Powerful centrifugal fans for universal use: The product ranges TEM and REM

Similar documents
Powerful centrifugal fans for universal use: The product ranges TEM and REM

Centrifugal Fans RZR belt driven. Issue 2.5 EN August 2013

Centrifugal Fans ADH belt driven. Issue 2.5 EN August 2013

VORTICENT C E RANGE Centrifugal fans

RLM EVO High Performance - Plug Fans Impeller with true airfoil blades

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Small centrifugal fans made of plastic

Centrifugal fan with highly efficient EC drive motor

Axial Flow Fans. Issue 6.

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

FEATURES & BENEFITS UPON REQUEST

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

AXIAL FANS Catalogue CN0050C01 May 2008

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

Centrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

ROOFMASTER STEF-ATEX ROOF FAN

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

Company name: Created by: Phone:

Centrifugal medium-pressure fans fitted with multi-blade

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

Company name: Created by: Phone:

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

CGT Series Adjustable Pitch Fans

Sabre Plate Mounted Sickle Fans (VSP)

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

MTB /183 A-F-A-BQQV 400D-2 11kW

CHMT Series, F Rated Fans

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER

Unobox units with backward curved centrifugal impellers

CGT Series Adjustable Pitch Fans

RLM EVO High Performance - Plug Fans Impeller with true airfoil blades. Issue 1 June 2011

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

Section 4. Axial Fans - Section 4

A Smarter Breed. of Centrifugal Fans

CRN A-F-G-V-HQQV 30kW 3x400D 50Hz

FAN & BLOWER CENTRIFUGAL FANS

For ATEX zone 1/1, 22/22 and 21/21. Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h

Pneumatic Axial Fan Type Tech. Doc. No. 802

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

CR A-F-A-V-HBQV 3x400/ HZ

CM5-11 A-R-G-E-AQQE F-A-A-N

CR45-10 A-F-A-E-HQQE 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CR A-F-A-V-HQQV 3x400/ HZ

F a n t y p e s J K K - J K K

AATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES:

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

VALIADIS S.A. HELLENIC MOTORS

RLM EVO High Performance Plug Fans Impeller with true airfoil blades. Issue 1.4 EN June 2012

ROOFMASTER STEF-HT ROOF FAN

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

NB /438 A-F1-A-GQQE

Hison Axial Flow Fans

CR A-F-A-E-HQQE 3x400/ HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

MTB /158 A-F-A-BQQV 400D-2 5,5kW

TP /2-A-F-A-BAQE 400D 50HZ

CYLINDRICAL CASED AXIAL FLOW FANS

BPF. Centrifugal Plug Fans

Hison Axial Flow Fans

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CM10-3 A-R-A-E-AVBE F-A-A-N

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

SERIES R - MD MOR & GOR

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Size and Configurations

ROOF FAN ROOFMASTER STEC

NK40-160/172A1F2AE-SBAQE

CRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRN120-3 A-F-G-V-HQQV 3x400/ HZ

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CM10-3 A-R-G-V-AQQV F-A-A-N

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

AXIAL FANS Axis / Tubo OPERATION MANUAL

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

TP /2-A-F-A-BQQE 400D 50HZ

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

Transcription:

Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which are universally usable for many ventilation purposes either in HVAC or in machinery design industry and heavy duty installation business. The fans are available with forward curved impellers (TEM) or with impellers (REM) equipped with backward curved blades. The fans are equipped with IEC flanged (B5) standard s, protection IP55, class F, and they are suitable for frequency inverter controlled operation. Benefits: compact design because of direct drive cost effective by maintenance-free operation speed controlled by frequency inverter universally usable due to different options, such as without brackets as a directly fitted unit for operation with vertical shaft arrangement with brackets for operation with horizontal shaft ATEX execution for explosion hazardous areas and applications Fan range TEM rated - Ex II 3G c IIB T3 Fan range REM rated - Ex II 2G c IIB T3 264

