Circuit protection and control devices. 0.5 to 6300 A. LV product characteristics

Similar documents
Circuit protection and control devices 0.5 to 6300 A

Circuit protection and control devices 0.5 to 6300 A

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

EasyPact from 15 A to 400 A

Masterpact NT and NW LV power circuit breakers and switch-disconnectors

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

C60H-DC C curve. Catalogue numbers

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

DPX moulded case circuit breakers

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

Compact NSX100 to 630

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Compact Merlin Gerin 80 to 3200 A

3 - Protection components Motor circuit-breakers

cor Long Run Experience

Wall mounted switchgear

Compact NR630. NR100F to NR630F

DMX 3 -I 2500 switch disconnectors

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX 1600 Electronic release

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Low voltage. EasyPact EZC. Moulded-case circuit breakers from 15 to 630 A. Catalogue 2013

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

DPX 630 Electronic release

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX earth leakage DPX 3 -I earth leakage

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Cascading & Discrimination

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

DPX 160 Thermal magnetic and trip-free switches DPX-I 160


DRX 125 Circuit breaker (not adjustable)

NS Feeder pillar up to 3200A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

Vistop TM isolating switches 63 to 160A


DPX Magnetic only

Thermal magnetic and trip-free switches

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

Power protection solutions

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Medium Voltage Distribution. NEX 17.5 kv. Withdrawable vacuum circuit breaker. Catalogue November 2008

Breaking and protection devices

01 Spectra Plus - Introduction

Btdin RCBO 6000A up to 63A (2P)

Compact NS. Installation recommendations

ACW Molded-Case Circuit Breaker UL 489 Listed

AF40... AF96 3-pole contactors Technical data

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

DRX 100 B/N/H Circuit breaker (not adjustable)

EasyPact TM : Build your complete solution with Schneider Electric

WORKSHOP SPECIFICATIONS

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DX³ RCCBs - ID 4P up to 100 A

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

DX³ 4-pole RCBO 6000 A/10 ka

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on left side

Low voltage distribution products

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

DPX Electronic + earth leakage

C1251N DC and C1251N 1000 V

DRX 250 B/N/H Circuit breaker (not adjustable)

4. CIRCUIT BREAKERS (Continued)

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

Masterpact NW DC Circuit Breakers

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

(1,5 modules per pole)

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Masterpact NW DC Circuit Breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TX³ RCCBs 2P up to 100 A

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

(p. 47) (p. 155) (p. 155)

Cat N 3. OVERALL DIMENSIONS

Cascading. Complementary technical information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Price List. Low Voltage Distribution Products. With effect from December 29, schneider-electric.co.in

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

Price List. Low Voltage Distribution Products. With effect from March 12, schneider-electric.co.in

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Transcription:

Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2006

This international site allows you to access all the Merlin Gerin products in just 2 clicks via comprehensive range data-sheets, with direct links to: complete lirary: technical documents, catalogs, FAQs, rochures selection guides from the e-catalog. product discovery sites and their Flash animations. You will also find illustrated overviews, news to which you can suscrie, the list of country contacts According to IEC 60364 This guide, part of the Guiding System, is the essential tool to "guide" you any time in your usiness: design office, consultant contractor, paneluilder teacher, trainer. Comprehensive and concrete information on: all the new technical solutions all the components of an installation from a gloal point of view all the IEC standards modifications all the fundamental electrotechnical knowledge all the design stages, from medium to low voltage.

Circuit protection and control devices Contents Multi 9 Multi 9 circuit reakers from 0.5 to 125 A 6 NG160 Characteristics of NG160 circuit reakers and switch-disconnectors 8 EasyPact EasyPact circuit reakers from 15 to 250 A 10 Compact NS Compact NS AC circuit reakers up to 630 A 14 Compact NS AC circuit reakers from 630 up to 3200 A 16 Compact NS DC circuit-reakers from 100 to 630 A 18 Masterpact NT and NW Masterpact NT06 to NT16 AC circuit reakers and switch-disconnectors from 630 to 1600 A 20 Masterpact NW08 to NW63 AC circuit reakers and switch-disconnectors from 800 to 6300 A 22 Masterpact NW10 to NW40 DC circuit reakers from 800 to 6300 A 24 Micrologic control units - Overview of functions 26 Interpact INS Interpact INS40 to 160 switch-disconnectors 28 Interpact INS250-100 to 630 switch-disconnectors 32 Interpact INS630 to 2500 switch-disconnector 36 Interpact INV Interpact INV100 to 630 switch-disconnectors 40 Interpact INV630 to 2500 switch-disconnectors 44 Manual source-changeover sytems Interpact INS and Compact NS 40 A to 630 A 48 Compact NS and Masterpact NT/NW 630 A to 6300 A 49 Remote-operated source-changeover systems Compact NS100/1600 100 A to 1600 A 50 Masterpact NT/NW 630 A to 6300 A 51 Fupact Fupact INF.32 to INF.800 switch-disconnector fuse 52 Fupact ISFT100 to ISFT630 fuse-switch disconnectors 56 Fupact ISFL160 to ISFL630 fuse-switch disconnectors 60 Vigirex Protection and monitoring relays 64 1

The Guiding System, the new way to create your electrical installations 0 A comprehensive offer of products with consistent design The Guiding System is first and foremost a Merlin Gerin product offer covering all electrical distriution needs. However, what makes all the difference is that these products have een designed to operate togheter: mechanical and electrical compatiility, interoperaility, modularity, communication. Thus the electrical installation is oth optimised and more efficient: etter continuity of supply, enhanced safety for people and equipment, guaranteed upgradeaility, effective monitoring and control. Tools to simplify design and implementation With the Guiding System, you have a comprehensive range of tools - the Guiding Tools - that will help you increase your product knowledge and product utilisation. Of course this is in compliance with current standards and procedures. These tools include technical ooklets and guides, design aid software, training courses, etc. and are regularly updated. For a genuine partnership with you Because each electrical installation is unique, there is no standard solution. With the Guiding System, the variety of cominations allows for genuine customisation solutions. You can create and implement electrical installations to meet your creative requirements and design knowledge. You and Merlin Gerin s Guiding System form a genuine partnership. For more details on the Guiding System, consult www.merlin-gerin.com 2

A consistent design of offers from Medium Voltage to Low Voltage All Merlin Gerin offers are designed according to electrical, mechanical and communication consistency rules. The products express this consistency y their overall design and shared ergonomics. 0 Electrical consistency: Discrimination guarantees co-ordination etween the operating characteristics of serial-connected circuit-reakers. Should a fault occurs downstream, only the circuit-reaker placed immediately upstream from the fault will trip. Each product complies with or enhances system performance at coordination level: reaking capacity, Isc, temperature rise, etc. for more safety, continuity of supply (discrimination) or economic optimisation (cascading). The leading edge technologies employed in Merlin Gerin s Guiding System ensure high performance levels in discrimination and cascading of protection devices, electrodynamic withstand of switches and current distriutors, heat loss of devices, distriution locks and enclosures. Likewise, inter-product ElectroMagnetic Compatiilty (EMC) is guaranteed. Mechanical consistency: Each product adopts dimensional standards simplifying and optimising its use within the system. It shares the same accessories and auxiliaries and complies with gloal ergonomic choices (utilisation mode, operating mode, setting and configuration devices, tools, etc.) making its installation and operation within the system a simpler process. Direct connection of the Canalis KT usar trunking on the Masterpact 3200 A circuit reaker. Communication consistency: Thanks to the use of standard We technologies, you can offer your customers intelligent Merlin Gerin switchoards allowing easy access to information: follow-up of currents, voltages, powers, consumption history, etc. Each product complies with gloal choices in terms of communication protocols (Modus, Ethernet, etc.) for simplified integration in the management, supervision and monitoring systems. Guiding Tools for more efficient design and implementation of your installations. 3

0 SM6 Medium voltage switchoard system from 1 to 36 kv Sepam Protection relays Masterpact Protection switchgear from 100 to 6300 A Trihal MV/LV dry cast resin transformer from 160 to 5000 kva Evolis MV vacuum switchgear and components from 1 to 24 kv. The Technical guide These technical guides help you comply with installation standards and rules i.e.: The electrical installation guide, the protection guide, the switchoard implementation guide, the technical ooklets and the co-ordination tales all form genuine reference tools for the design of highperformance electrical installations. For example, the LV protection co-ordination guide - discrimination and cascading - optimises choice of protection and connection devices while also increasing markedly continuity of supply in the installations. CAD software and tools The CAD software and tools enhance productivity and safety. They help you create your installations y simplifying product choice through easy rowsing in the Guiding System offers. Last ut not least, they optimise use of our products while also complying with standards and proper procedures. 4

0 Compact Protection switchgear system from 100 to 630 A Multi 9 Modular protection switchgear system up to 125 A Prisma Plus Functional system for electrical distriution switchoards up to 3200 A Pragma Enclosures for distriution switchoards up to 160 A Canalis Prefaricated Busar Trunking from 25 to 4000 A PowerLogic Power management Training Training allows you to acquire the Merlin Gerin expertise (installation design, work with power on, etc.) for increased efficiency and a guarantee of improved customer service. The training catalogue includes eginner s courses in electrical distriution, knowledge of MV and LV switchgear, operation and maintenance of installations, design of LV installations to give ut a few examples. merlin-gerin.com This international site allows you to access all the Merlin Gerin products in just 2 clicks via comprehensive range data-sheets, with direct links to: complete lirary: technical documents, catalogs, FAQs, rochures selection guides from the e-catalog product discovery sites and their Flash animations. You will also find illustrated overviews, news to which you can suscrie, the list of country contacts 5

Multi 9 Multi 9 circuit reakers from 0.5 to 125 A 0 056908NR_27 056738R_21 PB100270_16 056984NR_14 DPN Vigi C60 C120 NG125 Multi 9 circuit reakers Numer of poles 1 + N Electrical characteristics Rated current (A) In 4-40 Rated insulation voltage (V) Ui 300 Impulse withstand voltage (kv) Uimp 4 Maximum operational voltage (V) Ue AC 50/60 Hz 230 Fast closing Suitaility for isolation and positive contact indication AC reaking capacity (ka rms) IEC 60898 (EN 60898) Icn 230/400 V 6 IEC 60947-2 (EN 60947-2) Icu 130 V - 240 V - 400 V - 415 V - 440 V - 500 V - Ics (% of Icu) - Trip units (non adjustale) Curve type B (lm = 3 to 5 ln) C (lm = 5 to 10 ln) D (lm = 10 to 14 ln) - K (lm = 10 to 14 In) - Z (lm = 2.4 to 3.2) - MA (lm = 12 ln) - Earth leakage protection Add-on rcd's (Vigi module) - Integrated Sensitivity type (ma) a AC 30-300 A 30 k A si 30-300 A si E - Electrical auxiliaries Auxiliary and alarm switches (OF-SD) Shunt trip (MX); undervoltage release (MN) Emergency stop opening switch (MNx) Voltage threshold release (MSU) Connection Cale maxi capacity (mm 2 ) Flexile 10 Rigid 16 Installation Plug in ase - Terminal shieds - Padlocking device Rotary handle - Dimensions (mm) W 36 H 81 D 70 DPN N Vigi 6

