product specification

Similar documents
Product Data Sheet 4184 NXHH

Product Data Sheet 4414/2H

Product Data Sheet 4184 NGX

Product Data Sheet 4184 NXHH

Product Data Sheet 8414 NGH

Product Data Sheet 3214 JH3-195

Product Data Sheet DV4118 N

Product Data Sheet 3214 J/2H3F-191

4314/17T. Product Data Sheet INDEX

Product Data Sheet 8314 HR-197

Product Data Sheet DV5214 NU

Product Data Sheet 8412 NHU-519

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 614 N/2HH-169 The engineer's choice

Product Data Sheet 8412 N/ The engineer's choice

Product Data Sheet 624 NR. The engineer's choice

Product Data Sheet 4184 N/17X. The engineer's choice

Product Data Sheet 632 NU-006

Product Data Sheet ACi 4420 MLR

Product Data Sheet ACi 4420 HHR

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL

PART NO: FD2460-C0151E2AL CUSTOMER APPROVAL

INDUSTRIAL THERMAL MANAGEMENT. Filter fans FL-Series

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

PART NO: FD1212-A2251G2AL. DATE : June 9, 2010 CUSTOMER APPROVAL

AC centrifugal fan. backward curved

CUSTOMER: PART NO: FD1212-A1051E2AL. DATE : January CUSTOMER APPROVAL. Taiwan. Mainland China(F1)

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

AC axial fan. blades with special design (K series) with guard grille for full nozzle

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

Model Number Structure

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

EPS/ELA-Series User Manual EPS/ELA 250W

Model Number Structure

MOONS SM servo motors offer a great combination of Power, Precision and Value:

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

AC centrifugal module - RadiCal

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

CUSTOMER: ARCERA EU MODEL NO: 5115 (CeraDyna Fan) PART NO: FW2451-A1051C2AL DATE: CUSTOMER APPROVAL. Taiwan

AC axial fan. sickled blades (S series) with full square nozzle

Model Number Structure

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD2412PTB1-6A

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

AC centrifugal fan. backward curved

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Centrifugal pumps. Main catalogue.

FBA08A (80 X 25.5 L )

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

Brushless DC Axial Fans

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

Information. DC axial fans. DC axial fans. DC axial fan overview 27 DC axial fan / DC diagonal fan

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial fan. straight blades (A series) with full round nozzle

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 92X92X25 mm M O D E L : KD1209PTB1 P/N : (2).H

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

SITESTAR ELECTRONICS CABINET DESCRIPTION

5-Phase Stepper Motor

Table of contents. Three-phase asynchronous motors DA

General_technical_data Series

AC axial fan. sickled blades (S series) Wall ring with guard grille

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 40X40X10 mm M O D E L : KD1204PFS2-8

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Knürr CoolBlast. Top-Mounting Fan for Miracel

BPF. Centrifugal Plug Fans

Immersion Pumps PMS and PMS-T sealless

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

AC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

PREPARED 研發處 研發處 研發處 林佑亮 吳靜心 李群雪 AK1751HB DATE 研發處 P.S. AC FAN (RoHS) REV 發行章

AC centrifugal fan. forward curved, dual inlet with housing (flange)

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

1SVC F SVC F 0607 R100.20/30 R100.45

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

A22NK. Key-type Selector Switches

1.5KW DC-DC Converter Specification

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

MB Series AC Centrifugal Blowers

Switching Power Supply

AC axial fan. sickled blades (S series) with guard grille for full nozzle

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

LED Driver Linear / area dimming

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

Energy-saving motors (ESM)

Ionizer (Nozzle type) Series IZN10

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

SOLSTART Instruction Manual

3 Phase Power Systems - Designed for Canada

Technical Documentation Regenerative Turbine Pump with Canned Motor Y-2951-W-MM

Transcription:

4414 ML Customer specification: No Version: 1.0 Created: 16.09.2011 INDEX 1 General... 2 2 Mechanics... 2 2.1 GENERAL... 2 2.2 MOTOR... 2 2.3 CONNECTIONS... 3 3 Operating Data... 4 3.1 OPERATING DATA - ELECTRICAL INTERFACE - INPUT... 4 3.2 ELECTRICAL OPERATING DATA... 4 3.3 OPERATING DATA - ELECTRICAL INTERFACE -OUTPUT... 4 3.4 ELECTRICAL FEATURES... 5 3.5 AERODYNAMIC... 5 3.6 SOUND DATA... 6 4 Environment... 7 4.1 GENERAL... 7 4.2 CLIMATIC REQUIREMENTS*)... 7 4.3 MECHANICAL REQUIREMENTS... 8 4.4 EMC... 8 5 Safety... 8 5.1 ELECTRICAL SAFETY... 8 5.2 APPROVAL TESTS... 8 6 Reliability... 8 6.1 GENERAL... 8 6.2 ADDITIONAL DATA... 8 Special features according to QMH 2-5.4.7 and company standard 1-23.00 have the following definitions: "A" : Product features or process parameters which influence the safety of a product or the compliance of legal requirements. (Must not necessary verified and documented 100%. Standards and legal requirements must be considered.) "FK" : Product features or process parameters which influence the fit and function of a product or which have to be controlled or documented for some other reasons (e.g. Customer requirements). page 1 of 8