Nicotra Gebhardt TEM and REM The universal technology for various applications! TEM ranges Sizes from 16 up to 355 Volume up to 9 also available in 6Hz execution also available in ATEX execution 3G with PTC in flange execution Impeller with forward curved blades For applications in HVAC-facilities, big kitchen or for clean room technologie. REM ranges Sizes from 2 up to 63 Volume up to 2, also in available 6Hz execution also available in ATEX execution 2G with PTC in flange execution Impeller with backward curved blades For applications in the filter technologie, drying- and suction plants. The ranges TEM and REM For every application, the suitable fan: Version Description Figure TEM 1-16/-355 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with forward curved blades, without pedestal, for vertical or horizontal mounting. TEM 8-16/-355 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with forward curved blades, with pedestal, for horizontal mounting. REM 11-2/-63 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with backward curved aerofoil blades, without pedestal, for vertical or horizontal mounting. REM 18-2/-63 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with backward curved aerofoil blades, with pedestal, for horizontal mounting. REM 13-2/-63 Scroll casing stitch welded with discharge flange, epoxy coated, built-in impeller with backward curved aerofoil blades, without pedestal, for vertical or horizontal mounting. REM 19-2/-63 Scroll casing stitch welded with discharge flange, epoxy coated, built-in impeller with backward curved aerofoil blades, with pedestal, for horizontal mounting. REM 41-2/-45 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with backward curved blades, without pedestal, for vertical or horizontal mounting. REM 48-2/-45 Lap jointed scroll of galvanised sheet steel with discharge flange and built-in impeller with backward curved blades, with pedestal, for horizontal mounting. 265

Description Direct driven centrifugal fans / TEM/REM / Description Safety Performance data The fans are designed for installation in equipment and as standard are not equipped with protective guards. They should not be put into operation before all protective devices are fitted and connected! Protective measures must be carried out as set out in DIN EN ISO 121 "Safety of machinery - Basic concepts, general principles for design". If the application of the fan allows free access to the inlet and discharge apertures, safety devices must be put in place on the fan in accordance with DIN EN ISO 13857! Suitable safety guards are available as an optional extra. The performance curves of the fans are determined at the plenum test rig according to ISO 581, measured in installation "B". In the diagrams of all series, the total pressure increase and the dynamic pressure in relation to the flange crosssection at the discharge are represented in dependency on the. For closer determination of duty same unit performance curves (parabolas) are contained in the diagrams. The static pressure increase p sf with a connected discharge flange can be determined according to the following relation. p sf = All data are valid for the source density r 1 = 1,2kg/m³. Sound The noise measuring and evaluation is conducted according to DIN 45635-38 Noise measurement in machines: fans. In the diagrams the A-weighted sound power level of the fan is given on the performance curves as the emission. The A weighted sound power level are identical for fan intake (7 ) as well as for fan discharge (4 ). The A-weighted sound pressure level L pa7/6 at a distance of 1 m at fan Inlet or discharge can be approximately determined by the following formula: L pa6/7 ~ 4/7-7dB The sound power levels in the individual octavos can be taken from the electronic catalogue proselecta II. s Electric connection The series of centrifugal fans, with single inlet are designed for the use in air handling and ventilation installations. The fans are suitable for conveying air and other non aggressive gases. The temperatures admitted for the fluid are from -2 C to +6 C. Standard s of wellknown brands, type of protection IP55, thermal class F, are used. During commissioning and maintenance the detailed instructions provided by the manufacturer (type plate/ operating instructions) must be followed, this also applies to the protection devices required onsite. The s are equipped with PTC resistors/temperature sensors as standard. s with integrated frequency inverters may be supplied on request. The centrifugal fans are delivered ready for installation. The terminal box can be accessed easily. Electric installation must be carried out according to the applicable provisions in compliance with local regulations. A terminal board circuit diagram showing correct connection is enclosed with every. Updated circuit diagrams are also available online at www.nicotra-gebhardt.com. In case of operation with frequency inverters, always follow the respective operating instructions! 328

