Bulletin 190-M Compact Starters. Selection Guide

Similar documents
Technical Information

XT IEC Power Control Manual Motor Protectors

Selection Guide. Control Circuit and Load Protection

Bulletin 140M Motor Protectors

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Miniature Circuit Breakers

IEC Contactors. IEC Contactors. YS Series. YS Series Contactors YS1N- F11 ****

1489-M Circuit Breakers

Manual Motor Starters. Meta-MEC

Bulletin 193-T1 Bimetallic Overload Relays

Selection Guide Motor Control Device Solutions

KT4 Manual Motor Starter

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Ideal for use as a manual starter

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Technical Information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

FMotor Circuit Controllers

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

ACS motor protection circuit breakers KT 7 Introduction

Product Specification Sheet #3LD2.1

MS General Information Extended Product Type: MS

Bulletin 190E/191E Direct On-Line Eco Starters

Motor Circuit Breakers C4

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Bulletin 190S/191S Direct On-Line Compact Combination Starters

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Switches Unlimited Phone: * Fax:

JOSLYN CLARK VACUUM CONTACTORS

UL/CSA Non-fused Disconnect Switches

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

January 2003 Types AE317, AM317, AE318, AE319, IEC Non-reversing Combination Starters Vol. 2, Ref. No. [0476] Application Description

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

System pro M compact Miniature Circuit Br eakers Description Features

Meta Solution. Contactors and Overload relays

CENTERLINE 2100 Motor Control Centers

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

Enclosures. See Section Typical Description

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Industrial contactors CTX-1

UL Enclosed Disconnect Switches (Fused and Non-Fused)

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Page 2-4 Page 2-8. Page Page 2-13

Series KTU7 UL489 Molded Case Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Series L9 UL-489 Miniature Circuit Breakers

A302DN.40/.63A Thermal Current Motor Starter

Tmax Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers

3. Coils shall be of molded construction

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

B Mini Contactor V Hz

Bulletin 1489 Circuit Breakers. Selection Guide

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Manual Motor Starters

Product Selection 3-Pole Contactors

Technical Information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

File E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Tmax Molded Case Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

LOW VOLTAGE SWITCHGEAR

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Rotary Disconnect Switches, Bulletin 194R

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

4 - Miniature controls

Short-Circuit Current Ratings

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

MPCB. We touch your electricity everyday! State of the art Manufacturing Facilities. Haridwar, Noida Ph-I & Noida Ph-II Plant

Ktec Contactors and thermal overloads

Thermal-magnetic Miniature Circuit Breaker 4230-T...

C E R T I F I C A T E O F C O M P L I A N C E

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

For 200V 3 Phase Motors 185. For 240V 3 Phase Motors 187. For 480Y/277V 3 Phase Motors 189. For 600Y/347V 3 Phase Motors 191. UL Listed CSA Certified

MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Essential equipment for all your requirements

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Industrial Contactors CTX 3 3P 185A - 800A

Self-protected Combination Starters System PKZ 2-SP

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Section Contents. Disconnect Switches

Motor Protection Circuit Breaker, versatile efficient technologically advance compact design

KT4 Manual Motor Starters

Bulletin 825 SMM Smart Motor Manager

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Compact Circuit Protector (CCP) Application Note

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors Technical data

Transcription:

Bulletin 190-M Selection Guide

Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located on Load Side of Starter Load Side Coil Terminal Exposed for Ease of Wiring and Accessory Installation Provision for Bul. 100-C and 140 Accessories TABLE OF CONTENTS Description Page Description Page Product Selection..................................... 3 Dimensions..................................... 5 Description Bulletin 190-M are ideal for use in direct-on-line or group motor installations. These compact starters are prewired and assembled, 45mm wide, can be panel- or DIN Rail-mounted and will accept a wide range of MCS accessories. Conformity to Standards: IEC 947-4 Approvals: CE CSA 22.2 No. 14 CSA Certified (File: LR13908) Your order must include: UL 508 UL Listed (File: E 14841) Cat. No. of the compact starter and protector selected. with coil code auxiliary configuration If required, Cat. No. of any accessories. 2