Multi 9 C60N C60H C60L C120N C120H NG125N NG125H NG125L 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 0.5-63 0.5-63 0.5-25 32-40 50-63 63-125 10-125 10-125 10-80 10-80 500 500 500 500 500 500 500 690 690 690 6 6 6 6 6 6 6 8 8 8 440 440 440 440 440 440 440 500 500 500 6 10 - - - 10 15 - - - 20-30 - 50-50 - 50-20 - 30-50 - 70-100 - 10 20 15 30 25 50 20 40 15 30 10 20 15 30 25 50 36 70 50 100 3 10 4 15 6 25 5 20 4 15 3 10 4.5 15 6 25 9 36 12.5 50 3 10 4 15 6 25 5 20 4 15 3 10 4.5 15 6 25 9 36 12.5 50-6 - 10-20 - 15-10 - 6-10 - 20-30 - 40 6 8 6 10 6 12 75 % 50 % 50 % 50 % 50 % 75 % 50 % 75 % 75 % 75 % - - - - - - - - - - - - - - - - - - y 40 A - - - 10-1000 10-1000 10-1000 30-1000 30-500 30-1000 30-1000 30-300 30-300 30-300 30-1000 30-1000 30-500 30-300 30-1000 30-1000 30-1000 30-3000 30-3000 30-3000 30-1000 30-1000 30 30 30-1000 30-1000 30-1000 30-3000 30-3000 30-3000 30-1000 30-1000 30 30-300 30-1000 30-1000 30-1000 - - - - - - 16 (y 25 A) 25 (> 25 A) 16 25 25 35 35 35 (y 63 A) 50 (> 63 A) 25 (y 25 A) 35 (> 25 A) 25 35 35 50 50 50 (y 63 A) 70 (> 63 A) y 63 A y 63 A - - - 18 per pole 18 per pole 18 per pole 18 per pole 18 per pole 27 per pole 27 per pole 27 per pole 27 per pole 27 per pole 81 81 81 81 81 81 81 103 103 103 73 73 73 73 73 73 73 81 81 81 7

NG160 Characteristics of NG160 circuit reakers and switch-disconnectors 0 Incomer for modular switchoards PB101686-32 3 and 4 pole circuit reakers and switchdisconnectors specially designed for use upstream of Multi 9 modular devices: reinforcement of reaking capacities of downstream devices y cascading up to 25 ka easy installation in Pragma or Prisma Plus type G enclosures: v standard 45 mm front cut-out v clip-on installation on a DIN rail v reduced depth (82.5 mm). NG160 circuit reaker. NG160 circuit reaker Electrical characteristics as per IEC 60947-2 Rated current (A) In 40 C 160 Rated insulation voltage (V) Ui 800 Rated impulse withstand voltage Uimp 8 (kv) Rated operational voltage (V) Ue AC 50/60 Hz 500 Type of circuit reaker E N H Ultimate reaking capacity Icu AC 220/240 V 25 40 50 (ka rms) 50/60 380/415 V 16 25 36 Hz 440 V 10 16 22 500 V 8 10 15 Service reaking capacity Ics % Icu 75 % Suitaility for isolation Duraility (C-O cycles) mechanical 10000 electrical (In -440 V) 5000 Protection Built-in thermal-magnetic trip unit Ratings In 16 25 32 40 50 63 80 100 125 160 Thermal protection Ir fixed threshold adjustale threshold 0.8 to 1 In Magnetic protection lm 600 600 600 600 600 800 800 1000 1250 1250 NG160NA switch-disconnector Electrical characteristics as per IEC 60947-3 Conventional thermal current (A) Ith 40 C 160 Rated insulation voltage (V) Ui 800 Rated impulse withstand voltage Uimp 8 (kv) Rated operational voltage (V) Ue AC 50/60 Hz 500 Rated operational current Ie AC 50/60 Hz AC22A AC23A 220/240 V 160 160 380/415 V 160 160 440/480 V 160 160 500 V 160 125 Short-circuit lcm (ka peak) 2.1 making capacity min. for switchdisconnector alone max. with protection y upstream circuit reaker 330 Short-time withstand current Icw (A rms) 1 s 1500 3 s 1500 Suitaility for isolation Coordination etween circuit reakers and switch-disconnectors The switch-disconnector must e protected against downstream short-circuits. The choice of the right switch-disconnector therefore depends on coordination with the protective device installed upstream. The tale elow indicates the maximum short-circuit current in karms for which the switch-disconnector is protected y coordination with the circuit reaker located upstream. Important: the switch-disconnector must e protected against overloads. The rating of the switch-disconnector must e greater than or equal to that of the upstream circuit reaker. Upstream protection NR100F NS100 - NS160 NR160F N SX H NG160NA downstream 380-415 V Isc max ka rms 25 36 50 70 Making capacity ka peak 52 75 105 154 440 V Isc max ka rms 20 35 50 65 Making capacity ka peak 42 73 105 143 8

NG160 PD391206-62 Installation and connections Connections Connectors Bare cales from 1.5 to 70 mm² cales Dimensions (mm) W x H x D Width in 9 mm modules NG160 3P 90 x 120 x 82.5 10 4P 120 x 120 x 82.5 14 NG160 3P 210 x 120 x 82.5 24 with Vigi 4P 240 x 120 x 82.5 27 Weight (kg) Device 3P 1.1 4P 1.4 Device + Vigi 3P 2.6 module 4P 2.9 NG160 in modular enclosure. 9

EasyPact Characteristics 0 PB101838-12 EasyPact circuit reakers Numer of poles Rated current (A) In at 40 C PB101840-18 PB101843-24 EZC100 1P EZC100 2P EZC100 3P Rated insulation voltage (V) Ui Rated impulse withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Electrical characteristics as per IEC 60947-2, EN 60947-2, JIS 8201-2-1 Ultimate reaking capacity (ka rms) Icu AC 50/60 Hz 110/130 V 220/230/240 V 380 V 400/415 V 440 V 550 V DC 125 V (1P) 250 V (2P in series) Rated service reaking capacity Ics % Icu 110-400 V 415-550 V Suitaility for isolation Utilisation category Pollution degree Endurance (C-O cycles) Mechanical Electrical In/415 V Electrical characteristics as per NEMA-AB1 Breaking capacity (ka) HIC AC 50/60 Hz 240 V 277/480 V Protection Overload protection Bimetal Instantaneous protection Magnetic Auxiliaries Indication contacts Auxiliary switch AX Alarm switch AL Comined AX + AL AXAL Voltage releases Shunt trip release SHT Undervoltage release UVR Installation Connection Crimp lugs/ars Accessories Box lugs for are cales Rotary handles direct extended Terminal extensions Spreaders Phase arriers Terminal shields Padlocking system DIN rail plate Dimension and weight Dimensions (mm) D x H W Weight (kg) 10

EasyPact 0 EZC100B EZC100F EZC100N EZC100H 3 3 1 3 1 2-3 15, 16, 20, 25, 30, 32, 40, 45, 50, 60, 63 15, 16, 20, 25, 30, 32, 40, 45, 50, 60, 63, 75, 80, 100 15, 16, 20, 25, 30, 32, 40, 45, 50, 60, 63, 75, 80, 100 15, 16, 20, 25, 30, 32, 40, 45, 50, 60, 63, 75, 80, 100 15, 16, 20, 25, 30, 32, 40, 45, 50, 60, 63, 75, 80, 100 690 690 690 690 690 690 6 6 6 6 6 6 550-550 250 415 125 550 250 415 125 15, 16, 20, 25, 30, 32, 40, 45, 50, 60, 63, 75, 80, 100 550 250 10 25 25 25 50 100 10 25 18 25 25 100 (1) 7.5 10 2.5 18 5 30 7.5 10 2.5 15 5 30 5 7.5-10 - 20 2.5 5-5 - 10-5 - 5 5-25 % 50 % 50 % 50 % 50 % 50 % 25 % 50 % 50 % 50 % 50 % 25 % A A A A A A 3 3 3 3 3 3 8 500 8 500 8 500 8 500 8 500 8 500 1 500 1 500 1 500 1 500 1 500 1 500 5 5 10-10 10 - - 10 25 18 100 - - 10 (2) 10 18 (2) 18 (3) fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed - - - - - - - - - - - - - - (3) - - (3) - - - - - - - - - - (3) 60 x 130 60 x 130 60 x 130 60 x 130 60 x 130 60 x 130 75 75 25 75 25 50 (2P), 75 (3P) 0.78 0.78 0.28 0.78 0.28 0.6(2P), 0.78(3P) (1) 50 ka for 2 poles. (2) For 277 V only. (3) For 3 poles only. 11

EasyPact Characteristics 0 PB101847-31 EasyPact circuit reakers Numer of poles Rated current (A) In 40 C PB101854-42 EZC250 3P EZCV250 4P EZC400 3P Rated insulation voltage (V) Ui Rated impulse withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Electrical characteristics as per IEC 60947-2 and EN 60947-2 Electrical characteristics as per JIS C8201-2-1/8201-2-2 Ultimate reaking capacity (ka rms) Icu AC 50/60 Hz 110/130 V 220/230/240 V 380 V 400/415 V 440 V 550 V DC 125 V (1P) 250 V (2P in series) Rated service reaking capacity (ka rms) Ics % Icu Suitaility for isolation Utilisation category Pollution degree Endurance (C-O cycles) Mechanical Electrical In / 415 V Electrical characteristics as per NEMA-AB1 Breaking capacity (ka) HIC AC 50/60 Hz 240 V 277/480 V Protection Overload protection Bimetal Instantaneous protection Magnetic fixed (+ 20 %) Earth-leakage protection Adjustale Sensitivities I n (ma) Time-delay (s) Max reaking time (s) Auxiliaries Indication contacts Auxiliary switch AX Alarm switch AL Comined AX + AL AXAL Earth- Alarm switch ALV Voltage releases Shunt trip release SHT Undervoltage release UVR Installation Connection Crimp lugs / ars Accessories Dimension and weight Dimensions (mm) Box lugs for are cales Rotary handles Terminal extensions Spreaders Phase arriers Terminal shields Rear connections Padlocking system D x H W Direct Extended Weight (kg) 12

EasyPact 0 EZC250F EZC250N EZC250H EZCV250N EZCV250H EZC400N EZC400H 3 3 4 2-3 4 3-4 3-4 3-4 3-4 100, 125, 150, 160, 175, 200, 225, 250 100, 125, 150, 160, 175, 200, 225, 250 63, 80, 100, 125, 150, 160, 175, 200, 225, 250 100, 125, 150, 160, 175, 200, 225, 250 63, 80, 100, 125, 150, 160, 175, 200, 225, 250 63, 80, 100, 125, 150, 160, 175, 200, 225, 250 63, 80, 100, 125, 150, 160, 175, 200, 225, 250 250, 300, 350, 400 690 690 690 690 690 440 440 690 690 6 6 6 6 6 6 6 6 6 550 550 550 550 550 440 440 550 550 250 250 250 250 250 - - 250 250 250, 300, 350, 400 25 50 50 85 85 85 100 85-25 50 50 85 85 85 100 85 100 18 25 25 36 36 25 36 36 100 18 25 25 36 36 25 36 36 50 15 20 20 25 25 20 25 36 50 5 8 8 10 10 - - 18 22 5 5 20 20 30 30 - - - - 20 20 30 30 - - 20 40 50 % 50 % 50 % 50 % 50 % 50 % 50 % 50 % 50 % A A A A A A A A A 3 3 3 3 3 3 3 3 3 10 000 10 000 10 000 10 000 10 000 10 000 10 000 4 000 4 000 5 000 5 000 5 000 5 000 5 000 5 000 5 000 1 000 1 000 25 50 50 85 85 50 85 50 85 15 18 18 25 (1) 25 - - 25 35 fixed fixed fixed fixed fixed fixed fixed fixed fixed 10 In 10 In 10 In 10 In 10 In 10 In 10 In 10 In 10 In - - - - - 100/300/500/ 1000 100/300/500/ 1000 - - - - - - - 0/0.2/0.5/1 0/0.2/0.5/1 - - - - - - - 0.15/0.4/1/2 0.15/0.4/1/2 - - - - - - 60 x 165 60 x 165 68 x 165 60 x 165 68 x 165 68 x 165 68 x 165 103 x 257 103 x 257 105 105 140 105 140 105 (3P) 140 (4P) 1.3 1.3 1.8 1.1 (2P) 1.3 (3P) 1.8 1.6 (3P) 2.1 (4P) 105 (3P) 140 (4P) 1.6 (3P) 2.1 (4P) 140 (3P) 185 (4P) 5 (3P) 7.5 (4P) 140 (3P) 185 (4P) 5 (3P) 7.5 (4P) (1) For 3 poles only. 13

