POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

Similar documents
1.Safe testing IMPORTANT:

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

DIGITAL RCD(ELCB) TESTER

KEWTECH. KT56 digital multi function tester. Instruction manual

OPERATING INSTRUCTION

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Distributor. Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA KEWTECH

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

Safety design conforming to the following provisions

OPERATING INSTRUCTION

KTD30 Digital Insulation and Continuity Tester

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

SafetyPAT Plus A B P/N:

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

KTD30 Digital Insulation and Continuity Tester. User Manual. kewtechcorp.com

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

Safety design conforming to the following provisions

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

OPERATING INSTRUCTION

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

362 Clamp Meter. Users Manual

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Autoranging Industrial Multimeter

Rental Industry Safety Tester Safe Check 5s

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

KMP Insulation-Continuity Tester. Users Manual

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

User Guide. Model Insulation Tester / Megohmmeter. Introduction

True RMS Autoranging Multimeter

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Digital/Analog Megohmmeter Model 1026

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

BATTERY OPERATED DIGITAL MILLI-OHMMETER

Autoranging Multimeter

User Guide. Model Insulation Tester / Megohmmeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Table of Contents Title Page No.

User Guide. Model Insulation Tester / Megohmmeter

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Declaration of Conformity

Date received into service; / /.

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Go to to register your product and find more information.

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Model Insulation Tester / Megohmmeter. User Manual

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

USER MANUAL. Insulation Tester + DMM. Model MG320

362 Clamp Meter. Users Manual

OPERATING INSTRUCTIONS

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Users Manual. Phase Rotation Indicator

SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0

Model UT601: OPERATING MANUAL

OPERATING INSTRUCTIONS

PAT120, PAT150 and PAT150R

User's Manual Digital High Voltage Insulation Tester Model

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

MIT300 Series Insulation and Continuity Testers

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

323/324/325 Clamp Meter

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

INSULATION RESISTANCE TESTER FOR PHOTOVOLTAIC SYSTEMS MSEI-200C INSTRUCTION MANUAL

Digital Multimeter User's Manual

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

BM kv Digital Insulation Tester USER MANUAL

Phase Sequence Tester

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Dawson DAN100. Analog Multimeter User s Manual

Attention ETCR8600 Leakage Protector Tester To read this user manual carefully. To comply with the operating cautions presented in this manual.

DLRO10HDX 10 Amp Digital Low Resistance

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

PY-11 Voltage & Continuity Tester

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

Dawson DDM190D. Digital Multimeter User s Manual

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

User's Manual. Earth Ground Resistance Tester. Model Introduction

LRCD200 Series Combined Loop and RCD Tester USER MANUAL

4-WIRE EARTH RESISTANCE TESTER C1 ES P1 S. Max. AC 200V MICROPROCESSOR CONTROLLED TEST. Switch ON, TEST, SCROLL RESULTS 20Ω 200Ω 2000Ω OFF

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

WENS30C Loop Calibrator

365 Detachable Jaw True-rms Clamp Meter

Instruction Manual. Model 310 Digital Milli-Ohm Meter

Transcription:

KT71 / Portable Appliance Tester POWERED BY Instruction Manual

CONTENTS 1. Safe testing 1 2. Procedure of removing cover.. 3 2.1 Method of removing the cover... 3 2.2 Method of storing the cover... 3 3. Product summary and explanation 4 3.1 Product summary... 4 3.2 Test function. 5 3.3 Features... 6 3.4 Instrument layout... 6 3.5 Explanation for indications... 9 3.6 Applicable standards.... 10 4. Specification. 11 4.1 General specification, measuring range and accuracy 11 4.2 Threshold and display.. 12 4.3 Reference test condition.. 12 5. Preparation before a measurement.. 13 5.1 Visual inspection 13 5.2 Connection to main power supply.. 13 5.2.1 Connection of mains cord. 13 5.2.2 Check the warning display of mains power voltage 14 5.2.3 Null setting (Protective conductor resistance function)... 14 5.2.4 Voltage setting for insulation resistance measurement... 16 6. Measuring method.. 17 6.1 Class I Test (Common function for both IT200mA and 20A).. 17 6.2 Class I Test (Select the leakage current test).. 19 6.3 Class Test..... 21 6.4 Class Test (Select the leakage current test)... 23 6.5 Extension Leads Test... 25 6.6 Leakage Current Test... 27 7. Fuse replacement 29 8. Case and strap assembly... 30 9. Maintenance..... 30