Description Direct driven centrifugal fans / TEM/REM / Description Explosion protection according to ATEX Fans for use in explosive atmospheres must comply with EC Directive 94/9/EG (ATEX 95). Equipment in Group II (all applications except mining) is categorised in accordance with the required degree of safety for designated use in equipment categories 1, 2 and 3. Depending on suitability, a distinction is in addition made between G (gas, vapours) and D (dust). Harmonised European standards and national guidelines must be observed. Equipment in class 2 and 3 is not subject to compulsory specifications nor to type testing. The manufacturer declares conformity with the EC directive. For the standard designs of our fans, the following ignition sources are essentially to be considered: Hot surfaces, e.g. due to heat of friction or seizure of a bearing or due to blockage of an impeller Rubbing-, grinding- or beating sparks, e. g. as a result of contact of the impeller with stationary components Sparks resulting from discharge of electrostatically loaded, non-conducting omponents, e. g. of plasticpanels, surfaces with strong layer thickness. Preconditions for operating: In the proximity of the, the temperature limits -2 C and +4 C must not be exceeded. The temperature limits of -2 C und +6 C for the medium must not be exceeded. If the temperature of the medium should exceed +6 C on the pressure side, then the fan must be switched off! The fans may only be employed with a horizontal shaft. The fans are to be protected against the falling-in or sucking-in of foreign objects. Protection guards must be ordered separately as an accessories. On the machine plate the max. permitted fan speed is indicated. Fans for operation in ex-hazardous areas are marked as such on the machine plate and they are accompanied by an EU conformity declaration and with operation and maintenance instructions The operation and maintenance instructions have strictly to be observed. 329

REM 1-2 Direct driven centrifugal fans / REM / 6 5 72 db 72 REM 1.-2-2D-7 REM 1.-2-2X-7-2G 4 V 5 Hz [A1/A2] 8 76 db REM 1.-2-2D-7-6 46 V 6 Hz 76 [A3] 4 74 6 78 3 76 4 8 2 1 77 2 81 2 4 6 8 1 12 2 4 6 8 1 12 14 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 282

REM 1-2 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 2-2D-7 [A1].37 2 71 23/4 5 D/Y 1.73/1. 274 6 129 1/12/14/16 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 2-2X-7-2G [A2].37 2 71 23/4 5 D/Y 1.61/.93 2825 6 129 1/12/14/16 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 2-2D-7-6 [A3].43 2 71 46 6 Y 1. 3288 6 152 1/12/14/16 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-2 REM 13-2 84+k2 Ø7 188 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 134 67 6 M6 1 9 127 161 181 2 9 253 157 89 286 36 399 242 168 356 LG RD REM 18-2 REM 19-2 181 Ø7 161 356 188 168 127 6 Ø7. 84+k2 1 9 2 9 253 286 36 Ø25 Ø235 Ø255 89 242 489 256 131 67 77 6 M6 13 25 247 13 25 329 354 13 218 ZSG ZKE 11 ZKF 11 Ø1 312 ZKE 16 ZKF 16 415 247 489 247 297 454 415 247 LG LG 9 LG 27 RD 247 489 RD 9 RD 27 297 454 283

REM 1-225 Direct driven centrifugal fans / REM / 8 7 6 5 4 3 2 1 74 db REM 1.-225-2D-7 REM 1.-225-2X-7-2G 4 V 5 Hz 4 8 12 16 75 [B1/B2] 77 79 81 12 1 8 6 4 2 78 db 79 [B3] REM 1.-225-2D-7-6 46 V 6 Hz 5 1 15 2 81 84 85 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 284

