Purpose. Background. Exclusions

Similar documents
Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

White River Electric Association, Inc. Net Metering Information & Service Requirements

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

Battery Interconnection Process

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

Battery Interconnection Process

TERMS AND CONDITIONS

WASHINGTON ELECTRIC COOPERATIVE, INC. NET METERING TARIFF POLICY BULLETIN NO. 38 NM

24. SOLAR INCENTIVE PROGRAM II

WASHINGTON ELECTRIC COOPERATIVE, INC. NET METERING TARIFF POLICY BULLETIN NO. 38 NM

JEA Distributed Generation Policy Effective April 1, 2018

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

Application for Operation of & Net Metering for Member-Owned Generation Name: Mailing Address: City: County: State: Zip Code: _

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Schedule No. NMR-405 NET METERING RIDER-405 APPLICABLE

CHOCTAWHATCHEE ELECTRIC COOPERATIVE, INC RESIDENTIAL SERVICE--NET METERING RIDER

Northeastern Rural Electric Membership Corporation Columbia City, Indiana

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

TERMS AND CONDITIONS XXV. NET METERING CUSTOMERS AND SMALL AGRICULTURAL GENERATORS

City of, Kansas Electric Department. Net Metering Policy & Procedures for Customer-Owned Renewable Energy Resources

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT

M.P.S.C. No. 2 Electric Third Revised Sheet No. 65 (Rate Case) Cancels Second Revised Sheet No. 65

Net Metering in Illinois. Eric P. Schlaf Senior Economic Analyst Illinois Commerce Commission January 31, 2014

Mixed Generation Interconnection, Metering & Settlement

City of Washington, Kansas Electric Department. Net Metering Policy & Procedure For Customer-Owned Renewable Energy Resources

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

Renewable Net Metering Program Appendix ESD APX 001 1

Policy Bulletin No. 25 Net Metering. Public Utility District No. 1 of Klickitat County 1313 South Columbus Goldendale, WA 98620

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

NET ENERGY METERING RIDER Rider NEM. Certain words, when used in this Rider NEM shall be understood to have the following meanings:

NSTAR ELECTRIC COMPANY M.D.P.U. No. 28 EASTERN MASSACHUSETTS CAMBRIDGE SERVICE AREA GENERAL SERVICE

Interconnection Process for Generation Systems

P.S.C.U. No. 50 Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 136 STATE OF UTAH

2lr1344 CF 2lr1396. Drafted by: Heide Typed by: Rita Stored 02/02/12 Proofread by Checked by By: Senator Pinsky A BILL ENTITLED

DISTRIBUTED RESOURCE GENERATION Feed-In-Tariff Single Phase

Panola-Harrison Electric Cooperative, Inc. Louisiana Tariff Effective: March 3, 2004

Net Metering Program

REQUIREMENTS FOR PARALLEL OPERATION FOR CUSTOMERS WITH GENERATION NOT EXCEEDING 50 kw

Energy Storage System Application Guidelines

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board

S T A F F R E P O R T

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

TILLAMOOK PEOPLE S UTILITY DISTRICT

Springfield Utility Board Net Metering Policy Adopted on February 13, 2008 (Resolution 08-1)

Distributed Generation Interconnection Policy

216B.164 COGENERATION AND SMALL POWER PRODUCTION.

Net Metering Rate Option for Self-Generators

ELECTRIC DIVISION CUSTOMER-OWNED RENEWABLE GENERATION INFORMATION PACKAGE

Noble County Rural Electric Membership Corporation

Guideline on Energy Storage

Schedule SP SOLAR PURCHASE (Experimental)

ENERGY STRATEGY FOR YUKON. Net Metering Policy DRAFT FOR CONSULTATION

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

RAPPAHANNOCK ELECTRIC COOPERATIVE SCHEDULE NEM-8 NET ENERGY METERING RIDER

Overview of Net Energy Metering (NEM) Successor Tariff (NEM 2.0)

