Safety technique. Emergency Stop Module BH 5928, BI 5928

Similar documents
Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Power Electronics. Motor brake relay GA 9031 ministop

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Industrial Power Supplies

Electronic Braking Systems

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Solid State Relays, 3-phase

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

Electronic timers CT-S range Function diagrams

Safety Sensor CSS 180 Product Information

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

MasterINTERFACE 39 Series - Relay interface modules

5 mm contact pin pitch PCB or 95 series sockets

Safety Control HR1S-AC. Safety Relay HR1S-AC

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

40 Series - Miniature PCB relays A. Features

DIN EN UL 508 / CSA 3RF A A 0 2

DEVICE STATE/BYPASSED FAILURE OVERLOAD

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Electronic timers CT-E range Selection and ordering details

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Components for EEx e Panels

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

LED Driver Compact fixed output

LED Driver Compact fixed output

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

MINI MCR-SL-UI-UI(-SP)

MINI MCR-SL-UI-UI(-SP)(-NC)

QUINT-PS/24DC/24DC/ 5/CO

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

3RT14 Contactors with 3 Main Contacts

QUINT-PS/24DC/48DC/ 5

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Electronic Circuit Breaker ESS20-0..

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

QUINT-PS/24DC/24DC/20

AF40... AF96 3-pole contactors Technical data

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

DC POWER SUPPLY SYSTEMS

QUINT-PS/24DC/24DC/10

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

44 SERIES. PCB/Plug-in relays from 6 to 10 A

DC/DC converters - MINI-PS DC/ 5-15DC/

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

H3DS-X - Solid State Two-Wire Timer

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Description. Positive safety relays

2 pole 10 A PCB mount A1 A

Electronic Circuit Breaker ESS20

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

KD LV Motor Protection Relay

AE 9... AE 40 Contactors NE... Contactor Relays

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Commissioning Instructions Inbetriebnahme Anleitung VB 230/ L (LP)

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

LED Driver Linear / area fixed output

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

QUINT-PS/24DC/24DC/10/CO

LED control gear Compact fixed output

In-Rail-Bus Bus system in DIN-rail

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Application Mini Contactors for Motors and Resistive Loads

Emergency lighting units EM powerled

Safety door-handle system STS

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20.

SIRIUS 3RU2 Thermal Overload Relays

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

BETA Switching Switches and Light Indicators

EM DC Multi-Function DC Energy Meter

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Miniature Industrial relay 8-16 A

General purpose relays 6-10 A

Technical data. Miniature Circuit Breakers. System pro M. System pro M

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

General purpose relays 7-10 A

60 Series - General purpose relays 6-10 A. Features SERIES

Open Frame Power Supplies

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Transcription:

Safety technique Emergency Stop Module BH 5928, BI 5928 with time delay safemaster 0226419 Function diagram According to EU directive for machines 98/37/EG According to IEC/E 60 204, E 954-1 Safety category 4 according to E 954-1 Output 3 O or 2 O, 1 C instantaneous contacts and 3 O release delayed contacts Single and 2-channel operation Line fault detection on -button, when -button is connected to - Manual restart with button on - or automatic restart with bridge between - With or without cross fault monitoring in the loop LED indication for supply, channel 1/2 and release delayed contacts Removable terminal strips Wire connection also 2 x 1,5 mm 2 stranded ferruled (isolated), DI 46 228-1/-2/-3/-4 or 2 x 2,5 mm 2 stranded ferruled DI 46 228-1/-2/-3 BI 5928.50 with 2 separate time adjustments for nominal voltage AC/DC 24 V Width BH 5928 45 mm BI 5928 67,5 mm Approvals and marking * ET Canada / USA * see variants Applications Protection of people and machines Emergency stop circuits on machines Monitoring of safety gates Stop category 1 can be realised Indication upper LED lower LEDs on, when supply connected on, when relay and resp. t and t energized otes To select automatic restart terminals - must be bridged, - must be opened. Open terminals - select manual restart, the button must then be connected to -. Line fault detection on -button The line fault detection is only active when the time delayed relais t and t have released and then (channel A) and (channel B) are switched simultaneously. If the -button is closed before,, is connected to voltage (also when line fault across -button), the output contacts will not close. The unit will not restart before the time delay is finished. A line fault across the -button which occurred after activation of the relay, will be detected with the next activation and the output contacts will not close. If a line fault occurs after the voltage has been connected to,,, the unit will be activated because this line fault is similar to the normal -function. The unit can be operated with single channel and 2-channel operation with cross fault monitoring. For connection please refer to application examples. All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 1 BH 5928, BI 5928 / 23.10.06 e

