Integrated Flow Control Module for Slurries and Chemicals LFC-7000

Similar documents
LFC Integrated Flow Control Module. Description Malema Sensors

LFC Integrated Flow Control Module. Description.

MFC Integrated Flow Control Module For Slurries and Chemicals. Key Features. applications.

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications

Inline Ultrasonic Flowmeter

M-100 Adjustable flow switch with right-angle flow

NT ELECTRONIC FLOWMETER, MODEL 4400

InVue Electronic Flowmeter, NT4400

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

Integrated Flow Controller, Model NT6500

NT Flowmeter, Model 4401

MODEL U801 PTFE Flo-Controller for UHP Liquid Applications. uhp

English. Instruction and operation manual S 212. Dew point sensor

PPM100 Owner s Manual

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

InVue Electronic Flowmeter, Model NT4400

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

NT PROPORTIONAL CONTROL VALVE, MODEL 6300

2-Color Display High-Precision Digital Pressure Switch

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Description. Measurement Principle. Key Features. Applications. Malema SUMOFLO. 1 Barb Single-Use Sensor for g/min

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

Differential Pressure Transmitter

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

Specification: Industrial Mixing Center

A Member of the. Integrated Metering Technologies

11202 INSTALLATION INSTRUCTIONS

Thermal Mass Flow Meter (Analog)

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Series 10-ZSE40A(F)/10-ISE40A

Ultra Compact UHP Liquid Flow Controllers

INVUE INTEGRATED FLOW CONTROLLERS, MODELS NT6510, NT6520. User guide

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Low Pressure Sensor. Overview. Specifications. Installation and Operation

PFA Eddysonic flowmeter

MODEL 106F TEFLON LIQUID FLOW SENSOR

HYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS DIAGRAMS

FL-100-R (109) Operations and Installation Manual

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

2 Model 826 Dispensing Valve User Guide

Time Delta S Fixed Transit-Time Flow Meter System

Installation and Operating Manual

Defender 3000 Series Base Instruction Manual

Installation. Global Vision Inc Jefferson Hwy - Osseo, MN USA - ph fx

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

ProFlo FatBoy

Operator Instructions for Tension Links

Smart Pressure Transmitter

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

Ultrasonic heat meter

KOBOLD DF-MA Flow Transmitter. User Instructions

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

Optidew Vision Optical Dew-Point Meter

ENC 150 REFERENCE MANUAL ACU-RITE

MoistureMatch A next generation grain tester

An Innovative Flow Sensor

Application Engineering

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples.

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

INSTALLATION INSTRUCTIONS

Smart Pressure Transmitter

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

Active Controlled Cooling System

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

DPS280 / DVS280 Series

Application Engineering

ELECTRONIC CONTROLLER

Digital Flow Switch (Sensor Part) Operation Manual

FlowCon Energy FIT System

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

NECO Pumping Systems

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

18318 INSTALLATION INSTRUCTIONS CHEVROLET IMPALA

OM Field-Type I/P Converter Model : KUX113 User's Manual

HGM-MZ Multi-Zone Monitor Annual Maintenance And Troubleshooting Guide

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

M-50/55 Series. Fixed setting flow switch with in-line flow

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

HCT-10 Temperature Controller User Manual

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

2-Color Display High-Precision Digital Pressure Switch

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

EMERSON CLIMATE TECHNOLOGIES-EX

Pressure Transmitter

Transcription:

Integrated Flow Control Module for Slurries and Chemicals LFC-7000 Operating Instructions and Quick-Start Guide

TABLE OF CONTENTS Introduction 3 Storage and Handling 3 Installation Instructions 4 Operating Principle and Block Diagram 5 Operation 6 Specifications 8 Power & Signal Connection 9 Dimensional Drawings 10 Ordering Information 11 Warranty 12 Service and Repair 12 2

