Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Similar documents
Product Data. that this product meets the S 95% AFUE S Two -stage operation

N9MPD Product Specifications

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

Cooling Capacity CFM in. w.c. (125 Pa)

G8MVL. Product Specifications

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Cooling Capacity CFM in. w.c. (125 Pa)

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

F8MTL. Product Specifications

Cooling Capacity CFM in. w.c. (125 Pa)

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

G9MXE. Product Specifications

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

G9MXE. Product Specifications

TSTAT0101SC Recommended (sold separately)

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

KG7T (E and N Series)

FG7T (E and N Series)

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

FG7S (C and L Series)

AF90. AF90 Gas Furnace High Efficiency. Features

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

KG7T (C and L Series)

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

KG7T (C and L Series)

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

GMS9/GCS9 SERIES 93% AFUE

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

WFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

FG7T (A and K Series)

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

KG7S (A and K Series)

FG7T (A and K Series)

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

UPFLOW/ HORIZONTAL GAS FURNACE

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

93% Gas Furnaces Single Stage

Product Data. 59SC2A Comfort Series Single---Stage Way Multipoise Condensing Gas Furnace Series 100

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

Upflow, Upflow / Horizontal, Counterflow / Horizontal

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

Multi-Position, Multi-Speed Gas Furnaces

Rheem Value Series Upflow/Horizontal Gas Furnace

Table of Contents GF801U Series

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

Product Data. 59SC2B Comfort Series Single---Stage Way Multipoise Condensing Gas Furnace Series 110

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

Upflow, Upflow / Horizontal, Counterflow

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency

Unit Dimensions FITS-ALL 80 Upflow, Horizontal and Downflow 50,000 thru 125,000 Btu Inputs DUCANE FITS-ALL 80 FURNACE SPECIFICATIONS Length Width Heig

Rheem Classic Series Upflow/Horizontal Gas Furnace

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace

Product Data. 59SC5A Comfort Series Single---Stage Way Multipoise Condensing Gas Furnace Series 1 and 2 STANDARD FEATURES

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

Product Data. 59SC2C ALL 59SC2B SIZE ONLY Comfort Series Single---Stage Way Multipoise Condensing Gas Furnace Series 1

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

Transcription:

COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S 40 (1016 mm) high with wider cabinets, for ease of installation S Factory shipped for natural gas, with Propane Gas conversion kits available S Multipoise - Upflow/downflow/horizontal installation S Vent pipe can be run horizontally or vertically S Internal condensate drain system SERVICE S Self diagnostics S Entire blower assembly mounted on rails Product Data COMFORT S Adjustable timed blower Off delay S Thermal lined, one piece steel cabinet for noise reduction S 24 and 115 VAC humidifier terminal S Electronic air cleaner terminal S Insulated blower compartment EFFICIENCY S 95% AFUE, upflow / downflow S Up to 95%* AFUE, horizontal S Single stage gas valve operation S Single stage integrated control S Multispeed, permanently PSC blower motors S Induced draft blower S In -shot burners S California NOx approved QUALITY S Stainless steel primary heat exchanger S Stainless steel secondary heat exchanger S High temperature limit control prevents overheating S Dependable hot surface ignition with Silicon Nitride igniter S Flame roll-out sensors standard *See Furnace Specifications for clarification A09326 APPLICATION HAZARD Failure to follow this warning could result in personal injury or death This furnace is not designed for use in mobile homes, trailers, or recreational vehicles. C! WARNING CERTIFIED E D E S R T I G N I F I E D ama As an ENERGY STAR Partner, we have determined that this product meets the ENERGY STAR guidelines for energy efficiency. 1

FURNACE SPECIFICATIONS Model Number NATURAL GAS 060- - - 10112 080- - - 10112 080- - - 10116 100- - - 10120 INPUT (btuh){ 60,000 80,000 80,000 100,000 HTG. CAP. (btuh) 58,000 77,000 77,000 96,000 AFUE* - Upflow / Downflow 95 95 95 95 AFUE* - Horizontal 95 94.4 95 95 NOx (Ng/J) <40 <40 <40 <40 TEMP. RISE DEGREES - o F( o C) 30-60 (17-33) 35-65 (19-46) 30-60 (17-33) 30-60 (17-33) VOLTS/HZ/PH 115/1/60 115/1/60 115/1/60 115/1/60 MIN./MAX. VOLTAGE 104/127 104/127 104/127 104/127 RATING PLATE AMPS. 10 10.5 13.6 14.8 TRANSFORMER (V.A.) 40 40 40 40 GASPIPESIZE -In(mm) 1/2 (13 mm) 1/2 (13 mm) 1/2 (13 mm) 1/2 (13 mm) VENT SIZE^ 2 or 3 (51or76mm)OD 3 (76 mm) OD 3 (76 mm) OD 3 (76 mm) OD COOLING CAP. 3.0 3.0 4.0 5.0 FILTER SIZE - In (mm) (1 required) 16 x 25 x 1 16 x 25 x 1 16x25x 1(2) 16x25x1(2) DIMENSIONS - HEIGHT In (mm) 40 (1016) 40 (1016) 40 (1016) 40 (1016) DIMENSIONS - WIDTH X DEPTH - In (mm) 19 1 / 8 x29 (487 x 737) 22 3 / 4 x29 (573 x 737) 22 3 / 4 x29 (573 x 737) 2 x29 (622 x 737) WEIGHT - Lbs. (Kg.) 153 (69.3) 172 (78.0) 180 (81.6) 193 (87.5) * Capacity and AFUE in accordance with U.S. Government DOE test procedures. {Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce ratings 2% for each 1000 ft. (305 M) above sea level. In Canada, derate the unit 5% for elevations 2000 to 4500 ft. (610 to 1372 M) above sea level. ^ Vent size may vary depending on length, number of elbows, standard vent or direct vent. See Installation Instructions. MAX CFM s for Factory Washable Filters Filter Size (In. / mm) CFM 14 X25 356 x 635) 1400 16 X25 (406 x 635) 1600 20 X 25 (508 x 635) 2000 24 X 25 (610 x 635) 2500 Max CFM based on 600 FPM # CFM --- Cubic Feet per Minute airflow. Filter required for each return---air inlet. Airflow performance includes 1 (25 mm) washable (600 FPM max) filter media. Disposable filters are typically rated at 300 FPM and only allow half of the airflow when compared to 600 FPM filters. Example: 20 x 25 @ 600 FPM = 2000 CFM, @ 300 FPM = 1000 CFM. 2

ACCESSORIES Model Number Description Used With Models KGANP48011HW Gas Conversion Kits - Natural gas to propane conversion Kit. Allows field conversion to propane gas. KGAPN41011HW Gas Conversion Kits - Propane to natural gas conversion kit. Allows field conversion to natural gas. KGAFR0901P16 Filter Kits - External filter frame. 16 x25 (406 x 635 mm) KGAFR1001P20 Filter Kits - External filter frame. 20 x 25 (508 x 635 mm) P908-0001 + Condensate neutralizer kit - for condensing gas furnaces All if required KGAVT0801CVT KGAVT0701CVT 3 (76 mm) Concentric vent kit - allows single wall penetration for 2 pipe direct vent applications (90+). 2 (51 mm) Concentric vent kit - allows single wall penetration for 2 pipe direct vent applications (90+). 060 080 100 060 080 100 KGAHA6201PSW High Altitude Pressure Switch Kit 060 KGAHA6301PSW High Altitude Pressure Switch Kit 080 KGAHA6401PSW High Altitude Pressure Switch Kit 100 KGASB0301P01 KGASB0401P02 Combustible Floor Base used without cased coil used KGASB0801P06 KGASB0501P03 KGASB0601P04 Combustible Floor Base used with cased coil used KGASB0701P05 KGADA0101PYN Downflow Coil Adapter used between furnace and coil 333730-701 Size 41 333730-702 Size 42 333730-703 Size 43 333730-704 Size 44 333730-705 Size 45 333730-709 Size 46 333730-710 Orifice Kit + (Qty. 5) Size 47 333730-711 Size 48 333730-712 Size 49 333730-706 Size 54 333730-707 Size 55 333730-708 Size 56 + Must be ordered from Replacement Components Division The direct-vent 4 -way multipoise gas furnace has been designed to work specifically with A -coils offered by Carrier. furnaces are not N -coil compatible. The following table shows our recommended furnace coils: These Model Evaporator Coil Coil Dimension - In. (mm) 060 - - -10112 CA*MP3619ACA 29-3/4 x 22-7/8 x 20-5/8 (756 x 581 x 524) 080 - - -10112 CA*MP4823ACA 29-3/4 x 22-7/8 x 20-5/8 (756 x 581 x 524) 080 - - -10116 CA*MP4823ACA 29-3/4 x 22-7/8 x 20-5/8 (756 x 581 x 524) 100 - - -10120 CA*MP6025ACA 35x24-1/2x20-5/8 (889 x 622 x 524) 3

BLOWER PERFORMANCE Model Number BLOWER SIZE IN. (mm) (DIA. x WIDTH) 060 - - -10112 080 - - -10112 080 - - -10116 100 - - -10120 MOTOR H.P. (TYPE) 1 / 2 (PSC) 1 / 3 (PSC) 1 / 2 (PSC) 3 / 4 (PSC) MOTOR SPEEDS 4 4 4 4 AIRFLOW DATA (CFM) Furnace External Static Pressing (in wc).10 ESP in wc.20 ESP in wc.30 ESP in wc.40 ESP in wc.50 ESP in wc.60 ESP in wc.70 ESP in wc.80 ESP in wc.90 ESP in wc 1.00 ESP in wc Furnace Motor Speed Selection Airflow - CFM LOW 703 976 922 1820 MEDIUM LOW 901 1123 1246 1993 MEDIUM HIGH 1204 1326 1690 2137 HIGH 1478 1456 2032 2240 LOW 649 941 898 1768 MEDIUM LOW 864 1112 1250 1934 MEDIUM HIGH 1154 1312 1650 2062 HIGH 1418 1440 1952 2163 LOW 588 909 872 1722 MEDIUM LOW 818 1085 1226 1872 MEDIUM HIGH 1103 1280 1601 1992 HIGH 1350 1420 1874 2083 LOW 538 870 838 1656 MEDIUM LOW 765 1043 1187 1801 MEDIUM HIGH 1053 1241 1533 1916 HIGH 1280 1379 1785 2002 LOW 488 818 806 1590 MEDIUM LOW 720 1002 1151 1723 MEDIUM HIGH 993 1209 1462 1833 HIGH 1201 1325 1688 1912 LOW 459 784 769 1513 MEDIUM LOW 672 952 1090 1636 MEDIUM HIGH 924 1155 1381 1745 HIGH 1116 1261 1593 1821 LOW 408 714 711 1426 MEDIUM LOW 620 893 1014 1547 MEDIUM HIGH 846 1082 1287 1654 HIGH 1023 1208 1482 1727 LOW 365 640 643 1325 MEDIUM LOW 558 792 918 1437 MEDIUM HIGH 764 1001 1182 1551 HIGH 931 1115 1360 1618 LOW 317 567 570 1199 MEDIUM LOW 489 702 790 1315 MEDIUM HIGH 683 868 1053 1430 HIGH 825 1007 1231 1502 LOW 233 491 488 1047 MEDIUM LOW 428 608 678 1159 MEDIUM HIGH 590 746 850 1275 HIGH 730 830 1052 1356 NOTE: (1) Data based on Bottom Only or One Side return. NOTE: (2) Gray area is above maximum temperature rise range. 4

