PC T8 PRO, W T8 fluorescent lamps

Similar documents
FL ballasts Electronic fixed output PC T8 PRO, W PC PRO T8

FL ballasts Electronic fixed output. PC TCL PRO, W PC PRO compact

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

FL ballasts Electronic fixed output

FL ballasts Electronic fixed output

Electronic ballasts for fluorescent lamps Professional electronic ballast

FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

PC T8 TEC, W PC TEC

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

Emergency lighting units PC COMBO

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

Emergency lighting units PC COMBO

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

LED control gear Compact fixed output

LED Driver Linear / area fixed output

Emergency lighting units EM powerled

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

Emergency lighting units EM INVERTER

Emergency lighting units EM Inverter

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number

LED Driver Compact fixed output

LED Driver Compact fixed output

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM converterled

Emergency lighting units EM converterled

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

LE Fluorescent Ballast

Emergency lighting units EM converterled

Emergency lighting units EM converterled

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM series

Emergency lighting units EM series. EM BASIC, V BASIC version

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM INVERTER

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

LED Driver Linear / area dimming

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Emergency lighting units EM LED Light Engines

Emergency lighting units EM powerled

Table of contents. Electronic ballasts for fluorescent lamps Introduction 3

Emergency lighting units EM powerled

Emergency lighting units LED series

Emergency lighting units EM powerled

QTi 2X28/54/35/49 GII

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver

EM BASIC V 50/60 Hz

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting LED Driver

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting units LED

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE , CLE CLASSIC Modules CLE

LED light engine / OLED LED compact

Emergency lighting units EM powerled

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE CLASSIC / CLE CLASSIC Modules CLE

Tunable White LED linear / area

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

ETC310-FS LED

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Induction lamps and control gear

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

LED modules LED linear / area

QTi DALI 1X36/ DIM

LED light engine / OLED LED linear / area

Aura T5 Superlux US. A LED retrofit replacing T5 fluorescent

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

LED light engine / OLED LED linear / area. Module STARK LLE PREMIUM Modules LLE

LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

PHASED OUT. LED light engine / OLED LED compact. Module SLE G5 ART EXC Modules SLE EXCITE

LED light engines LED linear / area

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

QTP-M 2X Product datasheet. QUICKTRONIC-M ECG for circular FL 16 mm

LED light engine / OLED LED compact. Umodule SLE G4 FASHION EXC

Spiral T2 10,000 & 8,000 hours

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

QT 2X36/ DIM. Product datasheet. QUICKTRONIC INTELLIGENT DIM T8 ECG dimmable 1 10 V for FL 26 mm. Product benefits.

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC STARK LLE

PHASED OUT. LED light engine / OLED LED compact. Umodule STARK DLE GEN2 CLASSIC STARK DLE

Transcription:

T8 PC T8 PRO, 18 70 W T8 fluorescent lamps Product description Average life = 50,000 hours (at max ta. with a failure rate 0.2 % per 1,000 hours) Large temperature range (for values see table) Safety shutdown of defectvive lamps Automatic start after replacement of defective lamps For emergency lighting systems as per EN 50172 Constant luminous flux irrespective of fluctuations in mains voltage For luminaires of protection class 1 and protection class 2 For luminaires with F or M and MM as per EN 60598, VDE 0710 and VDE 0711 Insulation Displacement Connection (IDC) terminal for rapid automatic or manual wiring Temperature protection as per EN 61347-2-3 C5e Technical data AC voltage range DC voltage range Overvoltage protection Defined warm start Operating frequency Type of protection 198 264 V 176 280 V ( start 198 V DC) 320 V AC, 1 h 1.5 s 40 khz IP20 È Standards, page 3 Wiring diagrams and installation examples, page 5 Ordering data Type Article number For luminaires with 1 lamp PC 1/18 T8 PRO 22176093 PC 1/30 T8 PRO 22176077 PC 1/36 T8 PRO 22176217 PC 1/58 T8 PRO 22176094 PC 1/70 T8 PRO 22176171 For luminaires with 2 lamps PC 2/18 T8 PRO 22176107 PC 2/30 T8 PRO 22176078 PC 2/36 T8 PRO 22176218 PC 2/58 T8 PRO 22176215 PC 2/70 T8 PRO 22176232 For luminaires with 3 lamps PC 3/18 T8 PRO 22176187 PC 3/36 T8 PRO 22176231 For luminaires with 4 lamps PC 4/18 T8 PRO 22176163 Packaging 234 mm casing: 10 pieces/carton, 630 pieces/pallet Packaging 360 mm casing: 10 pieces/carton, 420 pieces/pallet Packaging PC 1/36 T8 PRO, PC 2/36 T8 PRO, PC 2/58 T8 PRO: 10 pieces/carton, 640 pieces/pallet www.tridonic.com 1

