LED Utility Wrap Fixture

Similar documents
LED Recessed Troffer Retrofit Kit

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

USE AND CARE GUIDE 4 FT. LED WRAP LIGHT

Use and Care Guide. Part # UC SV-D Model # UC SV-d UC SV-d

MaxLite LED UTILITY WRAP FIXTURES

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

MaxLite StaxMax LED Flood Lights

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

LED FLUSHMOUNT CEILING FIXTURES

Lumination TM LED Luminaire LUR Series

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Use and Care Guide. Item #

Use and Care Guide.

HBC-20 - LED HIGH BAY

Use and Care Guide. Item #

MAXLITE RKT LED Retrofit Kit

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Motion and Light Sensor Kit LHBAS51

When using electrical equipment, basic safety precautions should always be followed including the following:

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Wireless Dimmer Installation and User Guide

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

Installation and Operation Instructions 10/04/13

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

MOTION-ACTIVATED WALL LANTERN

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Solid State T8 tube is the smart alternative to a

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

LED Warehouse Industrial Lighting - 2 Ft Compact High Bay SPEC SHEET

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

INSTALLATION INSTRUCTIONS

TC26-B Vehicle Sensor

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

HANGING LANTERN ITEM # MODEL #CP199MBK. Français p. 9. Español p. 17 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

LT Charging Cart for Laptops

Model: LUM-P1-40WCDS LUM-P7-50WCDS

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

SET-LED-KIT. Specifications. Entablature Small, PicoEmitter LED Upgrade Kit. Type: Job: Catalog number: Approvals: Date: Page: 1 of 5

User Guide. Model No.: GDI-GFD7200

SL2282 LED Clipper Ceiling Light 180MM 11W SURFACE MOUNTED LED DOWNLIGHTS

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Instruction/Installation Manual

High Bay Luminaire Series

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

BroadBand PowerShield. 20 AHr Battery. User Manual

Installation Instructions: Eco Linear High Bay

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

ECO-T LED RECESSED TROFFER USER MANUAL

TECTONIC LED CORP. ISO

LED FLUSHMOUNT CEILING FIXTURES (SET OF 4)

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.

ASSEMBLY AND INSTALLATION INSTRUCTIONS

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Universal Retrofit System Installation Instructions Revised:

F5 Platforms: FIPS Kit Installation MAN

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P


Cruising Charger Series OWNER S MANUAL

EMERY SKY SUSPENDED LED LUMINAIRE

LED SEMI-FLUSHMOUNT CEILING FIXTURE

Neptune X6 12/24V SAE 316L Stainless Steel Low Profile Through-Hull Mounted Underwater LED Light Manual

Luminaires - LED High Bay

LED Vapor Tight For Tough Environments

Linear Line Voltage LED Engine

LED SMD CANOPY FLAT FIXTURE

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

VERSA TOUCH 2 INSTALLATION VERSA TOUCH 2 CONTROL BRACKET INSTALLATION

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

MaxLite LED Linear HighBay Fixtures

INSTALLATION NOTES: nbeckon-26

Operator Manual For use with WFCO ULTRA III Power Center WF-9900 Series (model number located on the door assembly label)

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

HBDBM High Bay Series

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

AutoLabeler. User s Guide A (3/02).01

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Digital Clock model 75100C

LED CANOPY with j-box

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Denali Fairbanks Yukon

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Radio-Control Raceway

CAUTION: Read manual carefully for proper procedures and operation.

SECTION ELECTRICAL DESIGN AND CONSTRUCTION STANDARDS _ February A. Use heavy duty type fused and non-fused, enclosed switches only.

HAZARDOUS LOCATION STREET LIGHT SLA SERIES INSTALLATION INSTRUCTIONS

OWNER S MANUAL Please read and understand all precautions prior to use.

UL AND CODE COMPLIANCE

(Equipped with Bottle Jack)

USE AND CARE GUIDE 7000 LUMEN TWIN HEAD LED WORKLIGHT WITH TRIPOD

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

Transcription:

Operating Instruction Please read and save these instructions. Read through this owner s manual carefully before using product. Protect yourself and others by observing all safety information, warnings, and cautions. Failure to comply with instructions could result in personal injury and/or damage to product or property. Please retain instructions for future reference. Description LumaPro features a full length Wrap Acrylic lens and a one-piece fabricated steel body. Designed to meet up to ten foot candles at 8 installed heights for parking drive lane compliance, the fixtures are ideal for utility lighting in parking garages and stairwells, meeting applicable building and safety codes. Can be wall or ceiling mounted and is suitable for damp locations. 30UH63 thru 30UH70 30UH71 thru 30UH78 CONSTRUCTION 20 Ga. steel body and end caps Clear acrylic prismatic lens Electrostatic paint pre-assembly Specifications and Dimensions Dimensions (in) Model Volts Watts Lumens CCT CRI Dimmable L x W x H 30UH63 120/277V 20W 1524 4100K 85 NO 24-13/16 x 6-5/8 x 2-3/8 30UH64 120/277V 20W 1646 5000K 87 NO 24-13/16 x 6-5/8 x 2-3/8 30UH65 120/277V 20W 1524 4100K 85 YES 24-13/16 x 6-5/8 x 2-3/8 30UH66 120/277V 20W 1646 5000K 87 YES 24-13/16 x 6-5/8 x 2-3/8 30UH67 120/277V 28W 2347 4100K 84 NO 24-13/16 x 6-5/8 x 2-3/8 30UH68 120/277V 28W 2044 5000K 85 NO 24-13/16 x 6-5/8 x 2-3/8 30UH69 120/277V 28W 2347 4100K 84 YES 24-13/16 x 6-5/8 x 2-3/8 30UH70 120/277V 28W 2044 5000K 85 YES 24-13/16 x 6-5/8 x 2-3/8 30UH71 120/277V 35W 2814 4100K 85 NO 48-5/8 x 6-5/8 x 2-3/8 30UH72 120/277V 35W 2841 5000K 86 NO 48-5/8 x 6-5/8 x 2-3/8 30UH73 120/277V 35W 2814 4100K 85 YES 48-5/8 x 6-5/8 x 2-3/8 30UH74 120/277V 35W 2841 5000K 86 YES 48-5/8 x 6-5/8 x 2-3/8 30UH75 120/277V 45W 3711 4100K 86 NO 48-5/8 x 6-5/8 x 2-3/8 30UH76 120/277V 45W 3689 5000K 87 NO 48-5/8 x 6-5/8 x 2-3/8 30UH77 120/277V 45W 3711 4100K 86 YES 48-5/8 x 6-5/8 x 2-3/8 30UH78 120/277V 45W 3689 5000K 87 YES 48-5/8 x 6-5/8 x 2-3/8 Manufactured for Grainger International, Inc. Printed in USA 04/14 Form# LT-2174

General Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 1. Review the diagrams thoroughly before beginning 2. Two people recommended for installation. 3. All electrical connections must be in accordance with local codes, ordinance, and the National Electric Code. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified licensed electrician. 4. Before starting the installation, disconnect the power by turning off the circuit breaker or by removing the appropriate fuse at the fuse box. Turning the power off using the light switch is not sufficient to prevent electrical shock. 5. Equipment should be mounted in locations and at heights where it will not readily be subject to tampering by unauthorized personnel. 6. Do not use this equipment for other than intended use. 7. All servicing should be performed by qualified personnel. - Risk of fire or electric shock. Installation requires knowledge of the lighting luminaires electrical systems. If not qualified, do not attempt installation and contact a qualified electrician. - Risk of injury or property damage. - Do not make or alter any open holes in an enclosure of wiring or electrical components during installation Wiring Diagram All units must be individually connected to the AC supply: Purple Gray (Connecting driver to AC source supply: Operating Temp: -4 F to 104 F Degrees **Consult with dimmer control manufacturer s wiring instructions 2 ** 0-10v IEC Dimming Control wires

1. Black = Line White = Neutral Green = Ground 2. Line connection to be made to switch lead from source. Installation Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply 1. Remove lens and wire way cover. Pull back on edge of fixture as indicated and remove lens. 2. Remove screw from center wirer cover. 3. Next squeeze both sides of wire cover until they clear metal tabs and remove cover. *Pull back on end cap to releases lens 4. Select wiring access point and remove appropriate knock. 5. Select installation point and locate studs 3

6. For rear access points feed wires through hole 7. Using 1 mounting screw or 3 x3/16 toggle bolts secure fixture in place. 4

Exploded View Lens Cover Warranty LIMITED FIVE YEAR WARRANTY Should this product fail to perform satisfactorily due to a defect or poor workmanship within FIVE YEAR from the date of purchase, return it to the place of purchase and it will be replaced, free of charge. Incidental or consequential damages are excluded from this warranty. Manufactured for Grainger International, Inc. 5 100 Grainger Pkwy., Lake Forest IL 60045 U.S.A.

Labeling: 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 6