Introduction The LFC-7000 Series is a line of high-performance closed-loop flow controllers designed for use in a wide variety of high-purity liquids including DI water, harsh chemicals, and CMP polishing slurries. A typical module for high-accuracy control of ultrapure chemicals combines Malema ultrasonic flow meter, with accuracy rated at +/- 1% reading, with Malema control valve. The ultrasonic flow meter has an all PFA construction with no moving parts or seals. It sets a standard for flow measurement in terms of accuracy, repeatability, turndown, and purity. Its digital signal processing technology ensures reliable performance even with a certain degree of bubbles present in the process fluids. The high speed/precision motor actuated pinch valve (for slurries) or diaphragm valve (for chemicals) helps provide a fast, precise response with minimal overshoot. Its all PTFE construction and minimal dead volume ensure maximum process purity and reliability. In operation, the user inputs a flow rate set point via an analog signal. The flow control electronic modules continuously compares this set point value with the flow rate reported by the flow meter and provides a continuous signal to modulate the control valve to maintain the desired set point. State of the art control algorithm together with a high speed/precision flow meter and valve achieves fast, accurate, and repeatable control. Storage and Handling Storage conditions Store the product under packed condition in an anti-static bag. The storage place shall be free from moisture, mechanical shock and vibration. The ambient temperature shall be between 0 C and 60 C and the humidity between 5% and 80% R.H. without condensation. Unpacking and Product Inspection On delivery, check the product for damage. Confirm that the model code on the label matches the specification in the purchase order. 3

Installation Instructions LFC 7000 series liquid flow control modules are equipped with inlet/outlet ports with Flare or S300 Pillar connections of 1/4, 3/8 or 1/2 size. The modules are available for mounting in either the vertical or horizontal directions. The module designed for vertical mounting is not recommended to be mounted in the horizontal direction and vice-versa. It is important to note that the mounting direction is defined based on the orientation of the flow meter inside the module. Following the specified orientation ensures no trapped air pockets during usage. The module for liquid chemicals, without abrasive particles, is assembled with a diaphragm type control valve and the module for liquid slurries is assembled with a pinch type control valve. The envelope dimensions are influenced by the type of flow control valve and also the desired mounting direction. Refer to the drawings on page 10 for envelope dimensions. Fluid Connections The pipe ends should be flared with the correctly sized tool and the in/out ports are connected. Choose the appropriate fittings & flare tool for the required pipe size. Make sure the inlet and outlet pipes are flared and assembled perfectly so they are leak proof. This facilitates safety while in use with corrosive chemicals. Provide a shut off valve or bypass valve to facilitate the zero reset, inspection, and maintenance as well as for positive shut-off. Avoid piping stresses and torque on the module ports. Over-tightening the nuts at the inlet and outlet may loosen the bulk head fittings. It is always recommended that the inlet port should be at a lower level than the outlet port. This eliminates air entrapment during flow measurement. Operating Environment Choose a location with ambient temperature 10-40ºC and relative humidity value <80% RH without direct sunlight. Avoid environments with high electromagnetic noise or vibration. Make sure that the module is protected from corrosive liquid or water splashes. For Best performance avoid these environments (corrosive liquids and/or vapor) since they may degrade the performance of the electronics after a period of time. Easy access for maintenance and inspection is always recommended. 4

Operating Principle & Block Diagram The user inputs a set point using either an analog signal or a PC GUI command. The flow control module s electronics continuously compares the set point value with the measured flow rate and provides a continuous feedback signal to modulate the control valve in order to maintain the desired flow rate. Custom designed and user selectable control parameters insure fast response time and accuracy. PC EXTERNAL I/O FLOW READING CONTROL SIGNAL SET POINT CONTROLLER ELEC. FLOW READING SERIAL COMMUNICATION FOR PC CONTROL (FOR DIAGNOSTICS) FLOW OUT FLOW METER FLOW IN 5

