EFC Instructions Manual

Similar documents
LEIHDS110SC/ LEIHDS110BC/ Instructions Manual.

RMHDT90SS/ - RMHDT100SS/ - RMHDT110SS/ Instructions Manual.

Instructions for use and installation Cooker Hood

KSEV97X. IT Libretto Istruzioni GB Instruction Manual. 11 FR Manuel d Instructions 20 DE Bedienungsanleitung 29 NL Gebruiksaanwijzing

INDEX RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 6 INSTALLATION USE MAINTENANCE... 33

KH E, KH E

INSTRUCTIONS FOR MAINTENANCE AND USE KITCHEN EXTRACTOR HOOD ZRW 50/60

INSTRUCTIONS FOR INSTALLATION AND USE

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

220/240 AC x 25 W

NUTONE RANGE HOOD NTM SERIES

Hood. warning. warning. caution

Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

OWNER S MANUAL POWER INVERTER

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

C3 Operating Instructions

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

! FOR DOMESTIC COOKING ONLY!

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

When Time Matters! listed Fire Damper

SERVICE MANUAL HOT DELI 3/4/5/7 MERCHANDISERS

VICTRIX PRO Wall-hung modular condensing boiler for heating only

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Installation Operation Parts

Assembly Instructions

WhispAire Range Hood Quiet Hood

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

! FOR DOMESTIC COOKING ONLY!!

Diesel Cooker X 100. Installation Instructions

rangehoods SA520TX90 90cm telescopic rangehood SA520TX60 60cm telescopic rangehood

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

READ AND SAVE THE INSTRUCTIONS

INSTRUCTIONS FOR OPERATION

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

DIAGNOSTIC POWER SUPPLY WSC 720. user guide. 12 V/24 V lead acid batteries ah

MOVING HEAD. User manual CAUTION!

Astor 20 Colony Counter User s Manual

Maintenance Adjustments

User Manual. Model: FSL300 Dual Port Laser Fume Extractor

Roller Door Operator

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

HOODS HOODS PLAY AN IMPORTANT ROLE IN THE KITCHEN, BOTH AESTHETIC AND FUNCTIONAL. DESIGNED. Range Versatility

OWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

EC225 Power Control System

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Owner skit. Manuale per l installatore Installer s guide Installations- Anweisungen Notice installateur SL2380

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

Light Source User Guide

Indoor air quality sensor.

Alliance Towel Dispensing System. Operation Manual

Compressor Refrigerator Instruction Manual

Zip FlushMaster Surface mounted sensor

MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces

Electric Vehicle Charging Station

USER GUIDE 12 V Lead acid batteries Ah

GENUINE PARTS INSTALLATION INSTRUCTIONS

Operating Instructions BNT-40 Automatic Rebar Tying Machine

Industrial flue gas probes. Instruction manual

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

Pro Island Ventilation Hoods

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

EC200 ELECTRONIC CONTROL SYSTEM

Operation Manual RANGE HOOD

BEDIENUNGSANWEISUNG KD KD KD KD KD KDEM KDEM mit Montageanweisungen

DIGI-CUT 40PFC MV. Part No. 9030H OPERATOR S MANUAL

Q35 Series Automatic Vent Damper System

Dealer4 Maintenance, Adjusting and Cleaning Manual ver: 1.0

Light oil - kerosene burner

Maintenance notice proceeding

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

MODEL RVS304. REMOTE CONTROLLED SAFETY PILOT KIT Supplemental Installation Instructions for use with Natural Gas Log Sets

PETROL GENERATOR PGH2200, PGH3000, PGH6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

CLASSEQ LTD. Spares manual P500A

USER MANUAL 12V 4.3A 5 YEAR WARRANTY. FOR ALL 12V TYPES OF LiFePO 4 BATTERIES FULLY AUTOMATIC

User Instruction manual for Cardale Autoglide

PETROL GENERATOR SPG2200, SPG3000, SPG6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

TABLE OF CONTENTS. 300 W Mobile Power Outlet SAVE THESE INSTRUCTIONS!