Noble County Rural Electric Membership Corporation

Louisville Gas and Electric Company

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM

RULES FOR CUSTOMER INTERCONNECTION OF ELECTRIC GENERATING FACILITIES

Dominion Energy Instructional Guide for Completing Virginia Form NMIN

TECHNICAL BRIEF Americas

HydroGenerations PROGRAM HANDBOOK

Douglas Electric Cooperative Roseburg, Oregon

Schedule GS-2 INTERMEDIATE GENERAL SERVICE

Louisiana Net Metering Service. Customer Information Package

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

Rider 11 Partial Requirements Service (PRS)

RENEWABLE ENERGY PROGRAM Step 1, Section 1 ENROLLMENT FORM FOR LEASED RESIDENTIAL AND SMALL COMMERCIAL PHOTOVOLTAIC AND WIND TURBINE SYSTEMS

Solar*Rewards Community Engineering Frequently Asked Questions For Garden Operators Minnesota

Rate Schedules. Effective 1/1/2019

Portland General Electric Company Fourteenth Revision of Sheet No P.U.C. Oregon No. E-18 Canceling Thirteenth Revision of Sheet No.

December 13, This document was filed with the Board of Public Utilities on December 13, It is awaiting final approval by BPU staff.

National Grid. Narragansett Electric Company INVESTIGATION AS TO THE PROPRIETY OF COMPLIANCE TARIFF CHANGES. 2 nd Amended Compliance Filing

Senate Substitute for HOUSE BILL No. 2101

SMALL POWER PRODUCER RIDER (Net Energy Billing Rate)

MENARD ELECTRIC COOPERATIVE POLICY MANUAL. SECTION IV Operating Rules for Cooperative Members

FRENCH BROAD ELECTRIC MEMBERSHIP CORPORATION RATE SCHEDULES

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM

RIPUC No Cancelling RIPUC No Sheet 1 THE NARRAGANSETT ELECTRIC COMPANY NET METERING PROVISION

LIBERTY UTILITIES (CALPECO ELECTRIC) LLC SOUTH LAKE TAHOE, CALIFORNIA 3rd Revised CPUC Sheet No. 137 Canceling 2nd Revised CPUC Sheet No.

Connecting your business diesel generation

Thank you for your time and attention to this matter. Please feel free to contact me if you have any questions regarding the filing.

Definitions. Scope. Customer Generation Interconnection Requirements

Net Metering & Compensation Seminar

Guidelines for Inverter-Based Micro-Generating Facility (10 kw and Smaller)

is attached to and becomes a part of a agreement dated, 20

SERVICE CLASSIFICATION "CEF" COMMUNITY ENERGY FACILITY

Basic tariff guiding principles

is attached to and becomes a part of a agreement dated, 20,

Consumer Guidelines for Electric Power Generator Installation and Interconnection

06/05/2018. COMMUNITY SOLAR OVERVIEW For Generation Owners and Subscribers

REVISION NO.: 7 EFFECTIVE: 07/07/16

BC Hydro writes in compliance with Exhibit A-4 to provide its Final Submission in respect of the Application (Exhibit B-1).

Transcription:

Guidance No. 1 for the Interconnection of Electric Storage as Stand-Alone Sources, Parallel Operation for Customers without Generation, and in Parallel with Self-Generation 1 Purpose This document provides guidance for the interconnection of electric storage batteries as a standby source or for operating in parallel with the utility to provide the customer with desired services such as demand reduction. This document applies to non-renewable generation when existing self-generation is present. Renewable generation requirements are covered in the separate companion Guidance Documents Nos. 2 and 3. Background In Proceeding No. 15AL-0048, the Company agreed to terms guiding the installation of customer sited energy storage facilities. This guidance document addresses the term that states: Customers with stand-alone energy storage interconnection are not required to have an interconnection agreement with the Company if they are in compliance with NEC 702, obtain an appropriate safety inspection, and can provide verifiable proof that those systems are operated such that they do not serve their main electrical panel. Customers with stand-alone battery interconnections are required to have an interconnection agreement when their system is operated in parallel with the grid by serving their main electrical panel. 2 This guidance may be modified from time to time to be consistent with the Company s policies for interconnection and operation of customer-sited storage. Exclusions This guidance addresses configurations and requirements related to the term above. This guidance does not apply to any situations or configurations where energy storage is operated in parallel with qualifying renewable generation using any form of net metering; generation that is metered under a buy-sell metering arrangement; or situations where there is generated power subject to a Power Purchase Agreement. 1 Self-generation is a customer supplying part or their entire load from onsite generation with no intent of export or payment for export. 2 Attachment A, Decision No. C16-1075, Pages 20-21. Page 1 of 5