Specific technical data wattage type Type Length L Hole spacing D Weight wattage Circuit power EEI Current at 50 Hz λ at 50 Hz point Ambient temperature ta 220 V 240 V 220 V 240 V For luminaires with 1 lamp 1 x 18 W T8 PC 1/18 T8 PRO 234 mm 220 mm 0.28 kg 16 W 18.2 W A2 0.08 A 0.08 A 0.99 0.98 70 C -25... 60 C 1 x 30 W T8 PC 1/30 T8 PRO 234 mm 220 mm 0.28 kg 24 W 28.0 W A2 0.13 A 0.12 A 0.97 0.96 75 C -25... 60 C 1 x 36 W T8 PC 1/36 T8 PRO 234 mm 220 mm 0.28 kg 32 W 35.0 W A2 0.16 A 0.15 A 0.98 0.98 75 C -25... 60 C 1 x 58 W T8 PC 1/58 T8 PRO 234 mm 220 mm 0.28 kg 50 W 54.0 W A2 0.26 A 0.24 A 0.98 0.98 75 C -25... 50 C 1 x 70 W T8 PC 1/70 T8 PRO 234 mm 220 mm 0.20 kg 60 W 65.6 W A2 0.30 A 0.28 A 0.99 0.98 75 C -25... 55 C For luminaires with 2 lamps 2 x 18 W T8 PC 2/18 T8 PRO 234 mm 220 mm 0.28 kg 32 W 36.0 W A2 0.17 A 0.16 A 0.98 0.97 75 C -25... 60 C 2 x 30 W T8 PC 2/30 T8 PRO 234 mm 220 mm 0.28 kg 50 W 56.0 W A2 0.26 A 0.24 A 0.97 0.96 75 C -25... 60 C 2 x 36 W T8 PC 2/36 T8 PRO 234 mm 220 mm 0.28 kg 64 W 69.8 W A2 0.32 A 0.29 A 0.99 0.98 75 C -25... 55 C 2 x 58 W T8 PC 2/58 T8 PRO 234 mm 220 mm 0.28 kg 100 W 106.8 W A2 0.49 A 0.45 A 0.99 0.99 80 C -25... 50 C 2 x 70 W T8 PC 2/70 T8 PRO 360 mm 350 mm 0.32 kg 120 W 136.8 W A2 0.62 A 0.57 A 0.99 0.99 70 C -25... 50 C For luminaires with 3 lamps 3 x 18 W T8 PC 3/18 T8 PRO 234 mm 220 mm 0.28 kg 48 W 52.5 W A2 0.24 A 0.23 A 0.98 0.97 70 C -25... 60 C 3 x 36 W T8 PC 3/36 T8 PRO 360 mm 350 mm 0.31 kg 96 W 106.5 W A2 0.51 A 0.47 A 0.99 0.98 70 C -25... 50 C For luminaires with 4 lamps 4 x 18 W T8 PC 4/18 T8 PRO 234 mm 220 mm 0.28 kg 64 W 70.1 W A2 0.33 A 0.30 A 0.98 0.97 70 C -25... 55 C www.tridonic.com 2