Block diagram 13 23 31 47 57 67 Overvoltage and short circuit prot. Monitoring logic Timer release delay t 24V t t etz t t t 24 32 48 58 68 M7072_c Circuit diagrams 13 23 33 41 57 13 23 37 47 t t 13 23 33 41 57 t t 13 23 37 47 24 38 48 24 34 42 58 M7277_b 24 38 48 M8076 24 34 42 58 BH 5928.47 BH 5928.91 13 23 31 47 57 67 t t 13 23 31 47 57 67 t t 24 32 48 58 68 24 34 48 58 68 M7278_c M7279_c 24 32 48 58 68 24 34 48 58 68 BH 5928.92 BH 5928.93 2 BH 5928, BI 5928 / 23.10.06 e

Circuit diagrams 13 23 33 41 57 13 23 33 41 57 67 t t 13 23 33 41 57 t 1 t 2 t 1 t 2 13 23 33 41 57 67 t1 t2 24 34 42 58 24 34 42 58 68 M8081_a M8509 24 34 42 58 24 34 42 58 68 BI 5928.47 BI 5928.50 13 23 31 47 57 67 t t 13 23 31 47 57 67 t t 24 32 48 58 68 24 34 48 58 68 M8080_a M8079_a 24 32 48 58 68 24 34 48 58 68 BI 5928.92 BI 5928.93 otes The gold plated contacts of the BH 5928 mean that this module is also suitable for switching small loads of 1 mva - 7 VA, 1 mw - 7 W in the range 0,1-60 V, 1-300 ma. The contacts also permit the maximum switching current. However since the gold plating will be burnt off at this current level, the device is no longer suitable for switching small loads after this. The terminal permits the operation of the device in IT-systems with insulation monitoring, serves as a reference point for testing the control voltage and is used to connect the loop when cross fault monitoring is selected. Connecting the terminal to the protective ground bridges the internal short-circuit protection of Line. The short-circuit protection of line remains active. ATTETIO - AUTOMATIC START! According to IEC/E 60 204-1 part 9.2.5.4.2 it is not allowed to restart automatically after emergency stop. Therefore the machine control has to disable the automatic start after emergency stop. - must be closed to have timed outputs. By opening the bridge between and the time delay can be interrupted immediately. Without bridge the contacts switch without delay. The time setting has to be sealed by the user after test. Technical data Input ominal voltage U BH 5928, BI 5928.50 DC 24 V, AC/DC 24 V BI 5928 AC 110 V, 230 V Voltage range AC 0,85... 1,1 U DC AC/DC at 10% residual ripple 0,9... 1,1 U 0,95... 1,1 U at 48% residual ripple 0,8... 1,1 U 0,8... 1,1 U ominal consumption AC approx. 6,0 VA DC approx. 3,5 W ominal frequency 50 / 60 Hz Min. Off-time 1 s Control voltage on DC 23 V at U Control current over, 40 ma at U each Min. voltage on, DC 21 V when relay activated Short-circuit protection Internal PTC Overvoltage protection Internal VDR Output Contacts BH 5928.47, BI 5928.47 BH 5928.91 BH 5928.92, BI 5928.92 BH 5928.93, BI 5928.93 3 O, 1 C contacts instantaneous and 1 O contact release delayed 2 O contacts instantaneous, and 2 O contacts release delayed 2 O, 1 C contacts instantaneous and 3 O contacts release delayed 3 O contacts instantaneous and 3 O contacts release delayed 3 BH 5928, BI 5928 / 23.10.06 e