Compact NS Compact NS AC circuit reakers up to 630 A PB101050_33 PB101044_42 Compact NS250H Compact NS630N (1) 2P in 3P case for type N only (2) specific trip units are availale for operational voltages > 525 V (3) NS100N et U u 500 V: Ics = 50 % Icu (4) operational voltage y 500 V Compact circuit reakers Numer of poles Control manual toggle direct or extended rotary handle electric Connections fixed front connection rear connection plug-in (on ase) front connection rear connection withdrawale (on chassis) front connection rear connection Electrical characteristics as per IEC 60947-2 and EN 60947-2 Rated current (A) In 40 C 65 C Rated insulation voltage (V) Ui Rated impulse withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Type of circuit reaker Ultimate reaking capacity (ka rms) lcu AC 220/240 V 50/60 Hz 380/415 V 440 V 500 V 525 V 660/690 V Service reaking capacity (ka rms) lcs % Icu Suitaility for isolation Utilisation category Duraility (C-O cycles) Electrical characteristics as per NEMA AB1 (H.I.C.) Breaking capacity (ka) Electrical characteristics as per UL508 Breaking capacity (ka) mechanical electrical 440 V In/2 In 240 V 480 V 600 V 240 V 480 V 600 V Protection Trip units Overload protection long time Ir (In x ) Short-circuit protection short time lsd (Ir x ) instantaneous Ii (In x ) Earth-fault protection lg (In x ) Zone selective interlocking ZSI Add-on earth-leakage protection add-on Vigi module comination with Vigirex relay Current measurements Additional measurement, indication and control auxiliaries Indication contacts MX shunt and MN undervoltage releases Voltage-presence indicator Current-transformer module and ammeter module Insulation-monitoring module Remote communication y us Device-status indication Device remote operation Transmission of settings Indication and identification of protection devices and alarms Transmission of measured current values Installation Accessories terminal extensions and spreaders terminal shields and interphase arriers escutcheons Dimensions (mm) W x H x D fixed, front connections 2-3P / 4P Weight (kg) fixed, front connections 3P / 4P Source changeover system (see section on source changeover systems) Manual, remote-operated and automatic source changeover systems 14

Compact NS NS100 NS160 NS250 NS400 NS630 2 (1), 3, 4 2 (1), 3, 4 2 (1), 3, 4 3, 4 3, 4 100 160 250 400 630 100 150 220 320 500 750 750 750 750 750 8 8 8 8 8 690 690 690 690 690 500 500 500 500 500 N SX H L N SX H L N SX H L N H L N H L 85 90 100 150 85 90 100 150 85 90 100 150 85 100 150 85 100 150 36 50 70 150 36 50 70 150 36 50 70 150 50 70 150 50 70 150 35 50 65 130 35 50 65 130 35 50 65 130 42 65 130 42 65 130 25 36 50 100 30 36 50 70 30 36 50 70 30 50 100 30 50 70 22 35 35 100 22 35 35 50 22 35 35 50 22 35 100 22 35 50 8 10 10 75 8 10 10 20 8 10 10 20 10 (2) 20 (2) 75 (2) 10 (2) 20 (2) 35 (2) 100 % (3) 100 % 100 % 100 % 100 % (4) A A A A A 50000 40000 20000 15000 15000 50000 40000 20000 12000 8000 30000 20000 10000 6000 4000 N SX H L N SX H L N SX H L N H L N H L 85 90 100 200 85 90 100 200 85 90 100 200 85 100 200 85 100 200 35 50 65 130 35 50 65 130 35 50 65 130 42 65 130 42 65 130 8 20 35 50 20 20 35 50 20 20 35 50 20 35 50 20 35 50 N SX H L N SX H L N SX H L N H L N H L 85 85 85-85 85 85-85 85 85 25 50 65-35 50 65-35 50 65 10 10 10-10 10 10-18 18 18 TM (thermal-magnetic) STR22 (electronic) STR23 (electronic) STR53 (electronic) - - - - - - - - - - - - - - - - - - - 105 x 161 x 86 / 140 x 161 x 86 140 x 255 x 110 / 185 x 255 x 110 2.0 to 2.2 / 2.6 to 2.8 6.2 to 8.1 15

Compact NS Compact NS AC circuit reakers from 630 to 3200 A PB101669R_38 E45178R_68 Compact NS800L Compact NS2000H (1) 65 C with vertical connections. See the temperature derating tales for other types of connections. (2) Ics: 100 % Icu for reaking capacity 440V/500V/660V Ics: 75 % Icu for reaking capacity 220V/380V. Compact circuit reakers Numer of poles Control manual toggle direct or extended rotary handle electric Type of circuit reaker Connections fixed front connection rear connection front connection with are cales withdrawale (on chassis) front connection rear connection Electrical characteristics as per IEC 60947-2 and EN 60947-2 Rated current (A) In 50 C 65 C (1) Rated insulation voltage (V) Ui Rated impulse withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz Type of circuit reaker Ultimate reaking capacity (ka rms) lcu AC 220/240 V 50/60 Hz 380/415 V 440 V 500/525 V 660/690 V Service reaking capacity (ka rms) lcs Value or % Icu manual operation electrical operation Short-time withstand current (ka rms) lcw AC 50/60 Hz 1 s 3 s Integrated instantaneous protection ka peak ±10 % Suitaility for isolation Utilisation category Duraility (C-O cycles) Pollution degree Electrical characteristics as per Nema AB1 Breaking capacity at 60 Hz (ka) mechanical electrical 440 V In/2 In 690 V In/2 In 240 V 480 V 600 V Protection and measurements Interchangeale control units Overload protection long time Ir (In x ) Short-circuit protection short time Isd (Ir x ) instantaneous Ii (In x ) Earth-fault protection lg (In x ) Residual earth-leakage protection I n Zone selective interlocking ZSI Protection of the fourth pole Current measurements Remote communication y us Device-status indication Device remote operation Transmission of settings Indication and identification of protection devices and alarms Transmission of measured current values Additional indication and control auxiliaries Indication contacts Voltage releases MX shunt release/mn undervoltage release Installation Accessories Dimensions fixed devices, front connections (mm) H x W x D Weight fixed devices, front connections (kg) terminal extensions and spreaders terminal shields and interphase arriers escutcheons 3P 4P 3P 4P Source changeover system (see section on "source changeover systems") Manual, remote-operated and automatic source changeover systems 16

Compact NS NS630 NS800 NS1000 NS1250 NS1600 NS1600 NS2000 NS2500 NS3200 3, 4 3, 4 3, 4 3, 4 3, 4 - (except LB) - N H L LB N H L N H N H N H - - - - - - - - - - - - - 630 800 1000 1250 1600 1600 2000 2500 3200 630 800 1000 1250 1510 1550 1900 2500 2970 800 800 800 800 800 8 8 8 8 8 690 690 690 690 690 N H L LB N H L N H N H N H 50 70 150 200 50 70 150 50 70 50 70 85 125 50 70 150 200 50 70 150 50 70 50 70 70 85 50 65 130 200 50 65 130 50 65 50 65 65 85 40 50 100 100 40 50 100 40 50 40 50 65-30 42 25 75 30 42 25 30 42 30 42 65-100 % 75 % 100 % 100 % 100 % 75 % 100 % 100 % 75 % 75 % 50 % 100 % (2) 75 % 75 % 50 % 100 % - 75 % 50 % 100 % 75 % 50 % 75 % 50 % 100 % (2) 75 % 19.2 19.2 7 5 19.2 19.2 7 19.2 19.2 19.2 19.2 - - - - - - 32 32 40 40 - - 40 40-40 40 40 40 130 130 B B A A B B A B B B B B B 10000 10000 10000 10000 5000 6000 6000 4000 4000 6000 6000 4000 5000 5000 3000 5000 5000 3000 3000 5000 5000 3000 4000 2000 2000 4000 4000 3000 3000 4000 4000 3000 3000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 1000 1000 III III III III III N H L LB N H L N H N H N H 50 65 125 200 50 65 125 50 65 50 65 85 125 35 50 100 200 35 50 100 35 50 35 50 65 85 25 50-100 25 50-25 50 25 50 50 - Micrologic 2.0 Micrologic 5.0 Micrologic 2.0 A Micrologic 5.0 A Micrologic 6.0 A Micrologic 7.0 A - - - - - - - - - - - - - - - - - - - - - - - - - 327 x 210 x 147 350 x 420 x 160 327 x 280 x 147 350 x 535 x 160 14 24 18 36-17

Compact NS Compact NS DC circuit-reakers from 100 to 630 A 0 PB100905-36 PB101055-27 PB101048-20 PB101047-14 Compact circuit reaker Numer of poles Electrical characteristics as per IEC 60947-1/ 60947-2 and EN 60947-1 / 60947-2 Rated current at 40 C In (A) Rated insulation voltage Ui (V) Rated impulse withstand voltage Uimp (kv peak) Rated operational voltage Ue (V DC) Type of circuit reaker Ultimate reaking capacity (L/R = 5 ms and L/R = 15 ms) Icu (ka rms) V DC 48-125 V (1P) (1) Service reaking capacity Ics % Icu Rated making capacity Icm % Icu Utilisation category Breaking time (ms) Suitaility for isolation Pollution degree (as per IEC 60664-1) Protection against overcurrents (see "LV circuit reakers and switch-disconnectors direct current 16 to 4000 A" - ABTED205160EN) Trip units Protection Duraility (O/F cycles) Indication and control auxiliaries Auxiliary contacts Voltage release Installation and connections Fixed Plug-in (ase) Withdrawale (chassis) Dimensions and weight Dimensions H x W x D (mm) connected in series Weight (kg) connected in series Mechanical Electrical MX shunt release MN undervoltage release Fixed Fixed (1) Numer of poles taking part in current interruption. Example. The NS100N circuit reaker exists in the following versions: - 1 pole with an Icu of 50 ka, for systems y 250 V - 2 poles with an Icu of 85 ka, for systems y 500 V; 1 pole can e used in a 250 V system. 250 V (1P) (1) 500 V (2P) (1) 750 V (3P) (1) Built-in Interchangeale Overloads Short-circuits 250 V In 250 V In/2 500 V In 500 V In/2 750 V In 750 V In/2 Front connection Rear connection Front connection Rear connection Front connection Rear connection 1P 2P 3P 4P 1P 2P 3P 4P 18