Electricity is dangerous and can cause injury and death. Always treat it with the greatest of respect and care. If you are not quite sure how to proceed, then stop, take advice from a qualified person. This instruction manual contains warning and safety rules which must be observed by the user to ensure safe operation of the instrument and retain it in safe condition. Therefore, read through these operating instructions before using the instrument. 1 Safe Testing IMPORTANT: This instrument must only be used by a competent and trained person and operated in strict accordance with these instructions. KEWTECH will not accept liability for any damage or injury caused by misuse or non-compliance with the instructions or with the safety procedures. It is essential to read and to understand the safety rules contained in these instructions and with the safety procedures. The symbol indicated on the instrument means that the user must refer to the related sections in the manual for safe operation of the instrument. Be sure to carefully read instructions following each symbol in this manual. DANGER is reserved for conditions and actions that are likely to cause serious or fatal injury. WARNING is reserved for conditions and actions that can cause serious or fatal injury. CAUTION is reserved for conditions and actions that can cause minor injury or instrument damage. DANGER This instrument can be connected only to the commercial power of 230V+10%-10%, 50Hz. For safety reasons, only use the Test Leads designed to be used with this instrument and recommended by KEWTECH. Use only grounded mains outlets to supply the instrument. Do not touch the device under test whilst testing is in progress. 1

Safe Testing DANGER Since a high voltage of 500V is being output continuously, when measuring insulation resistance, the user may get an electrical shock. Any capacitors in the appliance under test may become charged during testing and may contain hazardous voltages do not touch them. When testing, always be sure to keep your fingers behind the safety barriers on the test leads. Disconnect the instrument from the power supply when measurement is finished. Do not leave the instrument with connected to the power supply. WARNING Never open the instrument case because dangerous voltages are present. Only fully trained and competent electrical engineers should open the case. If abnormal conditions of any sort are noted (such as a faulty display, unexpected readings, broken case, cracked test leads, etc) do not use the instrument and return it to your distributor for inspection and repair. Never attempt to use the instrument if the instrument or your hands are wet. CAUTION When using Test Leads with the crocodile clip, be sure to check the crocodile clip is firmly connected to the metal part of the device under test. Otherwise, inaccurate measurements or arcing at the contacts may occur. The rated measuring voltage for the insulation test is 500V. DC. If this voltage seems too high for the appliance under test contact the appliance manufacturer for advice. The IEE Code of Practice allows for a touch current test where an insulation test cannot be carried out. When testing a faulty appliance, it may trip the circuit breaker of main power supply during test and may cause interruption of service. Be careful when the same main power supply is used for PCs. We are not liable for loss of data on PC during testing with this instrument. The appliance under test is powered on during most tests, but please turn it to the OFF position after testing. Use a very slightly damp cloth for cleaning the instrument. Do not use abrasives or solvents. 2

The KT71 has a dedicated cover to protect against an impact from the outside and to prevent the fascia, the LCD, and the connector socket from becoming dirty. The cover can be detached and put on the back side of the main body during measurement. 2 Procedure of removing cover 2.1 Method of removing the cover Fig.1 2.2 Method of storing the cover Fig.2 3

3 Product summary and explanation 3.1 Product summary The KT71 is a hand-held portable appliance tester, performing four functions to ensure the Safety of Class I and Class II appliances. Readings are displayed on a large liquid crystal display (LCD) below which are four bicolour LEDs, which unambiguously display a pass or fail indication for results dictated by the IEE Code of Practice. This instrument is suitable for performing tests as required by the following standard. The IEE Code of Practice for In-service Inspection and Testing of Electrical Equipment : 2003 This instrument is designed to check the electrical safety of appliances of Class I and Class II categories. As a guide the IEC standard define these two categories as follows: Class I : Appliances which have a functional insulation throughout and an earth connected case. These are often described as earthed appliances. Class II: Appliances which have both functional and additional insulation where any metal parts cannot become Live under fault conditions. 4

