1068 Magnum - 3 Phase 208V Oscar Box 1068 Magnum 3 Phase Oscar Box Features: IEC309 power-inlet and power-outlet or camlok Receptacles protected by Ericson's FS Series flip seal covers Clear polycarbonate window allows visual identification of circuit breaker status Choice of main inlet types Wide choice of receptacles Powder coated to prevent corrosion All steel heavy duty construction Feed-thru main power Up to 100 Amp 3 phase 208Y 120V Spring loaded flip lid with internal seal EXCLUSIVE Input power diagnostic module (IPDM) (details below) 1068 shown Heavy duty steel leg skids GFCI circuit breakers available Camlok Input Available IPDM Input power diagnostic module (IPDM), adjacent to power inlet, provides visual indication of supply power status - easy to read chart for quick reference. Standard on all models and field replaceable. 3ØY 120/208 60 & 100 Amp Inlets 32 1-800-ERICSON (374-2766) www.ericson.com
1068 Magnum - 3 Phase 208V Oscar Box Selection Guide Catalog Number 1068 1068-A 1068-C 1068-1 1068-1A 1068-1C Electrical Rating 3 Ph 208Y/120 60A 3 Ph 208Y/120 60A 3 Ph 208Y/120 125A 3 Ph 208Y/120 100A 3 Ph 208Y/120 100A 3 Ph 208Y/120 125A Powder Enclosure Powder Powder Powder Powder Powder Environmental/NEMA Rating Indoor/Outdoor 3R Indoor/Outdoor 3R Indoor/Outdoor 3R Indoor/Outdoor 3R Indoor/Outdoor 3R Indoor/Outdoor 3R Special Electronics Features Installed IPDM (Input Power Diagnostic Module) 24/7 LED indication of correct MAIN POWER connection Receptacles A Type Yes - 1 per box - 5 LED (4 green and 1 Red) NEMA 5-20 T Slot Single Yes - 1 per box - 5 LED (4 green and 1 Red) Yes - 1 per box - 5 LED (4 green and 1 Red) Yes - 1 per box - 5 Yes - 1 per box - 5 LED (4 green and 1 LED (4 green and Red) 1 Red) NEMA 5-20 T Slot Single Yes - 1 per box - 5 LED (4 green and 1 Red) Qty. 6 6 6 4 4 6 GFCI Protection Yes Yes Yes Yes Yes Yes Overload Protection Flip Covers* Yes Yes Yes Yes Yes Yes B Type n/a n/a n/a NEMA L21-20R (208V 3PH 5W 20A) NEMA L21-20R (208V 3PH 5W 20A) n/a Qty. n/a n/a n/a 2 2 n/a GFCI Protection n/a n/a n/a No No n/a Yes - 3P C.B. Yes - 3P C.B. Overload Protection n/a n/a n/a per circuit per circuit n/a Flip Covers* n/a n/a n/a Yes Yes n/a Main Power Inlet 5W 208V 60A IEC 5 pin 560I9 5W 208V 60A IEC 5 pin 560I9 CAMLOKS (150 Amp size) 5 color Male L1,L2,L3,N,G 5 pin 5100I9 5 pin 5100I9 CAMLOKS, LARGE (400 Amp size) 5 color Male L1,L2,L3,N,G Inlet Flip Cover No No No No No No Main Power Outlet (Mains Feed Thru) 5W 208V 60A IEC 5 pin 560R9 5W 208V 60A IEC 5 pin 560R9 CAMLOKS (150 Amp size) 5 color Female L1,L2,L3,N,G 5 pin 5100R9 5 pin 5100R9 CAMLOKS, LARGE (400 Amp size) 5 color Female L1,L2,L3,N,G Mains Feed thru Flip Cover Yes Yes Yes - Individual flips per camlok Yes Yes Yes - Individual flips per camlok Weight (lbs.) 42 42 44 44 44 46 Dimensions 22.5"L x 16.25"W 22.5"L x 16.25"W 22.5"L x 16.25"W 22.5"L x 16.25"W 22.5"L x 16.25"W 22.5"L x 16.25"W x 16.25"H x 16.25"H x 16.25"H x 16.25"H x 16.25"H x 16.25"H 65DSO 65PGTL Cat. Number Rating Length IEC Style Cordsets (ft) 65BSO 50 65DSO 100 60 A 65PGTL-50 50 65PGTL-100 100 45BSO 50 45DSO 100 45PGTL-25 90 A 25 45PGTL-50 50 45PGTL-100 100 Note: #2/5 also available - call for details. Cord Size Cord Type #6/5 SO #4/5 G Plug 4P 5W 60 Amp IEC 560P9E or equiv Blunt - ROJ 8" 4P 5W 100 Amp IEC 5100P9E or equiv Blunt - ROJ 8" Connector 4P 5W 60 Amp IEC 560C9E or equiv 4P 5W 100 Amp IEC 5100C9E or equiv MANY ERICSON PRODUCTS ARE LISTED OR CERTIFIED. FOR THE LATEST FULL SEARCHABLE LISTING BY PART NUMBER, GO TO: WWW.ERICSON.COM/AGENCY Note: Products shown on this page may not be listed. 33