Compact NS NS100 NS160 NS250 NS400 NS630 1 2 3/4 1 2 3/4 3/4 3/4 3/4 100 160 250 400 550 800 800 800 800 800 8 8 8 8 8 250 500 750 250 500 750 750 750 750 N H N H DC N H N H DC DC DC DC 50 85 85 100 100 50 85 85 100 100 100 100 100 50 85 85 100 100 50 85 85 100 100 100 100 100 - - 85 100 100 - - 85 100 100 100 100 100 - - - - 100 - - - - 100 100 100 100 100 % 100 % A < 10 ms III - - - - - - - - - - - - - - - - 10000 5000 5000 1000 10000 2000 5000 1000 10000 2000 5000 1000 10000 2000 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 161 x 35 x 86 - - 161 x 35 x 86 - - - - 161 x 70 x 86 - - 161 x 70 x 86 - - - - 161 x 105 x 86 - - 161 x 105 x 86 255 x 140 x 110 - - 161 x 140 x 86 - - 161 x 140 x 86 225 x 185 x 110 0.7 - - 0.7 - - - - 1.2 - - 1.2 - - - - 1.6 to 1.9 - - 1.6 to 1.9 6.0 - - 2.1 to 2.3 - - 2.1 to 2.3 7.8 19

Masterpact NT and NW Masterpact NT06 to NT16 AC circuit reakers and switch-disconnectors from 630 to 1600 A 0 PB100767-48 Common characteristics Numer of poles 3/4 Rated insulation voltage (V) Ui 1000 Impulse withstand voltage (kv) Uimp 12 Rated operational voltage (V AC 50/60 Hz) Ue 690/1000 Suitaility for isolation IEC 60947-2 Degree of pollution IEC 60664-1 3 Basic sweatchgear Circuit-reaker as per IEC 60947-2 Rated current (A) In at 40 C/50 C (1) Rating of 4th pole (A) Sensor ratings (A) Type of circuit reaker Ultimate reaking capacity (ka rms) Icu 220/415 V V AC 50/60 Hz 440 V 525 V 690 V 1000 V Rated service reaking capacity (ka rms) Ics % Icu Utilisation category Rated short-time withstand current (ka rms) V AC 50/60 Hz Icw 0.5 s 1 s 3 s Integrated instantaneous protection (ka peak ±10 %) Rated making capacity (ka peak) Icm 220/415 V V AC 50/60 Hz 440 V 525 V 690 V 1000 V Break time (ms) etween tripping order and arc extinction Closing time (ms) Circuit-reaker as per NEMA AB1 Breaking capacity (ka) V AC 50/60 Hz 240 V 480 V 600 V (1) 50 C: rear vertical connected. Refer to temperature derating tales for other connection types. (2) See the current-limiting curves in the "additional characteristics" section. (3) SELLIM system. (4) Availale for 480 V NEMA. (5) Suitale for motor control (direct-on-line starting). Switch-disconnector as per IEC 60947-3 and Annex A Type of switch-disconnector Rated making capacity (ka peak) Icm 220 V AC23A/AC3 category V AC 50/60 Hz 440 V 525/690 V 1000 V Rated short-time withstand current (ka rms) Icw 0.5 s AC23A/AC3 category V AC 50/60 Hz 1 s 3 s Ultimate reaking capacity Icu (ka rms) with an external protection relay 690 V Maximum time delay: 350 ms Mechanical and electrical duraility as per IEC 60947-2/3 at In/Ie Service life Mechanical without maintenance C/O cycles x 1000 Type of circuit reaker Rated current In (A) C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC 60947-2 690 V 1000 V Type of circuit reaker or switch-disconnector Rated operationnal current Ie (A) AC23A C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC 60947-3 690V Type of circuit reaker or switch-disconnector Rated operationnal current Ie (A) AC3 (5) Motor power 380/415 V (kw) 440 V (kw) C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC 60947-3 Annex M/IEC 60947-4-1 690 V 20

Masterpact NT and NW Sensor selection Sensor rating (A) 250 (1) 400 630 800 1000 1250 1600 Ir threshold setting(a) 100 to 250 160 to 400 250 to 630 320 to 800 400 to 1000 500 to 1250 640 to 1600 (1) For circuit-reaker NT02, please consult us. NT06 NT08 NT10 NT12 NT16 630 800 1000 1250 1600 630 800 1000 1250 1600 400 to 630 400 to 800 400 to 1000 630 to 1250 800 to 1600 H1 H2 L1 (2) H10 H1 H2 H10 42 50 150-42 50-42 50 130-42 50-42 42 100-42 42-42 42 25-42 42 - - - - 20 - - 20 100 % 100 % B B A B B B B 42 36 10 20 42 36 20 42 36-20 42 36 20 24 20 - - 24 20 - - 90 10 x In (3) - - 90-88 105 330-88 105-88 105 286-88 105-88 88 220-88 88-88 88 52-88 88 - - - - 42 - - 42 25 25 9-25 25 - < 50 < 50 42 50 150-42 50-42 50 100-42 50-42 42 25-42 42 - HA HA10 HA HA10 75-75 - 75-75 - 75-75 - - 42-42 36 20 36 20 36 20 36 20 20 20 20 20 36 36 12.5 H1 H2 L1 H10 H1 H2 L1 H10 H1 H2 L1 H10 H1 H2 H10 H10 H1 H2 630 800 1000 1250 1600 6 6 3-6 6 3-6 6 3-6 6 - - 6 6 3 3 2-3 3 2-3 3 2-3 3 - - 3 3 - - - 0.5 - - - 0.5 - - - 0.5 - - 0.5 0.5 - - H1/H2/HA 630 800 1000 1250 1600 6 6 6 6 6 3 3 3 3 3 H1/H2/HA 500 630 800 1000 1000 y 250 250 to 335 335 to 450 450 to 560 450 to 560 y 300 300 to 400 400 to 500 500 to 630 500 to 630 6-21

Masterpact NT and NW Masterpact NW08 to NW63 AC circuit reakers and switch-disconnectors from 800 to 6300 A 0 PB100768-38 Common characteristics Numer of poles 3/4 Rated insulation voltage (V) Ui 1000/1250 Impulse withstand voltage (kv) Uimp 12 Rated operational voltage (V AC 50/60 Hz) Ue 690/1150 Suitaility for isolation IEC 60947-2 Degree of pollution IEC 60664-1 4 (1000 V) / 3 (1250 V) Basic circuit-reaker Circuit-reaker as per IEC 60947-2 Rated current (A) at 40 C / 50 C (1) Rating of 4th pole (A) Sensor ratings (A) PB100769-70 Type of circuit reaker Ultimate reaking capacity (ka rms) V AC 50/60 Hz Rated service reaking capacity (ka rms) Ics % Icu Utilisation category Rated short-time withstand current (ka rms) V AC 50/60 Hz Icw 1 s 3 s Integrated instantaneous protection (ka peak ±10 %) Rated making capacity (ka peak) V AC 50/60 Hz Break time (ms) etween tripping order and arc extinction Closing time (ms) Circuit-reaker as per NEMA AB1 Breaking capacity (ka) V AC 50/60 Hz Icu Icm 220/415/440 V 525 V 690 V 1150 V 220/415/440 V 525 V 690 V 1150 V 240/480 V 600 V Unprotected circuit-reaker Tripping y shunt trip as per IEC 60947-2 Type of circuit reaker Ultimate reaking capacity (ka rms) V AC 50/60 Hz Icu 220...690 V Rated service reaking capacity (ka rms) Ics % Icu Rated short-time withstand current (ka rms) Icw 1 s 3 s Overload and short-circuit protection External protection relay: short-circuit protection, maximum delay: 350 ms (4) Rated making capacity (ka peak) V AC 50/60 Hz Icm 220...690 V (1) 50 C: rear vertical connected. Refer to temperature derating tales for other connection types. (2) See the current-limiting curves in the "additional characteristics" section. (3) Equipped with a trip unit with a making current of 90 ka peak. (4) External protection must comply with permissile thermal constraints of the circuit reaker (please consult us). No fault-trip indication y the SDE or the reset utton. (5) Availale for 480 V NEMA. (6) Suitale for motor control (direct-on-line starting). Switch-disconnector as per IEC 60947-3 and Annex A Type of switch-disconnector Rated making capacity (ka peak) AC23A/AC3 category V AC 50/60 Hz Rated short-time withstand current (ka rms) AC23A/AC3 category V AC 50/60 Hz Icm Icw 220...690 V 1150 V 0.5 s 1 s 3 s Mechanical and electrical duraility as per IEC 60947-2/3 at In/Ie Service life Mechanical with maintenance C/O cycles x 1000 without maintenance Type of circuit reaker Rated current In (A) C/O cycles x 1000 Electrical without maintenance 440 V (5) IEC 60947-2 690 V 1150 V Type of circuit reaker or switch-disconnector Rated operational current Ie (A) AC23A C/O cycles x 1000 Electrical without maintenance 440 V (5) IEC 60947-3 690 V Type of circuit reaker or switch-disconnector Rated operational current Ie (A) AC3 (6) Motor power 380/415 V (kw) 440 V (5) (kw) 690 V (kw) C/O cycles x 1000 Electrical without maintenance 440/690 V (5) IEC 60947-3 Annex M/IEC 60947-4-1 22

Masterpact NT and NW Sensor selection Sensor rating (A) 250 (1) 400 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 Ir threshold setting(a) 100 160 250 320 400 500 630 800 1000 1250 1600 2000 2500 to 250 to 400 to 630 to 800 to 1000 to 1250 to 1600 to 2000 to 2500 to 3200 to 4000 to 5000 to 6300 (1) For circuit-reaker NW02, please consult us. NW08 NW10 NW12 NW16 NW20 NW25 NW32 NW40 NW40 NW50 NW63 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 400 to 800 400 to 1000 630 to 1250 800 to 1600 1000 to 2000 1250 to 2500 1600 to 3200 2000 to 4000 2000 to 4000 2500 to 5000 3200 to 6300 N1 H1 H2 L1 (2) H10 H1 H2 H3 L1 (2) H10 H1 H2 H3 H10 H1 H2 42 65 100 150-65 100 150 150-65 100 150-100 150 42 65 85 130-65 85 130 130-65 85 130-100 130 42 65 85 100-65 85 100 100-65 85 100-100 100 - - - - 50 - - - - 50 - - - 50 - - 100 % 100 % 100 % 100 % B B B B 42 65 85 30 50 65 85 65 30 50 65 85 65 50 100 100 22 36 50 30 50 36 75 65 30 50 65 75 65 50 100 100 - - 190 80 - - 190 150 80 - - 190 150 - - 270 88 143 220 330-143 220 330 330-143 220 330-220 330 88 143 187 286-143 187 286 286-143 187 286-220 286 88 143 187 220-143 187 220 220-143 187 220-220 220 - - - - 105 - - - - 105 - - - 105 - - 25 25 25 10 25 25 25 25 10 25 25 25 25 25 25 25 < 70 < 70 < 70 < 80 42 65 100 150-65 100 150 150-65 100 150-100 150 42 65 85 100-65 85 100 100-65 85 100-100 100 HA HF (3) HA HF (3) HA HF (3) HA 50 85 50 85 55 85 85 100 % 100 % 100 % 100 % 50 85 50 85 55 85 85 36 50 36 75 55 75 85 105 187 105 187 121 187 187 NW08/NW10/NW12 NW16 NW20 NW25/NW32/NW40 NW40/NW50/NW63 NA HA HF HA10 HA HF HA10 HA HF HA10 HA HF HA10 HA 88 105 187-105 187-105 187-121 187-187 - - - 105 - - 105 - - 105 - - 105-42 50 85 50 50 85 50 50 85 50 55 85 50 85-36 50 50 50 50 50 50 50 50 55 75 50 85 25 20 10 12.5 10 5 N1/H1/H2 L1 H10 H1/H2 H3 L1 H10 H1/H2 H3 H10 H1 H2 800/1000/1250/1600 2000 2500/3200/4000 4000/5000/6300 10 3-8 2 3-5 1.25-1.5 1.5 10 3-6 2 3-2.5 1.25-1.5 1.5 - - 0.5 - - - 0.5 - - 0.5 - - H1/H2/HA/HF H1/H2/H3/HA/HF H1/H2/H3/HA/HF H1/H2/HA 800/1000/1250/1600 2000 2500/3200/4000 4000/5000/6300 10 8 5 1.5 10 6 2.5 1.5 H1/H2/HA/HF H1/H2/H3/HA/HF 800 1000 1250 1600 2000 335 to 450 450 to 560 560 to 670 670 to 900 900 to 1150 400 to 500 500 to 630 500 to 800 800 to 1000 1000 to 1300 y 800 800 to 1000 1000 to 1250 1250 to 1600 1600 to 2000 6 23

