Product Data Sheet 4184 N/17X. The engineer's choice

Similar documents
Product Data Sheet 614 N/2HH-169 The engineer's choice

Product Data Sheet 8412 N/ The engineer's choice

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 3214 JH3-195

Product Data Sheet 624 NR. The engineer's choice

Product Data Sheet 4414/2H

Product Data Sheet 4184 NXHH

Product Data Sheet 8412 NHU-519

Product Data Sheet 4184 NXHH

Product Data Sheet 632 NU-006

4314/17T. Product Data Sheet INDEX

Product Data Sheet 4184 NGX

Product Data Sheet 8414 NGH

product specification

Product Data Sheet DV5214 NU

Product Data Sheet 3214 J/2H3F-191

Product Data Sheet DV4118 N

Product Data Sheet ACi 4420 HHR

Product Data Sheet 8314 HR-197

Product Data Sheet ACi 4420 MLR

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

PART NO: FD2460-C0151E2AL CUSTOMER APPROVAL

AC axial fan. blades with special design (K series) with guard grille for full nozzle

AC centrifugal module - RadiCal

Energy-saving motors (ESM)

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

AC centrifugal fan. backward curved

AC axial fan. sickled blades (S series) with full square nozzle

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL

PART NO: FD1212-A2251G2AL. DATE : June 9, 2010 CUSTOMER APPROVAL

AC centrifugal fan. backward curved

Immersion Pumps PMS and PMS-T sealless

EPS/ELA-Series User Manual EPS/ELA 250W

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

Information. DC axial fans. DC axial fans. DC axial fan overview 27 DC axial fan / DC diagonal fan

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

CUSTOMER: ARCERA EU MODEL NO: 5115 (CeraDyna Fan) PART NO: FW2451-A1051C2AL DATE: CUSTOMER APPROVAL. Taiwan

AC centrifugal fan. forward curved, dual inlet with housing (flange)

Centrifugal pumps. Main catalogue.

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

Thermal Overcurrent Circuit Breaker 3120-F...

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

CUSTOMER: PART NO: FD1212-A1051E2AL. DATE : January CUSTOMER APPROVAL. Taiwan. Mainland China(F1)

Model Number Structure

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD2412PTB1-6A

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

Immersion Pumps PRG sealless

Minimum 18 in-lb Torque

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Magnetic and Hydraulic-Magnetic Circuit Breaker

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

General_technical_data Series

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Thermal Circuit Breaker 3120-F...

AC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

AC centrifugal fan. forward-curved, dual-intake with housing (without flange)

Model Number Structure

General_technical_data Series

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Type 2REX-A. Oil & Gas / Heavy Industry

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

FBA08A (80 X 25.5 L )

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Electronic Circuit Breaker ESS20-0..

Ionizer (Nozzle type) Series IZN10

Thermal Overcurrent Circuit Breaker 3120-F...

Electric Immersion Pumps PRT and PRA, sealless

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Thermal Overcurrent Circuit Breaker 3120-F...

3-Phase Military AC-DC Power Supply 3-Phase, VrmsL-L

AC axial fan. straight blades (A series) with full round nozzle

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 92X92X25 mm M O D E L : KD1209PTB1 P/N : (2).H

Model Number Structure

AC axial fan. sickled blades (S series) with guard grille for full nozzle

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

VORTICENT C E RANGE Centrifugal fans

PRODUCT SPECIFICATION File: EA-520H1U-01 Date: Apr., 7, 2005

Thermal Overcurrent Circuit Breaker 3130

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

1.5KW DC-DC Converter Specification

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Thermal Overcurrent Circuit Breaker 3120-F...