Standards EN 55015 EN 61347-2-4 EN 61347-2-3 EN 60929 EN 61000-3-2 EN 61547 in accordance with EN 50172 IEC 68-2-64 Fh IEC 68-2-29 Eb IEC 68-2-30 starting characteristics Warm start Starting time 1.5 sec. with AC and DC operation Cathode heating will be reduced after preheat time AC operation Mains voltage: 220 240 V 50/60 Hz 198 264 V 50/60 Hz including safety tolerance (±10 %) 202 254 V 50/60 Hz including performance tolerance (+6 % / -8 %) DC operation 220 240 V 0 Hz 198 280 V 0 Hz certain lamp start 176 280 V 0 Hz operating range Light output level in DC operation: 100 % Emergency lighting Use in emergency lighting installations according to EN 50172 or for emergency luminaires according to EN 61347-2-3 appendix J. Instant start after mains interruption < 0.5 s Intelligent Voltage Guard Intelligent Voltage Guard is the name of the new electronic monitor from Tridonic. This inno vative feature of the PC PRO family of control gear from Tridonic immediately shows if the mains voltage rises above or falls below certain thresholds. Measures can then be taken quickly to prevent damage to the control gear. If the mains voltage rises above approx. 306 V (voltage depends on the ballast type), the lamp starts flashing on and off. This signal demands disconnection of the power supply to the lighting system. If the mains voltage falls below 150 V the control gear automatically disconnects the lamp circuit to protect the control gear from being irreparably damaged. Smart Heating Innovative heating circuit. Reduced filament heating after lamp has struck. Mains currents in DC operation Mains current at Un = 220 VDC Mains current at Un = 240 VDC PC 1/18 T8 PRO T8 1x18 W 0.08 A 0.07 A PC 2/18 T8 PRO T8 2x18 W 0.17 A 0.15 A PC 3/18 T8 PRO T8 3x18 W 0.24 A 0.22 A PC 4/18 T8 PRO T8 4x18 W 0.32 A 0.29 A PC 1/30 T8 PRO T8 1x30 W 0.16 A 0.15 A PC 2/30 T8 PRO T8 2x30 W 0.27 A 0.25 A PC 1/36 T8 PRO T8 1x36 W 0.16 A 0.14 A PC 2/36 T8 PRO T8 2x36 W 0.31 A 0.29 A PC 3/36 T8 PRO T8 3x36 W 0.51 A 0.46 A PC 1/58 T8 PRO T8 1x58 W 0.26 A 0.24 A PC 2/58 T8 PRO T8 1x58 W 0.50 A 0.46 A PC 1/70 T8 PRO T8 1x70 W 0.30 A 0.28 A PC 2/70 T8 PRO T8 2x70 W 0.61 A 0.57 A Harmonic distortion in the mains supply THD at 230 V / 50 Hz PC 1/18 T8 PRO T8 1x18 W < 12 % PC 2/18 T8 PRO T8 2x18 W < 10 % PC 3/18 T8 PRO T8 3x18 W < 10 % PC 4/18 T8 PRO T8 4x18 W < 10 % PC 1/30 T8 PRO T8 1x30 W < 10 % PC 2/30 T8 PRO T8 2x30 W < 10 % PC 1/36 T8 PRO T8 1x36 W < 10 % PC 2/36 T8 PRO T8 2x36 W < 10 % PC 3/36 T8 PRO T8 3x36 W < 10 % PC 1/58 T8 PRO T8 1x58 W < 10 % PC 2/58 T8 PRO T8 1x58 W < 10 % PC 1/70 T8 PRO T8 1x70 W < 10 % PC 2/70 T8 PRO T8 2x70 W < 10 % Working voltage Uout PC 1/18 T8 PRO T8 1x18 W 300 V PC 2/18 T8 PRO T8 2x18 W 300 V PC 3/18 T8 PRO T8 3x18 W 250 V PC 4/18 T8 PRO T8 4x18 W 300 V PC 1/30 T8 PRO T8 1x30 W 250 V PC 2/30 T8 PRO T8 2x30 W 250 V PC 1/36 T8 PRO T8 1x36 W 300 V PC 2/36 T8 PRO T8 2x36 W 300 V PC 3/36 T8 PRO T8 3x36 W 250 V PC 1/58 T8 PRO T8 1x58 W 300 V PC 2/58 T8 PRO T8 1x58 W 300 V PC 1/70 T8 PRO T8 1x70 W 250 V PC 2/70 T8 PRO T8 2x70 W 250 V Ballast lumen factor (EN 60929 8.1) AC/DC-BLF bei U = 198 254 V, 25 C PC 1/18 T8 PRO T8 1x18 W 1.00 PC 2/18 T8 PRO T8 2x18 W 1.00 PC 3/18 T8 PRO T8 3x18 W 1.00 PC 4/18 T8 PRO T8 4x18 W 1.00 PC 1/30 T8 PRO T8 1x30 W 1.00 PC 2/30 T8 PRO T8 2x30 W 1.00 PC 1/36 T8 PRO T8 1x36 W 1.00 PC 2/36 T8 PRO T8 2x36 W 1.00 PC 3/36 T8 PRO T8 3x36 W 1.05 PC 1/58 T8 PRO T8 1x58 W 1.00 PC 2/58 T8 PRO T8 1x58 W 1.00 PC 1/70 T8 PRO T8 1x70 W 1.00 PC 2/70 T8 PRO T8 2x70 W 1.00 www.tridonic.com 3