Gavita HortiStar 1000 DE EU/US

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

AXIAL FANS Axis / Tubo OPERATION MANUAL

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

JUMP STARTER OPERATOR S MANUAL RA1900

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

Before replacing LED light ensure the unit is switched off, when you want to

RA-7730SS RA-7736SS RA-7742SS RA-7748SS. For residential and indoor use only.

Flue installation instructions. Air flue duct for use with ecomax and ecotec boilers. For the installer

Mod: KLD6-12/35XLAS-N

CLASSEQ LTD. Spares manual P500 AS WS

WhispAire Range Hood Quiet Hood

General Description. Product Specification. Document Digital Temperature Interlock

Transcription:

EFC 9542 Instructions Manual

Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS...3 CHARACTERISTICS...4 INSTALLATION...5 USE...8 MAINTENANCE...10 EN 2

RECOMMENDATIONS AND SUGGESTIONS INSTALLATION The manufacturer will not be held liable for any damages resulting from incorrect or improper installation. The minimum safety distance between the cooker top and the extractor hood is 650 mm. Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood. For Class I appliances, check that the domestic power supply guarantees adequate earthing. Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible. Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.). If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. Never use the hood for purposes other than for which it has ben designed. Never leave high naked flames under the hood when it is in operation. Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides. Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. The hood should not be used by children or persons not instructed in its correct use. The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance. MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. Clean and/or replace the Filters after the specified time period. Clean the hood using a damp cloth and a neutral liquid detergent. 650 mm min. EN 3

CHARACTERISTICS Dimensions 650 min. Components 15 14.1 Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising: 2.1 1 Upper Section 2.2 1 Lower Section 9 1 Reducer Flange ø 150-120 mm 14.1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Section Fixing Brackets 7.3 1 Air Outlet Connection Support 11 6 Wall Plugs 12a 6 Screws 4,2 x 44,4 12c 6 Screws 2,9 x 9,5 Q.ty Documentation 1 Instruction Manual 9 2 1 2.1 2.2 7.3 12a 7.2.1 11 12c 11 12a EN 4

INSTALLATION Wall drilling and bracket fixing 1 2 7.2.1 11 12a 116 116 650 min. 330 X Wall marking: Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. Draw a horizontal line at 650 mm above the hob. Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line. Mark the wall at the centres of the holes in the bracket. Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line. Mark the wall at the centres of the holes in the bracket. Mark a reference point as indicated at 116 mm from the vertical reference line and 330 mm above the horizontal reference line. Repeat this operation on the other side. Drill ø 8 mm holes at all the centre points marked. Insert the wall plugs 11 in the holes. Fix the lower bracket 7.2.1 using the 12a screws (4,2 x 44,4) supplied. Fix the upper bracket 7.2.1 and the air outlet connection support 7.3 together using the 2 screws 12a (4,2 x 44,4) supplied. Insert the two screws 12a (4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap of 5-6 mm between the wall and the head of the screw. EN 5

Mounting the hood body Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points. Hook the hood body onto the screws 12a. Fully tighten support screws 12a. Adjust screws Vr to level the hood body. 12a Vr Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. Fix the pipe in position using sufficient pipe clamps (not supplied). Remove any activated charcoal filters. ø 150 9 ø 120 RECIRCULATION VERSION AIR OUTLET Put connection 15 into the connection support 7.3. Insert the connection extension pieces laterally 14.1 in connection 15. Make sure that the outlet of the extension pieces 14.1 is horizontally and vertically aligned with the chimney outlets. Connect the air outlet connection 15 to the hood body outlet using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer. Ensure that the activated charcoal filters have been inserted. 15 14.1 ø 150 EN 6

ELECTRICAL CONNECTION Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. Flue assembly 7.2.1 Upper exhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1, making sure that they are well seated. Secure the sides to the brackets using the 4 screws 12c (2,9 x 9,5) supplied. Make sure that the outlet of the extensions pieces is aligned with the chimney outlets. 2 2.1 2.2 12c 12c Lower exhaust flue Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated. Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied. 12c EN 7