3.2 Test Function KT71 has the following features. Function Tests of contents Product summary and explanation Extension Lead Test Class I Test IT200mA Select Switch + Class I Test IT200mA Class I Test 20A Select Switch + Class I Test 20A Class ll Test Select Switch + Class II Test Leakage Current Test Protective conductor resistance (Test current 20A AC nominal) Insulation P/N-PE (Test voltage 250V DC or 500V DC) Polarity (Test current 200mA DC nominal) Protective conductor resistance (Test current 200mA DC nominal) Insulation (Test voltage 250V DC or 500V DC) Protective conductor resistance (Test current 200mA DC nominal) Load current and leakage current test Protective conductor resistance (Test current 20A AC nominal) Insulation (Test voltage 250V DC or 500V DC) Protective conductor resistance (Test current 20A AC nominal) Load current and leakage current test Insulation (Test voltage 250V DC or 500V DC) Load current and leakage current test Load current measurement (Maximum appliance current 13A) and leakage current test 5

Product summary and explanation 3.3 Features Check for whether the appliance is switched ON. Selection for 250V or 500V on the insulation resistance test. Null function for the earth bond test lead. Warning for the over range value by the LCD. Capable of judging pass/fail of tests by LEDs on the panel and by a buzzer. 3.4 Instrument layout Fig.3 Test socket Insert the mains plug of the appliance to be tested to this socket for the protective conductor resistance, insulation resistance, leakage current test and extension lead test. Terminal block Connect the supplied mains cord and Test Leads to this terminal block. Terminal for mains lead This terminal is connected to a mains supply via M-7209. 6

Terminal for Extension lead adaptor For use with the KAMP S (UK) extension lead adaptor. Product summary and explanation PE / Class II insulation probe Connect the Test Lead with crocodile clip (M-7208) (fig 5) to this terminal for the measurement of protective conductor resistance and Class II insulation, and clip the metal parts of the appliance under test with the crocodile clip. LCD Measured value is displayed LED for test result When the value of protective conductor resistance and insulation resistance exceeds the limit dictated by applicable standards, LED lights up in red. When it is within the limit, LED lights up in green. Start/Stop switch A measurement starts by pressing this switch. Pressing the Start/Stop switch again during a Leakage Current Test stops the measurements. NULL/250V-500V switch The rotary dial has to be set to a Class l test for this button to be used to zero out the test lead resistance. The rotary dial has to be set to Class ll for this button to be used to select either 250 V or 500V test voltage. Function switch Select a function with this switch. Select switch (Applicable for Class I and Class II function) When the function is set at the same time as the Select switch is being pressed, the leakage test will be conducted the insulation test. Fuse Protected by a 600V/10A ceramic fuse (F type 6.3x32mm). User can replace this fuse. 7

Product summary and explanation Mains cord (UK) M-7209 This mains cord can be connected to the mains supply so that the instrument can derive power from it. To measure contact current, the socket of the mains power supply has to have an earth terminal. Fig.4 Test Lead with safety crocodile clip(m-7208) and Probe with Blade type Prod(M-7163). The probe and crocodile clip are interchangeable. Please use it according to a measurement use. Probe with Blade Type Prod Crocodile Clip Fig.5 Extension leads adaptor KAMP S (UK) This is for connecting the instrument and an extension lead (cord reel). IEC Connector Fig.6 8

3.5 Explanation for indications LCD Display Product summary and explanation Insulation measurement voltage Power supply voltage (Live-Neutral) indication Leakage current indication Load current indication Null indication Unit indication Over range display: > is displayed on the LCD. Fig.7 9

Product summary and explanation List of display message => =>Value => =>Value => =>Value => =>Value => =>Value or Displayed when appliance under test is switched off. Displayed when the protective conductor resistance exceeds the threshold value. (*1) Displayed when the insulation resistance between LN-E is less than the threshold value. Displayed when the leakage current exceeds the threshold value. Displayed when the resistance between L-L exceeds 10 at extension lead test. Displayed when the resistance between N-N exceeds 10 at extension lead test. Displayed when the appliance under test is undergoing the leakage current test. Displayed when emergency stop is operated at leakage current test. Displayed when the mains voltage exceeds the range of specifications (207V to 260V). Testing will be diasabled. (*1) Please note that the IEE Code of Practice states that the maximum resistance should be no greater than 0.1 Ohms + the resistance of the mains cable 3.6 Applicable standards Instrument operation The IEE Code of Practice for In-service Inspection and Testing of Electrical Equipment : 2003 Safety IEC/EN61010-1 CAT.III 300V-instrument IEC/EN61010-031 CAT.III 300V(600V)-test lead EMC EN61326 (EN55022/EN61000-3,4) 10

