Compact NR630. NR100F to NR630F

Similar documents
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

C1251N DC and C1251N 1000 V

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

Compact Merlin Gerin 80 to 3200 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

DPX moulded case circuit breakers

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

Circuit protection and control devices 0.5 to 6300 A

Wall mounted switchgear

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX 1600 Electronic release

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

DPX 630 Electronic release

DPX earth leakage DPX 3 -I earth leakage

DPX Magnetic only

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

3 - Protection components Motor circuit-breakers

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

cor Long Run Experience

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

C60H-DC C curve. Catalogue numbers

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

DPX Electronic + earth leakage

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

DMX 3 -I 2500 switch disconnectors

Low voltage. EasyPact EZC. Moulded-case circuit breakers from 15 to 630 A. Catalogue 2013

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Thermal magnetic and trip-free switches

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

D509E. Manual Motor - Starters

Vistop TM isolating switches 63 to 160A

Compact NSX100 to 630

01 Spectra Plus - Introduction

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DX³ 4-pole RCBO 6000 A/10 ka

MOULDED CASE CIRCUIT BREAKERS BC160N

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DX³ RCCBs - ID 4P up to 100 A

Protection components

NS Feeder pillar up to 3200A

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary

Phase + Neutral, neutral on left side

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

MANUALLY OPERATED CHANGEOVER SWITCHES

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

Moulded case circuit breakers

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

Compact NS. Installation recommendations

Phase + Neutral, neutral on right side


Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Moulded Case Circuit Breakers

Low voltage electrical distribution. Compact NS. Circuit breakers and switch-disconnectors from 630 to 1600 A. User manual 10/2017


DRX 250 B/N/H Circuit breaker (not adjustable)

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

Btdin RCBO 6000A up to 63A (2P)

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

WORKSHOP SPECIFICATIONS

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

SIRCO M and MV Universal load break switches from 16 to 160 A

TX³ RCCBs 2P up to 100 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

DRX 125 Circuit breaker (not adjustable)

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Selection Guide Motor Control Device Solutions

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

DRX 100 B/N/H Circuit breaker (not adjustable)

Low voltage moulded case circuit breaker EB2

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

3VT Kompaktleistungsschalter bis 630A

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Short-circuit current limiter S800-SCL-SR

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

GE Consumer & Industrial Power Protection. Record SL. Moulded Case Circuit Breakers Standard Line. GE Imagination at work

(1,5 modules per pole)

(p. 47) (p. 155) (p. 155)

MCset kv Medium voltage equipment

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

Cat N 3. OVERALL DIMENSIONS

Intelligent Choice for Prestigious Buildings

Technical data for manual motor starters Type MS325

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Transcription:

Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS range, the Compact NR range offers the necessary basic characteristics at a more economical price. t offers end-users lasting safety gether with unsurpassed energy availability and convenient operational features: b compliance with most standards and certifications worldwide b service breaking capacity cs = 75 % cu (according EC 60947-2) b inherent discrimination of protection devices b suitability for isolation with positive break indication. 045345S-32 Compact NR250. 048286S-38 Compact NR630. General characteristics Compliance with standards nternational EC 60947-1 5 Europe EN 60947 Germany VDE 0660 France NF EN 60947 Great Britain BS EN 60947 taly CE EN 60947 Applications For the protection of distribution systems, Compact NR circuit breakers may be equipped with either thermalmagnetic or electronic units, the latter offering higher accuracy and additional settings. Suitability for isolation and safety of personnel All Compact circuit breakers are suitable for isolation as defined in EC standard 60947-2. The operating handle cannot indicate the "off" position unless the contacts are actually open. Fitting a rotary handle or a mor mechanism does not alter the reliability of the position indication system. All Compact circuit breakers have a Class front insulation as per standards EC/EN 60664-1 and NF C 15100. For protection against direct contact with live parts, Compact circuit breakers may be installed through the front panel of Class switchboards. Degree of pollution The circuit breakers are capable of operating in the most severe industrial environments. They comply with pollution degree 3 protection as defined by EC/EN 60664-1 and EC/EN 60947-1 applicable low voltage switchgear. Tropicalisation Compact NR circuit breakers have successfully passed the tests defined by the following standards: EC/EN 60068-2-1: dry cold (-55 C) EC/EN 60068-2-2: dry heat (+85 C) EC/EN 60068-2-30: damp heat (95 % relative humidity at 55 C) EC/EN 60068-2-52: salt mist (severity level 2). Environmental protection Compact NR circuit breakers take in account important concerns for environmental protection. Most components are recyclable. Degrees of protection As per standards EC/EN 60529 (P degree of protection) and EN 50102 (K degree of protection against external mechanical impacts): b bare circuit breaker with terminal shields: v with ggle or direct rotary handle: P40 and K07 b circuit breaker installed in a switchboard: v with ggle or direct rotary handle: P40 and K07 v with extended rotary handle: P55 and K08. Accessories b Direct or extended rotary handles. b Padlocking or keylocking systems. b Status indication auxiliary contacts (/, ped, fault, earth-fault) b Undervoltage or shunt auxiliary releases b Overload indication (on electronic units).