PC PRO with xitec processor Is the very latest in lighting management design technology. The lamp friendly warm start is delivering maximum T8 lamp life and enables high swihing frequency applications. Smallest power loss and new freedom in the lamp design thanks to convincing thermal management. Energy class CELMA EEI = A2 1) PC T8 PRO ignition technology (smart heating) optimises lamp start and ensures no energy is wasted. After the lamp has struck the filament heating is reduced automatically to a defined minimum value. This reduction in filament heating, saves energy, yet maintains the proper operating conditions for the lamp. The lamp is always operated within specification. 1) according to the EU directives on ecodesign requirements (EC) No. 245/2009 and (EC) No. 347/2010 PC 1/xx T8 PRO, PC 2/xx T8 PRO 15 mm 19 mm 143 mm 174 mm PC 3/36 T8 PRO, PC 2/70 T8 PRO 228 mm 260 mm Ambient Temperature -25 C to +50 C resp. 55 C resp. 60 C PC 3/18 T8 PRO, PC 4/18 T8 PRO 20 mm 15 mm 144 mm 175 mm PC 1/30 T8 PRO, PC 2/30 T8 PRO 140 mm 170 mm The nominal ta and point are related to the ballast life duration. The relation of to ta temperature depends also on the luminaire design. If the measured temperature is approx. 5 K below max., ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request. PC T8 PRO is designed for an average service life of 50,000 hours under reference conditions and with a failure probability of less than 10 %. This corresponds to an average failure rate of 0.2 % for every 1,000 hours of operation. Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: -40 C up to max. +80 C The devices have to be within the specified temperature range (ta) before they can be operated. Maximum loading of automatic circuit breakers Automatic circuit C10 C13 C16 C20 B10 B13 B16 B20 Installation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 PC 1/18 T8 PRO 44 62 74 104 22 31 37 52 PC 2/18 T8 PRO 36 50 60 72 18 25 30 36 PC 3/18 T8 PRO 40 60 80 92 20 30 40 46 PC 4/18 T8 PRO 30 40 52 64 15 20 26 32 PC 1/30 T8 PRO 40 52 60 72 19 26 30 36 PC 2/30 T8 PRO 22 30 38 42 11 15 19 21 PC 1/36 T8 PRO 38 52 60 72 19 26 30 36 PC 2/36 T8 PRO 24 32 38 44 12 16 19 22 PC 3/36 T8 PRO 18 24 32 40 9 12 16 20 PC 1/58 T8 PRO 36 50 60 70 18 25 30 35 PC 2/58 T8 PRO 16 22 26 30 8 11 13 15 PC 1/70 T8 PRO 20 26 34 42 10 13 17 21 PC 2/70 T8 PRO 10 14 18 20 5 7 9 10 Wiring advice The lead length is dependant on the capacitance of the cable. For safety reasons, the PC T8 PRO must only be earthed in the case of a safety class 1 luminaire. Earthing is not required for the device to operate. Connection to earth reduces radio interference. Ballast Terminal Maximum capacitance allowed Type Cold Hot Kalt Heiß PC 1xx T8 PRO 11, 12 9, 10 200 pf 100 pf PC 2xx T8 PRO 11, 12, 13, 14 9, 10 200 pf 100 pf PC 3xx T8 PRO 11, 12, 13, 14, 15, 16 9, 10 200 pf 100 pf PC 4xx T8 PRO 5, 6, 11, 12, 13, 14, 15, 16 9, 10 200 pf 100 pf With standard solid wire 0.5/0.75 mm 2 the capacitance of the lead is approx. 80 pf/m. This value is influenced by the way the wiring is made. In borderline cases the capacitance must be measured inside the luminaire. Keep lamp wires short. connection with twin ballast should be made with symmetrical wiring. Hot leads and cold leads should be separated as much as possible. To avoid the damage of the control gear, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, e.) www.tridonic.com 4

