Horizontal Circuit Switchers

Similar documents
Horizontal Circuit Switchers

Publication No.: PSG

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Transmission Switching

S&C Series 2000 Circuit-Switchers Outdoor Transmission 69 kv through 230 kv

Transmission Switching

Typical Specification

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Medium Voltage Metal-Enclosed Switches

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

C1000 Series Automatic Cap Bank

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

Medium Voltage Metal-Enclosed Switches

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

SECTION MOTOR CONTROL

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Three-Phase Pole Mounted Recloser

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Replacement Parts Bulletin For Line Backer TM Circuit Switchers

Solid Dielectric, Single Phase Recloser

Product Specifications for Aluminum Vertical Break Switches

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

TYPE V CENTER BREAK SWITCH

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Bolted contact switches. Pringle switches

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

SPECIFICATION BULLETIN

Type SDV7 distribution circuit breaker family

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Aluminum Vertical Break Switch kv A.

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Type SDV7 distribution circuit breaker family Answers for energy.

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

SWITCHGEAR DIVISION PRODUCT PROFILES

EMPAC Metal enclosed capacitor bank for wind applications

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

SECTION PANELBOARDS

Copper Vertical Break Switch kv A.

Copper Double Break Switch

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Switchgear Skid, C1192

SECTION MOTOR CONTROLLERS

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

SECTION MOTOR CONTROLLERS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Cobra-S. Catalog Cobra-S

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

Electric Motor Controls BOMA Pre-Quiz

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Underground Distribution Switchgear

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Underground Distribution Switchgear

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

S&C Switch Operators Types AS-1A and AS-10

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

Solid Dielectric, Single Phase Reclosers

Air-insulated switchgear UniGear type ZS1

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

SECTION MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

Product Specifications for Phase Over Phase GOABS(r)

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

INSTRUCTIONS. 1 Schematic. I Device ' I. S8C Switch Operators - Type CS-24. For Operation

OTEC Transfer switch open transition

Motor-drive mechanism, type BUL. Technical guide

MaxPak Plus Analog DC V S Drive

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Pretest Module 29 High Voltage Unit 1

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Instruction manual. Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module.

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Transcription:

> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving solution for transformer switching and protection. The Southern States circuit switcher design combines SF6 puffer interruption and optional air break isolation functions into a single compact unit for application on systems with fault currents to 40 ka rms. The three phase, group operated, interrupting device is typically mounted on a galvanized steel structure provided by Southern States or by others. Pole simultaneity is achieved through the use of shunt trips on opening and through mechanical interphase linkages on closing. A motor mechanism supplies the power to rotate the insulators and to reset both the tripping and the closing springs. Two versions of the Southern States horizontal circuit switcher are available: The Type CSH non-blade model is an end rotating insulator circuit switcher that mounts independent of an air disconnect switch. The Type CSH-B blade model is a center rotating insulator circuit switcher that mounts in series with an integral vertical break air disconnect switch. Both models are offered at voltage ratings of 38 kv through 170 kv and continuous current ratings of 1200, 1600, and 2000 amperes. Horizontal Circuit Switchers Types CSH & CSH-B 38 kv 170 kv 1200, 1600, 2000 Amperes

Types CSH and CSH-B Horizontal Circuit Switchers Key Features Interrupter design combines the use of SF6 gas and the most advanced puffer technology. Full strength interrupter insulation: Maintains full BIL insulation across the open interrupter. Permits use of the CSH non-blade model. Increases system reliability. Single gap interruption occurs without the use of voltage grading resistors or capacitors. Fast interrupting speeds significantly reduce system disturbance, minimizing damage to key system components: 5 cycles at 170 kv and below Fault closing and circuit making are fully contained within the interrupter unit: Provides superior equipment protection. Minimizes system disturbances.

Ratings Maximum Voltages 38,.3, 72.5, 123, 145, and 170 kv. SF6 Interrupter - BIL 550, and 750 kv CSH-B Disconnect Blade - BIL 200, 250, 350, 550, 650, and 750 kv Continuous Current - Amperes 1200, 1600, and 2000 Primary Bus Fault Interrupting Rating 20 ka rms Maximum Transformer Limited Fault 4 ka rms Interrupting Times (60 Hz) 5 cycles Close and Latch (fault closing, multiple duty) 108 ka peak 3-Second Short Time Current 40 ka rms Typical Assembly and Testing Each three-phase circuit switcher is factory pre-assembled, adjusted, tested, and timed with its own motor operator. After testing, the unit is matchmarked and disassembled in preparation for shipment or is shipped assembled on its common subframe. Individual phases are shipped assembled on insulators at all kv ratings. Warranty The CSH and CSH-B circuit switchers are covered by Southern States standard five year warranty. Typical Southern States CSH-B Circuit Switcher Side View

