AG 400 relay - Gold plated, 4 contacts

Similar documents
N.S1-P relay - Signalling, post

Description The EA 112 socket has crimp contacts to allow rear connection on the socket.

FR circuit breaker - hydraulic magnetic,

PDR circuit breaker - Ground fault Datasheet

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

RBR circuit breaker - Remote operated

AR circuit breaker - Hydraulic magnetic,

ER circuit breaker - Hydraulic magnetic,

Energy and traction control solutions

CR circuit breaker - hydraulic magnetic,

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic Overcurrent Circuit Breaker

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

General Purpose Relay

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

Miniature Intermediate Power Relay HY

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

General Purpose Relay

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Model Number Structure

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

MMC RTX series EN3716

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

High Performance Thermal-Magnetic Circuit Breakers 410/520/

EPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

RU Series Universal Relays

General Purpose Relay

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

F-Series. Circuit Breaker

Functions The Series 19 incorporates the following functions: Indicator Pushbutton Illuminated pushbutton

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

F-Series. Circuit Breaker

General_technical_data Series

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Electronic Circuit Breaker ESS20-0..

Industrial Relay KML(1C, 2C)

Description. Positive safety relays

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Simulator switch, magnetic operation

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Thermal Overcurrent Circuit Breaker 3120-F...

General Purpose Relay

Thermal Overcurrent Circuit Breaker 3120-F...

Date received into service; / /.

55 Series - Miniature General Purpose Relays 5-10 A

Thermal Overcurrent Circuit Breaker 3120-F...

PPT 802, Proximity Probe Transducer System

Features. Description. Table of Contents

Magnetic and Hydraulic-Magnetic Circuit Breaker

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

Thermal Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Signal Signal Relays. Potter & Brumfield. R10 Series Relay

Latching SPST EPIC Sealed Contactor Amp Power Switching RoHS Compliant, all date codes

Thermal Overcurrent Circuit Breaker 3120-F...

Nominal operating voltage Maximum operating voltage C High temp test

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker 201/-WA

MICRO SWITCH INSTALLATION SHEET

BENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR:

02/11/2015

General purpose relays 6-10 A

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Features. * 2 Form C contact. * High switching capacity 60W, 125VA. * Fit standard 16 pin IC socket. * Epoxy sealed for automaitc-wave COIL

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

Thermal Overcurrent Circuit Breaker 3120-F...

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Thermal Overcurrent Circuit Breaker 3120-F...

Model Number Structure

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

KD1E Range Potential Indicators

Renewable Energy. Circuit Breakers and Disconnects

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

G-Series DIN-RAIL CIRCUIT BREAKER

HL (AZH) LIMIT SWITCHES

Magnetic and Hydraulic-Magnetic Circuit Breaker

REP Series. Environmentally-Sealed Rectangular Plastic Connectors

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ROPE THIMBLE P/N STP-40-SS P/N STP-50-SS PULL WIRE SHOULD BE STRAIGHT AND CLEAR OF OBSTRUCTIONS WIRE SUPPORT P/N STG-200, STG-200-SS

Type Terminal Coil Contact form Model

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

Magnetic and Hydraulic-Magnetic Circuit Breaker

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

CX-Series. Circuit Breaker

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Transcription:

- Gold plated, 4 contacts Datasheet Features Instantaneous relay Plug-in design with secure locking feature for maximum ease of maintenance 4 double make / double break C/O contacts (form Z), gold plated on silver Contact life (mechanical) of 00 million cycles -40 C...+80 C operating temperature Contacts cross pollution barrier Optional weld no transfer function Benefits Description The AG 400 relay has 4 double make / double break C/O contacts (form Z). The contacts are gold plated on hard silver. This relay is used when dry circuits route to socket are not identified. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be disconnected or other hardware removed for relay inspection or replacement). The resistance to impact and vibration is conform to standards in force for Railway Transported Equipment. Positive mechanical keying of relay to socket is built into relay and socket during manufacture and terminal identifications are clearly marked on identification plate that is permanently attached to the relay. Proven reliable Long life cycle Easy to maintain and replace Low life cycle cost No maintenance Railway compliancy NF F 62-002 Rolling stock - Instantaneous relays contacts and sockets NF F6-0/02 Fire behaviour - Railway rolling stock The AG 400 relays is pluggable in the following sockets: EA 02 A, EA 02 AF, EA 03 AF, EA 04 A, EA 04 AF, EA 0 AF, EA 2 AF. Application The AG 400 relay is designed for low level signals switching in dry circuit signal information. The relay is equipped with a contact pollution barrier in case of mixed load operation.