Oscar Deluxe Temporary Power Distribution Centers - 1067 Series The 1067 Oscar Box, Temporary Power Distribution Unit for your jobsite. Typical Applications Include: Industrial, commercial and residential construction projects General maintenance and repair work (MRO) in industrial facilities Temporary power distribution at carnivals, circuses, fairs & similar events Convention centers to distribute power for exhibitions & maintenance Photo studios to distribute power to flash & other photographic equipment Unit is field repairable by qualified personnel. Parts list and wiring diagram appear on underside of lid. Power inlet & outlet clearly marked on lid for quick identification. Heavy-duty safety, yellow powdercoated enclosure provides NEMA 3R weather resistance protection for circuitry. Each NEMA 5-20 outlet is individually GFCI protected. Yellow flip seal covers are labeled for quick identification of electrical ratings. CS6369 50A, 125/250V power outlet. FEATURE Input power diagnostic module (IPDM) (details below) FS series weatherresistant flip seal outlet covers protect each outlet. Use with Ericson s Perma-Tite plug to provide maximum weather resistance. CS6375 50Amp, 125/250V power inlet. Automatic power-up GFCIs are ready immediately. Only need to push reset after a trip. Heavy-duty powdercoated steel skids to insure rugged, dependable jobsite performance. Flip up door protects circuit breakers from damage & the weather. Threaded studs spot welded to inside of enclosure for mounting GFCIs minimizing screw-heads on outside which reduces number of areas to snag cords & clothing. FEATURE Exclusive voltage monitor modules (VMM) (details below) IPDM VMM Input power diagnostic module (IPDM), adjacent to power inlet, provides visual indication of supply power status - easy to read chart for quick reference. Standard on all models and field replaceable. Exclusive voltage monitor modules (VMM) continuously monitors voltage - if supply voltage falls outside of safe operating range VMM disconnects power to GFCIs/ outlets. 34 1-800-ERICSON (374-2766) www.ericson.com
Oscar Deluxe Temporary Power Distribution Centers - 1067 Series Selection Guide Catalog Number 1067 1067-A 1067-B 1067-C Electrical Rating 50A 125/250V 50A 125/250V 50A 125/250V 50A 125/250V 6250W/12500W 6250W/12500W 6250W/12500W 6250W/12500W Enclosure Powder Powder Powder Powder Environmental/NEMA Rating Indoor/Outdoor 3R Indoor/Outdoor 3R Indoor/Outdoor 3R Indoor/Outdoor 3R Special Electronics Features Installed IPDM (Input Power Diagnostic Module) 24/7 LED indication of correct MAIN POWER connection VMM (Voltage Monitor Module per phase) Causes GFCI circuits to open if voltage exceeds 150V or below 90V to protect equipment. Receptacles A Type (6 per box) NEMA 5-20 T Slot Single Locking Single NEMA 5-20 T Slot Single Qty. 6 6 6 6 GFCI Protection Yes Yes Yes Yes Overload Protection Locking Single Flip Covers No No Yes Yes B Type (1 Per Box) L6-30 (30A, 250V) L6-30 (30A, 250V) L6-30 (30A, 250V) L6-30 (30A, 250V) Qty. 1 1 1 1 240V GFCI Protection No No Yes Yes Overload Protection Yes - 2P NON-GFCI Yes - 2P NON-GFCI Yes - 2P GFCI Yes - 2P GFCI Flip Covers Yes Yes Yes Yes Power Inlet Inlet Flip Cover Yes Yes Yes Yes Power Outlet (Mains Feed Thru) Mains Feed thru Flip Cover Yes Yes Yes Yes Weight (lbs.) 35 35 37 37 Dimensions 22.5"L x 16.25"W 22.5"L x 16.25"W 22.5"L x 16.25"W 22.5"L x 16.25"W x 11.75"H x 11.75"H x 11.75"H x 11.75"H 63DSO 63YSTW Accessories Cat. Number 63DS0 (1) 63BS0 (1) 63YSTW Description Cord set, 100, #6/3-8/1 SO 50A 125V/250V Cord set, 50, #6/3-8/1 SO 50A 125V/250V Cord set, 3 ft. Y #6/3 & #8/1 (Gnd) 50A Power Outlet Receptacle in weatherproof box with lift cover and 24 leads 50A, 125V/250V (1) Also available as a secondary cable assembly - cord with connector only - to hard wire into your power source. See Our Complete Line of 50Amp Power Cords in the Power Cord Section MANY ERICSON PRODUCTS ARE LISTED OR CERTIFIED. FOR THE LATEST FULL SEARCHABLE LISTING BY PART NUMBER, GO TO: WWW.ERICSON.COM/AGENCY Note: Products shown on this page may not be listed. 35