Interconnection Reviews All electrical sources, including storage, that operate in parallel with Xcel are required to have an interconnection review and an Interconnection Agreement to ensure safety, system reliability, and operational compatibility. For purposes of this guidance, a source is considered to be operating in parallel with the grid when it is connected to the distribution grid and can supply energy to the customer simultaneously with the Company supply of energy. Any source operating in parallel to the grid is required to have an Interconnection Agreement. When a storage system is installed in conjunction with a generation system, both may be reviewed at the same time and be included in one Interconnection Agreement 3. When a storage system is installed after the generation system, the review level will be based upon the combination of the onsite generation rated capacity and the storage nameplate capacity for the selected operating mode 4 of the storage system 5. The operating modes will be part of the Interconnection Agreement requirements and any change in operating modes may require another review of the facility and possibly mitigations. If a storage system is installed at the same time as a generation source, a combined review is to be encouraged as the total time and cost will be less than two separate reviews. Onsite Generation and Energy Storage Configurations Three onsite storage configurations are achievable under this guidance: Standby Energy Storage Interconnections without Generation under NEC 702 (Diagram No. 1a) Energy Storage Operation in Parallel without Generation (Diagram No. 1b) Energy Storage Operation in Parallel with Non Net Metered Self-Generation 6 (Diagram No. 1c) Each diagram provides the representative configuration in principle and may have other features not reflected in the diagram, but the operational principle shall be consistent with the 3 Interconnections are reviewed based on the combined nameplate ratings of the sources that can actually be simultaneously supplied to the grid, such as two inverters. The ongoing operation capacity portion of the review is based on the actual simultaneous performance AC ratings. If the contribution of the energy storage to the total contribution is limited by programing or by some other on-site limiting element, the reduced ongoing capacity will be used. 4 Operating Modes includes such requirements as charging the energy storage only from an on-site renewable energy source that is net-metered, non-export requirements, or stand-alone storage systems. 5 Interconnections are reviewed based on the combined nameplate ratings of the sources that can actually be simultaneously supplied to the grid, such as two inverters. The ongoing operation capacity portion of the review is based on the actual simultaneous performance ratings. If the contribution of the energy storage to the total contribution is limited by programing or by some other on-site limiting element, the reduced ongoing capacity will be used. 6 Self-generation is a customer supplying part or their entire load from onsite generation with no intent of export or payment for export. Page 2 of 5

operational principle demonstrated by the diagram. The desired functionality may be controlled by inverter or control system programing. The diagrams are attached at the end of the text and are considered a part of this guidance. Standby Energy Storage Interconnections under NEC 702 (Diagram No. 1a) NEC 702 provides for optional standby (i.e. backup) systems. Optional standby systems are intended to supply power to public or private facilities or property where life safety systems do not depend on the performance of the system. Optional standby systems are intended to supply on-site generated or stored power to selected loads either automatically or manually. The generators or batteries do not operate in parallel with the utility. The Batteries may be charged from the utility but may not supply power to the customer s load outside of standby operations. The design is in conformance with the National Electric Code (NEC) Article 702 Optional Standby Power. This configuration is commonly used in conjunction with a Protected Load Panel that is normally fed from the main panel and can be fed by the standby system when the utility is unavailable. If the above standby conditions are met, the applicable state or local safety inspection has been obtained, and verifiable proof that the system operates in compliance with NEC 702 has been provided to Xcel Energy 7, the installation may proceed to operate without further approval or inspection and will not need an Interconnection Agreement. Xcel Energy reserves the right to conduct an inspection to verify compliance at a later date if problems arise or other indications of possible non-compliance are present. Energy Storage Operation in Parallel without Generation (Diagram No. 1b) If the customer has an onsite energy storage operating in parallel with the utility, meter registration will occur for exported power 8. Subject to the Inadvertent Export provisions below, the customer must provide the control system settings to ensure the power source does not export to the system as a part of the interconnection review. Xcel Energy reserves the right to conduct an inspection to verify compliance at a later date if problems arise or indications of possible non-compliance are present. Metering for this operating mode will be the standard service meters for the residential and small commercial tariffs. Standard meters register exported power as additional load. 9 At 7 Attestation is required and should include sign-off by installer/developer and customer. Attestations should identify specific hardware and software associated with the installed systems and those settings used to comply with the specified configuration as well as the settings being inaccessible and/or password protection must be restricted to the installer/developer/manufacturer. 8 Exported power will be recorded as load. 9 De minimis inadvertent power may be exported but substantial export will adversely affect the customer s bill. Page 3 of 5