4.1 General specification, measuring range and accuracy Measurement of protective conductor resistance - RPE 4. Specification Test function IT 200mA continuity 20A continuity test Measuring range Resolution Open-circuit voltage 0 ~ 15.00 10m 4 ~ 24V Measuring current 200mA DC (nominal) 20A AC (nominal) Accuracy ± (3%rdg+5dgt) Measurement of insulation resistance - RINS Output voltage 250V 500V Measuring range Resolution 0.1~19.99M 10k Open-circuit voltage 250V (+30%/-0%) 500V (+30%/-0%) Nominal current 1mA DC min. @250k 1mA DC min. @500k Short-circuit current Accuracy 2.5mA DC or less ± (2%rdg+3dgt) Measurement of leakage current test (With load current test) LEAK Test function Load current test Leakage current test Measuring range AC0.1~ 13.00Arms AC0.1~ 19.99mArms Resolution 10mA 10 A Accuracy ±(10%rdg ± 5dgt) ±(3%rdg ± 5dgt) Examination time Max 5 seconds Max 10 seconds Note: For MOV appliances use leakage current test. 11

Specification 4.2 Threshold and display Function Protective conductor resistance Insulation resistance Leakage current Polarity Extension Lead RPE 0.1 RINS 1M Cont 10 Class I IT200mA RPE 0.1 RINS 1M LEAK 3.5mA Class I 20A RPE 0.1 RINS 1M LEAK 3.5mA Class ll RINS 2M LEAK 0.25mA Leakage Current LEAK 0.75mA 4.3 Reference test condition Unless otherwise specified, this specification is dependent on the following conditions. (1) Ambient temperature: 23±5 C (2) Relative humidity: 45 ~ 75% (3) Attitude: Horizontal (4) AC power supply: 230V, 50Hz (5) Altitude up to 2000m, Indoor use Operating temperature and humidity range 0 ~ +40 Relative humidity: 85% or less (no condensation) Storage temperature and humidity range -20 ~ +60 Relative humidity: 85% or less (no condensation) Rate voltage and frequency Rated voltage: 230V ±10% Rated frequency: 50Hz ±1% Maximum rated power Load current at test socket: 3kVA(15sec.) Other test function: Approx.9VA Outer dimension and weight Outer dimension: 185(L) 167(W) 89(D)mm Weight: Approx. 1.3kg (Only the instrument body) 12

Symbols used on the instrument: Specification Eq uipment protected throughout by DOUBLE INSULATION or REINFORCED INSULATION Caution (Refer to the accompanying instruction manual) 5.1 Visual inspection Before starting a measurement, the user should undertake visual checks on the mains cord, case and that the correct type and rated fuse is fitted to the appliance under test. There should also be no evidence of damage of a nature that may impair the electrical safety of the appliance. 5. Preparation before a measurement 5.2 Connection to main power supply 5.2.1 Connection of mains cord Connect the mains supply and the instrument with M-7209 mains cord. M-7209 Fig.8 CAUTION Always be sure to check there are no abnormal conditions or damage to the instrument and leads. If any evidence of abnormality is found, measurement must be stopped immediately. The outlet of the mains power supply must have an earth terminal and be earthed. This instrument can be only connected to the commercial power of 230V+10%-10%, 50Hz. 13