Installation instructions IDC interface solid wire with a cross section of 0.5 mm² according to the specification from WAGO Horizontal interface solid wire with a cross section of 0.5 1.5 mm² according to the specification from WAGO strip 7.5 8.5 mm of insulation from the cables to ensure perfect operation of the push terminals wire preparation: 0.5 1.5 mm² 7.5 8.5 mm Defective lamp If a lamp is defective, the ballast swihes off and goes into standby. There is an automatic restart once the lamp has been changed. Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. RFI Tridonic ballasts are RFI protected in accordance with EN 55015:2006 and A1:2007. To operate the luminaire correctly and and to minimise RFI we recommend the following instructions: Connection to the lamps of the hot leads must be kept as short as possible (marked with *) Mains leads should be kept apart from lamp leads (ideally 5 10 cm distance) Do not run mains leads adjacent to the electronic ballast Twist the lamp leads Keep the distance of lamp leads from the metal work as large as possible Connect functional earth, either over the terminal or over the mounting screw of the ballast Mains wiring to be twisted when through wiring Keep the mains leads inside the luminaire as short as possible Additional information Additional technical information at www.tridonic.com Technical Data Loosen wire T8 lamp information Guarantee conditions at www.tridonic.com Services No warranty if device was opened. wattage length 18 W 590 mm 30 W 900 mm 36 W 1200 mm 58 W 1500 mm 70 W 1800 mm 3 4 3 4 12 11 10 9 14 13 12 11 10 9 leads 11, 12 max. 2.0 m (< 200 pf) Protection class I - luminaires: earth of ballast housing required (according to IEC 598) PC 1x18 70 W T8 PRO leads 11, 12, 13, 14 max. 2.0 m (< 200 pf) Protection class I - luminaires: earth of ballast housing required (according to IEC 598) PC 2x18 70 W T8 PRO leads 11, 12, 13, 14, 15, 16 max. 2.0 m (< 200 pf) Protection class I - luminaires: earth via fixing of ballast housing (according to IEC 60598) leads 5, 6, 11, 12, 13, 14, 15, 16 max. 2.0 m (< 200 pf) Protection class I - luminaires: earth via fixing of ballast housing (according to IEC 60598) PC 3x18 36 W T8 PRO PC 4x18 W T8 PRO www.tridonic.com 5