1 General Fan type Fan Rotational direction looking at rotor clockwise FK Airflow direction Air outlet over struts FK Bearing system Ball bearing Lubrication see sectional drawing of the bearing Mounting position any Balancing grade 16,0 FK Impeller weight 118,0 g 2 Mechanics 2.1 General Width Height Depth Diameter Weight Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 119,0 mm 119,0 mm 38,0 mm 0,0 mm 0,270 kg Plastic Plastic wire outlet corner: 80 Ncm remaining corners: 80 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 2.2 Motor Type of motor Electronically commutated external rotor Diameter of the motor 35,0 mm Height of the motor 10,0 mm Number of phases 1 Number of windings 2 Operating mode Continuous duty Insulation material class E page 2 of 8

2.3 Connections Electrical connection Length of lead wire Length of tube Wires 310 mm see drawing +- 10,0 mm Wire gauge (AWG) 24 Insulation diameter 1,10 mm Plug see drawing Contact see drawing Colour Operation Wire 1 red + UB Wire 2 blue - GND page 3 of 8

3 Operating Data 3.1 Operating Data - Electrical Interface - Input Control input 3.2 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; Motor axis horizontal;warm-up time before measuring 5 minutes (unless otherwise specified).in the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: corresp. to free air flow (see section 3.5) I: corresp. to arithm. mean current value Features Condition Symbol Values Voltage range p = 0 U 12,0 V 28,0 V Nominal voltage p = 0 U N 24,0 V Power consumption p = 0 0,75 W 3,2 W 4,5 W P +- 17,5 % +- 12,5 % +- 15,0 % 0001 Current consumption p = 0 63 ma 132 ma*) 162 ma I +- 17,5 % +- 12,5 % +- 15,0 % 0001 Speed p = 0 1.540 1/min 3.000 1/min*) 3.415 1/min n +- 12,5 % +- 7,5 % +- 10,0 % 0001 Starting current consumption < 1.040 ma *) Attention: Marked values are "FK" features 3.3 Operating Data - Electrical Interface -Output Tacho type Alarm type page 4 of 8

3.4 Electrical Features Electronic function Reversed polarity protection Rectifying diode A Max. residual current at Un IF <= 50 ua Locked rotor protection Auto restart A Locked rotor current at Un approx. 1.040 ma Clock signal t3/t4 at locked rotor Typical: 0,5 s / 2,8 s 3.5 Aerodynamic Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; In the intake and outlet area should not be any solid obstruction within 0,5 m. a.) Operation condition: 3.000 1/min at free air flow Max. free-air flow ( p = 0 / = max.) 168,0 m3/h FK Max. static pressure ( p = max. / =0) 85 Pa FK page 5 of 8

3.6 Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 db(a) For further measurement conditions see section 3.5 a.) Operation condition: 3.000 1/min at free air flow Optimal operating point Sound power level at the optimal operating point 92,0 m3/h @ 32 Pa 5,1 bel(a) page 6 of 8

Sound pressure level at free air flow, measured in rubber bands 40,0 db(a) 4 Environment 4.1 General Min. permitted ambient temperature TU min. -20 C Max. permitted ambient temperature TU max. 80 C Min. permitted storage temperature TL min. -40 C Max. permitted storage temperature TL max. 80 C 4.2 Climatic requirements*) Humidity requirements humid heat, constant; according to DIN EN 60068-2- 78, 14 days Water exposure Radiation exposure Dust requirements Salt fog requirements Harmful gas requirements *) Permittet application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact. page 7 of 8

4.3 Mechanical requirements Please require severity levels and specification parameters from the responsible development departments 4.4 EMC not specified 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25 C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25 C measured with U=500 VDC for 1 min. Air and leakage distances Protection class 500 VAC / 1 Min. 500 VAC / 1 Sec. A RI > 10 MOhm 1,0 mm / 1,2 mm III 5.2 Approval Tests CE UL VDE CSA CCC Yes Yes / UL audited by CSA according to UL507, Electric Fans Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment - Part 1 Safety - Connection to a SELV circuit. Yes / C22.2 No. 113-M1984 Fans and Ventilators No The approval tests are observed to: Maximal permitted operating voltage (see section 3.1) and max. permitted ambient temperature TU max. 6 Reliability 6.1 General 6.2 Additional Data not specified page 8 of 8