Preparation before a measurement 5.2.2 Check the warning display of mains power voltage The warning device can work in any position of the function switch of the instrument. When Lo v or Hi v is displayed on the LCD at the time of the instrument connected with the mains power source, it means the measurement can not proceed because the mains voltage value of the instrument is out of the specific range. Do not connect the instrument with the mains power until the cause is identified. WARNING When the voltage of mains power supply is 260V or more, Hi v is displayed on the LCD. In that case, disconnect the mains cord of the instrument from main power supply. 5.2.3 Null setting The IEE Code of Practice pass level for protective conductor resistance is 0.1, which is a low value. So even the resistance of Test Leads will affect the measurement result. The KT71 can cancel the resistance of test lead by pressing NULL 250V/500V. The procedure of Null setting is shown below. The Null function is held in memory even when the instrument is turned off, so there s no need to Null the lead resistance every time. However, when replacing fuses or test leads, it is recommended to do a Null setting again. Procedure: (1) Set the function switch to Class I Test function. (Setting is possible at both IT200mA and 20A.) (2) Connect the mains supply and the instrument with the M-7209 mains cord. 14

Preparation before a measurement Fig.9 (3) Insert Test Lead with probe (M-7208) in to the E terminal of the instrument, and contact the tip of the Test Lead with the earth contacts of the socket on the instrument. Press the NULL 250V/500V switch whilst maintaining contact between the Test Lead and the earth contacts of the socket, the resistance of the Test Lead will be displayed on the LCD as shown in fig.10 for 2sec. Then, the instrument cancels the resistance value of Test Lead and adjusts the displayed value to 0.00 as shown in fig.10. The NULL icon is then displayed in the LCD. Null setting cannot be done when the resistance is 3 or more. A message no appears to indicate a resistance is exceeding the Null setting range. Display at Null setting Fig.10 15

Preparation before a measurement (4) Null setting can be released by pressing NULL 250V/500V switch for 2sec. The NULL icon on the LCD will disappear when Null setting is released. The Null setting and release can only be done in a Class I Test function. CAUTION Null setting can be set only with either Class I Test IT200mA or Class I Test 20A selected. It is possible that there is a different setting value between Class I Test IT200mA and Class I Test 20A. 5.2.4 Voltage setting for insulation resistance measurement (How to change between 250V and 500V) (1) Set the function switch to Class II Test function, and press the NULL 250V/500V switch. The LCD display will change to indicate the voltage selected. By pressing the NULL 250V/500V switch, 250V and 500V can be changed over. Fig.11 16

6.1 Class l Test (Common function for both IT200mA and 20A) The purpose of the test carried out for Class I appliances is to check the resistance of earth continuity from exposed metal parts and the plug is below a certain level and the insulation resistance between live and neutral connected together and earth is below 1MΩ. To conduct protective conductor resistance and insulation resistance tests on an appliance, connect the mains plug of the appliance to the test socket (1) described in clause 3.4 Instrument layout and the PE probe to terminal (5). Use the following setups, depending upon the type of appliance. 6. Measuring method Connect to exposed metal parts but not rotating parts or heating elements. Switch ON the power. Fig.12 17

Measuring method Class I Test Flowchart Start (1). Protective conductor resistance. Lights up in green RPE 0.1Ω? Yes (2).Appliance switch test Is the appliance switched on? Yes No No Lights up in red no Con value will be repeated on the LCD. (See note 1 below) Re-start Can proceed to the next step by pressing the Start switch again even if the result was a fail off? is displayed alternately on the LCD. Re-start (3). Insulation resistance between L/N and PE. LnE 1MΩ? Yes Lights up in green PASS No Lights up in red no LnE value will be repeated on the LCD. Value (1). and (3). will be alternately displayed on LCD Note 1: The IEE Code of Practice states that the maximum resistance should be no greater than 0.1 Ohms + the resistance of the mains cable. Therefore if the appliance has a long mains lead then the allowable resistance can be higher than the pre-programmed 0.1Ω. 18

CAUTION If the Appliance switch test fails, displayed by OFF and? appearing alternately on the LCD, and the appliance is actually switched on there may be a direct short between L and N. Suspend testing immediately. Follow the procedure described in 5.2.3 and undertake the Null setting before a measurement. The crocodile clip must make good contact with the enclosure of the appliance. When the terminal is open or the resistance value exceeds measuring range, > mark (over range display) appears on the LCD. Do not touch the appliance under test whilst testing is in progress. Since a high voltage of 500V will be present and the user may get an electrical shock. Measuring method 6.2 Class I Test (Select the leakage current test) common to both IT200mA and 20A function Turning the rotary dial to either Class I Test whilst the Select switch is being pressed down initiates a leakage current test instead of the Insulation resistance test. When selecting the leakage current test, exposed metal parts other than the heating or movable parts must be clipped with Test Lead M-7208 since the appliance will switch on and activate. Pressing the Start/Stop switch during the leakage current test stops the test immediately. To restart the test, press the Start/Stop switch again 2 sec after the test has been stopped. Then (1) Protective conductor resistance will be restarted. Fig 12 indicates how to connect the devices. Refer to item 6.6 on details of Leakage Current Test 19