DIMENSIONS - IN. (MM) Cabinet to Combustible Clearances TOP BOTTOM RH LH BACK FRONT FLUE 1 (25) 0 (0) 0 (0) 0 (0) 0 (0) 3 (76) 0 (0) 2 1 / 4 (57.2) 13 1 / 4 (336.6) TOP LEFT SIDE TRAP (KO) (COUNTERFLOW) AIR INTAKE (KO) (ALTERNATE) GAS VENT TRAP (KO) UPFLOW/HORIZONTAL THERMOSTAT (KO) E 4 13 / 16 (122.2) F 7 (177.8) G AIR INTAKE VENT H 6 11 / 16 ELECTRICAL (177.5) 1 1 / 4 (318) 1 1 / (27) 16 13 11 / 16 (347.7) 31 11 / 16 (34.9) (804.9) 1 3 / (758.8) 8 29 7 / 8 28 3 / 4 (730.3) 24 1 / 16 17 5 (611.2) / 16 19 13 /16 (439.7) 1 11 (503.2) / 16 (42.9) A B FRONT MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS FOR ALL UNITS - in (mm) REAR 0 FRONT (combustion air openings in 3 (76.2) furnace and in structure) Required For Service *24 (609.6) ALL SIDES Of SUPPLY PLENUM 1 (25.4) SIDES 0 VENT 0 TOP OF FURNACE 1 (25.4) *30 (762mm) clearance recommended for furnace removal. Horizontal position: Line contact is permissible only between lines formed by intersections of top and two sides of furnace jacket, and building joists, studs or framing. NOTE: Evaporator A coil drain pan dimensions may vary from furnace duct opening size. Always consult evaporator specifications for duct size requirements. Furnace is designed for bottom return or side return. Return air through back of furnace is NOT allowed. 1 1 / 4 (31.7) 21 5 / 8 1 7 (549.3) / 8 (47.6 ) 24 (609.6) 4 7 / 8 (123.8) Drawing is representative, but some models may vary 2 7 / 8 (73) 4 5 / (109.5) 16 2 3 / 8 (60.3 ) 1 1 / (27) 16 28 1 / 2 (723.9) 18 1 / 2 3 / 4 (19.1) (469.9) TYPE D BOTTOM GAS (KO) RIGHT SIDE TRAP (KO) (COUNTERFLOW) C ELECTRICAL (KO) 23 1 / 8 3 7 AIR INTAKE (KO) / 8 (587.4) (98.4) ALL DIMENSIONS: in (mm) (ALTERNATE) 1 3 / 4 13 / 16 16 (30.2) (122.2) VENT (KO) TRAP (KO) 1 1 / 16 HORIZONTAL 29 7 / 8 (27) (758.8) 7 21 / 27 3 / 4 16 (690.6) 21 5 (177.8) (57.2) / 8 THERMOSTAT 9 13 / 16 (549.3) (249.2) 17 5 / 13 1 / 4 16 33 11 / 16 (439.7) (336.6) (855.7) 1 11 / 16 (KO) (42.9) 40 (1016) Unit Capacity Cabinet Bottom Top A B C D E F G H KO = KnockOut 47 / 215 / 8 8 (123.8) (549.3) 17 / 8 24 (47.6) (609.6) 060-12 19 1 / 8 (485.8) 17 5 / 8 (447.7) 2 1 / 8 (54) 14 3 / 4 (374.7) 2 1 / 2 (63.5) 9 1 / 2 (241.3) 080-12 22 3 / 4 (577.9) 21 1 / 4 (539.8) 1 15 / 16 (49.2) 18 3 / 4 (476.3) 2 1 / 2 (63.5) 9 1 / 2 (241.3) 080-16 100-20 22 3 / 4 (577.9) 2 (622.3) 21 1 / 4 (539.8) 23 (584.2) 1 15 / 16 (49.2) 7 / 16 (11.1) 18 3 / 4 (476.3) 23 (584.2) 2 5 / 8 (66.7) 2 1 / 4 (57.2) 11 3 / 8 (288.9) 12 1 / 4 (311.2) Specifications are subject to change without notice. A09268C 5

Copyright 2009 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/09 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: ---02PD Replaces: ---01PD 6