Masterpact NT and NW Masterpact NW10 to NW40 DC circuit reakers from 800 to 6300 A 0 E88193-31 PB101129-34 NW10DC 4P. Masterpact circuit reaker Numer of poles Version C or D Version E Electrical characteristics as per IEC 60947-1/ 60947-2 and EN 60947-1 / 60947-2 Rated current at 40 C / 50 C (1) In (A) Rated insulation voltage Ui (V) Rated impulse withstand voltage Uimp (kv peak) Rated operational voltage Ue (V DC) Type of circuit reaker Ultimate reaking capacity L/R = 5 ms Icu (ka) V DC 500 750 900 L/R = 15 ms Icu 500 750 900 L/R = 30 ms Icu 500 750 900 Service reaking capacity Ics % Icu Rated making capacity Icm % Icu Short-time withstand current Icw 1 s Utilisation category Breaking time (ms) Making time (ms) Suitaility for isolation Pollution degree (as per IEC 60664-1) Protection against overcurrents (see "LV circuit reakers and switch-disconnectors direct current 16 to 4000 A" - ABTED205160EN) Trip units Built-in Protection Overloads Short-circuits Duraility (O/F cycles) Mechanical With maintenance Without maintenance Electrical Without maintenance 500 V CC 900 V CC Indication and control auxiliaries Auxiliary contacts Voltage release MX shunt release MN undervoltage release Characteristics of switch-disconnectors as per IEC 60947-3 and EN 60947-3 Type of switch-disconnector Rated making capacity Icm (ka) Rated short-time withstand current Icw (ka) 1 s Installation and connections Connection Drawout 3P RC Horizontal 4P Vertical Fixed 3P RC Horizontal 4P Vertical Dimensions and weight Dimensions H x W x D (mm) connected in series Weight (kg) connected in series (approximate values) (1) 50 C - see the derating tale for the NW40. Drawout Fixed Drawout Fixed 3P 4P 3P 4P 3P 4P 3P 4P 24

Masterpact NT and NW 0 NW10 NW20 NW40 3 3 3 4 4 4 1000 2000 4000 1000 1000 1000 12 12 12 500/900 500/900 500/900 N H N H N H 85 100 85 100 85 100-85 - 85-85 - 85-85 - 85 35 85 35 85 35 85-50 - 50-50 - 35-35 - 35 25 50 25 50 25 50-50 - 50-50 - 25-25 - 25 100 % 100 % 50 85 50 85 50 85 B 30 to 75 < 70 4 - - - - - - 20000 10000 8500 5000 2000-2000 - 2000-1000 HA HA HA - 85-85 - 85-85 - 85-85 - - - - 439 x 441 x 494 439 x 441 x 594 439 x 556 x 494 439 x 556 x 594 352 x 422 x 427 352 x 422 x 527 352 x 537 x 427 352 x 537 x 527 90 to 116 125 to 146 60 to 86 85 to 106 25

Masterpact NT and NW Micrologic control units Overview of functions 0 All Masterpact circuit reakers are equipped with a Micrologic control unit that can e changed on site. Control units are designed to protect Power circuits and loads. Alarms may e programmed for remote indications. Measurements of current, voltage, frequency, power and power quality optimise continuity of service and energy management. Dependaility Integration of protection functions in an ASIC electronic component used in all Micrologic control units guarantees a high degree of reliaility and immunity to conducted or radiated disturances. On Micrologic A, P and H control units, advanced functions are managed y an independent microprocessor. Accessories Certain functions require the addition of Micrologic control unit accessories, descried on "LV circuit reakers and switch-disconnectors direct current 16 to 4000 A" - ABTED205160EN. The rules governing the various possile cominations can e found in the electronic catalogue (E-catalogue) accessile via the Products menu of the www.merlin-gerin.com we site. Micrologic name codes Current protection 2.0 A X Y Z X: type of protection 2 for asic protection 5 for selective protection 6 for selective + earth-fault protection 7 for selective + earth-leakage protection. Y: control-unit generation Identification of the control-unit generation. "0" signifies the first generation. Z: type of measurement A for "ammeter" P for "power meter" H for "harmonic meter". DB101116 Micrologic 2: asic protection Protection: long time + instantaneous Micrologic 5: asic protection DB101117 Protection: long time + short time + instantaneous PB100772-32 DB101117 Micrologic 6: selective + earth-fault protection DB101118 Protection: long time + short time + instantaneous + earth fault up to 3200 A Micrologic 7: selective + earth-leakage protection DB101117 DB101119 Protection: long time + short time + instantaneous + earth leakage up to 3200 A 26

Masterpact NT and NW Measurements and programmale protection A: ammeter I 1, I 2, I 3, I N, I earth-fault, I earth-leakage and maximeter for these measurements fault indications settings in amperes and in seconds. P: A + power meter + programmale protection measurements of V, A, W, VAR, VA, Wh, VARh, VAh, Hz, V peak, A peak, power factor and maximeters and minimeters IDMTL long-time protection, minimum and maximum voltage and frequency, voltage and current imalance, phase sequence, reverse power load shedding and reconnection depending on power or current measurements of interrupted currents, differentiated fault indications, maintenance indications, event histories and time-stamping, etc. H: P + harmonics power quality: fundamentals, distortion, amplitude and phase of harmonics up to the 31st order waveform capture after fault, alarm or on request enhanced alarm programming: thresholds and actions. 2.0 A DB101120 5.0 A 5.0 P 5.0 H DB101121 DB101122 DB101122 6.0 A 6.0 P 6.0 H DB101123 DB101124 DB101124 7.0 A 7.0 P 7.0 H DB101123 DB101124 DB101124 27

Interpact INS Interpact INS40 to 160 switch-disconnectors 0 059202a-50 052168a-50 059203a-38 052164a-38 Interpact INS80 switch-disconnector. Interpact INS40 emergency-off switch-disconnector. Interpact INS160 switch-disconnector. Interpact INS160 emergency-off switch-disconnector. Interpact INS switch-disconnectors Numer of poles Electrical characteristics as defined y IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3 Conventional thermal current (A) Ith at 60 C Conventional thermal current in enclosure Ithe at 60 C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kw) Electrical AC 50/60 Hz 220-240 V 230 V (NEMA) 380-415 V 440 V 480 V (NEMA) 500-525 V 660-690 V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (ka peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit reaker) Short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Suitaility for isolation Duraility (O-F cycles) Mechanical Electrical AC 50/60 Hz 220-240 V 380-415 V 440 V 500 V 690 V Electrical DC 250 V Positive contact indication Visile reak Emergency-off switch disconnector Degree of pollution Upstream protection See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue (1) Suitale for 480 V NEMA. 28

Interpact INS INS40 INS63 INS80 INS100 INS125 INS160 3-4 3-4 3-4 3-4 3-4 3-4 40 63 80 100 125 160 40 63 80 100 125 160 690 690 690 750 750 750 8 8 8 8 8 8 500 500 500 690 690 690 250 250 250 250 250 250 690 690 690 750 750 750 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A 40 40 63 63 80 80 100 100 125 125 160 160 40 40 63 63 80 72 100 100 125 125 160 160 40 40 63 63 80 63 100 100 125 125 160 160 40 32 63 40 80 40 100 100 125 125 160 160 - - - - - - 100 63 125 80 160 100 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A 40 40 63 63 80 80 100 100 125 125 160 160 40 40 63 63 80 80 100 100 125 125 160 160 11 15 22 22 37 45 7,5 15 15 22 37 45 20 30 37 45 55 75 22 30 37 55 55 90 22 30 30 55 75 90 18,5 22 22 55 75 110 - - - 55 75 90 class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % 15 15 15 20 20 20 75 75 75 154 154 154 3000 3000 3000 5500 5500 5500 1730 1730 1730 3175 3175 3175 670 670 670 1230 1230 1230 550 550 550 1000 1000 1000 20000 20000 20000 15000 15000 15000 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 - - - - - - 1500 1500 1500 1500 1500 1500 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 - - - - - - III III III III III III - - - - - - 29

Interpact INS Interpact INS40 to 160 switch-disconnectors 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a ackplate Connection By cales By cales with lugs Flat-facing ars Edgewise ars Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module To are cale connectors Directly to terminals To spreaders To vertical-connection adapters via cale-lug adapters Directly to terminals To spreaders To vertical-connection adapters Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assemly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cale connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-arrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) Approximate weight (kg) Enclosure dimensions for Ithe 3 poles 4 poles 3 poles 4 poles H x W x D (mm) DB105413 30

Interpact INS INS40 INS63 INS80 INS100 INS125 INS160 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.7 < Nm < 1.3 0.7 < Nm < 1.3 0.7 < Nm < 1.3 1.4 < Nm < 2 1.4 < Nm < 2 1.4 < Nm < 2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8 8 8 8 8 8 85 x 90 x 62.5 85 x 90 x 62.5 85 x 90 x 62.5 100 x 135 x 62.5 100 x 135 x 62.5 100 x 135 x 62.5 85 x 90 x 62.5 85 x 90 x 62.5 85 x 90 x 62.5 100 x 135 x 62.5 100 x 135 x 62.5 100 x 135 x 62.5 0.5 0.5 0.5 0.8 0.8 0.8 0.6 0.6 0.6 0.9 0.9 0.9 190 x 115 x 55 190 x 115 x 55 190 x 115 x 55 260 x 160 x 55 260 x 160 x 55 260 x 160 x 55 31