Measuring method Class I Test (Select the Leakage Current Test) Flowchart Start (1). Protective conductor resistance. Lights up in green RPE 0.1Ω? Yes No Lights up in red no Con value will be repeated on the LCD. (See note 1 below) Re-start (2). Wait Standby until Start switch is pressed again whilst indicating on the LCD. (3). Appliance load current test. 5sec Measures load current of the instrument. (4). Power-on leakage current test. 10sec Measures leakage current of the appliance. LCD indicates during the measurement. LEA 3.5mA? No Lights up in red Lights up in green Yes Stop the test and no LEA value will be repeated on the LCD. PASS Value of (1),(3) and (4) will be alternately displayed on the LCD. Note 1: The IEE Code of Practice states that the maximum resistance should be no greater than 0.1 Ohms + the resistance of the mains cable. Therefore if the appliance has a long mains lead then the allowable resistance can be higher than the pre-programmed 0.1Ω. 20

CAUTION When the terminal is open or the resistance value, load current and leakage current exceeds the measuring range, > (over range display) appears on the LCD. If the test is stopped, a message StP appears on the LCD and values of leakage current are not displayed. Measuring method WARNING When c onducting a leakage t e s t t he a ppliance w ill automatically power on and will operate in its normal manner. It is imperative that the appliance is secured safely before the test is carried out. Extra care needs to taken with appliances which have heating elements and rotating parts. Firmly insert the plug of the appliance to the socket of the KT71. Plugs may get hot if leakage current test is performed with improper connection. Do not connect/remove the plugs during leakage current test. It may cause a reading error. Do not use the instrument on the device which has a power consumption of 3kVA or more. 6.3 Class ll Test The Class ll appliances have the indication of DOUBLE INSULATION or the symbol. The Class ll insulation test is to check the insulation resistance of the appliances is within the range defined in the standards. 21

Measuring method Switch ON the power. Connect to exposed metal parts but not rotating parts or heating elements. Fig.13 Class ll Test Flowchart Start (1). Appliance switch test Is the appliance switched on? Yes No When the resistance between L-N is about 100kΩ or more off? is displayed alternately on the LCD. Re-start (2). Insulation resistance between L/N and PE. Lights up in green LnE 2MΩ? Yes 22 No PASS Value of (2). will be displayed on the LCD. Lights up in red no LnE value will be repeated on the LCD.

CAUTION If the Appliance switch test fails, displayed by OFF and? appearing alternately on the LCD, and the appliance is actually switched on there may be a direct short between L and N. Suspend testing immediately. When the terminal is open or the resistance value exceeds the measuring range, > mark (over range display) appears on the LCD. Do not touch the appliance under test whilst testing is in progress. Since a high voltage of 500V will be present and the user may get an electrical shock. Measuring method 6.4 Class ll Test (Select the leakage current test) When turning the rotary dial to the Class II Test whilst pressing the Select switch, power-on leakage current test will be carried out instead of Insulation resistance test. When leakage current test is chosen, the appliance will switch on and operate in its normal manner. When connecting the test lead do not clip a metal a rotating part or heating element with the Test Lead M-7208. Refer to item 6.6 on details of Leakage Current Test 23