REM 1-225 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 225-2D-7 [B1].37 2 71 23/4 5 D/Y 1.73/1. 274 6 188 11/13/16/18 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 225-2X-7-2G [B2].37 2 71 23/4 5 D/Y 1.61/.93 2825 6 188 11/13/16/18 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 225-2D-7-6 [B3].43 2 71 46 6 Y 1. 3288 6 217 11/13/16/18 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-225 REM 13-225 89+k2 Ø1 21 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 149 74 6 M6 1 1 142 18 26 2 1 285 176 1 322 348 45 274 191 41 LG RD REM 18-225 REM 19-225 26 Ø1 18 41 21 191 142 6 Ø7. 89+k2 1 1 2 1 285 322 348 Ø229 Ø259 Ø279 1 274 74 85 6 M6 13 25 13 3 363 388 13 32 ZSG ZKE 11 ZKF 11 Ø1 376 ZKE 16 ZKF 16 549 358 38 582 358 534 582 38 549 358 38 582 288 146 358 534 LG LG 9 LG 27 RD RD 9 RD 27 285

REM 1-25 Direct driven centrifugal fans / REM / 1 8 6 78 db REM 1.-25-2D-8 REM 1.-25-2X-8-2G 4 V 5 Hz 78 [C1/C2] 8 14 12 1 8 83 db 83 REM 1.-25-2D-1-6 46 V 6 Hz 85 [C3] 4 83 6 88 2 84 4 2 89 5 1 15 2 5 1 15 2 25 3 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 286

REM 1-25 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 25-2D-8 [C1].55 2 71 23/4 5 D/Y 2.35/1.36 28 6 255 15/17/21/23 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 25-2X-8-2G [C2].55 2 71 23/4 5 D/Y 2.42/1.4 2785 6 255 15/17/21/23 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 25-2D-1-6 [C3].86 2 8 46 6 Y 1.73 3426 6 38 17/2/24/26 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-25 REM 13-25 98+k2 Ø1 231 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 167 83 6 M6 1 1 16 198 224 3 1 319 194 19 356 382 494 3 26 437 LG RD REM 18-25 REM 19-25 Ø1 224 198 231 437 26 16 6 Ø7. 98+k2 1 1 Ø256 Ø286 Ø36 19 3 68 322 164 83 88 6 M6 13 25 38 32 ZSG ZKE 11 ZKF 11 Ø1 376 ZKE 16 ZKF 16 68 13 3 363 388 13 514 38 38 358 552 68 38 514 38 358 552 3 1 319 356 382 LG LG 9 LG 27 RD RD 9 RD 27 287

REM 1-28 Direct driven centrifugal fans / REM / 12 82 db REM 1.-28-2D-11 REM 1.-28-2X-11-2G 4 V 5 Hz 16 86 db REM 1.-28-2D-11-6 46 V 6 Hz 1 8 82 [D1/D2] 84 12 86 [D3] 88 6 87 8 91 4 2 89 4 93 5 1 15 2 25 3 35 5 1 15 2 25 3 35 4 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 288

REM 1-28 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 28-2D-11 [D1] 1.1 2 8 23/4 5 D/Y 4.25/2.45 2845 6 376 18/21/26/29 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 28-2X-11-2G [D2] 1.1 2 8 23/4 5 D/Y 4.33/2.5 2855 6 376 18/21/26/29 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 28-2D-11-6 [D3] 1.3 2 8 46 6 Y 2.41 3435 6 447 18/21/26/29 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-28 REM 13-28 113+k2 Ø1 258 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 187 93 8 M8 1 1 179 217 243 3 1 358 216 122 395 421 549 333 226 484 LG RD REM 18-28 REM 19-28 Ø1 243 217 258 484 226 179 8 Ø9.5 113+k2 1 1 3 1 358 395 421 Ø288 Ø322 Ø348 122 333 651 361 183 93 11 8 M8 13 3 318 32 ZSG ZKE 11 ZKF 11 Ø1 446 ZKE 16 ZKF 16 651 13 3 435 46 13 544 318 318 368 584 651 318 544 318 368 584 LG LG 9 LG 27 RD RD 9 RD 27 289

