J1000. Compact Inverter Series.

Similar documents
J1000 D E F I 1000 J1000 J1000 J1000 J1000

V1000. Inverter Series.

V1000 Inverter Series

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

V1000 DE ES FR IT V1000 V1000 V1000 V1000

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Description 1/8-7.5HP

YASKAWA AC Drive Compact V/f Control Drive J1000

V1000. AC Drive Series.

More freedom - lower cost

RS232 Communications cable with PC ER M. RJ-45 / USB Adapter Remote Operator Extansion Cable. Communication Unit. Mounting Accesories

Varispeed J7 CIMR-J7AZ. System configuration

GS2 Series - Introduction

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

LIFT INVERTER SERIES L1000A

SYSDrive Frequency Inverter

A1000 D E A1000 A1000 A1000 A1000

MX1S Matrix Converter

ADJUSTABLE FREQUENCY CRANE CONTROLS

LIFT INVERTER SERIES L1000A

Delta Products VFD CP2000 Bypass Control Packages.

L300P Inverter Specifications

INVERTER SERIES HIGH PERFORMANCE VECTOR CONTROL A1000

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

SPRiPM Package Energy-saving Drive Package of Super-Premium-iPM-Motor & Inverter Drive

L1000A. Lift Inverter Drives.

V1000. YASKAWA AC Drive. Compact Vector Control Drive

Technical Information

DE ES A A. For Modernisation and New Installation L1000A L1000A L1000A

VSD Series II Variable Speed Micro Drives

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

Experience & Innovation

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

A V Class: ½ to 175 HP 480V Class: ½ to 1000 HP 600V Class: ½ to 250 HP

LIFT INVERTER SERIES L1000A

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

HVAC Products. Introducing the SED2 Variable Frequency Drives

YASKAWA AC DRIVES. Yaskawa AC Drives The Global Leader in Quality and Reliability. Certified for ISO9001 and ISO14001

Chapter 1: Getting Started User Manual Overview...1 2

YASKAWA AC DRIVES. Yaskawa AC Drives The Global Leader in Quality and Reliability. Certified for ISO9001 and ISO14001

ENERGY-SAVING DRIVE PACKAGE SPRiPM MOTOR & V1000 INVERTER DRIVE

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

BR Second Position Voltages. AA Fourth Position

ABB Component Drives ACS150, 0.5 to 5 Hp

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Main Features of Varis

YASKAWA AC Drive V1000. YASKAWA AC Drive V1000

P V Class: ¾ to 175 HP 480V Class: 1 to 1000 HP 600V Class: 2 to 250 HP

ENERGY-SAVING DRIVE PACKAGE SPRiPM MOTOR & INVERTER DRIVE. SPRiPM


REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

Low voltage AC drives

CIMR-V7AZ Varispeed V7

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

SJ300 Inverter Specifications

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3

High performance Vector Control. Ratings. System configuration

VFD E Series. Features

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

USB Copy Unit COM ERR. Copy. RJ-45 / USB Adapter. Verify. Read LOCK YASKAWA JVOP-181. Remote Operator Extansion Cable. Communication Option Board

NEW INVERTER SERIES V1000

U1000. Low Harmonics Regenerative Matrix Converter.

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

INVEOR "Smart connections." on five levels

AC SERVO DRIVES SIGMA-7 SERIES

SINAMICS G110 Inverter chassis units 0.12 kw to 3 kw

ABB component drives ACS150, 0.5 to 5 Hp

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

3G3JX AC DRIVES. Compact and complete. »» Cost a n d e co-friendly. Downloaded from Elcodis.com electronic components distributor

Frequency Inverters SJ Series Type P1

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Number 1 in efficiency

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

ABB Drives ACS550-U1-059A-2, 20 HP, 3PH, 200 VAC, Wall Mount VFD

SOLUTIONS FOR THE TEXTILE INDUSTRY DRIVES AND CONTROLLERS FOR TEXTILE MACHINERY

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

NEW! Complete IMPULSE Control Panels Available

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

YASKAWA IP54 Solutions. Product Launch Information , C. Schreiter

MULTI LANGUAGE KEYPAD

Regenerative DC Common Bus Supply

HIGH PERFORMANCE VECTOR CONTROL DRIVE

The smd frequency inverter Compact, powerful, without compromise simply smart

Quick Start Guide of CV50- ControlVIT Series

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass

YASKAWA AC Drive A1000

Electromotive Systems IMPULSE G+ Mini Adjustable Frequency Crane Controls

Hydrovar and Packaged Hydrovar

V1000. YASKAWA AC Drive Compact Vector Control Drive

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

MICRO MASTER MICRO MASTER Vector MIDI MASTER Vector

Transcription:

J1000 Compact Inverter Series www.yaskawa.eu.com

Focus on Application Customer orientation and application focus two attributes of machine equipment YASKAWA offers with its J1000 compact inverter drive series. The J1000 meets all automation requirements for compact applications with variable speed operation and energy saving characteristics. A wide range of useful functions upgrade your machine and offer great potentials. The concept of small size and easy handling with the famous YASKAWA reliability makes the J1000 an alternative in the drive market not only cost wise. Wherever You Are - Our Support Team is Always Close to You More than 14.600 Employees Worldwide More than 1.350 Employees in our Global Service Network More than 1.250 Employees in Europe

Applications Conveyor Pump Grinder Hoist Crane Screw Feeder Escalator Fan Drilling Features & Functions Performance Outstanding power to size ratio and gapless side-by-side installation reduce the mounting space to a minimum International Standards: RoHS, CE, cul, UL compliance High starting torque Accurate speed, regardless of load conditions Speed Search for smooth start of coasting motors Stall prevention for reliable handling of overload conditions Functions J1000 automatically sets parameters needed for major applications. The same easily unterstandable parameter structure like in other YASKAWA 1000 series drives allows hassle free setup in shortest time. Parameter Verify, lists changed settings Built-in Digital Operator with 5-digit display Small Design Big Power: 150% overload in heavy duty mode. 120% overload in normal duty mode allowing smaller size inverter to do the job of a bigger one. Drive Wizard Plus Freely available parameter set-up and maintenance tool Options Parameter Copy Unit LED and LCD Remote Operator Serial Communication Option Compatible with RS-422/485 Interface for MEMOBUS communication Speed Potentiometer EMC-Filter Braking Resistors

Technical Information Connection Diagram Terminals marked -, +1, +2, B1, B2 are for connecting an option. Do not wire power supply lines to these terminals. For 1-phase power supply use R/L1 and S/L2 DC reactor (optional) Link Thermal relay (optional) Braking resistor unit (optional) Fuses Power Suppy Filter Main Switch Forward/Stop Reverse/Stop External Fault Shielded Cable Ground Fault Reset Multi-speed 1 +24 V 8 ma Option unit connector DIP switch S1 Multi-function digital inputs (default setting) Fault Multi-function relay output 250 VAC / 30 VDC (10 ma to 1A) (default setting) DIP switch S3 SINK SOURCE Shielded ground terminal Analog input power supply +10.5 VDC, max. 20 ma Analog input 0 to 10 V (20 kω) or 0/4 to 20 ma (250 Ω) Analog output 0 to +10 VDC (2 ma) (Output frequency) Monitor output (default setting) Analog input Symbols: Use twisted pair cables Use shielded twisted pair cables Indicates a main circuit terminal Indicates a control circuit terminal