Interrupter Design Features System Fault Current Rated for systems up to 40 ka. Switching of magnetizing current occurs without restrikes. SF6 Interrupting Medium Units are typically shipped with 5-10 PSIG and are topped off to their rated pressure in the field. It is possible to ship fully pressurized when using composite interrupters. Operating Temperature Range -40º C to +40º C for 38 kv through 170 kv. (For applications at colder or warmer temperatures contact Southern States.) Interrupter Position Indicator The position of the interrupter is displayed in the driver window. A colored indicator, directly connected to the moving contact, visually indicates the interrupter s true position. Pressure Gauge Each phase is equipped with a fill valve, pressure gauge, and overpressure relief device. The pressure gauge is color-coded and visible from the ground. Full kv BIL Full BIL across the interrupter permits the switch blade to remain in the closed position indefinitely. The single gap design requires no dividing resistors. Contained Closing Closing takes place within the interrupter, not on the blade. Erosion of the switch blade contacts and jaw contacts is eliminated, minimizing the need for maintenance. There is no prestrike arcing on the switch jaws to cause system disturbance. No arc products are released into the atmosphere. The low noise level permits installations in residential areas.

Sequence of Operation Opening Sequence Steps 1 through 4 provide a brief illustration of the opening sequence, starting from the fully closed position. Rotation of the center insulator 12 degrees (by a shunt trip, motor operator, or manual crank) releases the opening springs in the driver mechanism, resulting in high speed opening of the interrupter contacts. An additional 114 degrees of rotation fully opens the switch blades as shown in Step 4. 1. Interrupter trips with contacts A and B in the closed position. A and B remain in contact as B travels over A and compresses the gas. Gas is ready to flow when the contacts part. Upon reaching the full open blade position, the driver mechanism is reset for a closing sequence. 2. Contacts part arcing begins gas flows to extinguish the arc. Charging of the shunt trip equipped units occurs during the last 12 degrees of opening rotation. Closing Sequence Rotation of the center insulator to close results in blade travel and charging of the interrupter closing springs in the driver mechanism. 3. Gas divides the arc interruption complete. Full BIL established. Blade signaled to open. The closing springs are released with the last few degrees of insulator rotation, closing the interrupter and charging the opening springs. With the CSH-B blade model, the switch blade is closed first, followed by closing of the interrupter, making the circuit in SF6 gas. 4. Switch blade now in full open position.

* Contact Southern States for detail. NOTE: All information contained herein is general in nature and is not intended for specific construction, installation, or application purposes. Other structure heights, phase spacings, column spacings, mounting positions, and anchor bolt spacings are available to meet specific installation requirements. Contact Southern States for details. Typical Anchor Bolt Detail Dimensions Typical Anchor Bolt Setting Plan 2 anchor bolt setting positions for 72.5 kv, 123 kv, 145 kv & 170 kv (72.5 kv and below ratings can also be furnished on single column structures.) Type CSH Table 1 Dimensions and Ratings Maximum kv Rating 72.5 123 145 170 Interrupter BIL (kv) 550 550 750 750 Standard Insulator TR No. 276 286 288 291 Standard Phase Spacings (Inches) Operator & Shunt Trip Voltage (VDC) Standard Structure Heights 60 84 -- 84 96 102 84 96 102 102 120 -- Dimension A (Inches) 76.0 76.0 90.3 90.3 Dimension B (Inches) 68.9 83.9 92.9 100.9 Table 2 Net Weight (Pounds) Maximum kv Rating 72.5 123 145 170 Structure Height 5612 6174 6624 6976 Structure Height 5751 6313 6787 7115 Structure Height 5887 6449 6899 7251 For dimensions, ratings, and weights of 38 kv and.3 kv units contact Southern States.