Operation Safety: The inlet/outlet ports should be properly connected. Parameter Setting The parameters are preset at the factory prior to shipment as per the customer s specifications Before Power-On Confirm: a) Cables are properly connected to the terminals as per pin configuration of connectors. b) Supplied Voltage must be in accordance with specifications. c) Mounting orientation matches specifications. After Power-On Wait 5 minutes for the module to warm up prior to achieving the specified performance. Zero Adjustment Ultrasonic flow meters will show a signal error when the flow path is empty, or filled with large air pockets. The user should make sure that the flow path of the module is filled with process fluid before adjusting the zero. The fluid needs to be at rest, in order to complete an accurate zero adjust. Malema recommends using a shut off valve to bring the fluid to rest. The Zero Adjustment is performed by momentary suppling 24 Vdc to pin#11. (Malema recommends using a momentary push button). Please make sure that the power supply to pin#11 is momentary and not continuous. It takes less than 5 seconds for zero adjustment. If this wiring setup is not adopted, the zero adjustment can be done using the Malema PC communication software. Please refer to the manual for the Malema UFM PC communication software. It is not necessary to do a Zero Adjustment whenever the power is turned on, only when there is a change in the process fluid properties. Confirmation of Flow Through the Module This procedure ensures the proper functioning of the flow controller. If a set point value of 2Vdc is given to the module with 0-10Vdc input, which is equal to 20% of the full scale flow, the controller accepts the set point value and adjusts the control valve to deliver 20% of the full scale flow. After 10 seconds, observe the analog output from the module. This should be equal to 20% of the full scale flow (for example: in case of 4-20mA, 20% analog signal will be 7.2 ma). An unstable flow value or a zero may indicate that there are air bubbles present in the flow path that need to be eliminated. 6

Flow Controller Configuration The LFC-7000 series flow controller is configured at the factory and calibrated with DI water. The parameters should be modified by an authorized service technician only. The configuration of the flow controller is done by using custom communication software. This software is installed on a PC. Connect the PC to the unit using a special 6 pin communication cable (PN#: CABLE-LFC-PROG-001). The 6 pin communication port on the unit is located just below the 12 pin main electrical connector. A detailed software operations manual is available with all Malema service personnel. Alarm Output a) Alarm 1 - PID Control Error Alarm Controller is supposed to meet the control accuracy within 3 seconds in normal use. In case the flow rate does not meet the set point, the control valve action with maximum torque can last for a long time, and may put unnecessary strain on the control valve. When this condition lasts for longer than the set time (configurable, default value is 15 seconds), the controller considers this situation abnormal, activates the alarm signal, and then stops controlling. b) Alarm 2 - Sensor Signal Strength Alarm This alarm signal is given when flow sensor is in Empty Sensor state. Empty Sensor means that the flow sensor does not have a qualified sound signal, e.g., the sensor is not fully filled up with fluid, namely, bubble(s) or foreign matter are in the flow sensor, or when the sensor cable is disconnected. Inspection Malema advises the user to inspect the flow controller periodically to ensure that there are no visible signs of leakage and electrical connections/cables are secure and damage free. The following is a checklist to ensure all inspection points are covered. a) No excessive heat generation inside apparatus b) No excessive piping stress by bending c) No vibration on piping system d) No liquid leakage, no penetration, no condensation e) No air bubbles, no contamination in piping f ) Firm wiring on all terminals g) No damage on electric wiring in apparatus NOTE: Refer to the PC communication software manual of Malema UFM/LFC for more details on device operation 7

Specifications Performance Specifications Standard Full Scale Range Accuracy ** (for room temperature DIW) Repeatibility ** Control Repeatibility Flow Control Time 50 ml/min 100 ml/min 250 ml/min 500 ml/min 1000 ml/min 1500 ml/min 2500 ml/min* 4000 ml/min* 8000 ml/min* 12000 ml/min* ±1% of set point or ±3mL/min (whichever is larger) ± 1% of set point or ± 1 ml/min (whichever is larger) ± 0.5% of set point or ± 0.5 ml/min (whichever is larger) < 3 sec Fluid Temperature 10-60 ºC *** Ambient: Temperature / Humidity Maximum Expected Operating Pressure Maximum Safe Internal Pressure 0-40 ºC / 30-80% RH, without Dew 50 psig 70 psig Differential Pressure Range 7 to 30 psid * The enclosure footprint may be larger for these flow ranges to meet the pressure drop specification. The minimum differential pressure requirements can be higher for these ranges. ** Please consult with Malema for tighter accuracy/repeatability needs. *** Consult the factory for higher temperature application Electrical Specifications Electrical Input 24 Vdc ±10% Consumption Alarm Signals Control Signal In* Flow Signal out* * Other options available ** Both Active and Passive options available Material Specifications Max 500 ma Max 30 Vdc, 200 ma NPN open collector 0 to 10 Vdc or 4 to 20 ma 0 to 10 Vdc or 4 to 20 ma** Wetted parts for Modules of Slurry Application Non wetted parts, enclosure * Only used in the Slurry Module ** Flame retardant (FMET4325) PFA, PTFE, Pt cured Silicone* PPS, PEEK, Acrylic, Vinyl, PVC** 8