Model Code CIMR- J C B A 0001 B A A Product Series J1000 Version A: Version A Region Code C: Europe Coating and Protection A: Standard Voltage Class B: Single-phase 230 VAC 2: Three-phase 230 VAC 4: Three-phase 400 VAC Specification A: Standard Inverter Model No. 0001 to 0020 Type B: Standard fin, IP20 without top cover J: Finless (IP20) IP20 Enclosure Self-cooled, Fan-cooled Single-phase, 200 V class W H D W1 H1 H2 D1 D2 t1 Weight (kg) Cooling BA0001B 1 68 128 76 56 118 5 6.5 67.5 3 0.6 Self-cooled BA0002B 1 68 128 76 56 118 5 6.5 67.5 3 0.6 Self-cooled BA0003B 1 68 128 118 56 118 5 38.5 109.5 5 1.0 Self-cooled BA0006B 2 108 128 137.5 96 118 5 58 129 5 1.7 Self-cooled BA0010B 2 108 128 154 96 118 5 58 145.5 5 1.8 Fan cooled Three-phase, 200 V class W H D W1 H1 H2 D1 D2 t1 Weight (kg) Cooling 2A0001B 1 68 128 76 56 118 5 6.5 67.5 3 0.6 Self-cooled 2A0002B 1 68 128 76 56 118 5 6.5 67.5 3 0.6 Self-cooled 2A0004B 1 68 128 108 56 118 5 38.5 99.5 5 0.9 Self-cooled 2A0006B 1 68 128 128 56 118 5 58.5 119.5 5 1.1 Fan cooled 2A0010B 2 108 128 129 96 118 5 58 120.5 5 1.7 Fan cooled 2A0012B 2 108 128 137.5 96 118 5 58 129 5 1.7 Fan cooled 2A0020B 2 140 128 143 128 118 5 65 134.5 5 2.4 Fan cooled Three-phase, 400 V class W H D W1 H1 H2 D1 D2 t1 Weight (kg) Cooling 4A0001B 2 108 128 81 96 118 5 10 72.5 5 1.0 Self-cooled 4A0002B 2 108 128 99 96 118 5 28 90.5 5 1.2 Self-cooled 4A0004B 2 108 128 137.5 96 118 5 58 129 5 1.7 Self-cooled 4A0005B 2 108 128 154 96 118 5 58 145.5 5 1.7 Fan cooled 4A0007B 2 108 128 154 96 118 5 58 145.5 5 1.7 Fan cooled 4A0009B 2 108 128 154 96 118 5 58 145.5 5 1.7 Fan cooled 4A0011B 2 140 128 143 128 118 5 65 134.5 5 2.4 Fan cooled 1 2

IP20 Enclosure Cold Plate Single-phase, 200 V class Weight W H D W1 H1 H2 D2 t1 (kg) BA0001J 1 68 128 71 56 118 5 62.5 3 0.6 BA0002J 1 68 128 71 56 118 5 62.5 3 0.6 BA0003J 1 68 128 81 56 118 5 72.5 3 0.8 BA0006J 2 108 128 76 56 118 5 67.5 4 0.6 BA0010J 2 108 128 76 56 118 5 67.5 4 0.6 Three-phase, 200 V class Weight W H D W1 H1 H2 D2 t1 (kg) 2A0001J 1 68 128 71 56 118 5 62.5 3 0.6 2A0002J 1 68 128 71 56 118 5 62.5 3 0.6 2A0004J 1 68 128 71 56 118 5 62.5 3 0.7 2A0006J 1 68 128 71 56 118 5 62.5 3 0.7 2A0008J 2 108 128 71 96 118 5 62.5 4 1.0 2A0010J 2 108 128 71 96 118 5 62.5 4 1.0 2A0012J 2 108 128 71 96 118 5 71.0 4 1.0 2A0018J 3 140 128 71 128 118 5 69.5 4 1.3 2A0020J 3 140 128 79.5 128 118 5 69.5 4 1.3 Three-phase, 400 V class Weight W H D W1 H1 H2 D2 t1 (kg) 4A0001J 2 108 128 71 96 118 5 62.5 4 0.9 4A0002J 2 108 128 71 96 118 5 62.5 4 0.9 4A0004J 2 108 128 79.5 96 118 5 71.0 4 1.0 4A0005J 2 108 128 96 96 118 5 87.5 4 1.0 4A0007J 2 108 128 96 96 118 5 87.5 4 1.1 4A0009J 2 108 128 96 96 118 5 87.5 4 1.1 4A0011J 3 140 128 78 128 118 5 69.5 4 1.3 2-M4 4-M4 D2 t1 4-M4 D2 t1 H1 H H1 H H1 W1 D W W1 D W 1 2 3 H2 H2 W1 W H2 D