3 Column Structure * Contact Southern States for detail. NOTE: All information contained herein is general in nature and is not intended for specific construction, installation, or application Typical Anchor Bolt purposes. Other structure Detail Dimensions heights, phase spacings, column spacings, mounting positions, and anchor bolt spacings are available to meet specific installation requirements. Contact Southern States for details. Type CSH-B Table 1 Dimensions and Ratings Maximum kv Rating 72.5 123 145 170 Interrupter/Blade BIL (kv) 550/350 550/550 750/650 750/750 Standard Insulator TR No. 276 286 288 291 Standard Phase Spacings (Inches) Operator & Shunt Trip Voltage (VDC) Standard Structure Heights Typical Anchor Bolt Setting Plan 60 84 -- 84 96 102 84 96 102 102 120 -- Dimension A (Inches) 112.0 127.0 154.5 166.5 Dimension B (Inches) 57.4 57.4 72.5 72.5 Dimension C (Inches) 45.0 60.0 72.0 84.0 Dimension D (Inches) 68.9 83.9 92.9 100.9 Dimension E (Inches) 126.5 156.5 177.5 196.5 Table 2 Net Weight (Pounds) 3 Anchor Bolt Setting Positions for 170 kv. 2 Anchor Bolt Setting Positions for 72.5 kv, 123 kv,145 KV & 170 kv (72.5 kv and below ratings can also be furnished on single column structures.) Maximum kv Rating 72.5 123 145 170 Structure Height 6839 7821 8391 9994 Structure Height 6978 7960 8530 10234 Structure Height 7114 8096 8666 10474 For dimensions, ratings, and weights of 38 kv and.3 kv units contact Southern States.

Circuit Switcher Application Guide Types CSH and CSH-B Ratings Application Duty Maximum Amperes Transformer Switching and Protection Line or Cable Switching Load Breaking Parallel Switching Primary Bus Fault Interrupting Rating Max Transformer Limited Fault Loop Splitting Load Breaking Line, Cable Dropping 1200, 1600, 2000 1200, 1600, 2000 25,000 4,000 Southern States LLS Recommended Capacitor Switching Shunt Capacitor Bank Switching and Protection Southern States CapSwitcher Recommended Series Reactor Bypass 1200, 1600, 2000 Reactor Switching Shunt Reactor Switching Southern States RLSwitcher Recommended Southern States circuit switchers can close, carry, and interrupt the magnetizing current of the protected transformer. The rating shown is applicable for the following duty cycles: O or CO. Tripping of Southern States circuit switchers must be coordinated with source-side protective equipment for short-circuit currents in excess of this value. Rating is based on transient recovery voltage parameters defined in Table 2 of ANSI standard C37.06-2000 for Southern States circuit switchers rated 38 kv through 72.5 kv and Table 3 for 123 kv through 170 kv. Southern States circuit switchers are suitable for transformer primary applications where the inherent secondary fault current as reflected on the primary side of the transformer, assuming an infinite zero impedance source, does not exceed 4,000 amperes. The inherent secondary fault current may be calculated as follows: where KVA * 100 I = 3 * E * Z I = Inherent Secondary Fault Current KVA = Transformer Self-cooled 3-Phase Rating E = System Voltage (kv)z = Impedance Primary-to-Secondary in Percent (Inherent is defined as secondary-side fault current as reflected through the primary side of the transformer.) For applications where the inherent secondary fault current exceeds the above limits but where the maximum expected fault current, based on transformer impedance plus source impedance, is within these limits, contact Southern States. Southern States circuit switchers are suitable for use on systems with a maximum source fault of 40 ka.

Technical Data Operating Current Ratings Standard Accessories Optional Device Description Motor Inrush Current Motor Running Current Trip Coil Current Reversing Contactor Coil Anti-Pump Relay Coil Time Delay Relay Coil Motor Fuses Heater Fuses VDC (Amps) VDC (Amps) 75 33 15 7.5 25 25 1 0.5 0.2 0.1 0.2 0.1 30 30 Shunt Trip Unit Description VDC Trip Coil Resistance VDC Trip Coil Resistance 15 15 Ohms 15.5 5.7 Heater Resistance 500 Structures Southern States circuit switchers are designed for standard support structures provided by Southern States or others. For information on installation on existing support structures, information on other pre-designed structures, or for mobile applications contact Southern States. Motor Operator Southern States type CM-4AE motor operator is a torsional output, high torque unit capable of remote and supervisory control. Shunt Trip The shunt trip provides high speed tripping for fault protection of power transformers. Each phase has a shunt trip unit consisting of a spring, a latch, and a solenoid within a heated housing. When the system relay senses a fault the solenoid is energized and the spring is unlatched. This gives the insulator a high speed rotational kick, sufficient to break ¾ inch ice. The trip coil can be supplied at VDC or VDC, with either voltage coil drawing only 8.33 amperes. The three coils in parallel draw a total of 25 amperes from the time the solenoid is energized until the interrupter clears the fault, minimizing power requirements. Bypass Switch The bypass switch allows the interrupter (and integral disconnect switch blades on type CSH-B model) to be opened and closed for inspection and trip checking of the circuit switcher without opening the high voltage circuit. External Auxiliary Switch The external auxiliary switch, used in control circuits and interlocking schemes, is supplied in a separate weatherproof housing and is actuated by the vertical operating pipe. Ground Switch The ground switch is a three phase, group operated device furnished with the required momentary rating. Ground switches can be mounted in-line with the circuit switcher bases or perpendicular to the circuit switcher bases. Interlock Mechanical, electrical, and key interlocks are available if required for a specific application.