Characteristics Electrical characteristics NR100 NR160 NR250 NR400 NR630 According EC 60947-2 and EN 60947-2 Number of poles 3, 4 3, 4 3, 4 3, 4 3, 4 Rated current (A) n 40 C 100 160 250 400 630 Rated nsulation voltage (V) Ui 690 690 690 690 690 Rated impulse withstand voltage (kv) Uimp 6 6 6 6 6 Rated operational voltage (V) Ue AC 50/60 Hz 500 500 500 500 500 Type of circuit breaker F F F F F Ultimate breaking capacity (ka rms) cu AC 50/60 Hz 220/240 V 35 35 35 40 40 380/415 V 25 25 25 36 36 440 V 20 20 20 30 30 500 V 15 15 15 25 25 Service breaking capacity cs (% cu) 75 % 75 % 75 % 75 % 75 % Durability (C-O cycles) 415 V / n 10000 10000 6000 3500 3000 Ambient temperatures Operation temperature -25 C +70 C Commissioning temperature -25 C +70 C Srage temperature -25 C +85 C Trip units Thermal magnetic units Ratings (A) 40 C n 16 25 32 40 50 63 80 100 125 160 200 250 Tripping thresholds (A) Thermal r Adjustable 0.8 1 x n Standard magnetic (TM-D) m Fixed Adjustable NR100 190 300 400 500 500 500 640 800 - - - NR160/250 190 300 400 500 500 500 1000 1250 1250 1250 5... 10 x n Low magnetic (TM-G) m Fixed 63 80-80 - 125 - - - - - - Electronic units (NR100/160/250) STR22SE/STR22GE STR22SE OSN Ratings (A) 40/60 C n 40 80 (1) 100 160 250 160 250 Tripping thresholds (A) Long-time r Adjustable (48 settings) Adjustable (48 settings) 0.4 1 x n 0.25 0.63 x n Tripping time at 1.5 r (s) Fixed Fixed STR22SE: 90 180 - STR22GE: 12...15 90 180 Short-time sd Adjustable (8 settings) Adjustable (8 settings) 2 10 x r 2 10 x r nstantaneous i Fixed Fixed u 11 x n u 7 n Time delay (ms) Short-time Fixed Fixed Overload indication 2 thresholds 2 thresholds 95 %, 105 % x r 95 %, 105 % x r Electronic units (NR400/630) STR23SE STR23SE OSN STR53UE Tripping thresholds (A) Long-time r Adjustable (48 settings) Adjustable (48 settings) Adjustable (48 settings) 0.4 1 x n 0.25 0.63 x n 0.4 1 x n Tripping time at 1.5 r (s) Fixed Fixed Adjustable (5 settings) 90 180 90 180 8 15, 34 50, 69 100, 138 200, 277 400 Short-time sd Adjustable (8 settings) Adjustable (8 settings) Adjustable (8 settings) 2 10 x r 2 10 x r 1.5 10 x r nstantaneous i Fixed Fixed Adjustable (8 settings) u 11 x n u 7 x n 1.5 11 x n Time delay (ms) Short-time Fixed Fixed Adjustable (4 settings with or without l 2 t constant) Overload indication 2 thresholds 2 thresholds 2 thresholds 95 %, 105 % x r 95 %, 105 % x r 95 %, 105 % x r (1) SE only. Protection discrimination The Compact NR range provides, as standard, discrimination between two circuit breakers installed in series. n this way, Compact NS offers unsurpassed continuity of service in the event of a fault. The table below shows some circuit breaker combinations featuring, as standard, tal discrimination between two circuit breakers. Upstream breaker NR100 NR160 NR250 NR400 NR630 Downstream breaker C60 T T T T NR100 T T T NR160 T T NR250 T T: tal discrimination. 2