Functional and connection diagrams Timing diagram Relay pin correspondence Example: BG keying Relay pin correspondence a b c d 2 3 4 R P O C B D A S T N E F K J H W V L M G 2 3 4 (rear view of relay shown) X U Y Z a b c d N.B.: Transil not needed on VAC coil relays Led (V) option (respect polarity) D D2 D3 D4 Connection diagram B A C B A C B A C B2 A2 C2 B2 A2 C2 B2 A2 C2 B3 A3 C3 B3 A3 C3 B3 A3 C3 B4 D A4 C4 B4 D A4 C4 B4 D A4 C4 D2 D2 D2 D3 D3 D3 D4 D4 D4 VDC Models (no Transil protection) VDC Models (with Transil protection) VAC Models N.B.: Transil not needed on VAC coil relays. 2

Coil data - DC versions Keying Unom (VDC) Uoperating (VDC) () Coil resistance tol.: ± 8% at 20 C (2) Valid for closed relay. Pnom (W) Uhold (VDC) Udrop-out (VDC) R coil (Ω) () L/R (ms) (2) AG 24 6 / 33 3 3. 2. 8 30 FL 36 2 / 4 3 2 3. 430 30 DG 48 33 / 60 3 28. 4. 70 30 BG 72 48 / 90 3 40. 6. 700 30 SV 0 7 / 38 3 62 0 4000 30 EG 2 88/6 3 73 2 700 30 Coil data - AC versions Keying Unom (VAC) Uoperating (VAC) Pnom (VA) Uhold (VAC) Udrop-out (VAC) R coil (Ω) () L/R (ms) (2) SZ 80/40 3 6 0 4000 30 CG 220 76/242 3 29 2 000 30 () Coil resistance tol.: ± 8% at 20 C (2) Valid for closed relay. Contact data - dry circuit application (gold contacts) Contact configuration 4 C/O double break contact Contact design Stationary contacts 2 single contacts (contacts are in series) Movable contacts solid blade Contact resistance < 20 mω at A (carry only) Maximum contact ratings Operating 20 ma maximum at 72 VDC Carry only (no make and break) A maximum at VDC Minimum current ratings 0 ma at 2 VDC Contact material Stationary contacts Gold plated over hard silver Movable contacts Gold over hard silver overlay laminated to copper 3

Contact design Change Over double break contacts Change Over double break contacts with Weld No Transfer option Electrical characteristics Dielectric strength Insulation resistance 2000 VAC, min between contacts 2600 VAC, min between contacts, coil and frame > 000 MΩ at 00 VDC Mechanical & environmental characteristics Vibration NF F 62-002 The tests are conducted in the X, Y, Z planes at frequency between 0 & 0 cycles (sinusoidal) at 2 g Shock NF F 62-002 Tests are applied in both directions in the X, Y & Z planes. Then successive shocks are administered consisting of the positive component of sinusoidal with a value of 30 g, 8 ms Other vibration and shock tests can be performed on request Mechanical life > 00 x 0 6 operations Weight 300 g Temperature -40 C...+80 C Humidity 93% RH, 40 C for 4 days Salt mist % NaCl, 3 C for 4 days Protection IP40 (relay on socket) Fire & smoke Materials: Polycarbonate (cover) / polyester melamine (base) Note: These materials have been tested for fire propagation and smoke emission according standards NF F 6-0, NF F 6-02. 4