Interpact INS Interpact INS250-100 to 630 switch-disconnectors 0 059488a-54 059487a-54 056652a-41 056648a-41 Interpact INS250 switch-disconnector. Interpact INS250 emergency-off switch-disconnector. Interpact INS400 switch-disconnector. Interpact INS switch-disconnectors Numer of poles Electrical characteristics as defined y IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3 Conventional thermal current (A) Ith at 60 C Conventional thermal current in enclosure Ithe at 60 C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kw) Electrical AC 50/60 Hz 220-240 V 230 V (NEMA) 380-415 V 440 V 480 V (NEMA) 500-525 V 660-690 V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (ka peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit reaker) Short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Suitaility for isolation Duraility (O-F cycles) Mechanical Electrical AC 50/60 Hz 440 V 500 V 690 V Electrical DC 250 V Positive contact indication Visile reak Emergency-off switch disconnector Degree of pollution Upstream protection See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue (1) Suitale for 480 V NEMA. (2) 550 A (DC). Interpact INS400 emergency-off switch-disconnector. 32

Interpact INS INS250-100 INS250-160 INS250-200 INS250 INS320 INS400 INS500 INS630 3-4 3-4 3-4 3-4 3-4 3-4 3-4 3-4 100 160 200 250 320 400 500 630 100 160 200 250 320 400 500 630 (2) 750 750 750 750 750 750 750 750 8 8 8 8 8 8 8 8 690 690 690 690 690 690 690 690 250 250 250 250 250 250 250 250 750 750 750 750 750 750 750 750 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A 100 100 160 160 200 200 250 250 320 320 400 400 500 500 630 630 100 100 160 160 200 200 250 250 320 320 400 400 500 500 630 630 100 100 160 160 200 200 250 250 320 320 400 400 500 500 630 630 100 100 160 160 200 200 250 250 320 320 400 400 500 500 630 630 100 100 160 160 200 200 250 250 320 320 400 400 500 500 630 630 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC23B 100 100 160 160 200 200 250 250 320 320 400 400 500 500 550 550 630 100 100 160 160 200 200 250 250 320 320 400 400 500 500 550 550 630 22 45 55 75 90 110 132 200 22 45 55 75 90 110 150 200 45 75 90 132 160 200 250 315 55 90 110 150 185 220 250 400 55 90 110 150 185 220 250 375 55 110 132 160 220 250 355 400 55 90 160 210 250 400 500 560 class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % 30 30 30 30 50 50 50 50 330 330 330 330 330 330 330 330 8500 8500 8500 8500 20000 20000 20000 20000 4900 4900 4900 4900 11500 11500 11500 11500 2200 2200 2200 2200 4900 4900 4900 4900 1800 1800 1800 1800 4000 4000 4000 4000 15000 15000 15000 15000 10000 10000 10000 10000 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC23A DC23B DC23A DC23B DC23A DC23B DC23A DC23B 1500 1500 1500 1500 1500 1500 1500 1500 1000-1000 - 1000-1000 200 - III III III III III III III III - 33

Interpact INS Interpact INS250-100 to 630 switch-disconnectors 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a ackplate Connection By cales By cales with lugs Flat-facing ars Edgewise ars Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module To are cale connectors Directly to terminals To spreaders To vertical-connection adapters via cale-lug adapters Directly to terminals To spreaders To vertical-connection adapters Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assemly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cale connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-arrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) Approximate weight (kg) Enclosure dimensions for Ithe 3 poles 4 poles 3 poles 4 poles H x W x D (mm) DB105413 34

Interpact INS INS250-100 INS250-160 INS250-200 INS250 INS320 INS400 INS500 INS630 - - - - - - - - - - - - - - 5 < Nm < 6.2 5 < Nm < 6.2 5 < Nm < 6.2 5 < Nm < 6.2 13.5 < Nm < 16.5 13.5 < Nm < 16.5 13.5 < Nm < 16.5 13.5 < Nm < 16.5 - - - - - 15 15 15 15 50 50 50 50 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 2 2 2 2 4.6 4.6 4.6 4.6 2.2 2.2 2.2 2.2 4.9 4.9 4.9 4.9 400 x 300 x 200 400 x 300 x 200 400 x 300 x 200 400 x 300 x 200 600 x 400 x 200 600 x 400 x 200 600 x 400 x 200 600 x 400 x 200 35

Interpact INS Interpact INS630 to 2500 switch-disconnector 0 PB100016a-55 Interpact INS switch-disconnectors Numer of poles Electrical characteristics as defined y IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3 Conventional thermal current (A) Ith at 60 C Conventional thermal current in enclosure Ithe at 60 C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz 220-240 V Interpact INS1600 switch-disconnector. 380-415 V 440-480 V (1) PB100018a-55 500-525 V 660-690 V PB100020a-65 Interpact INS1600 emergency-off switch-disconnector. Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kw) Electrical AC 50/60 Hz 220-240 V 380-400 V 415 V 500-525 V 660-690 V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (ka peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit reaker) Short-time withstand current (A rms) Icw 0.5 s 0.8 s 1 s 3 s 20 s 30 s Suitaility for isolation Duraility (O-F cycles) Mechanical Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V Interpact INS2500 switch-disconnector. Electrical DC 125 V (2P) 250 V (4P) Positive contact indication Visile reak Emergency-off switch disconnector Degree of pollution Upstream protection See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue (1) Suitale for 480 V NEMA. (2) For vertical connection usars only. For horizontal connection usars, see derating charts in the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue. 36

Interpact INS INS630 INS800 INS1000 INS1250 INS1600 INS2000 INS2500 3-4 3-4 3-4 3-4 3-4 3-4 3-4 630 800 1000 1250 1600 (2) 2000 2500 630 800 1000 1250 1600 (2) 2000 2500 1000 1000 1000 1000 1000 1000 1000 12 12 12 12 12 12 12 690 690 690 690 690 690 690 250 250 250 250 250 250 250 800 800 800 800 800 800 800 AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1450 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1450 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 AC22B AC22A 1600 1450 1600 1450 1600 1250 1600 1250 1600 1250 AC23A AC21B AC22B AC23B AC21B AC22B AC23B 1250 2000 2000-2500 2500-1250 2000 2000-2500 2500-1250 2000 2000-2500 2500-1250 2000 2000-2500 2500-1250 2000 2000-2500 2500 - DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21B DC22B DC23B DC21B DC22B DC23B 630/2 630/2 630/2 800/2 800/2 800/2 1000/2 1000/2 1000/2 1250/2 1250/2 1250/2 1600/2 1600/2 1600/2 2000/2 2000/2-2500/2 2500/2-630/4 630/4 630/4 800/4 800/4 800/4 1000/4 1000/4 1000/4 1250/4 1250/4 1250/4 1600/4 1600/4 1600/4 2000/4 2000/4-2500/4 2500/4-250 250 315 400 400 - - 400 400 560 710 710 - - 500 500 630 800 800 - - 560 560 710 900 900 - - 710 710 900 - - - - class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % 75 75 75 75 75 105 105 330 330 330 75 75 105 105 50 50 50 50 50 50 50 42 42 42 42 42 50 50 35 35 35 35 35 50 50 20 20 20 20 20 30 30 10 10 10 10 10 13 13 8 8 8 8 8 11 11 5000 3000 3000 3000 3000 600 600 AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 AC22B AC22A 100 500 100 500 100 500 100 500 100 500 AC23B AC21B AC22B AC23B AC21B AC22B AC23B 500 100 100-100 100-500 100 100-100 100-500 100 100-100 100-500 100 100-100 100-500 100 100-100 100 - DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23B DC21B DC22B DC23B DC21B DC22B DC23B 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 500 500 100 100-100 100-1000 1000 1000 500 500 500 500 500 500 500 500 500 500 500 500 100 100-100 100 - - - III III III III III III III 37

Interpact INS Interpact INS630 to 2500 switch-disconnector 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a ackplate Connection By cales By cales with lugs Flat-facing ars Edgewise ars Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module To are cale connectors Directly to terminals To spreaders To vertical-connection adapters via cale-lug adapters Directly to terminals To spreaders To vertical-connection adapters Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assemly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cale connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-arrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) Approximate weight (kg) Enclosure dimensions for Ithe 3 poles 4 poles 3 poles 4 poles H x W x D (mm) DB105413 38

Interpact INS INS630 INS800 INS1000 INS1250 INS1600 INS2000 INS2500 - - - - - - - - - - - 30 30 30 30 30 60 60 50 50 50 50 50 50 50 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 440 x 347.5 x 227.5 440 x 347.5 x 227.5 300 x 410 x 146.5 300 x 410 x 146.5 300 x 410 x 146.5 300 x 410 x 146.5 300 x 410 x 146.5 440 x 462.5 x 227.5 440 x 462.5 x 227.5 14 14 14 14 14 35 35 18 18 18 18 18 45 45 39

Interpact INV Interpact INV100 to 630 switch-disconnectors 0 056650a-48 056654a-48 059491a-54 Interpact INV250 switch-disconnector. Interpact INV250 emergency-off switch-disconnector. Interpact INV400 Std. Interpact INV switch-disconnectors Numer of poles Electrical characteristics as defined y IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3 Conventional thermal current (A) Ith at 60 C Conventional thermal current in enclosure Ithe at 60 C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kw) Electrical AC 50/60 Hz 220-240 V 230 V (NEMA) 380-415 V 440 V 480 V (NEMA) 500-525 V 660-690 V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (ka peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit reaker) Short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Suitaility for isolation Duraility (O-F cycles) Mechanical Electrical AC 50/60 Hz 440 V 500 V 690 V Electrical DC 250 V Positive contact indication Visile reak Emergency-off switch disconnector Degree of pollution Upstream protection See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue (1) Suitale for 480 V NEMA. (2) 550 A (DC). 059493a-52 Interpact INV400 emergency-off switch-disconnector. 40

Interpact INV INV100 INV160 INV200 INV250 INV320 INV400 INV500 INV630 3-4 3-4 3-4 3-4 3-4 3-4 3-4 3-4 100 160 200 250 320 400 500 630 100 160 200 250 320 400 500 630 (2) 750 750 750 750 750 750 750 750 8 8 8 8 8 8 8 8 690 690 690 690 690 690 690 690 250 250 250 250 250 250 250 250 750 750 750 750 750 750 750 750 AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A/B 100 100 100 160 160 160 200 200 200 250 250 250 320 320 320 400 400 400 500 500 500 630 630 630/630 100 100 100 160 160 160 200 200 200 250 250 250 320 320 320 400 400 400 500 500 500 630 630 630/630 100 100 100 160 160 160 200 200 200 250 250 250 320 320 320 400 400 400 500 500 500 630 630 630/630 100 100 100 160 160 160 200 200 200 250 250 200 320 320 320 400 400 400 500 500 500 630 630 500/630 100 100 100 160 160 160 200 200 200 250 250 200 320 320 320 400 400 400 500 500 500 630 550 500/630 DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A/B 100 100 100 160 160 160 200 200 200 250 250 200 320 320 320 400 400 400 500 500 500 550 550 550/630 100 100 100 160 160 160 200 200 200 250 250 200 320 320 320 400 400 400 500 500 500 550 550 550/630 22 45 55 75 90 110 132 200 22 45 55 75 90 110 150 200 45 75 90 132 160 200 250 315 55 90 110 150 185 220 250 400 55 50 110 150 185 220 250 375 55 110 132 132 220 250 355 400 55 90 160 160 250 400 500 560 class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % 30 30 30 30 50 50 50 50 330 330 330 330 330 330 330 330 8500 8500 8500 8500 20000 20000 20000 20000 4900 4900 4900 4900 11500 11500 11500 11500 2200 2200 2200 2200 4900 4900 4900 4900 1800 1800 1800 1800 4000 4000 4000 4000 15000 15000 15000 15000 10000 10000 10000 10000 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A/B 1500 1500 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/- 1500 1500 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/- 1500 1500 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/200 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A/B 1500 1500 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/200 III III III III III III III III - 41