Bulletin 190-M Product Selection Type 1 Protection Auxiliary contact connected to terminals on the bottom Utilizes accessories of Bulletin 140-M Manual Motor Starter/Protectors & 100-C Contactors Mounting Options: Screw fixing Fixing on one or two 35mm DIN Rails Fixing on one 75mm DIN Rail Type 1 short circuit coordination according to IEC 947-4-1➊ Conditional rated short-circuit current (I q ) = Ultimate short-circuit breaking capacity (I cu ) Voltages: please inquire about other voltages 3 (50Hz) [kw] Ratings AC-2, AC-3 3 (60Hz)➋ [HP] Thermal Release Magnetic Release I cu without Current Limiter I cu with Current Limiter Direct-on-line Starter 400V 230V 460V 575V [A] [A] [ka] [ka] Catalog No. ➌ - ➍ 0.02 0.10...0.16 1.8 100 190-M2-A16 10-A10 0.04 0.16...0.25 2.8 100 190-M2-A25 10-A10 0.06/0.09 0.25...0.40 4.4 100 190-M2-A40 10-A10 0.09/0.12 0.40...0.63 6.9 100 190-M2-A63 10-A10 0.18/0.37 1/2 1/2 0.63...1.00 11 100 190-M2-B10 10-A10 0.37/0.55 3/4 1 1.00...1.60 18 100 190-M2-B16 10-A10 0.55/0.75 1/2 1 1-1/2 1.60...2.50 28 100 190-M2-B25 10-A10 1.1/1.5 1 1 3 2.50...4.00 44 100 190-M1-B40 10-A10 2.2/2.5 1-1/2 3 5 4.00...6.30 69 100 190-M1-B63 10-A10 3.0/5.5 3 5 7-1/2 6.30...10.0 110 20 50 190-M1-C10 10-A10 5.5/7.5 5 10 10 10.0...16.0 176 10 50 190-M1-C16 10-A10 7.5/10 5 10 10 16.0...20.0 220 8 50 190-M1-C25 10-A10 11/12.5 7-1/2 15 15 20.0...25.0 275 8 50 190-M1-C25 10-A10 ➊The Bulletin 140 Manual motor Starter/Protector is a component of the 190-M Compact Starter and meets the circuit breaker requirements of IEC 947-2. This device, however, does not meet CSA and UL circuit breaker requirements. The Bulletin 140 is CSA Certified and UL Listed as a Manual Motor Controller and is rated for Group Motor Installations. ➋ For North American applications: HP ratings shown in the table are for reference. The final selection of the motor starter depends on the actual motor full load current and service factor as follows. For motor with service factor of 1.15, or greater: Use motor nameplate full load current and choose the motor starter with the appropriate current range. Example: Motor F.L.C. = 4.2A; S.F. = 1.15. Select Cat. No. 190-M1-B63 10-A10. For motor with service factor less than 1.15: Multiply motor nameplate full load current by 0.9 and use the resulting value to choose the motor starter with the appropriate current range. Example: motor F.L.C. = 4.2A; S.F. = 1.0; 4.2A x 0.9 = 3.78A. Select Cat. No. 190-M1-B40 10A10. ➌ Auxiliary contacts for contactor Standard Voltage Codes for AC Control Option Contact Configuration 24V 110V 120V 01 50Hz D 60Hz J D ➍Trip and/or auxiliary contact for manual motor starter/protector 50/60 Hz Option Number of N.O./N.C. For other control voltage codes, contact your A-B sales office. T01 T10 1 N.O. A01 For other auxiliary contacts and accessories, see Pub. No. 0100C-1.0.1 3 Prices Consult Sales Office or price list

Type 2 Protection Bulletin 190-M Product Selection, Continued Type 2 short circuit coordination according to IEC 947-4-1 ➊ Conditional rated short-circuit current (I q ) = 50kA I cu = Ultimate short-circuit breaking capacity Voltages: please inquire about other voltages Ratings AC-2, AC-3 3 [kw] (50Hz) 3 [HP] (60Hz)➋ Thermal Release Magnetic Release I cu Direct-on-line Starter 400V 230V 460V 575V [A] [A] [ka] Catalog No. ➌ - ➍ 0.02 0.10...0.16 1.8 100 190-M2-A16 10-A10 0.04 0.16...0.25 2.8 100 190-M2-A25 10-A10 0.06/0.09 0.25...0.40 4.4 100 190-M2-A40 10-A10 0.09/0.12 0.40...0.63 6.9 100 190-M2-A63 10-A10 0.18/0.37 1/2 1/2 0.63...1.00 11 100 190-M2-B10 10-A10 0.37/0.55 3/4 1 1.00...1.60 18 100 190-M2-B16 10-A10 0.55/0.75 1/2 1 1-1/2 1.60...2.50 28 100 190-M2-B25 10-A10 1.1/1.5 1 1 3 2.50...4.00 44 100 190-M2-B40 10-A10 ➊The Bulletin 140 Manual Motor Starter/Protector is a component of the 190-M Compact Starter and meets the circuit breaker requirements of IEC 947-2. This device, however, does not meet CSA and UL circuit breaker requirements. The Bulletin 140 is CSA Certified and UL Listed as a Manual Motor Controller and is rated for Group Motor Installations. ➋For North American applications: HP ratings shown in the table are for reference. The final selection of the motor starter depends on the actual motor full load current and service factor as follows. For motor with service factor of 1.15 or greater: Use motor nameplate full load current and choose the motor starter with the appropriate current range. Example: Motor F.L.C. = 4.2A; S.F. = 1.15. Select Cat. No. 190-M1-B63 10-A10. For motor with service factor less than 1.15: Multiply motor nameplate full load current by 0.9 and use the resulting value to choose the motor starter with the appropriate current range. Example: motor F.L.C. = 4.2A; S.F. = 1.0; 4.2A x 0.9 = 3.78A. Select Cat. No. 190-M1-B40 10A10. ➌ Auxiliary contacts for contactor Standard Voltage Codes for AC Control Option Contact Configuration 24V 110V 120V 01 50Hz D 60Hz J D ➍Trip and/or auxiliary contact for manual motor starter/protector 50/60 Hz Option Number of N.O./N.C. For other control voltage codes, contact your A-B sales office. T01 T10 1 N.O. A01 For other auxiliary contacts and accessories, see Pub. No. 0100C-1.0.1 Prices Consult Sales Office or price list 4

Bulletin 190-M Approximate Dimensions Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. (1) 75mm DIN Rail (1) 35x15mm DIN Rail (2) 35x7.5mm DIN Rail Mounting Position 5

Publication 0190M-2.0 - June 1998 1998 Rockwell International. All Rights Reserved. Printed in USA