Dimensions (mm) Used with locking brackets Used with wire locking spring

Dynamic relay selection curve No AC Current breaking capacity versus life expectancy in millions of cycles. Rate of contacts opening and closing = 200 operations per hour. Curves shown for resistive load (Power Factor = ). Curve 2 3 4 VAC 220 2 48 24 60 0 40 30 20 4 0 3 Millions of Cycles 2, 2 0, 0,2 0, 0, 2 2, 3 4 6 7 8 0 2 Amps (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration) 6

Dynamic relay selection curve No 2 DC Current breaking capacity versus life expectancy in millions of cycles. Rate of contacts opening and closing = 200 operations per hour. Curves shown for inductive load: L/R= 20 ms continuous current L/R= 40 ms continuous current * By connecting 2 contacts in series, DC current breaking capacity increases by 0 % Curves -3 2-4 -6 7-8 VDC 220 2 48 24 20 Millions of Cycles 0 9 8 7 6 4 3 2 3 2 4 6 7 8, 0 0,2 0,2 0, 2 3 4 6 8 0 2 Amps (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration) 7

Dynamic relay selection curve No 3 DC Current breaking capacity versus life expectancy in millions of cycles. Rate of contacts opening and closing = 200 operations per hour. Curves shown for resistive load (L/R = 0). Continuous current. * By connecting 2 contacts in series, DC current breaking capacity increases by 0 % Curve 2 3 4 VDC 220 2 48 24 20 Millions of Cycles 0 9 8 7 6 4 3 2 3 4 2, 0 0,2 0,2 0, 2 3 4 6 8 0 2 Amps (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration) 8

Dynamic relay selection curve No 4 Maximum contact breaking capacity versus voltage for a given L/R. Rate of contacts opening and closing = 600 operations per hour. Curves shown for resistive load (L/R=0) and inductive loads. Continuous current. Life expectancy: 2 Millions of Cycles Curve 2 3 4 6 L/R= 0ms ms 20ms 40ms 60ms 00ms Volts 220 20 200 90 80 70 60 0 40 30 20 0 00 90 80 70 60 0 40 30 20 0 0 6 2 3 4 2 3 4 6 7 8 9 0 2 Amps (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration) 9

Dynamic relay selection curve No Maximum power interruption versus load time constant (L/R) for a given voltage. Curves shown for resistive loads. I = P/V. Curve 2 3 4 VDC 220 2 72 48 24 L R ms 00 90 80 70 60 4 8.3A 0 2 2A 40 30 3 6.6A 20 0 0 00 200 300 400 00 600 700 Watts (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration) 0

Dynamic relay selection curve No 6 AC Current breaking capacity versus life expectancy in millions of cycles. Rate of contacts opening and closing = 200 operations per hour. Values shown for inductive loads - Cos Ø = 0.7 Cos Ø = 0. Curves,3 &4 2, &7 6,9 &0 8, &2 Cos Ø = 0.3 VAC 220 2 48 24 60 0 40 30 20 0 2 0 Millions of Cycles 2, 6 7 8 9 2 3 4 0, 0,2 0, 0, 2 2, 3 4 6 7 8 0 2 Amps (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration)

Mounting possiblities / sockets EA 02 A EA 03 AF EA 04 A EA 2 AF Panel/flush mounting EA 02 A EA 02 AF EA 04 A EA 04 AF EA 2 AF Locking bracket (90843), rear connection, double Faston mm Wire locking spring (92683), rear connection, single Faston mm Locking bracket (90843), rear connection, single Faston x 0.8 mm Wire locking spring (92683), rear connection, single Faston x 0.8mm Wire locking spring (92683), rear connection, crimp contact Surface/wall mounting EA 03 AF* EA 0 AF* Wire locking spring (92683), front connection, M3 screw 6. mm ring terminals (2, mm 2 ) Wire locking spring (92683), front connection, single Faston mm * Mounting possibility on 3 mm rail EN 0022 by adding suffix D to the part number (see socket datasheet) Note: Keying of relay to socket can be specified by adding the keying letters in the part number. See all details in the related socket datasheet. 2