Interpact INV Interpact INV100 to 630 switch-disconnectors 0 Interpact INV switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a ackplate Connection By cales By cales with lugs Flat-facing ars Edgewise ars Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module To are cale connectors Directly to terminals To spreaders To vertical-connection adapters via cale-lug adapters Directly to terminals To spreaders To vertical-connection adapters Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assemly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cale connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-arrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) Approximate weight (kg) Enclosure dimensions for Ithe 3 poles 4 poles 3 poles 4 poles H x W x D (mm) DB105413 42

Interpact INV INV100 INV160 INV200 INV250 INV320 INV400 INV500 INV630 - - - - - - - - - - - - - - - 5 < Nm < 6.2 5 < Nm < 6.2 5 < Nm < 6.2 5 < Nm < 6.2 13.5 < Nm < 16.5 13.5 < Nm < 16.5 13.5 < Nm < 16.5 13.5 < Nm < 16.5-15 15 15 15 50 50 50 50 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 2 2 2 2 4.6 4.6 4.6 4.6 2.2 2.2 2.2 2.2 4.9 4.9 4.9 4.9 400 x 300 x 200 400 x 300 x 200 400 x 300 x 200 400 x 300 x 200 600 x 400 x 200 600 x 400 x 200 600 x 400 x 200 600 x 400 x 200 43

Interpact INV Interpact INV630 to 2500 switch-disconnectors 0 PB100017a-55 Interpact INV switch-disconnectors Numer of poles Electrical characteristics as defined y IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3 Conventional thermal current (A) Ith at 60 C Conventional thermal current in enclosure Ithe at 60 C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz 220-240 V Interpact INV1600 switch-disconnector. 380-415 V 440-480 V (1) PB100019a-55 500-525 V 660-690 V PB100021a-65 Interpact INV1600 emergency-off switch-disconnector. Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kw) Electrical AC 50/60 Hz 220-240 V 380-400 V 415 V 500-525 V 660-690 V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (ka peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit reaker) Short-time withstand current (A rms) Icw 0.5 s 0.8 s 1 s 3 s 20 s 30 s Suitaility for isolation Duraility (O-F cycles) Mechanical Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V Interpact INV2500 switch-disconnector. Electrical DC 125 V (2P) 250 V (4P) Positive contact indication Visile reak Emergency-off switch disconnector Degree of pollution Upstream protection See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue (1) Suitale for 480 V NEMA. (2) For vertical connection usars only. For horizontal connection usars, see derating charts in the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue. 44

Interpact INV INV630 INV800 INV1000 INV1250 INV1600 INV2000 INV2500 3-4 3-4 3-4 3-4 3-4 3-4 3-4 630 800 1000 1250 1600 (2) 2000 2500 630 800 1000 1250 1600 (2) 2000 2500 1000 1000 1000 1000 1000 1000 1000 12 12 12 12 12 12 12 690 690 690 690 690 690 690 250 250 250 250 250 250 250 800 800 800 800 800 800 800 AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1450 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1450 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 AC22B AC22A 1600 1450 1600 1450 1600 1250 1600 1250 1600 1250 AC23A AC21B AC22B AC23B AC21B AC22B AC23B 1250 2000 2000-2500 2500-1250 2000 2000-2500 2500-1250 2000 2000-2500 2500-1250 2000 2000-2500 2500-1250 2000 2000-2500 2500 - DC21A DC22A DC23A DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23A DC21B DC22B DC23B DC21B DC22B DC23B 630/2 630/2 630/2 800/2 800/2 800/2 1000/2 1000/2 1000/2 1250/2 1250/2 1250/2 1600/2 1600/2 1600/2 2000/2 2000/2-2500/2 2500/2-630/4 630/4 630/4 800/4 800/4 800/4 1000/4 1000/4 1000/4 1250/4 1250/4 1250/4 1600/4 1600/4 1600/4 2000/4 2000/4-2500/4 2500/4-250 250 315 400 400 - - 400 400 560 710 710 - - 500 500 630 800 800 - - 560 560 710 900 900 - - 710 710 900 - - - - class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % 75 75 75 75 75 105 105 330 330 330 75 75 105 105 50 50 50 50 50 50 50 42 42 42 42 42 50 50 35 35 35 35 35 50 50 20 20 20 20 20 30 30 10 10 10 10 10 13 13 8 8 8 8 8 11 11 5000 3000 3000 3000 3000 600 600 AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 AC22B AC22A 100 500 100 500 100 500 100 500 100 500 AC23B AC21B AC22B AC23B AC21B AC22B AC23B 500 100 100-100 100-500 100 100-100 100-500 100 100-100 100-500 100 100-100 100-500 100 100-100 100 - DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21B DC22B DC23B DC21B DC22B DC23B 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 500 500 100 100-100 100-1000 1000 1000 500 500 500 500 500 500 500 500 500 500 500 500 100 100-100 100 - - - III III III III III III III 45

Interpact INV Interpact INV630 to 2500 switch-disconnectors 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a ackplate Connection By cales By cales with lugs Flat-facing ars Edgewise ars Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module To are cale connectors Directly to terminals To spreaders To vertical-connection adapters via cale-lug adapters Directly to terminals To spreaders To vertical-connection adapters Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assemly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cale connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-arrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) Approximate weight (kg) Enclosure dimensions for Ithe 3 poles 4 poles 3 poles 4 poles H x W x D (mm) DB105413 46

Interpact INV INV630 INV800 INV1000 INV1250 INV1600 INV2000 INV2500 - - - - - - - - - - - 30 30 30 30 30 60 60 50 50 50 50 50 50 50 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 440 x 347.5 x 227.5 440 x 347.5 x 227.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 440 x 347.5 x 227.5 440 x 347.5 x 227.5 14 14 14 14 14 35 35 18 18 18 18 18 45 45 47

O OFF ON I O OFF ON I Manual source-changeover sytems Interpact INS and Compact NS 40 A to 630 A 0 Range Interpact Compact Models INS40 to INS80 NS100 to INS160 INS250 to INS630 INV250 to INV630 NS100 to NS250 NS400 to NS630 Rating (A) 40 to 160 100 to 630 100 to 630 Type of device Switch-disconnectors with Switch-disconnectors N/H/L circuit reakers extended handles NA switch-disconnectors Manual source-changeover systems Interlocking via toggles DB101768 DB101545 2 devices side-y-side 3 devices side-y-side Interlocking via rotary handles DB101769 DB101546 DB101547 DB101548 2 devices side-y-side Interlocking via keylocks with captive keys DB101770 DB101549 DB101550 A numer of different devices Interlocking on a ase plate DB101771 DB101551 2 devices side-y-side Complete source-changeover assemlies DB101772 DB101552 2 devices side-y-side 48

push OFF O O OFF O OFF push ON I discharged O push OFF push ON I O push OFF push ON I Manual source-changeover sytems Compact NS and Masterpact NT/NW 630 A to 6300 A0 Range Compact Masterpact Models NS630 to NS1600 NT06 to NT16 NW08 to NW63 Rating (A) 630 to 1600 630 to 1600 800 to 6300 Type of device Manual source-changeover systems Interlocking via extended rotary handles N/H/L circuit reakers NA switch-disconnectors H1/L1 circuit reakers HA switch-disconnectors N1/H1/H2/H3/L1 circuit reakers NA/HA/HF switchdisconnectors DB101769 2 devices side-y-side DB101553 Interlocking via keylocks with captive keys DB101770 DB101554 DB101555 O OFF discharged DB101556 O OFF discharged A numer of different devices Mechanical interlocking using connecting rods DB101773 DB101557 push OFF O push ON I DB101558 DB101559 2 devices one aove the other discharged Mechanical interlocking using cales (1) DB101774 DB101560 DB101561 DB101562 2 or 3 devices one aove the other DB101775 2 or 3 devices side-y-side For this case and other cases, please consult us (1) (2) DB101916 (1) Implemented with NS630 to NS1600 electrically-operated devices only. (2) For source-changeover systems using cales, always respect the installation conditions. 49

O OFF push ON I push OFF O discharged O OFF discharged Remote-operated source-changeover systems Compact NS100/1600 100 A to 1600 A 0 Range Compact Models NS100 to NS630 NS630 to NS1600 Rating (A) 100 to 630 630 to 1600 Type of device Remote-operated source-changeover system Mechanical interlocking on ase plate + electrical interlocking N/H/L circuit reakers NA switch-disconnectors N/H/L circuit reakers NA switch-disconnectors DB101771 DB101563 2 electrically-operated devices side-y-side comined with an electrical interlocking system Mechanical interlocking using connecting rods + electrical interlocking DB101773 DB101557 push OFF O push ON I 2 electrically-operated devices one aove the other comined with an electrical interlocking system Mechanical interlocking using cales + electrical interlocking DB101777 DB101560 2 electrically-operated devices one aove the other comined with an electrical interlocking system DB101776 DB101777 2 electrically-operated devices side-y-side comined with an electrical interlocking system Automatic source-changeover systems Remote-operated source-changeover system comined with an automatic-control system The automatic controller operates the devices depending on external parameters. DB101564 (2) DB101776 BA: Simple controller that manages the changeover function. UA: Controller that also manages engine generator sets. UA150: UA controller with a communication option. (2) For source-changeover systems using cales, always respect the installation conditions. DB101565 BA controller UA and UA150 controller 50

Remote-operated source-changeover systems Masterpact NT/NW 630 A to 6300 A0 Range Masterpact Models NT06 to NT16 NW08 to NW63 Rating (A) 630 to 1600 800 to 6300 Type of device H1/L1 circuit reakers HA switch-disconnectors Remote-operated source-changeover system Mechanical interlocking using connecting rods + electrical interlocking N1/H1/H2/H3/L1 circuit reakers NA/HA/HF switch-disconnectors DB101773 DB101558 DB101559 2 electrically-operated devices side-y-side comined with an electrical interlocking system Mechanical interlocking using cales + electrical interlocking DB101774 DB101561 DB101562 2 or 3 electrically-operated devices one aove the other comined with an electrical interlocking system (1) DB101777 DB101775 2 or 3 electrically-operated devices side-y-side comined with an electrical interlocking system (1) (2) Automatic source-changeover systems Remote-operated source-changeover system comined with an automatic-control system The automatic controller operates the devices depending on external parameters. DB101564 DB101776 BA: Simple controller that manages the changeover function. BA controller UA: Controller that also manages engine generator sets. UA150: UA controller with a communication option. (1) Three devices with Masterpact NW only. (2) For source-changeover systems using cales, always respect the installation conditions. For other cases, please consult us. DB101565 UA and UA150 controller 51