Measuring method Class II Test (Select the Leakage Current Test) Flowchart Start (1). Wait Standby until the Start switch is pressed again whilst the flashing icon is indicated. (2). Appliance load current test. 5sec Measures load current of the instrument. (3). Power-on leakage current test. 10sec Measures leakage current of the appliance. LCD indicates during the measurement. Lights up in green LEA 0.25mA? Yes No PASS Value of (2) and (3) will be displayed on the LCD. Lights up in red Stop the test and no LEA value will be repeated on the LCD. CAUTION When load current exceeds 15A or leakage current exceeds 20mA, > (over range display) appears on the LCD. If the test is stopped, a message StP appears on the LCD and values of leakage current are not displayed. WARNING When c onducting a leakage t e s t t he a ppliance will automatically power on and will operate in its normal manner. It is imperative that the appliance is secured safely before the test is carried out. Extra care needs to taken with appliances which have heating elements and rotating parts. Firmly insert the plug of the appliance to the socket of the KT71. Plugs may get hot if leakage current test is performed with improper connection. Do not connect/remove the plugs during leakage current test. It may cause a reading error. Do not use the instrument on the device which has a power consumption of 3kVA or more. 24

6.5 Extension Leads Test This test is for extension leads, and checks for; Protective conductor resistance between accessible conductive parts and connection of protective earth. Insulation resistance between L/N and PE. Polarity check of the Live and Neutral terminal of plug and socket. Measuring method Test procedure and the connection are as follows. Extension leads adapter KAMP S (UK) M-7209 Fig.14 25

Measuring method Extension Leads Test Flowchart Start (1). Protective conductor resistance test. Lights up in green RPE 0.1Ω? Yes No (2). Insulation resistance test between L/N and PE. Lights up in red no Con value will be repeated on the LCD. (See note 1 below) Re-start LnE 1MΩ? No Lights up in red Lights up in green Yes no LnE value will be repeated on the LCD. Re-start (3). Polarity test between L-L and N-N. L-L & N-N 10Ω? No Lights up in red no L-L value Yes or no n-n value will be repeated on the PASS LCD. Value of (1) and (2) will be alternately displayed on LCD. Note 1: The IEE Code of Practice states that the maximum resistance should be no greater than 0.1 Ohms + the resistance of the mains cable. Therefore if the appliance has a long mains lead then the allowable resistance can be higher than the pre-programmed 0.1Ω. 26

CAUTION Follow the procedure described in 5.2.3 and do Null setting before a measurement, but use the short KAMP S lead instead of the M-7208 test lead, by plugging the KAMP S. Into the Extension Lead Adaptor terminal and the UK socket on the front of the unit. When the terminal is open or the resistance value exceeds the measuring range, > (over range display) appears on the LCD. Do not touch the device under test whilst testing is in progress. Since a high voltage of 500V will be present, the user may get an electrical shock. Measuring method 6.6 Leakage Current Test This function is to conduct the leakage current test separately at mains voltage, the appliance will be automatically switched on and power up in its normal manner. The leakage current test, measures load current of the instrument for about 5 seconds, then measures leakage current for about 10 seconds and both measured results are displayed. The KT71 can measure up to 20mA although the threshold value is 0.75mA in this function. Set the function switch to Leakage Current Test position. Refer to the Fig12 or Fig13 for connection of an appliance. After set up is done, press the Start/Stop switch. (Indicated by the flashing icon on the LCD at standby mode.) Check the switch of the appliance is ON. Press Start/Stop switch again. The appliance will operate for 15 seconds and indicate the final values (value after 15 sec.) of load current and the maximum value of leakage current. 27

Measuring method Leakage Current Measurement Flowchart Start (1). Wait Standby until Start switch is pressed again whilst the flashing icon is indicated. (2). Appliance load current test. 5sec Measures load current of the instrument. (3). Power-on leakage current test. 10sec Measures leakage current of the appliance. LCD indicates during the measurement. LEA 0.75mA? Yes Lights up in green PASS No Lights up in red Stop the test and no LEA value will be repeated on the LCD. Value of (2) and (3) will be displayed on the LCD. - Remarks - Stopping the Test 1) Emergency stop and restart manually for power-on leakage current test: In order to stop testing the leakage current whilst measuring, press Start/Stop. To start a test again, press Start/Stop again after about 2 seconds or more from when the test has been stopped. The test will restart. 2) Auto stop of power-on leakage current test: The instrument stops measuring immediately when load current exceeds 15A or leakage current exceeds 20mA (but more than 3.5mA in Class I test function and more than 0.25mA in Class II test function). 28