Earth fault protection Add-on Vigi earth-fault protection module Vigi MH (NR100-250F) Vigi MB (NR400-630F) Sensitivity n (A) Adjustable 0.03-0.3-1 - 3-10 Adjustable 0.3-1 - 3-10 - 30 Time delay (ms) Adjustable 0-60 - 150-310 Adjustable 0-60 - 150-310 Rated voltage 50/60 Hz min./max. 200/400 V 440/550 V 200/400 V 440/550 V Dimensions Dimensions 2 poles or 3 poles 4 poles DB103731 DB103732 DB103733 (a) Short terminal shields. (b) Long terminal shields (available for spreaders on NR400 630, pitch 52.5: L1 = 157.5 mm, L2 = 210 mm). (c) nterphase barriers. Mounting On backplate On rails On DN rail with 3 poles 4 poles 3 poles 4 poles adapter plate DB103734 DB103735 DB103744 DB103745 DB103746 nstallation and connection DB103747 Users can easily adapt Compact NR circuit breakers for bare cable connection or rear connection. Connection of fixed front-connected circuit breakers NR100/160/250 NR400/630 Without spreader With spreader Bars or cables with lugs Pitch (mm) 35 45 52.5 or 70 L (mm) y 25 y 32 y 40 d (mm) y 10 y 15 y 20 Screws M6 (NR100) M10 M12 M8 (NR160/250) Bare cables Number of cables 1 1 2 L (mm) 20 20 30/60 S (mm 2 ) Min. 1.5 35 2 x 85 Max. 95 (NR100/160) 300 2 x 240 185 (NR250) 3

Dimensions (cont.) nstallation and connection (cont.) DB103748 Rear-connected circuit breaker. Front-panel cuuts Fixed circuit breaker Cuut A Cuut B Cuut C DB103736 DB103737 DB103738 DB103739 With escutcheon With ggle cover Note: door cuut dimensions are given for a device position in the enclosure where u 100 + (h x 5) with respect the door hinge. DB103743 DB103740 DB103741 DB103742 Dimensions (mm) Type C C1 C2 C3 C6 C7 C20 C21 G G1 G4 NR100/160/250 29 76 54 108 43 104 34 86 62.5 125 70 NR400/630 41.5 116 92.5 184 56.5 146 46.5 126 100 200 113.5 Type G5 G47 G48 G49 G50 G51 H H1 H2 H3 H4 NR100/160/250 140 95 75 13.5 23 17.5 80.5 161 94 188 160.5 NR400/630 227 - - - - - 127.5 255 142.5 285 240 Type H5 H6 H7 K K1 K2 L L1 L2 P1 P2 NR100/160/250 321 178.5 357 17.5 35 70 52.5 105 140 81 86 NR400/630 480 237 474 22.5 45 90 70 140 185 95.5 110 Type P4 P5 P6 R R1 R2 R4 R5 R6 R7 R12 NR100/160/250 111 (1) 83 88 14.5 29 54 108 143 29 58 43 NR400/630 168 107 112 31.5 63 71.5 143 188 46.5 93 63 (1) P4 = 126 mm for Compact NR250. Type R13 ØT ØT4 U NR100/160/250 86 6 22 y 32 NR400/630 126 6 32 y 32 4

.85.9.8.95.7.98.63 1 xn r test r.8.95.7.98.63 1 xn p u s h push alarm 105 r m.9.93 4 5.63.8.88.95 3 6.85.98 2 8.5 1.8 1 1.5 10 x n x o x r o m 4 5 3 6 2 8 1.5 10 xr push alarm 90 m test r m m 4 5 3 6 2 8 1.5 10 xr r m Catalogue numbers NR100F NR630F: complete fixed/fc device Compact NR100/160/250F With thermal-magnetic unit TM-D E21284 Compact NR400/630F With electronic unit STR23SE DB101985.85.9 Compact NR100F (25 ka at 380/415 V) Rating 3P 3d 4P 3d 4P 4d TM16D 29069 29139 29199 TM25D 29068 29138 29198 TM32D 29067 29137 29197 TM40D 29066 29136 29196 TM50D 29065 29135 29195 TM63D 29064 29134 29194 TM80D 29063 29133 29193 TM100D 29062 29132 29192 Compact NR160F (25 ka at 380/415 V) Rating 3P 3d 4P 3d 4P 4d TM80D 30763 30753 30758 TM100D 30762 30752 30757 TM125D 30761 30751 30756 TM160D 30760 30750 30755 Compact NR250F (25 ka at 380/415 V) Rating 3P 3d 4P 3d 4P 4d TM125D 31763 31768 31778 TM160D 31762 31767 31777 TM200D 31761 31766 31776 TM250D 31760 31765 31775 3P 3d 4P 3d, 4d, 3d + N/2 Compact NR400F (36 ka at 380/415 V) 32740 32741 Compact NR630F (36 ka at 380/415 V) 32940 32941 STR 23 SE 90 NR100F NR630F: fixed/fc device based on separate components Compact NR100 NR630F Basic frame DB101958 3P 4P NR100F 29001 29002 NR160F 30401 30402 NR250F 31401 31412 NR400F 32873 32874 NR630F 32891 32892 + Trip unit DB101959 105 %r 50/60Hz r STR 22 DE (1) For NR100. (2) For NR160/250. Standard protection: unit TM-D for NR100-NR250 Rating 3P 3d 4P 3d 4P 4d 4P 3d + N/2 TM16D 29035 29045 29055 TM25D 29034 29044 29054 TM32D 29037 29047 29057 TM40D 29033 29043 29053 TM50D 29036 29046 29056 TM63D 29032 29042 29052 TM80D (1) 29031 29041 29051 29061 TM100D (1) 29030 29040 29050 29060 TM80D (2) 30433 30443 30453 30463 TM100D (2) 30432 30442 30452 30462 TM125D 30431 30441 30451 30461 TM160D (3) 30430 30440 30450 30460 TM160D (4) 31432 31442 31452 31462 TM200D 31431 31441 31451 31461 TM250D 31430 31440 31450 31460 (3) For NR160. (4) For NR250. 5