REM 1-315 Direct driven centrifugal fans / REM / 16 85 db REM 1.-315-2D-13 REM 1.-315-2X-14-2G 4 V 5 Hz 25 REM 1.-315-2D-14-6 46 V 6 Hz 12 8 86 [E1/E3] 87 89 2 15 1 9 db 91 [E5] 92 94 4 9 5 95 1 2 3 4 5 1 2 3 4 5 6 4 67 db REM 1.-315-4D-7 REM 1.-315-4X-7-2G 4 V 5 Hz 6 REM 1.-315-4D-7-6 46 V 6 Hz 3 2 68 [E2/E4] 69 71 4 71 db 72 [E6] 73 1 72 2 75 76 5 1 15 2 25 5 1 15 2 25 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 29

REM 1-315 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 315-2D-13 [E1] 1.5 2 9 S 23/4 5 D/Y 5.7/3.3 286 6 525 25/28/33/36 315-4D-7 [E2].25 4 71 23/4 5 D/Y 1.32/.76 135 6 26 19/22/26/29 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 315-2X-14-2G [E3] 1.85 2 9 L 23/4 5 D/Y 6.85/3.95 286 6 525 28/31/36/39 315-4X-7-2G [E4].25 4 71 23/4 5 D/Y 1.39/.8 131 6 26 19/22/26/29 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 315-2D-14-6 [E5] 2.55 2 9 L 46 6 Y 4.6 348 6 636 28/31/36/39 315-4D-7-6 [E6].29 4 71 46 6 Y.76 162 6 3 19/22/14/29 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-315 REM 13-315 118+k2 Ø1 29 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 29 14 8 M8 1 1 21 239 265 3 1 41 242 139 438 464 613 371 247 537 LG RD REM 18-315 REM 19-315 Ø1 265 239 29 537 247 21 8 Ø9.5 118+k2 1 1 3 1 41 438 464 Ø322 Ø356 Ø382 139 371 723 44 25 14 9 8 M8 13 3 352 32 ZSG ZKE 11 ZKF 11 Ø1 446 ZKE 16 ZKF 16 723 13 3 435 46 13 599 352 352 429 671 723 352 599 352 429 671 LG LG 9 LG 27 RD RD 9 RD 27 291

REM 1-355 Direct driven centrifugal fans / REM / 2 15 88 db REM 1.-355-2D-16 REM 1.-355-2X-19-2G 4 V 5 Hz 89 [F1/F3] 9 3 25 2 93 db 94 REM 1.-355-2D-19-6 46 V 6 Hz [F5] 95 1 92 15 97 5 95 1 5 1 1 2 3 4 5 6 7 2 4 6 8 5 4 3 2 7 db 71 REM 1.-355-4D-8 REM 1.-355-4X-8-2G 4 V 5 Hz [F2/F4] 72 75 8 6 4 75 db REM 1.-355-4D-1-6 46 V 6 Hz 76 [F6] 77 8 1 77 2 82 5 1 15 2 25 3 35 5 1 15 2 25 3 35 4 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 292

REM 1-355 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 355-2D-16 [F1] 3. 2 1 L 23/4 5 D/Y 1.6/6.1 2835 6 777 34/39/43/48 355-4D-8 [F2].37 4 71 23/4 5 D/Y 1.78/1.3 137 6 378 23/28/32/37 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 355-2X-19-2G [F3] 3.3 2 112 M 23/4 5 D/Y 11.6/6.7 2875 6 777 53/58/62/67 355-4X-8-2G [F4].37 4 71 23/4 5 D/Y 1.91/1.1 1355 6 378 23/28/32/37 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 355-2D-19-6 [F5] 4.6 2 112 M 46 6 D 7.6 352 6 945 39/44/48/53 355-4D-1-6 [F6].63 4 8 46 6 Y 1.45 1674 6 459 26/31/16/4 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-355 REM 13-355 13+k2 Ø1 325 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 234 116 8 M8 2 1 225 263 289 4 1 449 272 157 487 513 686 414 273 598 LG RD REM 18-355 REM 19-355 Ø1 289 263 325 598 273 225 8 Ø9.5 13+k2 2 1 4 1 449 487 513 Ø361 Ø395 Ø421 157 414 846 453 229 116 139 8 M8 13 3 432 32 ZSG ZKE 11 ZKF 11 Ø1 446 ZKE 16 ZKF 16 846 13 3 545 57 13 75 432 432 5 772 846 432 75 432 5 772 LG LG 9 LG 27 RD RD 9 RD 27 293

