Pressure Transmitter

Similar documents
Differential Pressure Transmitter

Motorized Two-Way Ball Valve with Screwed-End Connection

ACTIVAL Two-way Ball Valve with Threaded-end Connection

Direct Coupled Damper Actuator Model MY9050A1001

Direct Coupled Damper Actuator Model MY6050A1001

Insertion Thermostat

Valve Linkages Models Q455C, Q455D, Q455F

ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200)

Pipe Temperature Sensor

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve

Insertion Temperature/Humidity/ Dewpoint temperature Sensor HTY78X3/HY78X3/HTY78X6/HY78X6/HY79X3

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection for High Differential Pressure Application (JIS 10K-FC200, -SCS13A)

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

Digital Flow Switch (Sensor Part) Operation Manual

Model Pressure range ON/OFF output Linear output

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (Spring Return Type Actuator) (JIS 10K-FC200, -SCS13A)

ACTIVAL Flow Measurement and Control Valve Standalone Model (PN10 / GG-20)

Digital display Pressure range ON/OFF output Linear output Model

Direct Coupled Damper Actuator

ACTIVAL Three-Way Ball Valve with Threaded-End Connection

Series 10-ZSE40A(F)/10-ISE40A

Model Pressure range ON/OFF output Linear output

DC2-Wire Unshielded Cylindrical Proximity Switches

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Filterpack FR-BFP2-(H)0.4K to (H)15K

POWER REGULATOR LD -40PSU

SATRON VTe pressure transmitter

Pressure transmitter for industrial applications Type MBS 4510

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve

Intelligent Component Series ACTIVAL Flow Measurement and Control Valve (JIS 10K / FC200)

2-Color Display High-Precision Digital Pressure Switch

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-Color Display High-Precision Digital Pressure Switch

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

ELECTRONIC CONTROL ACTUATOR

HS1L Interlock Switches with Solenoid

Related vacuum products

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

Pressure transmitters for industrial applications Type MBS 4510

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

ELECTRONIC CONTROL ACTUATOR

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

M-COSR-3 / M-COSR-16 / M-COSR-21

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve Model MY53X0AX000

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (PN16 / GG-20) (Spring Return Type Actuator)

Intelligent Component Series ACTIVAL Electro-Mechanical Actuator for Model VY530X Control Ball Valve Model MY5390A

Pressure transmitter for industrial applications Type MBS 4500

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Contents. 1. Preface Product Outline Model Number Construction Specifications Outline Drawings and Wiring diagram...

AC/DC2-wire Type Cylindrical Proximity Switches

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection <4-20 ma DC Input with 4-20 ma DC Feedback Output> (JIS 10K-FC200, -SCS13A)

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

DPS280 / DVS280 Series

Motorized Pressure Reducing Valve for Steam COSPECT M-COS-3 / M-COS-16 / M-COS-21

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (JIS 10K / FC200, SCS13A) (Spring Return Type Actuator)

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX:

Low Differential Pressure Sensor ±1% F.S.

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (JIS 10K / FC200, SCS13A)

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

Digital display Pressure range ON/OFF output Linear output Model

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Operation mode. Sensing distance N.O. N.C. N.O. N.C. N.O. N.C. 7mm

Pressure sensor with built-in amplification and temperature compensation circuit

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

Switching DC Power Supply

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

ELECTRIC ACTUATOR. Unic Series ROTARY TYPE Unic Z, 05 Unic 10 Unic 20, 40 Unic 60, 100, 150, 200 OPERATION MANUAL. Koei Industry Co., Ltd.

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

MIZCON Plus Cooling Tower Controller Model R7010W

Intelligent Component Series ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200)

ZIRCONIA OXYGEN ANALYZER CONVERTER

SATRON VT Pressure Transmitter

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

DC2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors N.O. N.C. N.O. N.C. N.O. N.C. 8mm N.O. N.C. N.O. N.O. N.C. N.O. N.O. N.C.

Pressure transmitter for marine applications MBS 3100 and MBS 3150

ELECTRONIC CONTROL ACTUATOR

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Oil-free piston compressors KK and piston vacuum pumps KV

Transcription:

Specifications/Instructions Pressure Transmitter General Model PY7100A pressure transmitter is a small pressure transmitter using a semiconductor strain gauge. It detects the pressure of chilled/hot water, brine, lubricating oil, steam, air, and other fluids, and converts measured values into 4 to 20 ma DC electric signals for the purpose of measuring and controlling the pressure. Features (1) A small and highly precise pressure transmitter using a semiconductor strain gauge. (2) This pressure transmitter detects the pressure of brine, lubricating oil, air, steam, and other fluids as well as chilled/hot water. (3) Its wetted parts are made of stainless steel to ensure the corrosion resistance and a long life. Model Numbers Model number Measuring range Allowable pressure resistance* 1 PY7100A3000 0 to 0.5 MPa 1 MPa PY7100A3008 0 to 1.0 MPa 2 MPa PY7100A3016 0 to 2.0 MPa 4 MPa *1 The allowable pressure resistance means the pressure limit where the repeatability of measured value is assured electrically. Accessories Item Part number Remarks Siphon tube (equipped with cock) FP10-T01 Allowable pressure: 3 MPa Allowable temperature: 200 C or less Siphon tube (no cock) FP10-993 Allowable pressure: 20 MPa Allowable temperature: 350 or less 24 V DC power supply unit QY7000C1000 Power supply: 100 V AC ± 10 %, 50/60 Hz QY7000C2000 Power supply: 200 V AC ± 10 %, 50/60 Hz Seal connector 83104098-003 Cable external diameter: 8.5 to 12.5 1

Safety Instructions Please read instructions carefully and use the product as specified in this manual. Be sure to keep this manual near by for ready reference. Usage Restrictions This product is targeted for general air conditioning. Do not use this product in a situation where human life may be affected. If this product is used in a clean room or a place where reliability or control accuracy is particularly required, please contact our sales representative. Azbil Corporation will not bear any responsibility for the results produced by the operators. Warnings and Cautions Alerts users that improper handling may WARNING cause death or serious injury. Alerts users that improper handling may CAUTION cause minor injury or material loss. Signs Alerts users possible hazardous conditions caused by erroneous operation or erroneous use. The symbol inside indicates the specific type of danger. (For example, the sign on the left warns of the risk of electric shock.) Notifies users that specific actions are prohibited to prevent possible danger. The symbol inside graphically indicates the prohibited action. (For example, the sign on the left notifies that disassembly is prohibited.) Instructs users to carry out a specific obligatory action to prevent possible danger. The symbol inside graphically indicates the actual action to be carried out. (For example, the sign on the left indicates general instructions.) WARNING Before wiring or maintenance, be sure to turn off the power to this product. Failure to do so might cause electric shock or device failure CAUTION Use the product under the operating conditions (temperature, humidity, power, vibration, shock, mounting direction, atmospheric condition, etc.) as listed in the specifications. Use this product within the lifespan given in the specifications and avoid instrumentations that keep the product to operate excessively. Continued use beyond this lifespan might cause Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards. All wiring must comply with applicable codes and ordinances. Do not put load or weight on the product. Doing so might damage the product. To connect the wires to the screw terminals, use crimp terminal lugs with insulation. Failure to do so might cause short circuit or electric shock. Do not disassemble the product. Doing so might cause electric shock or device failure. When the transmitter is used for measuring high temperature fluid, do not touch the siphon tube unnecessarily. If you touch it, you may get burned. Dispose of the product as industrial waste in accordance with your local regulations. Do not reuse all or part of this product. 2

Specifications Pressure transmitter Item Specification Detection method Semiconductor strain gauge Measuring object Chilled/hot water, lubricating oil, brine, steam, air, and other fluids (The part that contacts with fluids should not be corroded.) Operating temperature -20 to 70 C (without freezing) Output signal 4 to 20 ma DC Linear output characteristic Load resistance Max. 500 Ω Accuracy ± 0.5 % FS, including linearity and hysteresis Influence of ambient temperature ± 0.05 % FS/ C fluctuation Zero and span adjusting range Zero: 10 % FS Span: 20 % FS Supply power 24 V DC ± 10 % (with over-load protection function) Power consumption Approx. 0.5 VA Insulation resistance 50 V DC, 100 MΩ (between terminal and case) Withstand voltage 250 V AC, 1 min Environment conditions Rated operation conditions Transportation/storage conditions Ambient -20 to 70 C -30 to 80 C temperature Ambient humidity 5 to 95 % RH (without condensation) 5 to 95 % RH (without condensation) Indoor mounting type Vibration resistance 20 m/s² (10 150 Hz) 20 m/s² (10 150 Hz) Case structure Splash-proof type (IEC 60529) (with sealed connectors) Weight Approx. 370 g Material, surface Case, cover Aluminum diecast coating color Silver Wetted parts Stainless steel Connection system R1/2 (male screws) 24 V DC power supply unit Item Specification Output voltage 24 V DC ± 5 % (at the rated load (0.13 A) and at no load) Over-load protection Power disconnection system, automatic recovery Environment conditions Rated operation conditions Transportation/storage conditions Ambient temperature -10 to 50 C -20 to 60 C Ambient humidity 85 % RH (without condensation) 95 % RH (without condensation) Mounting Mount in panel (vertically or horizontally) 3

Dimensions Pressure transmitter Figure 1 Pressure transmitter (mm) Siphon tube (equipped with cock) Siphon tube (no cock) DN6, SCH80 Figure 2 Siphon tube (equipped with cock) (mm) Figure 3 Siphon tube (no cock) (mm) 4

Table 1 Materials of siphon tube (equipped with cock) No. Part Material Remarks 1 Joint Stainless steel 2 Pipe Stainless steel 3 Joint Stainless steel Table 2 Materials of siphon tube (no cock) No. Part Material Remarks 1 Joint Stainless steel 2 Pipe Stainless steel 3 Union nut Stainless steel 4 Body Stainless steel Lost wax 5 Handle Stainless steel Plastic-jacketed 6 Nut Stainless steel 24 V DC power supply unit Figure 5 Terminal layout Figure 4 Terminal dimensions 5

Installation CAUTION Use this product under the operating conditions (for temperature, humidity, power, vibration, shock, mounting direction, atmosphere, etc.) listed in the specifications. Failure to do so might cause fire or device failure. Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards. Installation place IMPORTANT: Mount this transmitter indoors where the ambient temperature is 20 to 70 C and the humidity is 95% RH or less. (No condensation is allowed. Measuring objects shall be free of being frozen.) For measuring steam, keep the ambient temperature of transmitter at 70 C or less by lengthening the siphon tube and connection pipe, etc. Keep a space enough for maintenance and adjustment around the transmitter. If the transmitter is mounted on a pipe in which cryogenic fluid (e.g., chilled water, brine) flows, the sensor part may be condensed and damaged. Be sure to use the siphon tube to prevent condensation. If the siphon tube is used in a vibration environment, protect the tube with a supporting structure, etc. from excessive force by vibration. Stop valve Figure 6 Installation (attached to pipe) Figure 7 Installation (attached vertically) Checking items Be careful not to drop or shock the product during transportation, unpacking, and installation. Check that the model number of the transmitter delivered to you is the model number you ordered. To install the transmitter to a pipe, install it with a pressure gauge as shown in Figure 6. Be sure to install a stop valve for maintenance. For measuring cryogenic fluid with the transmitter, arrange to keep the transmitter temperature around its ambient by using the siphon tube, etc. This prevents a damage on the transmitter due to condensation. Mount the transmitter in the position ranging from vertically upright to ±90. However, if the siphon tube is used, mount it vertically. If the transmitter is used in a vibration environment, protect the facilitating pipe and siphon tube with a supporting structure, etc. from excessive force by vibration. Never apply heat insulator for the siphon tube. Installation procedure (1) Prepare a pressure outlet on the pipe (Figure 8). (2) Mount a stop valve and make a R1/2 female screw. (3) Screw the transmitter unit in the pressure outlet. Pressure transmitter Model PY7100A Stop valve If the pressure transmitter is screwed in the outlet filled with measuring fluid, a pressure of 7 to 10 MPa will be applied to the pressure transmitter and the reproducibility will be lost. Provide an air layer of minimum 30mm before screwing in the pressure transmitter. Figure 8 Note for installation 6

Wiring WARNING Before wiring or maintenance, be sure to turn off the power to this product. Failure to do might cause electric shock or device failure. CAUTION Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards. All wiring must comply with applicable codes and ordinances. To connect the wires to the screw terminals, use crimp terminal lugs with insulation. Failure to do so might cause short circuit. When the transmitter is used for measuring high temperature fluid, do not touch the siphon tube unnecessarily. If you touch it, you may get burned. IMPORTANT: For wiring, use an indoor vinyl cable (thicker than IV 1.25 mm²). Wiring length is maximum 20 m. Use a shielded cable, if the transmitter is presumable to be affected by noises and other interferences through the wiring route. Connect the signal receiving instrument to the ground. For the wiring method, refer to Figure 9. If this product is used for measuring pressure of 1 MPa or less, atmosphere is supplied through the cable, so do not seal the cable end. Use the sealed connectors to ensure splash-proof. Strip the cable sheath about 80 mm and the core wire sheath in accordance with the M3 crimp terminal lug that you use. Crimp the terminal lugs on the end of the core wires. Shield the cable at the end of the sheath. Remove the lid of the terminal box and insert the cable through the inlet deeply into the gasket. Tighten the seal connector and seal the terminal inlet. Connect the wires to the terminal posts. Cover the terminal box with the lid to seal. Adjustment IMPORTANT: This transmitter has been precisely adjusted, before the shipment from the factory, so that the transmitter outputs the 4 to 20 ma signals in response to the detection range. No adjustment is required for normal uses. If you change the relation between the detection range and output signals, or if you set the relation precisely, adjust the transmitter by using a pressure pump and a precision pressure gauge. Output signals can be checked across the "+ CH" and "-" terminal using an ammeter of 10 Ω or less. (See Figure 10.) If the output signals pulsate, compensate the pulsation using the filtering function on the controller. If your controller does not have the filtering function, use a dampener for compensation. Zero adjustment (1) Close the stop valve and remove the pressure transmitter from the pipe. (2) Open the pressure receiving part to the open air, and adjust the ZERO control knob (Z) so that the output signal becomes 4 ma. Turn the knob clockwise to increase the output signal. The adjustable range is 10 % FS. Span adjustment (1) Close the stop valve and remove the pressure transmitter from the pipe. (2) Apply the high-limit pressure of the detection range by using a pressure pump. Adjust the span control knob (S) under this condition so that the output signal becomes 20mA. Turn the knob clockwise to increase the output signal. The span adjustable range is 20% FS. Zero adjustment knob Span adjustment knob Terminal screws M3 Figure 10 Terminal box layout Figure 9 Wiring diagram 7

Operation Check that the pressure range of the product is correct. Check that all the screws are tightened. Before supplying power, check that all the wirings are correct. Check that the pressure transmitter is mounted correctly and open the stop valve. Check that the rated voltage and current of the power supply unit, and the inner resistance of the devices connected externally are within the rated range of the transmitter. After power on, allow minimum 5 min warm-up operation. Then, start the normal operation. Maintenance CAUTION When the transmitter is used for measuring high temperature fluid, do not touch the siphon tube unnecessarily. If you touch it, you may get burned. IMPORTANT Before removing the pressure transmitter, close the stop valve. Failure to do so may cause spurting of the liquid from the pipe and you may get injured. Although there is no moving element in this product's sensor part, inspect the transmitter according to your usage. Inspection items are described below. Item Inspection cycle Inspection method Loose terminal screws 6 months Check that terminal posts for the transmitter, power supply, and signal receiving instrument are screwed tightly. Leakage of liquid 6 months Check that there is no leakage around the joints and sealed parts. Insulation resistance between the terminals and case Output check using the pressure reference meter and ammeter 6 months Check that the resistance is 100 MΩ or more at 50 V DC. 6 months Check that zero point output is 4 ma DC, span output is 20 ma DC. Specifications are subject to change without notice. Building Systems Company http://www.azbil.com/ Rev.2.0 Nov. 2014 (J: AI-4539 Rev.13.0) AB-4539 8