Solid State Relays, 3-phase

Similar documents
DIN EN UL 508 / CSA 3RF A A 0 2

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Technical specifications

AF40... AF96 3-pole contactors Technical data

SIRIUS 3RU2 Thermal Overload Relays

For Operation in the Control Cabinet

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Solid State Relays contactor with Integrated Fuse Type RGC1F

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

ASL09..S 3-pole Contactors - Spring Terminals

Thermal overload relay TF65 and TF96

Description. Positive safety relays

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

For Operation in the Control Cabinet

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Thermal overload relay TF140DU and TF140DU-V1000

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Mini contactors B6, BC6 with 3 pole

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

Surface mounting, flush mounting, and DIN track mounting

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

MINI MCR-SL-UI-UI(-SP)(-NC)

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

AE 9... AE 40 Contactors NE... Contactor Relays

Model Number Structure

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Low-Voltage Controls and Distribution

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

TAE pole Contactors

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Thermal Overload Relays - WEG RW Series, 2 Pole

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

INDUSTRIAL POWER SUPPLIES SFL-SERIES

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Protection Equipment

Synergy EN product information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

DC/DC converters - MINI-PS DC/ 5-15DC/

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

B Mini Contactor V Hz

3RT14 Contactors with 3 Main Contacts

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Safety technique. Emergency Stop Module BH 5928, BI 5928

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

Manual motor starter magnetic only MO325

MINI MCR-SL-UI-UI(-SP)

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

SENTRON Switching and Protection Devices Switch Disconnectors

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Application Mini Contactors for Motors and Resistive Loads

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

Scheda prodotto Relè Series B

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

FL series position switches

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44

Short form catalogue. Motor protection & control

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Power Electronics. Motor brake relay GA 9031 ministop

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Siemens AG 2007 July 2007 V 1 N s L w alog Ne Cat sirius Soft Starters 3RW40 for standard applications

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Switching Power Supply

Control Circuit Protection

General_technical_data Series

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Solid State Relays Datasheet WG 480 D...Z

Electronic timers CT-E range Selection and ordering details

Industrial Power Supplies

LK Position Switches TECHNICAL DATASHEET.

Transcription:

PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection technologies Plug-in control terminal Degree of protection IP 2 Insulated mounting foot Standards / Approvals: DIN EN 6947-4-3 UL 8 / CSA 1 CE C-Tick Ordering Key: 3RF24 1-1 A C 4 3-phase solid state contactor with heat sink Max. load current Connection technology Switching function Controlled phases C = three-phase Control voltage Operating voltage = 48-6 V 1 = 1, A 2 = 22 A 3 = 3 A 4 = 4 A = A Not all possible versions are available ex stock! Main Circuit: Values for 4 C ambient temperature! 1 = Screw connection 2 = Spring-loaded connection 3 = Ring cable connection M A = Zero-point switching 4 = 4-3 VDC = 19-23 VAC I AC-1 I e acc. to Ie [ C] Power loss Min. load IEC947-4-3 UL/CSA with I AC-1 current Type A A A W A ma 3RF241-. AC. 1, 7 7 31,1 1 3RF242-. AC. 22 66, 3RF243-. AC. 3 22 22 91 3RF244-. AC. 4 3 3 121 3RF24-. AC. 38 38 16 Type 3RF24..-. AC. Rated operating voltage U e V 48... 6 Voltage range V 4... 66 Rated frequency Hz /6 ± 1 % Rated insulation voltage U i V 6 Rated impulse withstand voltage U imp kv 6 Slew rate V/µs 1 Rated impulse withstand strength Itsm I 2 t value Blocking voltage Type A A 2 s V 3RF241-. AC. 3 4 12 3RF242-. AC. 6 18 12 3RF243-. AC. 12 72 12 3RF244-. AC. 1 66 16 3RF24-. AC. 1 66 16 1 Use overvoltage protection device; max cut-off-voltage 6. V; min energy handling capability 1 J Max. leakage current

Control Circuit A1-A2: Type 3RF24..-. AC. 3RF24..-. AC4. Control voltage U s V AC 19... 23 DC 4... 3 Max. control voltage U s V 3 3 Typical operating current ma 3 Response voltage V 18 4 Drop-out voltage V <4 <1 Rated frequency of the control supply voltage Hz /6 ± 1 % -- Switching times ON delay ms 4 + Max. one half-wave 1 + Max. one half-wave OFF delay ms 4 + Max. one add. half-wave 1 + Max. one add. half-wave General Data: Ambient temperature During operation C -... 6 During storage C -... 8 Mounting altitude m... 1; at > 1 m, please contact our Technical Assistance Impact resistance acc. to DIN IEC 68 g/ms /11 Vibration resistance g 2 Degree of protection IP2 Electromagnetic compatibility (EMC) Interference emission o Conducted interference voltage IEC 6 947-4-3 Class A for industrial applications 2 o Radiated, high-frequency interference voltage IEC 6 947-4- Class A for industrial applications 3 Interference resistance o Electrostatic discharge acc. to IEC 61-4-2 (corresponds kv Contact discharge 4; air discharge 8; performance criterion 2 to severity 3) o Induced HF fields acc. to IEC 61-4-6 MHz.... 8; 14 dbµv; performance criterion 1 o Burst acc. to IEC 61-4-4 kv 2/. khz; performance criterion 1 o Surge acc. to IEC 61-4- kv Phase-to-ground 2; phase-to-phase 1; performance criterion 2 Dielectric Strength /6 Hz (Input, Output / Base) V rms 4 2 Attention! This product was constructed as an EMC Class A device. The use of this product in residential applications could lead to radio interferences. In such an application, additional filtering may be required. Subject to changes 2/27 Page 2/8