Type CM-AE Motor Operator General Application The CM-4AE is a precision built, torsional output, high torque motor operator for use with circuit switchers. It can also be used with disconnect switches and with load and line switchers such as the Southern States types LSH-B, LSH, LLS-II-2000, and LLS-II-3000. Motor A permanent magnet motor is available at VDC and VDC. All motors are NEMA rated and are supplied with permanently greased ball bearings. Overload protection is provided by standard dual element fuses which are easily removed. Brake Dynamic braking is standard for all CM-4AE motor operators. Cabinet The CM-4AE has an all-aluminum, maintenancefree, weatherproof cabinet. Two removable doors allow easy access to the controls, limit switches, motor, wiring, and other internal parts. To secure the motor operator from unauthorized entrance or operation the side door is latched internally and the front door has provisions for padlocking. Conduit Entrance The bottom of the cabinet is removable for field drilling to accommodate customer-furnished conduit. Reduction Gear The reduction gear is totally enclosed in a cast aluminum housing. It is a spur gear design with a worm gear shaft for manual hand crank operation. Gears and bearings are lifetime lubricated at the factory and require no maintenance. Manual Operation All type CM-4AE motor operators are designed to permit manual operation to facilitate installation, maintenance, and inspection. Operation of the circuit switcher manually is possible in the event of a source voltage failure to the motor circuit. Heater A 100-watt, thermostatically controlled heater is provided to prevent condensation inside the cabinet. Auxiliary Switch The auxiliary switch used in control circuits and interlocking schemes is installed within the motor operator housing. Contacts are field adjustable via an Allen wrench without disassembly of the auxiliary switch. Standard Features Position Indicating Lights Dead Front Panel Open-Close Pushbuttons Decoupler for Vertical Operating Pipe 12-Stage Auxiliary Switch (8 stages of which are for customer use) 120 VAC or 240 VAC, Thermostatically Controlled, 100-Watt Heater Operations Counter Fused Pullouts for Motor and Heater Circuits (provides visible open circuit) NEMA 56 Frame Size Motor ( VDC or VDC) 2 Hinged, Removable Doors Manual Crank Handle (insertion automatically disconnects motor circuit) Internal Cabinet Light with Toggle Switch Local-Remote Selector Switch Optional Features Extra Auxiliary Switch Stages (up to 4 additional, for a total of 16, 12 of which are for customer use) View Window in Front Cabinet Door Screened cabinet vents Fused Knife Switches (in lieu of fused pullouts) for Motor and Heater Circuits Molded Case Circuit Breakers (in lieu of fused pullouts) for Motor and Heater Circuits Terminal Lug for Cabinet Grounding Door Actuated Light Switch (in lieu of toggle switch) Trip Circuit Monitoring Relay Loss of Voltage Relays Duplex Receptacle with GFCI Bridge Rectifier (allows 120 VAC input to be converted into VDC for use in operating DC internal components of the motor operator) Contact Southern States for Availability of Optional Features Not Listed.

Feature Location A Manual Crank Handle B Decoupler (pistol grip type shown; pin type also available [and swing handle type is available for disconnect switch applications]) C Indicating Lights D Open & Close Pushbuttons E Operations Counter F Local-Remote Selector Switch G Hand Crank Interlock Switch H Motor, VDC or VDC I Auxiliary Switches J Anti-Pump Relay, Time Delay Relay, and Reversing Contactor K Hinged Removable Doors (2) L Terminal Blocks (4) M Fused Pullouts N Aluminum Cabinet

The Quality Name In High Voltage Switching 30 Georgia Avenue Hampton, Georgia 30228 Phone (770) 946-4562 Fax (770) 946-8106 e-mail: sales@southernstatesllc.com http://www.southernstatesllc.com 2017 Southern States, LLC PB 803-40 CSH CSH-B-R5 01062017 Printed in the U.S.A.