WARNING When c onducting a leakage t e s t t he a ppliance w ill automatically power on and will operate in its normal manner. It is imperative that the appliance is secured safely before the test is carried out. Extra care needs to taken with appliances which have heating elements and rotating parts. Firmly insert the plug of the appliance to the socket of the KT71. Plugs may get hot if leakage current test is performed with improper connection. Do not connect/remove the plugs during leakage current test. It may cause a reading error. Do not use the instrument on the device which has a power consumption of 3kVA or more. Measuring method When the fuse blows during use, please replace with a new one according to below procedure. 7. Fuse replacement Fig.15 (1) Use a flat head screwdriver and turn about 45º to the left and remove the fuse cap and fuse. (2) Remove the fuse from the fuse cap and replace it with new one. (3) Refitting is the reverse procedure. 29

Fuse replacement WARNING Remove mains cord from the instrument before replacing the fuse. This is the only user replaceable fuse. Never attempt to perform any other repairs. CAUTION Please use the specified fuse (Fast acting type ceramic fuse: 600V/10A - 6.3x32mm). 8. Case and strap assembly The strap and test lead case can be attached to the instrument as below. Pass the strap belt down through the side panel of the main body from the top, and up through the slots of the test lead case from the bottom. (Fig. 16). Pass the strap through the buckle, adjust the strap for length and secure. Fig.16 9. Maintenance Use a very slightly damp cloth for cleaning the instrument. Do not use abrasives or solvents. 30

Kewtech Corporation Ltd. Midas House, Unit 2b Stones Courtyard High Street, Chesham Buckinghamshire HP5 IDE www.kewtechcorp.com 31

Tel:01494 792212 92-1890A 07-01

KT71 PAT Tester with Auto Test Sequence PRODUCT DATA SHEET KT71 PAT TESTER WITH AUTO TEST SEQUENCES Performs Earth bond at 200mA for IT appliances and high current 20A for all other appliances 250V / 500V insulation test voltages Run / leakage at 230V Single rotary dial position initiates test sequence Class I IT 200mA Earth Bond Class I 20A Earth Bond SPECIFICATIONS Class II MEASUREMENT OF PROTECTIVE CONDUCTOR RESISTANCE - RPE Memory for test lead resistance compensation Test Function Extension lead test including polarity IT 200mA continuity test 20A continuity test Measuring range LED indication of pass / fail as well as a result display Automatic check if appliance is switched on or not Test 110V appliances for earth bond and insulation (with appropriate test adaptor). Tests in accordance with the IEE Code of Practice 0 ~ 15.00 Ω Resolution 10mΩ Open-circuit voltage 4 ~ 24V Measuring current 200mA DC (nominal) Accuracy MEASUREMENT OF INSULATION RESISTANCE - RINS Rating 250V / 20M Ω and 500V / 20M Ω Measuring range 0.1~19.99M Ω Resolution 10kΩ Rated voltage ACCESSORIES 20A AC (nominal) ± (3%rdg+5dgt) 250V/500V DC(-0%/+30%) @250k Short-circuit current 2.5mA DC or less Accuracy ± (2%rdg+3dgt) Ω/500kΩ LEAKAGE CURRENT TEST (WITH LOAD TEST) - LEAK Mains Leads Test function Earth lead Measuring range Instruction Manual Resolution 0.01A Certificate of Conformity Accuracy ±(10%rdg ± 5dgt) Load current test AC0.1~13.00Arms Examination time Max 5 seconds Leakage current test AC0.1~ 19.99mArms 0.01mA ±(3%rdg ± 5dgt) Max 10 seconds THRESHOLD AND DISPLAY Function OPTIONAL Pass & Fail labels Insulation resistance Extension Lead RPE < 0.1 Ω RINS > 1M Ω Class I IT200mA RPE < 0.1 Ω RINS > 1M Ω Class I 20A RPE < 0.1 Ω Class II PATLOG1 PAT testing record log book Leakage Current Calibration Certificate Measurement Type t: 01494 792 212 Protective conductor resistance kewtechcorp.com Leakage current Polarity Cont < 10 Ω LEAK < 3.5mA RINS > 1M Ω LEAK < 3.5mA RINS > 2M Ω LEAK < 0.25mA LEAK < 0.75mA Averaging readings e: sales@kewtechcorp.com