Versatile and Powerful

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 40X40X10 mm M O D E L : KD1204PFS2-8

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

AC axial fan. sickled blades (S series) Wall ring with guard grille

AC centrifugal fan - RadiCal

Automation Systems Drive Solutions Controls Inverters Motors Gearboxes Engineering Tools

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Minimum 27 in-lb torque

Transcription:

Product Data Sheet 4184 N/17X The engineer's choice

4184 N/17X INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical Interface - Output... 5 3.3 Electrical Features... 6 3.4 Aerodynamics... 7 3.5 Sound Data... 8 4 Environment... 8 4.1 General... 8 4.2 Climatic Requirements... 8 5 Safety... 9 5.1 Electrical Safety... 9 5.2 Approval Tests... 9 6 Reliability... 9 6.1 General... 9

1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft Fan Clockwise Air intake over struts Ball bearing Any 2 Mechanics 2.1 General Width Height Depth Mass Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 119,0 mm 119,0 mm 38,0 mm 0,390 kg Metal Plastic Wire outlet corner: 170 Ncm Remaining corners: 300 Ncm ISO 4762 - M3 degreased, without an additional brace and without washer 2.2 Connections Electrical connection Plug Lead wire length L = 310 mm Tolerance Wire size (AWG) 22 Insulation diameter 1,70 mm Plug See drawing Contact See drawing +- 10,0 mm Wire Color Operation 3 white Alarm The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery. 11/02/2017 page 3 of 10

3 Operating Data 3.1 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; Motor axis horizontal; warm-up time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: corresp. to free air flow (see chapter aerodynamics) I: corresp. to arithm. mean current value Features Condition Symbol Values Voltage range U 18 V 32 V Nominal voltage U N 24 V Power consumption p = 0 3,2 W 5,9 W 6,2 W Tolerance P +- 25 % +- 25 % +- 25 % 0010 Current consumption p = 0 180 ma 245 ma 195 ma Tolerance I +- 25 % +- 25 % +- 25 % 0010 Speed p = 0 2.450 1/min 3.200 1/min 3.200 1/min Tolerance n +- 12,5 % +- 2 % +- 2 % 0010 Starting current consumption 1.200 ma 11/02/2017 page 4 of 10

3.2 Electrical Interface - Output Alarm type /17 (high = ok, open collector) Features Note Values Alarm operating voltage U BA <= 60 V Alarm signal Low U A low I sink: 2 ma <= 0,4 V Maximum sink current I sink 20 ma External resistor External resistor Ra from UBA to UA required. All voltage measured to GND. Alarm start-up delay time t 6 <= 15 s Alarm trip speed limit n G 1.500 1/min Tolerance +- 100 1/min Alarm at sense failure Alarm latch Alarm isolated from motor No No No 11/02/2017 page 5 of 10

3.3 Electrical Features Electronic function Reversed polarity protection Max. residual current at U N Locked rotor protection Locked rotor current at U N Clock signal at locked rotor Speed-Controlled Rectifying diode I F <= 20 ma Auto restart I block approx. 1.200 ma t 3 / t 4 typical: 0,4 s / 10 s 11/02/2017 page 6 of 10

3.4 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. a.) Operation condition: 3.200 1/min at free air flow Max. free-air flow ( p = 0 / = max.) 168,0 m3/h Max. static pressure ( p = max. / =0) 100 Pa 11/02/2017 page 7 of 10

3.5 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 db(a) For further measurement conditions see chapter aerodynamics. a.) Operation condition: 3.200 1/min at free air flow Optimal operating point Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 104,0 m3/h @ 40 Pa 5,6 bel(a) 49,0 db(a) 4 Environment 4.1 General Min. permitted ambient temperature TU min. -30 C Max. permitted ambient temperature TU max. 75 C Min. permitted storage temperature TL min. -40 C Max. permitted storage temperature TL max. 80 C 4.2 Climatic Requirements Humidity requirements Water exposure Dust requirements Salt fog requirements humid heat, constant; according to DIN EN 60068-2-78, 14 days None None None Permitted application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact. Please require severity levels and specification parameters from the responsible development departments. 11/02/2017 page 8 of 10

5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25 C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25 C measured with U=500 VDC for 1 min. Clearance / creepage distance Protection class 500 VAC / 1 Min. 500 VAC / 1 Sec. RI > 10 MOhm 1,0 mm / 1,2 mm III 5.2 Approval Tests CE EC Declaration of Conformity Yes EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes / UL507, Electric Fans VDE Association for Electrical, Electronic and Information Technologies Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment CSA Canadian Standards Association Yes / C22.2 No. 113 Fans and Ventilators CCC China Compulsory Certification Not applicable 6 Reliability 6.1 General 11/02/2017 page 9 of 10