Physical Specifications Mounting Orientation Fluid Connections Flow Restrictions (orifice) Ingress Rating Horizontal or Vertical Inlet/Outlet: 1/4, 3/8, or 1/2 ; Flare or Pillar > 2 mm IP64 Power and Signal Connections It is always recommended to use a dedicated power supply with 24 Vdc (±10%), 500mA. The configuration of the 12 pin-connector and its mating cable is given in the table below. A communication cable with a 6 pin connector can be ordered seperately to interface with the PC GUI program. Custom pin configurations and connectors are available upon request. Pin No. 12 Pin Connector Configuration Wire Color Description Specification Remarks 1 Red Power (+) 24 Vdc 2 Black Power (-) 0 Vdc 3 Pink Set Point (+) 4 Gray Set Point (-) 24 Vdc ± 10% 4-20 ma or 0-10 Vdc 5 Blue Flow Out (+) 4-20 ma (Max. load 900 ohm) or 6 White Flow Out (-) 0-10 Vdc 7 Red/Black Valve Alarm (+) 8 White/Black Valve Alarm (-) (0V) 9 Yellow Sensor Alarm (+) 10 Brown Sensor Alarm (-) (0V) 11 Green Zero Adjust* 12 Violet No Connection * Make sure the flow is completely stopped before zero adjust. Max. rating 30 Vdc, 200 ma Max. rating 30 Vdc, 200 ma 0 Vdc: Normal operation 24 Vdc: Zero Adjust Open Collector Output Open Collector Output Pull up to power supply voltage to start zero adjustment 9

Dimensional Drawings (Horizontal Modules) Chemial Version Slurry Version 10

Order Information Model Code LFC-700 * - * * * * * - * * * - *** Alarms and Display Tube Size Connection Type Description 0 No Alarms or Display 1 Alarms and Display on Top Panel 2 Alarms and Display on Front Panel Standard Full Scale Range Sensor / Converter - Input / Output 2 1/4 3 3/8 4 1/2 Valve Type Mounting Orientation 1 Flare Ends 2 Super Pillar 300 Accessories 0 50 ml/min 1 100 ml/min 2 250 ml/min 3 500 ml/min 4 1000 ml/min 5 1500 ml/min 6 2500 ml/min 7 4000 ml/min 8 8000 ml/min 9 12000 ml/min 1 M-2111 (6 mm) / DSP 2 M-2111 (4 mm) / DSP 3 M-2111 (10 mm) / DSP 1 0 to 10 Vdc / 0 to 10 Vdc 2 4 to 20 ma / 4 to 20 ma 3 0 to 10 Vdc / 4 to 20 ma 4 Others - 1 Diaphragm Valve 2 Pinch Valve 1 Horizontal 2 Vertical 1 without plug connector 2 with plug connector and cable - xxx Unique PN identifier 11

Warranty Malema Sensors warrants to the buyer that its products are free from defects in materials and workmanship at the time of shipment and during the WARRANTY PERIOD. Malema Sensors obligation under this warranty is limited to the replacement of the product(s) by same product(s) manufactured by Malema Sensors or repair of the product(s) at the Malema Sensors facility. Malema Sensors products are sold with the understanding that the buyer has determined the applicability of the product(s) to its intended use. It is the responsibility of the buyer to verify acceptability of performance to the actual conditions of use. Performance may vary depending upon these actual conditions. Warranty Period This warranty is in effect for twelve (12) months from the date of shipment from Malema Sensors place of business. Warranty Claim If Malema Sensors products are found to be defective in materials or workmanship within twelve (12) months of the date of shipment, they will be repaired or replaced with same product at the discretion of Malema Sensors at its place of business at no charge to the buyer. Service and Repair To return the products, please obtain an RMA number for the product by contacting Malema Sensors (Corporate Office), Boca Raton at (800) 637-6418 or (561) 995-0595. All returns of equipment must go to the following address: Malema Sensors, Boca Raton, FL 33487, USA 12 NOTE: Specifications are subject to change without notice. LFC7000_IM_414140A