Technical data BI 5928.50 Operate delay typ. at U Manual start 40 ms Automatic start 500 ms Release delay typ. at U Disconnecting the supply 40 ms Disconnecting,, and 15 ms Time delay tv (release delayed) Repeat accuracy Contact type ominal output voltage 3 O, 1 O contacts instantaneous and 2 O contacts release delayed with separate time adjustment The not delayed O contacts are safety contacts. ATTETIO! The C contacts 31-32 or 41-42 can only be used for monitoring. Auxilary supply must be connected for time delay Time ranges 0,1... 1 s 3,0... 30 s 0,3... 3 s 6,0... 60 s 0,5... 5 s 30... 300 s 1,0... 10 s Other ranges or values on request Fixed values 1 s, 3 s, 5 s, 10 s, 300 s ± 1 % of setting value positive guided AC 250 V DC see limit curve for arc-free operation DC see limit curve for arc-free operation 100 mv 1 ma Max switching current Switching of low loads (Contact 5 µ Au) Thermal current I th in 1 contact path max. 5 A Switching capacity to AC 15 O contact AC 3 A / 230V IEC/E 60 947-5-1 C contact AC 2 A / 230 V IEC/E 60 947-5-1 to DC 13 O contact AC 2 A IEC/E 60 947-5-1 C contact AC 2 A IEC/E 60 947-5-1 to DC 13 O contacts DC 8 A / 24 V O 0,4 s, OFF 9,6 s Electrical life to AC 15 at 2 A, AC 230 V 10 5 switching cycles IEC/E 60 947-5-1 Permissible operating frequency max. 1200 switching cycles / h with manual restart and short release delay time Short circuit strength max. fuse rating 6 A gl IEC/E 60 947-5-1 line circuit breaker C 8 A Mechanical life 10 x 10 6 switching cycles General data Operating mode Continuous operation Temperature range - 15... + 55 C Clearance and creepage distances overvoltage category / contamination level 4 kv / 2 IEC 60 664-1 EMC Electrostatic discharge 8 kv (air) IEC/E 61 000-4-2 HF irradiation 10 V / m IEC/E 61 000-4-3 Fast transients 2 kv IEC/E 61 000-4-4 Surge voltages between wires for power supply 1 kv IEC/E 61 000-4-5 between wire and ground 2 kv IEC/E 61 000-4-5 HF-line-conducted 10 V IEC/E 61 000-4-6 Interference suppression Limit value class B E 55 011 Degree of protection Housing IP 40 IEC/E 60 529 Terminals IP 20 IEC/E 60 529 Housing Thermoplastic with V0 behaviour according to UL subject 94 Vibration resistance Amplitude 0,35 mm IEC/E 60 068-2-6 frequency 10... 55 Hz Technical data Climate resistance 15 / 055 / 04 IEC/E 60 068-1 Terminal designation E 50 005 Wire connection 1 x 4 mm 2 solid or 1 x 2,5 mm 2 stranded ferruled (isolated) or 2 x 1,5 mm 2 stranded ferruled (isolated) DI 46 228-1/-2/-3/-4 or 2 x 2,5 mm 2 stranded ferruled DI 46 228-1/-2/-3 Wire fixing Box terminal with wire protection, removable terminal strips Mounting DI rail IEC/E 60 715 Weight 400 g Dimensions Width x height x depth BH 5928 BI 5928 Standard type 45 x 84 x 121 mm 67,5 x 84 x 121 mm BH 5928.93 DC 24 V 0,5... 5 s Article number 0050369 Output 3 O contacts instantaneous and 3 O contacts release delayed ominal voltage U DC 24 V Time delay tv 0,5... 5 s Width 45 mm Variants BH 5928.47/61 BH 5928.92/61 BH 5928.93/61 BH 5928. /001 BH 5928.91/002 Ordering example for variants with UL approval with UL approval with UL approval with fix time delay fixed times 1 s, 3 s, 5 s, 10 s, 300s other times on request with absolute time scale time ranges 0,3... 3 s, 3... 30 s contact fusing 6 A fast, 4 A slow for DC 24 V B_ 5928. / _ AC/DC 24 V 50/60 Hz 1... 10 s 0,1... 1 s 0,3... 3 s 0,5... 5 s 1... 10 s 30... 300 s for fixed time end of scale value, other ranges on request only for AC/DC at BH 5928 DC 24 V at BI 5928 AC 230 V /000 standard, not stated in type number (for settable time ranges) /001 fixed time.47 = 3 O contacts, 1 C contact instantaneous and 1 O contact release delayed.91 = 2 O contacts instantaneous and 2 O contacts release delayed (only at BH 5928).92 = 2 O contacts, 1 C contact instantaneous and 3 O contacts release delayed.93 = 3 O contacts instantaneous and 3 O contacts release delayed H width 45 mm I width 67,5 mm 4 BH 5928, BI 5928 / 23.10.06 e

Characteristics 250 M7073_a Switching voltage U [ V] 200 150 100 50 0 1 2 3 4 5 6 7 8 Switching current I[A] safe breaking, no continuous arcing under the curve, max. 1 switching cycle/s Arc limit curve for resistive load Quadratic total current limit curve Application examples Off 13 13 23.. 24.. M7074_a Single channel emergency stop circuit. This circuit does not have any redundancy in the emergency-stop control circuit M7077_a Contact reinforcement by external contactors, 2-channel controlled. The output contacts can be reinforced by external contactors with positive guided contacts for switching currents > 5 A. Functioning of the external contactors is monitored by looping the C contacts into the closing circuit (terminals - or -) E- stop S1 13 13 M7075_a 2-channel emergency stop circuit without cross fault monitoring autostart and interruption of time by S1 M7078_a 2-channel emergency stop circuit with cross fault detection 5 BH 5928, BI 5928 / 23.10.06 e

Application examples 13 Sliding guard closed S1 S2 13 M7076_c auto start activated o contact (contact position closed) M7079_a Contact reinforcement by external contactors controlled by one contact path. - must be opened. 2-channel safety gate monitoring E. DOLD & SÖHE KG D-781 Furtwangen PO Box 1251 Telephone (+49) 77 23 / 654-0 Telefax (+49) 77 23 / 654-356 e-mail dold-relays@dold.com internet http//www.dold.com 6 BH 5928, BI 5928 / 23.10.06 e