Specifications Control characteristics Control methods V/f Control Frequency Control Range 0.01 to 400 Hz Frequency Accuracy Digital input: within ±0.01% of the max. output frequency (-10 C to +50 C) Analog input: within ±0.5% of the max. output frequency (25 C ±10 C) Frequency Setting Resolution Digital input: 0.01 Hz Analog input: 1/1000 of max. frequency Starting Torque 150% / 3 Hz Speed Control Range 1:20 Main Control Functions Momentary power loss ride-thru, Speed search, Multi-Step Speed (max. 9 steps), Accel/decel time switch, S-curve accel/decel, 3-wire sequence, Cooling fan on/off, Slip compensation, Torque compensation, Frequency jump, Upper/lower limits for frequency reference, DC injection braking at start and stop, Overexcitation braking, Fault restart, Motor stall prevention... Protection function Motor Protection Motor overheat protection based on output current Momentary Overcurrent Drive stops when output current exceeds 200% of Heavy Duty Rating Protection Overload Protection 120% for 60 sec at normal duty, 150% for 60 sec at Heavy Duty Overvoltage Protection 200 V class: Stops when DC bus exceeds approx. 410 V, 400 V class: Stops when DC bus exceeds approx. 820 V Undervoltage Protection Stops when DC bus voltage falls below the following levels: 190 V (3-phase 200 V), 160 V (single-phase 200 V), 380 V (3-phase 400 V), 350 V (3-phase 380 V) Drive Overheat Protection Protected by thermistor Operating environment Area of Use Indoors Ambient Temperature -10 C to +50 C (IP20 open chassis) Humidity 95 RH% or less (non-condensing) Storage Temperature -20 C to +60 C Altitude Max. 1000 m (output derating of 1% per 100 m above 1000 m, max. 3000 m) Shock 10 to 20 Hz (9.8 m/s²) max., 20 to 55 Hz (5.9 m/s²) max. Standards CE, UL, cul, RoHS 200 V class Three Phase Inverter Model 2A 0001 0002 0004 0006 0010 0012 0020 Single Phase Inverter Model BA 0001 0002 0003 0006 0010 Motor output kw at normal duty 0.2 0.4 0.75 1.1 2.2 3.0 5.5 Motor output kw at heavy duty 0.1 0.2 0.4 0.75 1.5 2.2 4.0 Rated output current at normal duty [A]* 1 1.2 1.9 3.5 (3.3) 6.0 9.6 12.0 19.6 Rated output current at heavy duty [A] 0.8*2 1.6* 2 3* 2 5.0* 2 8.0* 3 11.0* 3 17.5* 3 Rated output power at normal duty [kva]* 1 0.5 0.7 1.3 2.3 3.7 4.6 7.5 Rated output power at heavy duty [kva] 0.3 0.6 1.1 1.9 3.0 4.2 6.7 Max. output voltage Single and Three-phase power supply: three-phase 200 to 240 V (relative to input voltage) Max. output frequency 400 Hz Rated input voltage Three-phase 200 to 240 V +10%/-15%, Single-phase 200 to 240 V +10%/-15% Rated input frequency 50/60 Hz, ±5% *1 This value assumes a carrier frequency of 2 khz to Swing PWM. Increasing the carrier frequency requires a reduction in current. *2 This value assumes a carrier frequency of 10 khz. Increasing the carrier frequency requires a reduction in current. *3 This value assumes a carrier frequency of 8 khz. Increasing the carrier frequency requires a reduction in current. 400 V class Three Phase Inverter Model 4A 0001 0002 0004 0005 0007 0009 0011 Motor output kw at normal duty 0.4 0.75 1.5 2.2 3.0 3.7 5.5 Motor output kw at heavy duty 0.2 0.4 0.75 1.5 2.2 3.0 3.7 Rated output current at normal duty [A]* 1 1.2 2.1 4.1 5.4 6.9 8.8 11.1 Rated output current at heavy duty [A]* 3 1.2 1.8 3.4 4.8 5.5 7.2 9.2 Rated output power at normal duty [kva]* 1 0.9 1.6 3.1 4.1 5.3 6.7 8.5 Rated output power at heavy duty [kva]* 3 0.9 1.4 2.6 3.7 4.2 5.5 7.0 Max. output voltage Three-phase 380 to 480 V (proportional to input voltage) Max. output frequency 400 Hz Rated input voltage Three-phase 380 to 480 V +10%/-15% Rated input frequency 50/60 Hz +/-5%

YASKAWA Europe GmbH Drives & Motion Division Hauptstr. 185 65760 Eschborn Germany +49 6196 569-500 support@yaskawa.eu.com www.yaskawa.eu.com 02/2017 YEU_Inv_J1000_EN_v8 Specifications are subject to change without notice for ongoing product modifications and improvements. YASKAWA Europe GmbH. All rights reserved.