Type 3RF24..-1. 3RF24..-2. 3RF24..-3. Connection, main contacts Screw connection Spring-loaded connection Ring cable connection Conductor cross-section 2 2 x (1.... 2.), o Solid mm 2 x (2.... 6) 2x (.... 2.) 2 2 x (1.... 2.), o Finely stranded with end sleeve mm 2 x (2.... 6), 1 x 1 2x (.... 1.) o Finely stranded w/o end sleeve mm 2 2x (.... 2.) o Solid or stranded AWG 2 x (14... 1) 2 x (18... 14) Stripping length mm 1 1 Terminal screw M 4 - M o Tightening torque Nm 2... 2. - 2... 2. D...6 mm / PZ 2 lb.in 18... 22-18... 22 Cable lug DIN - - DIN 46234-2.... - JIS - - JIS C 28 R 2-14- Connection, control contacts mm² 1 x (.... 2.).... 2. 1 x (.... 2.) Conductor cross-section with or mm² 2 x (.... 1.) 2 x (.... 1.) without end sleeve AWG 2... 12 2... 12 2... 12 Stripping length mm 7 1 7 Terminal screw M 3 - M 3 o Tightening torque Nm.....6 -.....6 D 3. / PZ 1 lb.in 4.....3-4.....3 Fused Design with Semiconductor Protection Type Full-range fuse LV HBC design gr/sitor Semiconductor protection fuse LV HBC design ar / 3NE8 Semiconductor protection fuse, cylindrical design 1 x 38 mm ar / SITOR 14 x 1 mm ar / SITOR 22 x 8 mm ar / SITOR 3RF241-. AC. 3NE1813-3NE8-1 3NC112 3NC14 3NC222 3RF242-. AC. 3NE1814-3NE8-1 3NC1 3NC14 3NC22 3RF243-. AC. 3NE183-3NE83-1 3NC132 3NC1432 3NC2232 3RF244-. AC. 3NE182-3NE817-1 - 3NC14 3NC2 3RF24-. AC. 3NE1817-3NE818-1 - 3NC14 3NC2263 Accessories Function module Order No. Applicable for Versions Converter 3RF29-EA18 3RF24..-. AC4. Us = DC 24 V Subject to changes 2/27 Page 3/8

Characteristic Curves 3RF241-. 12 1 8 6 4 2 1 2 3 4 6 38 36 34 32 3 28 26 24 22 2 18 16 14 12 1 8 6 4 2 2 4 6 8 1 12 Upper curves: I max thermal limit current Middle curves: Rated current I e acc. to UL Lower curves: Rated current Ie acc. to DIN EN 6947-4-3 Continuous lines: Stand-alone mounting Dashed lines: Side-by-side mounting 3RF242-. 2 1 1 2 3 4 6 7 7 6 6 4 4 3 3 2 1 4 8 12 16 2 24 3RF243-. 3 Subject to changes 2/27 Page 4/8

4 3 3 2 1 1 2 3 4 6 1 11 1 9 9 8 8 7 7 6 6 4 4 3 3 2 1 6 12 18 24 3 36 Upper curves: I max thermal limit current Middle curves: Rated current I e acc. to UL Lower curves: Rated current Ie acc. to DIN EN 6947-4-3 Stand-alone and side-byside mounting 3RF244-. 3 4 4 3 3 2 1 1 2 3 4 6 3RF24-. 3 6 4 3 2 1 16 14 13 12 11 1 9 8 7 6 4 3 2 1 2 18 16 14 12 1 8 6 4 2 8 16 24 32 4 48 1 2 3 4 6 Mounting Instructions 4 : 1 2 3 4 3 Identical current/temperature curves for Stand-alone and side by side mounting. Subject to changes 2/27 Page /8

Device / Example Circuit Diagram: 4 Dimensions in mm, (in); Stand alone mounting, Characteristic Curves shows derating for Side-by-side mounting Subject to changes 2/27 Page 6/8

Dimension Drawings : Dimensions in mm, (in) Subject to changes 2/27 Page 7/8

P MA PMA Prozeß- und M aschinen- Automation GmbH P.O. B ox 31 2 29 D-348 Kassel Tel.: +49-61- 137 Fax: +49-61- 171 E -mail: mailbox@pma-online.de Internet: http://www.pma-online.de Your local representative: Printed in Germany - Edition 2/27 - Subject to alteration without notice - 9498 737 3213