some future date, standard service meters may be upgraded to bi-directional meters. 10 Where bi-directional measurement of delivery point power is used, both in and out quantities will be read. Energy Storage Operation in Parallel with Non Net Metered Self-Generation (Diagram No. 1c) 11 If the customer has onsite self-generation, meter registration will occur for exported power regardless of the source providing the power 12. Subject to the Inadvertent Export provisions below, the customer must provide the control system settings to ensure the energy storage power source does not export to the system as a part of the interconnection review. Xcel Energy reserves the right to conduct an inspection to verify compliance at a later date if problems arise or other indications of possible non-compliance are present. Metering for this guidance will be the standard service meters for the residential and small commercial tariffs. Standard meters register exported power as additional load. At some future date, standard service meters may be upgraded to bi-directional meters. Where bidirectional measurement of delivery point power is used, both in and out quantities will be read. Inadvertent Export The customer remains responsible for inadvertent energy exports. The term no export allows occasional de minimis inadvertent export of power. This recognizes that any parallel operation of a source with the utility may encounter brief upsets due to feeder or customer disturbances, sudden load changes, etc. Inadvertent export is the unscheduled and uncompensated export of real power generated from a customer s parallel operation and delivered to the Company. The use of an internal transfer relay, energy management system, or other customer facility hardware or software system(s) intended to prevent the reverse power flow, or net export, from the customer s energy sources across the point of interconnection is required. The magnitude of export shall be less than the nameplate rating (kw-gross) 13 and the duration of export of power from the customer s shall be less than 30 seconds for any single event. 10 Meters may require upgrading due to changing metering standards, metering technology changes, or new system control installation. 11 The customer may elect to use standby rates to minimize the economic impact that may occur when their generation is not available. 12 Exported power will be recorded as load. 13 The magnitude of export is based on the combined nameplate ratings of the sources that can actually be simultaneously supplied to the grid, such as storage and self-generation. If the contribution of the energy storage to the total contribution is limited by programing or by some other on-site limiting element, the reduced ongoing capacity will be used. Page 4 of 5

The cumulative amount of energy from the customer and delivered to the Company in any billing month shall be less than the on-site combined nameplate real power source ratings (kw-gross) 14 multiplied by one (1) hour. Any amount of export of real power across the point of interconnection lasting longer than 30 seconds for any single event shall result in a cease-to-energize or halt of energy production of the customer s energy sources within two (2) seconds of exceeding the 30-second duration limit. Where applicable, any failure of the Customer s control system for thirty (30) seconds or more, which includes but is not limited to; the internal transfer relay, energy management system, or other customer facility hardware or software system(s) intended to prevent the reverse power flow, shall cause the customer s energy sources to enter a non-export operational mode where no energy will be Inadvertently Exported to the grid. General Information Various tariffs measure capacity (demand) and energy (kwh) separately in 15 minute intervals. Some tariffs apply time-of-use rates. Any meter upgrade that is required for directional measurement will employ the same methodology for export measurement as is required by the tariff for delivered power and will be read at the same intervals. Illustrative diagrams of approved configurations are attached. 14 The magnitude of export is based on the combined nameplate ratings of the sources that can actually be simultaneously supplied to the grid, such as storage and self-generation. If the contribution of the energy storage to the total contribution is limited by programing or by some other on-site limiting element, the reduced ongoing capacity will be used. Page 5 of 5