REM 1-4 Direct driven centrifugal fans / REM / 25 2 15 91 db 92 REM 1.-4-2D-21 REM 1.-4-2X-22-2G 4 V 5 Hz [G1/G3] 94 96 4 3 2 96 db 97 REM 1.-4-2D-22-6 46 V 6 Hz [G5] 99 11 1 5 99 1 14 2 4 6 8 1 2 4 6 8 1 12 6 5 4 3 2 72 db 73 REM 1.-4-4D-1 REM 1.-4-4X-11-2G 4 V 5 Hz [G2/G4] 75 77 8 1 8 6 4 77 db 78 REM 1.-4-4D-13-6 46 V 6 Hz [G6] 8 82 85 1 2 1 2 3 4 5 1 2 3 4 5 6 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 294

REM 1-4 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 4-2D-21 [G1] 5.5 2 132 S 4/69 5 D/Y 1.6/6.14 295 6 1132 /77/ / 4-4D-1 [G2].55 4 8 23/4 5 D/Y 2.5/1.45 1395 6 537 29/32/6/63 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 4-2X-22-2G [G3] 5.5 2 132 S 4/69 5 D/Y 1.7/6.2 292 6 1132 /84/ / 4-4X-11-2G [G4].75 4 8 23/4 5 D/Y 3.55/2.5 1375 6 537 29/32/6/64 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 4-2D-22-6 [G5] 8.6 2 132 S 46 6 D 14. 351 6 136 /78/ / 4-4D-13-6 [G6] 1.3 4 9 S 46 6 Y 2.65 171 6 67 33/36/64/67 For "REM..-4-2D-21", "..-2X-22-2G" and "..-2D-22-6" only model "13-" available! protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-4 REM 13-4 134+k2 Ø1 369 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 329 13 6 M8 4 1 54 541 567 2 1 252 29 316 639 27 34 179 767 463 27 32 671 LG RD REM 18-4 REM 19-4 316 29 Ød1 365 32 27 463 34 179 27 252 6 Ø9.5 134+k2 Ø1 7 2 1 13 297 329 4 1 54 541 567 82 6 M8 Ø44 Ø438 Ø464 13 3 775 7 4 54 179 463 31 57 256 13 3 671 369 32 27 7 4 54 639 ZSG ZKE 11 ZKF 11 ZBG ZKE 16 ZKF 16 LG LG 9 LG 18 LG 27 RD RD 9 RD 18 RD 27 295

REM 1-45 Direct driven centrifugal fans / REM / 8 7 6 5 75 db 76 REM 1.-45-4D-13 REM 1.-45-4X-13-2G 4 V 5 Hz [H1/H2] 78 12 1 8 8 db 81 REM 1.-45-4D-14-6 46 V 6 Hz 83 [H3] 4 81 6 86 3 2 84 4 89 1 2 1 2 3 4 5 6 7 2 4 6 8 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 296

REM 1-45 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 45-4D-13 [H1] 1.1 4 9 S 23/4 5 D/Y 4.5/2.6 1415 6 772 37/43/63/68 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 45-4X-13-2G [H2] 1. 4 9 S 23/4 5 D/Y 4.33/2.5 142 6 772 42/47/76/81 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 45-4D-14-6 [H3] 1.75 4 9 L 46 6 Y 3.4 172 6 936 4/46/26/71 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-45 REM 13-45 15+k2 Ø12 413 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 REM 18-45 REM 19-45 15+k2 Ø1 7 358 324 284 2 112 146 332 364 Ø12 4 112 566 65 639 82 6 M8 364 146 6 M8 6 Ø9.5 4 112 566 65 639 Ø453 Ø487 Ø513 13 3 2 112 868 76 284 324 358 48 342 3 448 6 713 3 341 22 346 522 22 863 522 569 288 13 35 755 755 3 413 342 342 3 76 522 LG 22 448 6 341 3 RD 713 ZSG ZKE 11 ZKF 11 ZBG ZKE 16 ZKF 16 LG LG 9 LG 18 LG 27 RD RD 9 RD 18 RD 27 297