Oscar Temporary Power Distribution Centers - 1067LC Series The 1067-LC Oscar Box, Temporary Power Distribution Unit for your jobsite. Typical Applications Include: Industrial, commercial and residential construction projects General maintenance and repair work (MRO) in industrial facilities Temporary power distribution at carnivals, circuses, fairs & similar events Convention centers to distribute power for exhibitions & maintenance Photo studios to distribute power to flash & other photographic equipment Meets OSHA & NEC Codes for jobsites and carnivals, fairs and outdoor events. Unit is field repairable by qualified personnel. Parts list and wiring diagram appear on underside of lid. Heavy-duty safety yellow powdercoated enclosure provides NEMA 3R weather resistance protection for circuitry. Power inlet & outlet clearly marked on lid for quick identification. Each NEMA 5-20 outlet is individually GFCI protected. Blue flip seal covers are labeled for quick identification of electrical ratings. CS6369 50A, 125/250V power outlet. CS6375 50Amp, 125/250V power inlet. FS series weatherresistant flip seal outlet covers protect each outlet. Use with Ericson s Perma-Tite plug to provide maximum weather resistance. Flip up door protects circuit breakers from damage & the weather. 1067LC Heavy-duty powder-coated steel skids to insure rugged, dependable jobsite performance. Automatic power-up GFCIs are ready immediately. Only need to push reset after a trip. Power Option: Can be daisy chained together! Product label with clear markings for easy identification of model number, serial number and specifications. CS6375 50Amp, 125/250V power inlet. 36 1-800-ERICSON (374-2766) www.ericson.com
Oscar Temporary Power Distribution Centers - 1067LC Series Selection Guide Catalog Number 1067-LC* 1067-ALC* 1067-BLC* 1067-CLC* Electrical Rating 50A 125/250V 50A 125/250V 50A 125/250V 50A 125/250V Enclosure 6250W/12500W 6250W/12500W 6250W/12500W 6250W/12500W Powder Powder Powder Powder Environmental/NEMA Rating Indoor/Outdoor 3R Indoor/Outdoor 3R Indoor/Outdoor 3R Indoor/Outdoor 3R Receptacles A Type (6 per box) NEMA 5-20 T Slot Single Locking Single NEMA 5-20 T Slot Single Locking Single Qty. 6 6 6 6 GFCI Protection Yes Yes Yes Yes Overload Protection Flip Covers Yes Yes Yes Yes B Type (1 Per Box) L6-30 (30A, 250V) L6-30 (30A, 250V) L6-30 (30A, 250V) L6-30 (30A, 250V) Qty. 1 1 1 1 240V GFCI Protection No No Yes Yes Overload Protection Yes - 2P NON-GFCI Yes - 2P NON-GFCI Yes - 2P GFCI Yes - 2P GFCI Flip Covers Yes Yes Yes Yes Main Power Inlet Inlet Flip Cover Yes Yes Yes Yes Main Power Outlet (Mains Feed Thru) Mains Feed thru Flip Cover Yes Yes Yes Yes Weight (lbs.) 35 35 37 37 Dimensions 22.5"L x 16.25"W 22.5"L x 16.25"W 22.5"L x 16.25"W 22.5"L x 16.25"W * NF models are rated for INDOOR ONLY and do not have flip covers installed. x 11.75"H x 11.75"H x 11.75"H x 11.75"H Accessories Cat. Number Description 63DS0 (1) Cord set, 100, #6/3-8/1 SO 50A 125V/250V 63BS0 (1) Cord set, 50, #6/3-8/1 SO 50A 125V/250V Power Outlet Receptacle in weatherproof box with lift cover and 24 leads 50A, 125V/250V (1) Also available as a secondary cable assembly - cord with connector only - to hard wire into your power source. 63DSO 63YSTW See Our Complete Line of 50Amp Power Cords in the Power Cord Section MANY ERICSON PRODUCTS ARE LISTED OR CERTIFIED. FOR THE LATEST FULL SEARCHABLE LISTING BY PART NUMBER, GO TO: WWW.ERICSON.COM/AGENCY Note: Products shown on this page may not be listed. 37