electronic control systems). A significant revision in these standards is the approach that is taken to the assessment of safety-related controls systems, especially with regard to modern electronic control circuits. In essence, the new standard builds on the existing categories within EN 954-, adding a new procedure for risk assessment. This is called a Performance Level (PL) and is associated with a given safety function, with definitions for diagnostic capabilities and common cause failures. This ensures that safety is not just focused on component reliability, but instead introduces common sense safety principles such as redundancy, diversity, and fail-safe behavior. PL s are based on the original B,,, 3, 4 safety categories and are described by the following parameters: Category (structural requirements) Mean time to dangerous failure (MTTFd) Diagnostic coverage (DC) Common cause failure (CCF) With EN ISO 3849- and EN 606 the performance of each safety function is specified as either: PL (Performance Level, PL a Pl e ) in the case of ISO3849- SIL (Safety Integrity Level, SIL 3) in the case of EN 606 Determining PL according to EN ISO 3849- S S F F F F P P P P P P P P PL r Risk Parameters S = Severity of Injury S = Slight (usually reversible) injury S = Severe (usually irreversible) injury, including death F = Frequency and/or duration of exposure to hazard F = Rare to often and/or short exposure to hazard F = Frequent to continuous and/or long exposure to hazard P = Probability of avoiding or limiting harm P = Possible under certain conditions P = Hardly possible a, b, c, d, e = targets of the safety related performance level a b c d e Low Contribution To Risk Reduction S - Slight Injury S - Serious Injury F - Seldom or Short F - Frequent or Long P - Avoidable P - Unavoidable High Contribution To Risk Reduction When determining the performance level; the greater the risk, the higher the requirements of the control system. The level of each hazardous situation is classified in five stages, from a to e. With PL a the control function s contribution to risk reduction is low, while at PL e it is high. The risk graph above can be used as a guideline to determine the required performance level PL r for safety function. Categories defined according to EN ISO 3849- Category Category B Category Category Category 3 Category 4 Summary When a fault occurs it can lead to the loss of the safety function When a fault occurs it can lead to the loss of the safety function, but the MTTF d of each channel in Category is higher than in Category B. Consequently the loss of the safety function is less likely. Category system behavior allows that: the occurrence of a fault can lead to the loss of the safety function between the checks; the loss of the safety function is detected by the check. SRP/CS to Category 3 shall be designed so that a single fault in any of these safety related parts does not lead to the loss of the safety function. Whenever reasonably possible the single fault shall be detected at or before the next demand upon the safety function. SRP/CS to Category 4 shall be designed so that a single fault in any of these safety related parts does not lead to the loss of the safety function, and the single fault is detected on or before the next demand upon the safety functions, e.g. immediately, at switch on, at end of a machine operation cycle. If this detection is not possible an accumulation of undetected faults shall not lead to the loss of the safety function By offering the best pneumatic safety for your machines

5.. RESET Accessories & Technical Information Technical information Pilot Solenoids: According to VDE 0580 Enclosure rating: According to DIN 400 50 IP 65 Connector socket: According to DIN 43650 Form A Three solenoids, rated for continuous duty Standard voltages: 4VDC Power consumption (each solenoid): For primary and reset solenoids:. watts on DC Enclosure rating: IP65, IEC 6059 Electrical connection: M, 5-pin Ambient temperature: 5 F to F (-0 C to 50 C) Media temperature: 40 F to 75 F (4 C to 80 C) Flow media: Compressed Air, filtered to minimum 40 micron Inlet pressure: 30 to 50 PSIG ( to 0 bar) Pressure switch (status indicator) rating: 5 amps at 30 volts DC. Monitoring: Dynamically, cyclically, internally during each actuating and de-actuating movement. Monitoring function has memory and requires an overt act to reset unit after lockout. Mounting orientation: Vertically with pilot solenoids on top Port threads: 3/4 NPT, 3/4 BSPP Control reliable: Category 4 (Cat 4); performance Level e (PLe) in accordance with Machine Directive - EN ISO 3849- (certification pending) Dimensions mm (inches) 6.3 (.64) 73.8 (0.78) Control Signal Feedback Pressure Transducer (Optional) Manual Reset Inlet - + (+) Increase Time (-) Decrease Time LED Status Lights Outlet Accessories Description Part number Black grill 834C05-00 Body connector P3KA00CB Cables M, 5-pin female to flying lead cable, TPE; m (6.6 ft) RKC 4.5-/S587 M, 5-pin male to flying lead cable, TPE; m (6.6 ft) RSC 4.5-/S587 Port block kit / NPT P3KA94CP 3/4 NPT P3KA96CP / BSPP P3KA4CP 3/4 BSPP P3KA6CP / BSPT P3KA4CP 3/4 BSPT P3KA6CP Pressure switch 7A30-00 Pressure transducer (optional) 3H30-00 T-bracket w/ body connector P3KA00MT T-bracket (fits to body connector or port block) P3KA00MB Silencer(s) 3/4" 5500A503 Solenoid (main & reset) 57B796-00 Square flush mounting gauge kit, 0-60 psig K45SCR60 Valve wiring BROWN (+4 Volts DC) 5-Pin A Code Female Connector (Feedback) BLACK 4 3 (N.C. Status Contact) 5 GRAY 5 GRAY 5 (Equip Ground) Reset WHITE WHITE BROWN Input (N.O. Status (Sol ) (+4 Volts DC) Power + Contact) BLUE (Common) 5-Pin A Code Male Connector (Control Signal) BLUE 3 4 BLACK (Common) (Sol ) 5-Pin A Code Female Connector (Digital Pressure Transducer Wiring (optional)) Power Input Digital Output Signal Analog 4 3 Digital Output Signal Output Signal 45.5 (5.73) 4.3 (.63) 36.0 (5.35) 00% 60% Adjustable Soft Start 47.6 (5.8) Angle Mounting Bracket 9. (0.75) 9.5 (0.375) 8.6 8.3 (3.) (0.34) 6.4 (0.5) 46. (.8) 8X R 0.3 R 0.063 90 76. (3.0) 76. (3.0) 0% 3 4 Start signal Switching time delay Gradual pressure build up Operating pressure p (=p ). (0.44) 76. (3.0) 98.4 (3.875) Note: Mounting bracket and installation screws included and required to install unit in the system. Bulletin 0700-B3 4/04 Parker Hannifin Corporation Pneumatic Division 8676 E. M89 P.O. Box 90 Richland, MI 49083 USA Tel: 69 69 5000 Fax: 69 69 5385 Applications Engineering Phone: 877 3 4PDN Option # E-mail: pdnapps@parker.com Customer Support Phone: 877 3 4PDN Option # E-mail: pdncustsvc@parker.com Web site: www.parker.com/pneumatics www.parker.com/globalfrl