cor Long Run Experience

Similar documents
DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX earth leakage DPX 3 -I earth leakage

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX 630 Electronic release

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 1600 Electronic release

01 Spectra Plus - Introduction

DPX Magnetic only

DRX 125 Circuit breaker (not adjustable)


DPX moulded case circuit breakers

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

DRX 250 B/N/H Circuit breaker (not adjustable)

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DRX 100 B/N/H Circuit breaker (not adjustable)

Thermal magnetic and trip-free switches

Protection components

DPX Electronic + earth leakage

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features


Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Phase + Neutral, neutral on left side

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

3 - Protection components Motor circuit-breakers

Phase + Neutral, neutral on right side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

C60H-DC C curve. Catalogue numbers

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

DX³ 4-pole RCBO 6000 A/10 ka

Molded case circuit breakers

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Circuit protection and control devices 0.5 to 6300 A

DMX 3 -I 2500 switch disconnectors

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

Vistop TM isolating switches 63 to 160A

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

(p. 47) (p. 155) (p. 155)

Power protection solutions

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

K50H004UP cam changeover switch - 4-pole A - screw mounting

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Technical Data Accessories MCBs Ex9B.

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

D509E. Manual Motor - Starters

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCBO 6000A Phase + Neutral, neutral on left

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

max pole for t=15 ms

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

3VU13, 3VU16 Circuit-Breakers

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

RX 3 M.C.B A up to 63 A

Breaking and protection devices

Moulded case circuit breakers

MS25, MST25, MS20, MST20

RX 3 M.C.B A up to 63 A

Motor Protection Circuit Breakers 3VU13 and 3VU16

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

MOULDED CASE CIRCUIT BREAKERS BC160N

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Data Sheet Manual Motor Starters Ex9SN Series

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

The effective choice The benefits of a product with the highest quality standards

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MS General Information Extended Product Type: MS

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Thermal-magnetic Miniature Circuit Breaker 4230-T...

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

DX³ RCBO 6000A Phase + Neutral, neutral on right

Miniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures

Electronic circuit breaker EBU10-T

MCBs and RCDs LR TM 6000

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Cat N 3. OVERALL DIMENSIONS

K30H001YP cam star-delta switch - 3-pole A - screw mounting

MCCB Accessories to suit AF

Manual Motor Starters

(1,5 modules per pole)

Motor Protection Circuit Breakers

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary

- Moulded-case Circuit Breaker

DX³ RCCBs - ID 4P up to 100 A

Record SL. Moulded Case Circuit Breaker

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

Transcription:

Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience

cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30 25 DH160 D160 DH250 DH400 DH630 D250 D400 D630 D800 D1250 0 160 250 400 630 800 1250 Ith (A) Benefits The Record circuit breakers are suitable for three levels of performances: - normal breaking capacity, type D, - high breaking capacity, type DH, - limiter circuit breaker, type D... L, - earth leakage circuit breakers, type DM. By adding or replacing elements, it is possible to perform the following functions: - earth leakage protection, - visible isolation, - low magnetic threshold protection, - instantaneous protection alone - selectivity of protection(see also selectivity tables). As a variant: - source changeover switches for replacement source, - switches for controlling and isolating circuits. Description Within an isolating box, the Record circuit breaker contains: - 3 or 4 poles, - A mechanism enabling fully visible isolation. The control handle can only display "OFF" if all the contacts are actually open and separated by a safe distance. - A display showing the exact position of contacts - red: contacts closed - white: contacts open, unit tripped - green: contacts open, fully visible isolation, - 1 release unit: - integrated for D160, D250 - interchangeable for D400, D630, D800, D1250 containing: - a trip push-button - compensated thermal elements for - 5 C to + 40 C adjustable from: 0.75 to 1 for D160, D250 0.8 to 1 for D400, D630, D800, D1250 - Adjustable magnetic releases (fixed on 10xIn for D160) Structure and versions Record circuit breakers are available as: - fixed unit, front or rear connections, - withdrawable unit with front or rear connections. The withdrawable version contains: - a monoblock fixed isolating part, protection level IP 2X, - a safety system at withdrawable, - An upline-downline error prevention device, - optional: rating error prevention device, wiring isolation. The Record D800 and D1250 withdrawable devices have a fixed part with plug-in and withdrawal control by crank and optional isolation shutter and position indicator. DM earth leakage circuit breakers give protection in case of: - isolation fault (decree of 14/11/1988) - overload and short-circuit Record switches are derived from Record circuit breakers. They can receive auxiliaries, controls, and the circuit breaker accessories from which they come. Auxiliaries,accessories Record circuit breakers can receive: - auxiliaries: - display contacts (ON-OFF, fault) - voltmetric releases (ST shunt, UV undervoltage) - Manual rotary control to provide IP40 and IP55 - installation and connection accessories: - terminals, terminal covers, - padlocks or locks.