Fupact Fupact INFp32 to INFp800 switch-disconnector fuses 0 056504 056503 056502 059000 INFB32. INFC63. INFD160. INFD400. Fupact INFp switch-disconnector fuses Numer of poles / type of fuse-link 3 poles / 3 fuse-links 4 poles / switched neutral 4 poles / 4 fuse-links Electrical characteristics as defined y IEC 60947-1 / IEC 60947-3 and EN 60947-1 / EN 60947-3 Conventional thermal current (A) In free air Ith at 40 C Maximum fuse power dissipation (W) In enclosure Ithe at 40 C Maximum fuse power dissipation (W) Rated insulation voltage (V) Ui AC 50/60 Hz / DC Rated impulse-withstand voltage (kv) Uimp Rated operational voltage (AC20 and DC20) (V) Ue Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational current (A) Ie AC 50/60 Hz 220/240 V 380/415 V 440/480 V (1) 500/525 V 660/690 V DC 125 V/nr of poles in series 250 V/nr of poles in series 440 V/nr of poles in series 500 V/nr of poles in series 750 V/nr of poles in series Rated operational power (kw) (3) AC 220/240 V (motor power given for direct on-line starting) 380/400 V 415 V 500/525 V 660/690 V Rated duties Uninterrupted duty Intermittent duty Rated short-circuit making capacity (ka peak) Switch-disconnector without fuse (refer to singlephase fuse limitation curves) Icm 415 V 500 V 690 V Rated short-circuit reaking capacity (ka rms) / Rated short-circuit making capacity (ka peak) (4) Icn / Icm 415 V (BS) 500 V (DIN) 690 V (DIN) Rated short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Endurance (category A) (CO cycles) Mechanical Elec. AC AC22A 500 V AC22A 690 V AC23A 500 V AC23A 690 V Suitaility for isolation Positive contact indication Pollution degree Control Direct front rotary handle Extended front rotary handle Extended lateral rotary handle Locking y padlocks Operating torque (typical for 3 poles switch-disconnector fuses) (Nm) Indication auxiliaries Auxiliary contacts Blown-fuse indicator Fuse monitor Auxiliary contact test position (1) Suitale for 480 V NEMA. (2) AC23B. (3) Some fuse-links limit these values. Motor starting current must e considered separately. (4) Switch-disconnector comined with fuses. (5) Only for NFC fuse-links. (6) Only for DIN fuse-links. 52

Fupact 0 INFp32 INFD40 INFp63 INFB100 INFC125 INFp160 INFp250 INFp400 INFp630 INFp800 NFC-BS DIN NFC-DIN-BS BS NFC DIN-BS DIN-BS DIN-BS DIN-BS DIN-BS NFC-BS DIN NFC-DIN-BS BS NFC DIN-BS DIN-BS DIN-BS DIN-BS DIN-BS NFC - NFC-DIN - NFC DIN DIN DIN DIN DIN 32 40 63 100 125 160 250 400 630 800 3.5 4.5 7.5 12 12 12 32 45 60 65 32 40 63 100 125 160 135 250 230 400 360 600 570 720 3.5 4.5 7.5 12 12 10 12 23 27 34 37 45 50 55 750 750 750 750 750 750 750 750 750 750 8 8 8 8 8 8 8 8 8 8 690 690 690 690 690 690 690 690 690 690 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A 32 32 40 40 63 63 100 100 125 125 160 160 250 250 400 400 630 630 800 720 32 32 40 40 63 63 100 100 125 125 160 160 250 250 400 400 630 630 800 720 32 32 40 40 63 63 100 100 125 125 160 160 250 250 400 400 630 630 800 720 32 32 40 40 63 63 100 100 125 125 160 160 250 250 400 400 630 630 800 720 32 32 40 40 63 63 (2) 100 100 (2) 125 125 (2) 160 160 (2) 250 250 400 400 630 630 800 720 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A 32/2 32/2 40/2 40/2 63/3 63/3 100/2 100/2 125/2 125/2 160/2 160/2 250/2 250/2 400/2 400/2 630/2 630/2 800/2 800/2 32/4 32/4 40/4 40/4 63/3 63/3 100/2 100/2 125/2 125/2 160/2 160/2 250/2 250/2 400/2 400/2 630/2 630/2 800/2 800/2 32/4 32/4 40/4 40/4 63/3 63/3 100/2 100/2 125/2 125/2 160/2 160/2 250/2 250/2 400/2 400/2 630/2 630/2 800/2 800/2 - - - - - - 100/4 100/4 100/4 100/4 100/4 100/4 250/3 250/3 400/3 400/3 630/3 630/3 800/3 800/3 - - - - - 250/3 250/3 400/3 400/3 630/3 630/3 800/3 800/3 8 11 18.5 30 37 45 70 110 180 200 14 18.5 30 45 60 80 132 210 315 350 15 18.5 30 55 60 90 140 230 340 380 18 22 37 60 80 110 170 280 400 470 25 30 60 90 110 132 230 330 540 600 class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % class 120-60 % 9 9 17 22 22 22 40 40 75 75 7.5 7.5 17 22 22 22 40 40 75 75 6 6 13 15 15 15 35 35 60 60 80/176 80/176 80/176 80/176 80/176 80/176 80/176 80/176 80/176 80/176 100/220 100/220 100/220 100/220 100/220 100/220 100/220 100/220 100/220 100/220 50/105 50/105 50/105 50/105 50/105 50/105 50/105 50/105 50/105 50/105 1000 1000 2500 5000 5000 5000 8000 10000 16000 16000 570 570 1440 2900 2900 2900 4650 5800 9250 9250 220 220 560 1150 1150 1150 1800 2250 3600 3600 180 180 460 950 950 950 1500 1850 2950 2950 10000 10000 10000 10000 10000 10000 8000 8000 5000 5000 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 yes yes yes yes yes yes yes yes yes yes III III III III III III III III III III - - - 3 3 4 8 8 8 22 22 28 28 (5) - (5) - - (6) (6) (6) (6) (standard) (standard) (standard) (standard) (standard) (standard) (optional) (optional) (optional) (optional) 53

Fupact Fupact INFp32 to INFp800 switch-disconnector fuses 0 Fupact INFp switch-disconnector fuses Type of fuse-link NFC 10 x 38 14 x 51 22 x 58 DIN (NH) NH000 NH00 NH0,1 NH0,1,2 NH3 BS (fixing centres in mm) (3) A1 (44,5) F1 A2 (73,0) A3 (73,0) A4 (93,7) B1 (111) B2 (111) B3 (111) B4 (111) C1 (133) C2 (133) C3 (133) Installation and connection Fixed front connection Terminal tightening torque (Nm) Fuse-link olts tightening torque (Nm) Installation and connection accessories Bare-cale connectors Terminals Neutral link Terminal shields Dimensions and weight Overall dimensions H x W x D (mm) 3P 4P Approximate weight without fuses (kg) 3P 4P Enclosure dimensions for Ithe H x W x D (mm) Temperature derating (4) (5) "Vertical mounting" fuse-links in vertical position "Horizontal mounting" fuse-links in horizontal position (1) Maximum fuse ody diameter : Ø32 mm. (2) Maximum fuse ody diameter : Ø55 mm. (3) A: fuse-link with centre olted tags. B: fuse-link with offset olted tags. (4) Derating data is ased on: - the maximum rating for fuse-links intended for the device, - maximum heat loss. (5) For installation on a ceiling, derate an additional 10 %. Ith (A) 40 45 50 55 60 65 70 Ith (A) 35 40 45 50 55 60 65 70 54

Fupact INFp32 INFD40 INFp63 INFB100 INFC125 INFp160 INFp250 INFp400 INFp630 INFp800 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - (1) - (1) - - - - - - - - - - - - - - - - - - - - - - - - - - (2) - - - - - - - - 2 2 3.5 15-22 15-22 15-22 30-44 30-44 50-75 50-75 2 2 2 M5: 3.5 M8: 5 - M5: 3.5 M8: 5 15 15 40 40 (standard) (standard) (standard) (optional) (optional) (optional) (optional) (optional) (optional) (optional) - - - - 97 x 106 x 105 97 x 106 x 133 100 x 143 x 128 140 x 180 x 130 140 x 180 x 130 140 x 180 x 130 162 x 278 x 199 180 x 302 x 206 232 x 378 x 234 232 x 408 x 234 97 x 142 x 105 97 x 142 x 133 100 x 188 x 128 140 x 215 x 130 140 x 215 x 130 140 x 215 x 130 162 x 340 x 199 180 x 372 x 206 232 x 458 x 234 232 x 498 x 234 0.7 0.7 1.3 1.5 1.5 1.5 6.9 7.8 15.5 17 0.9 0.9 1.6 1.8 1.8 1.8 7.9 8.8 19 21 300x350x200 600 x 350 x 300 / 500 x 400 x 250 600 x 700 x 300 / 800 x 600 x 270 NFC-BS DIN NFC-DIN-BS BS NFC DIN-BS DIN-BS DIN-BS DIN-BS DIN-BS 32 40 63 100 125 160 250 400 630 800 30.4 38 60 95 119 152 237 380 600 760 28.8 36 56.7 90 113 144 225 360 567 720 27.2 34 53.6 85 106 136 212 340 536 680 25.6 32 50.4 80 100 128 200 320 504 640 25 30 47.2 75 94 120 187 300 474 600 24.4 28 44 70 88 112 175 280 441 560 31 38 61 96 121 156 242 386 610 772 29.5 36 58 92 115 148 230 368 580 736 28 34 55 87 109 140 218 350 550 700 26.5 32 52.2 83 103 133 207 331 522 662 25 30 49.3 78 97 126 195 313 493 625 23.5 28 46.4 74 92 118 184 295 464 588 22 26 43 69 86 111 172 277 434 552 20.5 24 40 65 81 103 161 268 406 514 55

Fupact Fupact ISFT100 to ISFT630 fuse-switch disconnectors 0 62193 62194 62195 ISFT100. ISFT160. ISFT630. Fupact ISFT fuse-switch disconnectors Numer of poles / type of fuse-link IEC 60269-2-1 Section 1 Electrical characteristics as defined y IEC 60947-1 / IEC 60947-3 and EN 60947-1 / EN 60947-3 Conventional thermal current (A) In free air Ith at 40 C Maximum fuse power dissipation (W) In enclosure Ithe at 40 C Maximum fuse power dissipation (W) Rated insulation voltage (V) Ui AC 50/60 Hz / DC Rated impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage (AC20 and DC20) (V) Ue Rated operational current (A) Ie AC 50/60 Hz 220/240 V 380/415 V 440/480 V (2) 500 V 660/690 V DC/poles in series 125 V /Nr of poles 220 V /Nr of poles 440 V /Nr of poles Rated duties Uninterrupted duty Rated short-circuit reaking capacity (ka rms) / Rated short-circuit making capacity (ka peak)/ In fuse-link (A) (3) Endurance (category B) (CO cycles) Icn/Icm/In fuse-link Mechanical Electrical AC Suitaility for isolation Visile reak Pollution degree Control Direct front rotary handle (operator-dependent opening and closing) Locking Padlocks Lead seal Indication auxiliary Auxiliary contacts Blown-fuse indicator Installation and connection accessories Mounting position Horizontal Vertical Bare-cale connectors Other connectors For are Cu/Al cales For flexile ars Distriution connector Lugs for copper cales Com usars Insulated com covers Incoming connector for com usars Terminal shields Dimensions and weight Overall dimensions H x W x D (mm) 3P Approximate weight without fuse-links (kg) 3P (1) With 95 mm 2 connector. (2) Suitale for 480 V NEMA. (3) Fuse-switch disconnector with fuse-links. 415 V 500 V 690 V AC22B 415 V AC21B 690 V 56