Spare parts Spare parts - order part numbers () () () () LOCKING BRACKET 90843 90846 () () SCREW FOR BRACKET METAL STRAP (2) METAL STRAP (4) C92720 P928060 (2) (3) P92806 WIRE LOCKING SPRING 92683 4390664 ROUND PLASTIC PLUGS 4492800 HEX. PLASTIC KEYS 4490678 LOCK PINS ASSY 2 SCREWS 906364 22903020 () Parts only for socket (2) Parts for relay and socket (3) Parts only for relay 3

Instructions Installation Install socket and connect wiring correctly according identification to terminals. Plug relay into socket. Reverse installation into socket not possible due to mechanical blocking by snap-lock. Don t reverse polarity of coil connection. Relays can be mounted (tightly) next to each other and in any attitude. Warning! Never use silicon spray near by relays Operation Before operating always apply voltage to coil to check correct operation. Long term storage may corrode the silver on the relay pins. Just by plugging the relay into the socket, the female bifurcated receivers will automatically clean the corrosion on the pins and guarantee a good connection. Do not use the relay in places with flammable gas as the arc generated from switching could ignite gasses. Maintenance Correct operation of relay can easily be checked as transparent cover gives good visibility on the moving contacts. When the relay doesn t seem to operate correct, please check presence of coil voltage. Use a multimeter. If LED is used, coil presence should be indicated. If coil voltage is present, but the relay doesn t work, a short circuit of suppression diode is possible (The coil connection was reversed). If relay doesn t work after inspection, please replace relay unit by a similar model. Send defective relay back to manufacturer. Normal wear and tear excluded. 4

Ordering scheme Configuration: AG 400 24 AG S C V F. Relay model 2. Nominal 3. Keying 4. Coil. Weld 6. LED 7. Cover 8. Language voltage OVP no transfer ind. type (test report) This example represents a AG 400 24 AG S C V F. Description: AG 400 series relay, Unom: 24 VDC, Keying AG, Transil coil protection, Weld no transfer, LED indicator, relay cover for wire locking spring, test report in English. Relay model AG 400 2 & 3. Nominal voltage and keying AG FKL DG BG US SV EG 24 VDC 36 VDC 48 VDC 72 VDC 96 VDC 0 VDC 2 VDC SZ CG VAC 220 VAC 4. Coil overvoltage protection No coil protection P Avalance diode coil protection S Transil coil protection (only with 400 type). Weld no transfer option Regular double break contacts C Weld no transfer 6. LED indicator No LED V LED voltage indicator 7. Relay cover type Relay cover with lock pins F Relay cover forwire locking spring 8. Language on test report French English 2 Spanish

MS Relais SAS AG 400 relay-v.2 Nov 20 Tour Rosny 2, Avenue du Général de Gaulle, F - 938 Rosny-sous-Bois Cedex, FRANCE T +33 (0) 482 440, F +33 (0) 48 900 E sales@msrelais.com Mors Smitt Asia Ltd. # 807, Billion Trade Centre, 3 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +82 2343, F +82 2343 6 E info@morssmitt.hk Nieaf-Smitt B.V. Vrieslantlaan 6, 326 AA Utrecht, NETHERLANDS T +3 (0)30 288 3, F +3 (0)30 289 886 E sales@nieaf-smitt.nl Mors Smitt Technologies Inc. 420 Sackett Point Road North Haven, CT 06473, USA T + (203) 287 888, F + (888) 287 882 E mstechnologies@msrelais.com Mors Smitt UK Ltd. Doulton Road, Cradley Heath West Midlands, B64 QB, UK T +44 (0)384 67 7, F +44 (0)384 67 70 E info@morssmitt.co.uk (c) Copyright 20 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract.