Bulletin 190-M Selection Guide
Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located on Load Side of Starter Load Side Coil Terminal Exposed for Ease of Wiring and Accessory Installation Provision for Bul. 100-C and 140 Accessories TABLE OF CONTENTS Description Page Description Page Product Selection..................................... 3 Dimensions..................................... 5 Description Bulletin 190-M are ideal for use in direct-on-line or group motor installations. These compact starters are prewired and assembled, 45mm wide, can be panel- or DIN Rail-mounted and will accept a wide range of MCS accessories. Conformity to Standards: IEC 947-4 Approvals: CE CSA 22.2 No. 14 CSA Certified (File: LR13908) Your order must include: UL 508 UL Listed (File: E 14841) Cat. No. of the compact starter and protector selected. with coil code auxiliary configuration If required, Cat. No. of any accessories. 2
Bulletin 190-M Product Selection Type 1 Protection Auxiliary contact connected to terminals on the bottom Utilizes accessories of Bulletin 140-M Manual Motor Starter/Protectors & 100-C Contactors Mounting Options: Screw fixing Fixing on one or two 35mm DIN Rails Fixing on one 75mm DIN Rail Type 1 short circuit coordination according to IEC 947-4-1➊ Conditional rated short-circuit current (I q ) = Ultimate short-circuit breaking capacity (I cu ) Voltages: please inquire about other voltages 3 (50Hz) [kw] Ratings AC-2, AC-3 3 (60Hz)➋ [HP] Thermal Release Magnetic Release I cu without Current Limiter I cu with Current Limiter Direct-on-line Starter 400V 230V 460V 575V [A] [A] [ka] [ka] Catalog No. ➌ - ➍ 0.02 0.10...0.16 1.8 100 190-M2-A16 10-A10 0.04 0.16...0.25 2.8 100 190-M2-A25 10-A10 0.06/0.09 0.25...0.40 4.4 100 190-M2-A40 10-A10 0.09/0.12 0.40...0.63 6.9 100 190-M2-A63 10-A10 0.18/0.37 1/2 1/2 0.63...1.00 11 100 190-M2-B10 10-A10 0.37/0.55 3/4 1 1.00...1.60 18 100 190-M2-B16 10-A10 0.55/0.75 1/2 1 1-1/2 1.60...2.50 28 100 190-M2-B25 10-A10 1.1/1.5 1 1 3 2.50...4.00 44 100 190-M1-B40 10-A10 2.2/2.5 1-1/2 3 5 4.00...6.30 69 100 190-M1-B63 10-A10 3.0/5.5 3 5 7-1/2 6.30...10.0 110 20 50 190-M1-C10 10-A10 5.5/7.5 5 10 10 10.0...16.0 176 10 50 190-M1-C16 10-A10 7.5/10 5 10 10 16.0...20.0 220 8 50 190-M1-C25 10-A10 11/12.5 7-1/2 15 15 20.0...25.0 275 8 50 190-M1-C25 10-A10 ➊The Bulletin 140 Manual motor Starter/Protector is a component of the 190-M Compact Starter and meets the circuit breaker requirements of IEC 947-2. This device, however, does not meet CSA and UL circuit breaker requirements. The Bulletin 140 is CSA Certified and UL Listed as a Manual Motor Controller and is rated for Group Motor Installations. ➋ For North American applications: HP ratings shown in the table are for reference. The final selection of the motor starter depends on the actual motor full load current and service factor as follows. For motor with service factor of 1.15, or greater: Use motor nameplate full load current and choose the motor starter with the appropriate current range. Example: Motor F.L.C. = 4.2A; S.F. = 1.15. Select Cat. No. 190-M1-B63 10-A10. For motor with service factor less than 1.15: Multiply motor nameplate full load current by 0.9 and use the resulting value to choose the motor starter with the appropriate current range. Example: motor F.L.C. = 4.2A; S.F. = 1.0; 4.2A x 0.9 = 3.78A. Select Cat. No. 190-M1-B40 10A10. ➌ Auxiliary contacts for contactor Standard Voltage Codes for AC Control Option Contact Configuration 24V 110V 120V 01 50Hz D 60Hz J D ➍Trip and/or auxiliary contact for manual motor starter/protector 50/60 Hz Option Number of N.O./N.C. For other control voltage codes, contact your A-B sales office. T01 T10 1 N.O. A01 For other auxiliary contacts and accessories, see Pub. No. 0100C-1.0.1 3 Prices Consult Sales Office or price list
Type 2 Protection Bulletin 190-M Product Selection, Continued Type 2 short circuit coordination according to IEC 947-4-1 ➊ Conditional rated short-circuit current (I q ) = 50kA I cu = Ultimate short-circuit breaking capacity Voltages: please inquire about other voltages Ratings AC-2, AC-3 3 [kw] (50Hz) 3 [HP] (60Hz)➋ Thermal Release Magnetic Release I cu Direct-on-line Starter 400V 230V 460V 575V [A] [A] [ka] Catalog No. ➌ - ➍ 0.02 0.10...0.16 1.8 100 190-M2-A16 10-A10 0.04 0.16...0.25 2.8 100 190-M2-A25 10-A10 0.06/0.09 0.25...0.40 4.4 100 190-M2-A40 10-A10 0.09/0.12 0.40...0.63 6.9 100 190-M2-A63 10-A10 0.18/0.37 1/2 1/2 0.63...1.00 11 100 190-M2-B10 10-A10 0.37/0.55 3/4 1 1.00...1.60 18 100 190-M2-B16 10-A10 0.55/0.75 1/2 1 1-1/2 1.60...2.50 28 100 190-M2-B25 10-A10 1.1/1.5 1 1 3 2.50...4.00 44 100 190-M2-B40 10-A10 ➊The Bulletin 140 Manual Motor Starter/Protector is a component of the 190-M Compact Starter and meets the circuit breaker requirements of IEC 947-2. This device, however, does not meet CSA and UL circuit breaker requirements. The Bulletin 140 is CSA Certified and UL Listed as a Manual Motor Controller and is rated for Group Motor Installations. ➋For North American applications: HP ratings shown in the table are for reference. The final selection of the motor starter depends on the actual motor full load current and service factor as follows. For motor with service factor of 1.15 or greater: Use motor nameplate full load current and choose the motor starter with the appropriate current range. Example: Motor F.L.C. = 4.2A; S.F. = 1.15. Select Cat. No. 190-M1-B63 10-A10. For motor with service factor less than 1.15: Multiply motor nameplate full load current by 0.9 and use the resulting value to choose the motor starter with the appropriate current range. Example: motor F.L.C. = 4.2A; S.F. = 1.0; 4.2A x 0.9 = 3.78A. Select Cat. No. 190-M1-B40 10A10. ➌ Auxiliary contacts for contactor Standard Voltage Codes for AC Control Option Contact Configuration 24V 110V 120V 01 50Hz D 60Hz J D ➍Trip and/or auxiliary contact for manual motor starter/protector 50/60 Hz Option Number of N.O./N.C. For other control voltage codes, contact your A-B sales office. T01 T10 1 N.O. A01 For other auxiliary contacts and accessories, see Pub. No. 0100C-1.0.1 Prices Consult Sales Office or price list 4
Bulletin 190-M Approximate Dimensions Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. (1) 75mm DIN Rail (1) 35x15mm DIN Rail (2) 35x7.5mm DIN Rail Mounting Position 5
Publication 0190M-2.0 - June 1998 1998 Rockwell International. All Rights Reserved. Printed in USA