Catalogue numbers (cont.) NR100F NR630F: fixed/fc device based on separate components (cont.) + Trip unit (cont.) Standard protection: electronic unit for NR100-NR250 for NR400-NR630 Rating 3P 3d 4P 3d, 4d, 3d + N/2 Rating (U y 525 V) 3P, 4P 3d, 4d, 3d + N/2 STR22SE - 40 A 29072 29082 STR23SE 32420 STR22SE - 80 A (1) 30471 30481 STR53UE F 32424 STR22SE - 100 A 29070 29080 STR53UE FT 32425 STR22SE - 160 A 30470 30480 STR53UE F 32426 STR22SE - 250 A 31470 31480 STR53UE FT (2) 32429 Standard protection with oversized neutral: electronic unit SE OSN for NR100-NR250 for NR400-NR630 Rating 4P 3d, 3d + 1,6N Rating (U y 525 V) 4P 3d, 3d + 1,6N STR22SE OSN 160 A - 3 x φ 100 A (1) 30466 STR23SE OSN 32443 STR22SE OSN 250 A - 3 x φ 160 A (3) 31481 Type G protection: unit TM-G for NR100-NR250 Rating 3P 3d 4P 4d TM16G 29155 29165 TM25G 29154 29164 TM40G 29153 29163 TM63G 29152 29162 Type G protection: electronic unit GE for NR100-NR250 Rating 3P 3d 4P 3d, 4d, 3d + N/2 STR22GE - 40 A 29076 29086 STR22GE - 100 A 29075 29085 STR22GE - 160 A 30475 30485 STR22GE - 250 A 31475 31485 STR53UE options COM wiring 32441 ZS wiring 32442 + Vigi module DB101961 DB101957 For NR100-250 3P 4P ME type for NR100/160 (220 440 V) 29212 29213 MH type for NR100/160 (220 440 V) 29210 29211 for NR250 (220 440 V) 31535 31536 for NR100/160 (440 550 V) 29215 29216 for NR250 (440 550 V) 31533 31534 Connection for a 4P Vigi on a 3P breaker 29214 For NR400-630 3P 4P Type MB 200 440 V 32455 32456 440 550 V 32453 32454 Connection for a 4P Vigi on a 3P breaker 32457 External CT for earth-fault protection T (NR400/NR630) For earth fault protection (T) of STR53UE FT nstallation on outgoing neutral conducr outside the circuit-breaker 400 A 36952 630 A 32440 (1) For NR160/250. (2) For external neutral CT: allows the connection of an external neutral CT for 3P breakers equipped with "earth fault" protection (T). (3) For NR250. E28398 6