REM 1-5 Direct driven centrifugal fans / REM / 1 8 6 4 2 78 db 79 REM 1.-5-4D-16 REM 1.-5-4X-16-2G 4 V 5 Hz [I1/I3] 82 84 86 16 12 8 4 82 db 83 REM 1.-5-4D-17-6 46 V 6 Hz [I4] 86 88 9 2 4 6 8 1 2 4 6 8 1 12 4 3 67 db 68 REM 1.-5-6D-11 4 V 5 Hz 7 [I2] 6 5 4 71 db 72 REM 1.-5-6D-13-6 46 V 6 Hz [I5] 74 2 73 3 77 1 76 2 1 8 1 2 3 4 5 6 1 2 3 4 5 6 7 8 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 298

REM 1-5 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 5-4D-16 [I1] 2.2 4 1 L 23/4 5 D/Y 8.2/4.75 1425 6 1116 56/62/94/1 5-6D-11 [I2].55 6 8 23/4 5 D/Y 2.8/1.6 91 6 712 46/52/84/9 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 5-4X-16-2G [I3] 2. 4 1 L 23/4 5 D/Y 7.8/4.5 142 6 1116 68/74/16/112 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 5-4D-17-6 [I4] 3.45 4 1 L 46 6 Y 5.9 171 6 1324 6/66/98/14 5-6D-13-6 [I5].86 6 9 S 46 6 Y 2.5 198 6 853 49/55/87/93 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-5 REM 13-5 167+k2 Ø12 457 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 REM 18-5 REM 19-5 167+k2 Ø1 7 392 358 318 2 112 163 368 398 Ø12 5 112 635 674 78 82 6 M8 398 163 6 M8 6 Ø9.5 5 112 635 674 78 Ø57 Ø541 Ø567 13 3 2 112 957 46 318 358 392 451 37 326 56 652 783 326 376 22 381 574 22 95 574 638 322 13 35 827 827 326 457 37 37 326 46 574 LG 22 56 652 376 326 RD 783 ZSG ZKE 11 ZKF 11 ZBG ZKE 16 ZKF 16 LG LG 9 LG 18 LG 27 RD RD 9 RD 18 RD 27 299

REM 1-56 Direct driven centrifugal fans / REM / 12 1 8 6 82 db REM 1.-56-4D-19 REM 1.-56-4X-19-2G 4 V 5 Hz 83 [J1/J3] 86 88 2 15 1 87 db 88 REM 1.-56-4D-21-6 46 V 6 Hz [J4] 91 93 4 9 2 2 4 6 8 1 12 14 5 4 8 12 16 95 6 5 4 71 db 72 REM 1.-56-6D-14 4 V 5 Hz [J2] 75 8 7 6 5 75 db REM 1.-56-6D-16-6 46 V 6 Hz 76 79 [J5] 3 2 77 79 4 3 2 81 83 1 1 2 4 6 8 2 4 6 8 1 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 3

