Battery Monitoring System

Similar documents
Power Conversion. Battery Chargers. Model

Power Conversion. Battery Chargers. Model

Power Conversion. Battery Chargers. Model

CAN and Serial Instrumentation

Power Conversion. Battery Chargers. Model

Industrial Power Supplies

3 Uninterruptible Power Systems

CBI All in One DC UPS Power Solutions

Industrial Chargers and

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

AC Induction Motor Controller with VCL

AC/DC Converter MBP250-2A13D13M

Indoor Linear 50W Driver SI-CU WW

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

MCD 200 Series Soft Starters

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

ID ID. Series 19. Mechanical Products Company

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Switching Power Supplies

Digital Instrumentation Model 3501

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Uninterruptible Power Systems

TPM. w w w. n a v i t a s t e c h n o l o g i e s. c o m

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

INTERNATIONAL METAL ENGINEERING

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

POWERTRONIX QUASAR 5-40 KVA

PowerMASTER M-frame GENERAL SPECIFICATIONS. DC connection. AC connection. Liquid cooled heavy duty inverter PRODUCT DATA. Visedo PowerMASTER features:

EM DC Multi-Function DC Energy Meter

ABB central inverters ULTRA-750/1100/ kW to 1560kW

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Separately Excited Electronic Motor Speed Controller Model 1243 SepEx

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Liquid cooled heavy duty converter

3 Uninterruptible Power Systems

PQdynaC High speed, flexibility and modularity

AT30 SERIES BATTERY CHARGER

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual

PQstorI One stop solution for energy storage and power quality

Three Phase UPS Systems Range: 10 to 500kVA

Aurora Single Phase Emergency Lighting Inverters

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

1.1 GENERAL CHARACTERISTICS

Low Profile DC Power Supply with Zero Voltage Soft Switching

XTRA-N SERIES. New MPPT Solar Charge Controller. Product models XTRA1206N/XTRA2206N XTRA1210N/XTRA2210N XTRA3210N/XTRA4210N.

D R C- 4 0 s e r i e s

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

CX Series User s Manual

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

HUMIDITY / TEMPERATURE TRANSMITTER

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l

PowerValue 11/31 T kva

EVO Series APPLICATIONS BATTERY TYPE CHARGING TIME TECHNICAL FEATURES SAFETY FEATURES GENERAL FEATURES ACCESSORIES. PzS Wet (Lead Acid)

Uninterruptible Power Systems

RWS50B RWS100B RWS150B RWS300B RWS600B

EPS/ELA-Series User Manual EPS/ELA 250W

CX-SERIES ADVANCED BATTERY CHARGER

DIGITAX ST UNIMOTOR 2000RPM COMBINATIONS

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Features : 3 years warranty PB PB PB V 28.8V 57.6V 13.8V 86% 87% 89%

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Permanent Magnet Motor Speed Controller 1212S / 1212P / 1212C

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

GENERAL SPECIFICATIONS

Master DIALOG INDUSTRY RANGE

3 Uninterruptible Power Systems

Liebert. PSI & PSI-XR 750VA - 3kVA & 1kVA-3kVA High Performance Power Protection for Servers and Networking Equipment

Onfiniti. 1 Phase UPS

3 Uninterruptible Power Systems

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Synthesis Twin. from 6 to 20 kva

Technical Data Sheets

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

All In one uninterruptible power supply solutions

Transcription:

Instrumentation Battery Monitoring System www.curtisinstruments.com 1

The Curtis Acuity Battery Monitoring System is a device that mounts directly to an industrial vehicle lead acid battery. It measures, records and transmits battery performance data throughout the battery s life. Curtis Acuity is ideal for use in electric vehicles for material handling, airport ground support, floor cleaning, light-on-road, golf/utility and aerial work platforms. See the Acuity Battery Monitoring System in action at: curtisinstruments.com/360view FEATURES Highly accurate State-of-Charge calculation that uses battery voltage, current, temperature and time to maximize vehicle up-time. Acuity provides the data to determine if the battery has been operated within the conditions of its warranty. Because Acuity is permanently attached to the battery, information is collected consistently and accurately no matter when or how often the battery is moved, without interruption. The data from Acuity allows the optimization of a battery fleet to ensure that vehicle productivity is maximized. Acuity data is communicated via CANbus, which allows easy integration with Curtis engage displays, motor controllers and hand-held programmers. CANbus isolation eliminates ground loops that can cause component damage as well as data errors due to differences in ground potentials among the nodes on the CANbus. Installation of Acuity is simple and non-invasive to minimize cost and the need for special hardware. No cutting of cables or drilling into the battery. Integral Real-Time-Clock allows date and time stamping of significant events related to the battery or any vehicle component on the CANbus. By measuring, recording and communicating battery current, voltage, temperature and use-time, Acuity can compensate for the effects of variations in load, duty cycle and operating temperature of any given application. Acuity calculates the Percent of Rated Capacity remaining in the battery as an indication of remaining battery life. Curtis Acu-Set software, when installed on a computer that is connected to an Acuity via a CAN-to-USB dongle, allows: Acuity to be configured to match the specific battery on which it is mounted. Historical data from Acuity to be uploaded a PC. Instantaneous battery performance data to be viewed on a PC (Power Prover mode). Recording of battery data for a user-specified period of time or specific vehicle operation. Fleet Management Software CAN wifi CANbus www.curtisinstruments.com 2

SPECIFICATIONS Electrical Operating Voltage Range 2448D = 18 to 60 VDC 72140D = 60 to 180 VDC Isolation 500 VAC per UL 583 Shock UL 583 Transients IEC 6100-4-4, test level 2 Reverse Voltage Protection Acuity will not be damaged if connected to the battery with inverted polarity. Short Circuit Protection All inputs and outputs (except CANbus) shall withstand continuous short circuit to negative (B ) or positive (B+) voltage. CANbus Isolation Eliminates ground loops that can cause component damage as well as data errors due to differences in ground potentials among the nodes on the CANbus. Environmental Operating & Storage Temperature Range 30 to +55 C Humidity 100% condensing per IEC 60068-2-30, Db Environmental con t Protection IP67 per EN60529 Vibration IEC 60068-2-6, Fc Shock IEC 60068-2-29, Eb Chemical Resistance Immune to the effects of contact with battery electrolyte, hydraulic fluid, water, baking soda. EMC Specifications Emissions EN55022 Class B (Component Test) Immunity EN61000-4-3 (Component Test) ESD EN61000-4-2 (Component Test) Regulatory Approvals UL (Pending) Recognition or component listing (UL583) www.curtisinstruments.com 3

DIMENSIONS mm 47 26 54 SEE NOTE 2 CURRENT SENSOR Arrow shows direction of discharge current 940±15 44 ALLOWABLE MENISCUS 3mm MAX 179 30 125±15 605±15 NOTES: 1. Case & Current Sensor Housing Material: Glass-filled PBT. 2. Current Sensor can accomodate most cable sizes up to 4/0. 3. Current Sensor to be held to battery cable by tie-wraps (2 places). 4. Acid resistant tie-wraps should be used to secure unit. 5. This unit not fitted with a CAN termination resistor. 960±15 POWER CABLES B+ : Red B : Black CAN CONNECTOR Pin 1 & Pin 2 TEMP SENSOR CABLE 5/16" RING TERMINALS TYP 3X www.curtisinstruments.com 4

INFORMATION READOUT Battery ID State of Charge Historical Plot 100% 90% Select Parameter To Plot The Acu-Set software translates the Acuity battery data into easy-to-read performance data. It also calculates Percent Rated Capacity (PRC) the actual energy the battery can deliver as compared to its rated capacity. 80% 70% 60% 50% 40% 30% 20% 10% 0% 1 21 41 61 81 101 Historical Record Number Battery Cycles High Temperature Events Low Temperature Events 90% 40% State Of Change Temperature Ah Percent Ah Returned Ah Capacity Battery information is displayed in real time on the Curtis engage VII or any other CAN-based display. WARRANTY Two year limited warranty from time of delivery. is a trademark of Curtis Instruments, Inc. Specifications subject to change without notice 2016 Curtis Instruments, Inc. 50214 Rev C 3/16 www.curtisinstruments.com 5