cor Moulded Case Circuit Breaker D160 D250 D400 D630 Technical data Circuit breakers Rated current Ith 40 0 C (A) Ith 50 0 C (A) Ith 60 0 C (A) Rated operational voltage Ue AC 50/60 Hz (V) DC (V) Rated insulation voltage Ui (V) Ultimate breaking capacity Icu AC 50/60 Hz 220/240V 380/415V 500V 600/690V 1000V (1) DC (L/R = 15 ms) (3) 125V 250V 500V Service short circuit breaking capacity Ics AC 50/60Hz (% Icu) DC (L/R = 15 ms) (% Icu) Rated short circuit making capacity Icm 220/240V (ka peak) 380/415V (ka peak) Single pole IT system breaking capacity Ice 220/240V (% Icu) 380/415V (% Icu) Rated impulse withstand voltage Uimp (kv) Category of use Number of poles Endurance Mechanical ops Electrical ops Total fault elimination time (ms) Pollution degree D160 DH160 D160L D250 DH250 D250L 160 160 160 250 250 230 152 152 152 237.5 237.5 215 144 144 144 225 225 205 690 690 690 690 690 690 500 500 500 500 500 500 690 690 690 690 690 690 70 80 130 70 80 130 30 50 100 35 50 100 12 14 70 20 22 80 5 7 25 7 8 30 - - - - - - 40 40 100 50 50 100 20 40 100 35 50 100 20 40 100 25 45 100 75 75 75 75 75 75 75 75 75 75 75 75 154 176 286 154 176 286 66 110 220 77 110 220 40 60 75 50 60 75 15 10 25 20 15 30 8 8 8 8 8 8 A A A A A A 3-4 3-4 3-4 3-4 3-4 3-4 10 000 10 000 10 000 10 000 10 000 10 000 4 000 4 000 4 000 4 000 4 000 4 000 8 8 3.5 8 8 3.5 3 3 3 3 3 3 D400 DH400 D400L D630 400 400 400 630 380 380 380 580 360 360 360 535 690 690 690 690 500 500 500 500 690 690 690 690 50 70 130 70 35 50 100 35 30 35 50 20 10 12 18 10 - - 10-80 100 100 80 60 85 100 60 40 50 60 40 100 75 75 75 100 75 75 75 110 154 286 154 77 110 220 77 70 70 75 50 30 25 20 25 8 8 8 8 A A A A 3-4 3-4 3-4 3-4 5 000 5 000 5 000 5 000 2 000 2 000 2 000 2 000 8 8 6 12 3 3 3 3 Weights (fixed circuit breaker-3p) (kg) 1.8 2.3 5.85 8.45 Circuit breakers D160 DH160 D160L D250 DH250 D250L D400 DH400 D400L D630 Rated TM 25-32-40-63-100-125-160 100-125-160-200-250 250-320-400 4

D630 D800 D1250 0 D400L D630 DH630 D630L D800 DH800 D1250 400 630 630 630 800 800 1250 380 580 580 580 760 760 1150 360 535 535 535 720 720 1050 690 690 690 690 690 690 690 500 500 500 500 500 500 500 690 690 690 690 690 690 690 130 70 80 130 70 80 60 100 35 50 100 50 70 50 50 20 25 60 25 35 35 18 10 12 25 15 20 25 10 - - 12 - - 21 100 80 100 100 80 100 70 100 60 85 100 60 80 50 60 40 50 60 40 50 70 75 75 75 75 75 75 75 75 75 75 75 75 75 75 286 154 176 286 154 176 132 220 77 110 220 110 154 132 75 50 60 75 70 85 100 20 25 25 25 30 20 40 8 8 8 8 8 8 8 A A A A A A A 3-4 3-4 3-4 3-4 3-4 3-4 3-4 5 000 5 000 5 000 5 000 5 000 5 000 3 000 2 000 2 000 2 000 2 000 1 000 1 000 1 000 6 12 12 6 12 12 20 3 3 3 3 3 3 3 8.45 11.9 16.5 0 D400L D630 DH630 D630L D800 DH800 D1250 400 400-500-630 630-800 1000-1250

Record Type D 3-4 pole,160 to 250A Circuit breakers D160 - DH160 - D250 - DH250 3 poles 4 poles A B C 160 250 160 200 12.5 32.5 12.5 14 Type D 3-4 pole,400 to 800A Circuit breakers D400 - DH400 - D400L - D630 - DH630 - D630L - D800 - DH800 Circuit breakers D1250 3/4 poles 3/4 poles D400 - D630 D800 Type D 3-4 pole,1000 to 1250A A B C D3p D4p E F G H J J1 K L3p L4p M N P R S T 400 630 800 25 35 35 45 70 70 32 40-45 70 70 90 70 70 47.5 70 70 25 13 13 11 12-10 12-38 44-35.5 41-5 6 6 140 210 210 185 280 280-190 200-60 65-225 244-10 28-12.5 22-260 270 D Ref.TP0487AF

Record Maximum equipment ND160 D160/250 D400 (1) D630/800 (1) D1250 (1) ST release left mounting right mounting UV release left mounting right mounting AS contacts - 1 NO/NC left mounting right mounting BA contact - 1 NO/NC or 1 0 0 0 0 1 0 0 1 1 1 1 1 1 or or 0 1 0 0 0 0 0 0 1 0 0 0 2 0 0 2 2 2 1 1 1 or or or 0 0 0 0 0 1 0 1 0 0 1 1 0 0 0 0 2 2 0 0 2 0 2 0 1 1 1 1 or or or 0 1 0 0 0 0 0 1 0 0 1 1 0 0 0 0 3 0 0 0 3 3 3 0 1 1 1 1 or or or or 0 0 1 0 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 3 1 0 0 0 3 3 3 3 0 0 1 1 1 1 (1) Option of 3 extra AS contacts on 4P units (except D400 4P: 2 AS contacts) Withdrawable version, max. equipment limited by the number of wiring isolations: - D160 to D400 3 and 4P, D630 3P, D800 3P: 16 wires max. - D630 4P, D800 4P, D1250 3 and 4P: 24 wires max. Operating curves D160 D250 D400 D630-630A D800-630/800A D1250-1000/1250A Ref.TP0487AF