REM 1-56 Direct driven centrifugal fans / REM / power Poles frequency speed max. REM..- kw V Hz A 1/min C kg 56-4D-19 [J1] 4. 4 112 M 4/69 5 D/Y 8.2/4.7 1435 6 1564 87/94/133/14 56-6D-14 [J2] 1.1 6 9 L 23/4 5 D/Y 4.9/2.85 915 6 116 65/72/111/118 power Poles frequency speed max. REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 56-4X-19-2G [J3] 3.6 4 112 M 23/4 5 D/Y 13./7.5 1435 6 1564 91/98/137/144 power Poles frequency speed max. REM..-6 Hz kw V Hz A 1/min C kg 56-4D-21-6 [J4] 6.3 4 132 S 46 6 D 1.8 174 6 1885 98/15/144/151 56-6D-16-6 1.75 6 1 L 46 6 Y 3.65 113 6 1212 68/75/114/121 protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-56 REM 13-56 187+k2 Ø12 512 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 REM 18-56 REM 19-56 187+k2 Ø1 75 431 397 357 3 112 183 45 435 Ø12 6 112 712 751 785 82 8 M1 435 183 8 M1 8 Ø11.5 6 112 712 751 785 Ø569 Ø65 Ø639 13 35 3 112 183 92 357 397 431 884 55 49 372 28 28 56 743 372 422 247 431 639 247 639 162 13 35 921 715 361 921 372 512 49 49 372 92 639 LG 247 422 372 28 28 56 743 RD 884 ZSG ZKE 11 ZKF 11 ZBG ZKE 16 ZKF 16 LG LG 9 LG 18 LG 27 RD RD 9 RD 18 RD 27 31

REM 1-63 Direct driven centrifugal fans / REM / 16 14 12 86 db REM 1.-63-4D-23 REM 1.-63-4X-23-2G 4 V 5 Hz 86 [K1/K3] 88 1 8 91 6 94 4 2 5 1 15 2 7 6 5 75 db 76 [K2] REM 1.-63-6D-19 4 V 5 Hz 78 1 8 79 db 8 REM 1.-63-6D-21-6 46 V 6 Hz 82 [K4] 4 81 6 85 3 2 83 4 87 1 2 2 4 6 8 1 12 14 4 8 12 16 Density of media 1.2 kg/m³ Measured in installation B according to ISO 581 32

REM 1-63 Direct driven centrifugal fans / REM / speed max. frequenction Connec- power Poles REM..- kw V Hz A 1/min C kg 63-4D-23 [K1] 7.5 4 132 M 4/69 5 D/Y 15.4/8.9 145 6 2237 /13/ / 63-6D-19 2.2 6 112 M 23/4 5 D/Y 9.2/5.3 93 6 1476 95/13/151/159 speed max. frequenction Connec- power Poles REM..-Ex II 2G c IIB T3 kw V Hz A 1/min C kg 63-4X-23-2G [K3] 6.8 4 132 M 4/69 5 D/Y 14./8.1 146 6 2237 /135/ / speed max. frequenction Connec- power Poles REM..-6 Hz kw V Hz A 1/min C kg 63-6D-21-6 [K4] 3.45 6 132 S 46 6 Y 6.9 1145 6 1762 14/112/166/168 For "REM..-63-4D-23" and "..-4X-23-2G" only model "13-" available! protection can take place through protection units with bi-metallic releases (EUM 33) or via a thermistor (NTC) temperature sensor in connection with a thermistor (NTC)-release device (EUM 3). See chapter "Accessories". The direction of rotation is determined looking from the drive side. - Anti-clockwise rotation, symbol LG. - Clockwise rotation, symbol RD. Dimensions in mm, subject to change. REM 11-63 REM 13-63 28+k2 Ø12 574 k2 71 21 8 234 9 S 282 9 L 282 1 L 316 112 M 334 132 S 374 132 M 374 REM 18-63 REM 19-63 28+k2 Ø1 85 474 44 4 3 112 25 448 478 Ø12 6 112 798 837 871 82 478 8 M1 25 6 M1 8 Ø11.5 6 112 798 837 871 Ø638 Ø674 Ø78 13 35 3 112 124 74 4 44 474 984 567 454 41 336 336 672 82 41 473 279 479 715 279 715 1188 a3 b3 13 35 128 128 41 574 454 454 41 74 715 LG 279 473 41 336 336 672 82 RD 984 ZSG ZKE 11 ZKF 11 ZBG ZKE 16 ZKF 16 LG LG 9 LG 18 LG 27 RD RD 9 RD 18 RD 27 33