Catalogue numbers (cont.) Accessories Connection accessories (Cu or Al) NR100-250F NR400-630F Rear connections E18579 Bare cable connecrs E18572 E18598 E22040 2 short 29235 32475 2 long 29236 32476 Snap-on, for cable Steel: 1.5 95 mm 2 ; y 160 A Set of 3 29242 Set of 4 29243 Aluminium: 25 95 mm 2 ; y 250 A Set of 3 29227 Set of 4 29228 Aluminium: 120 185 mm 2 ; y 250 A Set of 3 29259 Set of 4 29260 Voltage plug for 185 mm 2 bare cable connecr Set of 2 29348 Clips for bare-cable connecr Set of 10 29241 Distribution connecrs for six 1.5 35 mm 2 cables with interphase barriers Set of 3 29248 Set of 4 29249 For 1 cable from 35 300 mm 2 Set of 3 32479 Set of 4 32480 For 2 cable from 35 240 mm 2 Set of 3 32481 Set of 4 32482 Voltage measurement input for bare cable connecr Set of 2 29348 Crimp lugs for copper cable For cable 120 mm 2 for NR100-250F, 240 mm 2 for NR400-630F Set of 3 29252 32500 Set of 4 29256 32501 For cable 150 mm 2 for NR100-250F, 300 mm 2 for NR400-630F Set of 3 29253 32502 Set of 4 29257 32503 For cable 185 mm 2 Set of 3 29254 Set of 4 29258 Supplied with 2 (or 3) interphase barriers Crimp lugs for aluminium cable For cable 150 mm 2 for NR100-250F, 240 mm 2 for NR400-630F Set of 3 29504 32504 Set of 4 29505 32505 For cable 185 mm 2 for NR100-250F, 300 mm 2 for NR400-630F Set of 3 29506 32506 Set of 4 29507 32507 Supplied with 2 (or 3) interphase barriers Terminal extensions Right-angle terminal extensions Set of 3 29261 32484 Set of 4 29262 32485 E22041 E18602 E30908 E18600 E18601 E186599 E21276 Terminal shields E18618 E18606 Straight terminal extensions (NR100/250F) / Edgewide pads (NR400/630F) Set of 3 29263 32486 Set of 4 29264 32487 Spreaders 45 mm 3P 31563 4P 31564 52.5 mm 3P 32490 4P 32491 70 mm 3P 32492 4P 32493 Supplied with 2 (or 3) interphase barriers Short (1 pair) 3 P 29321 32562 4 P 29322 32563 Long (1 pair) 3 P 29323 32564 4 P 29324 32565 Long for spreaders, 52.5 mm (supplied with insulating plate) 3 P 32582 4 P 32583 nterphase barriers Set of 6 29329 32570 7

O push O O profalux reset O push Catalogue numbers (cont.) Accessories (cont.) Electrical auxiliaries Auxiliary contacts (changeover) OF or SD or SDE or SDV 29450 OF or SD or SDE or SDV low level 29452 SDE adapter for unit TM (for NR100F NR250F) 29451 E18608 E18609 Voltage releases NR100 630 F AC Voltage MX MN 24 V 50/60 Hz 29384 29404 48 V 50/60 Hz 29385 29405 110-130 V 50/60 Hz 29386 29406 220-240 V 50/60 Hz and 208-277 V 60 Hz 29387 29407 380-415 V 50 Hz and 440-480 V 60 Hz 29388 29408 DC Voltage MX MN 12 V 29382 29402 24 V 29390 29410 30 V 29391 29411 48 V 29392 29412 60 V 29383 29403 125 V 29393 29413 250 V 29394 29414 Rotary handles NR100-250F NR400-630F E18611 Direct rotary handles Standard black handle 29337 32597 Red handle on yellow front 29339 32599 E18612 Standard extended rotary handle Standard extended rotary handle 29338 32598 Red handle on yellow front 29340 32600 Accessories ndication auxiliary 1 early-break contact 29345 32605 2 early-make contacts 29346 29346 Early-make wiring terminal 29336 Locks NR100-250F NR400-630F Toggle locking device for 1 3 padlocks By removable device 29370 29370 By fixed device 29371 32631 E18621 E18613 Locking of the rotary handle Keylock adapter (keylock not included) 29344 32604 Keylock (keylock adapter not included) Ronis 1351B.500 41940 41940 Profalux KS5 B24 D4Z 42888 42888 E18620 O nterlocking NR100-250F NR400-630F Mechanical interlocking for circuit breakers With ggles 29354 32614 With rotary handle 29369 32621 E21288 nterlocking with key (2 keylocks / 1 key) for rotary handles Keylock kit (keylock not included) (1) 29344 32604 1 set of 2 keylocks Ronis 1351B.500 41950 41950 (1 key only, keylock kit not included) Profalux KS5 B24 D4Z 42878 42878 E26766 (1) For only 1 device. nstallation accessories NR100-250F NR400-630F E18589 Front-panel escutcheons Toggle 29315 32556 Rotary handle or escutcheon collar, P40 29317 32558 COMBT36EN 2004 Schneider Electric - All rights reserved Schneider Electric ndustries SAS 89, bld Franklin Roosevelt F - 92500 Rueil-Malmaison (France) Tel : +33 (0)1 41 29 85 00 As standards, specifications and designs change from time time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper. http://www.schneider-electric.com COMBT36EN Conception: Schneider Electric Design: Ameg Printed: 07/2004