USE L T1 T2 T3 T4 T5 F The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button. Touch Basic functions Indicator lights control Dual Function L When briefly pressed it switches the lighting system Touch control unlit Lights off on and off. When pressed for 2 seconds it starts the lighting system in courtesy light mode. The lamps are fed at a reduced power of approximately 5W. Such function can be stopped by pressing the touch control for 2 seconds or just by pressing it shortly in order to return to the normal lighting mode. In courtesy light mode the touch control is not lit. Touch control lit Touch control unlit Lights on Courtesy light on T1 When pressed the motor is stopped, regardless of the Touch control lit Motor on speed it is set to. Touch control unlit Motor off T2 T3 When pressed the motor is set to the first speed By a brief pressing the motor is set to the second Touch control lit speed. By pressing the touch control for approximately 2 Flashing touch seconds the Delay function is enabled, i.e delayed control shutdown of the appliance ensuring a com- plete elimination of the residual odours. This function can be activated at OFF-position and at 1, 2 and 3 speeds. It can be stopped in advance by pressing any of the touch controls (T) with the exception of T3. The Delay function works according to the following scheme: 1 speed / OFF = 20 minuets 2 speed = 15 minutes 3 speed = 5 minutes T4 When pressed the motor is set to the third speed Touch control lit Touch control lit Second speed on Delay function on EN 8

Touch control T5 F Basic functions When pressed the motor is set to the intensive speed timed to 5 minutes. At the end of 5 minutes of intensive speed the hood starts again at the speed it was set to previously. In case the hood is set to the intensive speed directly from OFF-state it will then start from the first speed after 5 minutes of intensive speed. When pressed for 4 seconds it resets the filter alarm signal indicated by flashing of the touch control T1. This procedure can be carried out only when the motor is stopped. Indicator lights Touch control lit Flashing touch control Touch control lit Metal grease filters saturation alarm. Metal grease filters need to be washed. The alarm starts up after 100 working hours. Charcoal odour filter saturation alarm. Charcoal filter has to be replaced and metal grease filters washed. The alarm starts up after 200 working hours. (Activation; check the paragraph Odour filter ) EN 9

MAINTENANCE Grease filters CLEANING OF THE METAL CASSETTE FILTERS Alarm reset Stop the motor. Press the F -touch control for at least 4 seconds until the T1 -touch control flashes. Cleaning the filters Filters can be washed in the dish machine. They need to be washed every 2 months or even more frequently in case of particularly intensive use of the hood. Remove the filters one by one pushing them towards the back side of the unit and simultaneously pulling downwards. Any kind of bending of the filters has to be avoided when washing them. Before fitting them again into the hood make sure that they are completely dry. When fitting the filters into the hood pay attention that they are mounted in correct position and that the handle faces outwards. EN 1 10

Odour filter (Recirculation Version) This filter cannot be washed or regenerated, and must be replaced when the F touch control starts to flash, or at least once every 4 months. The alarm is only triggered when the motor is on. Enabling/Disabling the alarm signal In Recirculation Version Hoods, the Filter saturation Alarm must be enabled at the time of installation or later. Switch off the lights and the motor. Disconnect the mains power supply to the hood by removing the motor unit power supply cable connector, switching off the power supply at the Mains or turning the Main switch off. Restore the connection, pressing and holding T2. Release the touch control, touch controls L, T2 and F will light up normally. Within 3 seconds press the touch control F until the key itself flashes to confirm as follows: 2 flashes Charcoal odour Filter saturation Alarm ENABLED 1 flash - Charcoal odour Filter saturation Alarm DISABLED REPLACING THE CHARCOAL ODOUR FILTER Reset the alarm signal Stop the motor. Press the touch control F for at least 4 seconds, until the touch control T1 flashes. Replace the Filter Remove the metal grease filters. Remove the saturated charcoal filter, turning the fasteners provided. Fit the new filter and fasten it its correct position. Put the metal grease filters in their seats. Lighting LIGHT REPLACEMENT 20 W halogen light. Remove the snap-on lamp cover by levering it from under the metal ring, supporting it with one hand. Remove the halogen lamp from the lamp holder by pulling gently. Replace the lamp with a new one of the same type, making sure that you insert the two pins properly into the housings on the lamp holder. Replace the snap-on lamp cover. EN 1 11

436003102_ver1